{"id":29743,"date":"2024-10-17T03:20:50","date_gmt":"2024-10-17T03:20:50","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/asme-ptc-30-1-07\/"},"modified":"2024-10-24T14:14:21","modified_gmt":"2024-10-24T14:14:21","slug":"asme-ptc-30-1-07","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/asme\/asme-ptc-30-1-07\/","title":{"rendered":"ASME PTC 30.1 07"},"content":{"rendered":"
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
4<\/td>\n | CONTENTS FIGURES TABLES <\/td>\n<\/tr>\n | ||||||
6<\/td>\n | NOTICE <\/td>\n<\/tr>\n | ||||||
7<\/td>\n | FOREWORD <\/td>\n<\/tr>\n | ||||||
8<\/td>\n | COMMITTEE ROSTER <\/td>\n<\/tr>\n | ||||||
9<\/td>\n | CORRESPONDENCE WITH THE PTC 30.1 COMMITTEE <\/td>\n<\/tr>\n | ||||||
10<\/td>\n | Section 1 Object and Scope 1-1 OBJECT 1-2 SCOPE 1-3 UNCERTAINTY <\/td>\n<\/tr>\n | ||||||
12<\/td>\n | Section 2 Definitions and Descriptions of Terms 2-1 SYMBOLS 2-2 DEFINITIONS <\/td>\n<\/tr>\n | ||||||
13<\/td>\n | 2-1 Symbols <\/td>\n<\/tr>\n | ||||||
17<\/td>\n | Section 3 Guiding Principles 3-1 INTRODUCTION 3-2 AGREEMENT AMONG PARTIES TO THE TEST 3-2.1 Contractual Agreements <\/td>\n<\/tr>\n | ||||||
18<\/td>\n | 3-2.2 Pretest Agreements 3-3 UNCERTAINTY ANALYSIS 3-2.2 Noncondensible Gas Load Limits <\/td>\n<\/tr>\n | ||||||
19<\/td>\n | 3-3.1 Pretest Uncertainty Analysis 3-3.2 Post-Test Uncertainty Analysis 3-4 TEST PREPARATIONS 3-4.1 Equipment Inspection 3-4.2 Instrument Calibrations 3-5 ARRANGEMENT OF TEST APPARATUS 3-5.1 Required Measurements <\/td>\n<\/tr>\n | ||||||
20<\/td>\n | 3-5 Arrangement of Test Apparatus <\/td>\n<\/tr>\n | ||||||
21<\/td>\n | 3-6 TEST PERSONNEL 3-7 METHOD OF OPERATION DURING THE TEST 3-8 CONDUCT OF TEST 3-8.1 Test Modes 3-8.2 Starting and Stopping Tests and Test Runs 3-8.2.1 Starting Criteria. 3-8.2.2 Stopping Criteria. <\/td>\n<\/tr>\n | ||||||
22<\/td>\n | 3-8.3 Testing Conditions 3-8.3.1 Test Stabilization. 3-8.3.2 Operating Conditions. 3-8.3.3 ACC Operation. 3-8.4 Adjustments Prior to and During Tests 3-8.4.1 Permissible Adjustments During Stabilization Periods or Between Test Runs. 3-8.4.2 Permissible Adjustments During Test Runs. 3-8.4.3 Nonpermissible Adjustments. 3-8.5 Duration of Runs, Number of Test Runs, and Number of Readings 3-8.5.1 Duration of Test Runs. <\/td>\n<\/tr>\n | ||||||
23<\/td>\n | 3-8.5.2 Number of Test Runs. 3-8.5.3 Number of Readings. 3-8.5.4 Preliminary Test Runs. <\/td>\n<\/tr>\n | ||||||
24<\/td>\n | Section 4 Instruments and Methods of Measurement 4-1 INTRODUCTION 4-2 MEASUREMENT OF ENVIRONMENTAL EFFECTS 4-3 LOCATION OF TEST POINTS 4-3.1 General 4-3.2 Condenser Pressure 4-3.3 Steam Temperature 4-3.4 Steam Quality <\/td>\n<\/tr>\n | ||||||
25<\/td>\n | 4-3.5 Atmospheric Pressure 4-3.6 Inlet Air Temperature 4-3.7 Wind Velocity 4-3.8 Condensate Flow 4-3.9 Condensate and Makeup Temperatures 4-3.10 Fan Motor Input Power 4-3.11 Condensate Oxygen Concentration <\/td>\n<\/tr>\n | ||||||
26<\/td>\n | 4-4 INSTRUMENTATION AND METHODS OF MEASUREMENT 4-4.1 Condenser Pressure 4-4.2 Steam Temperature 4-4.3 Steam Quality 4-4.4 Atmospheric Pressure 4-4.5 Inlet Air Temperature 4-4.6 Wind 4-4.1-1 Basket Tip 4-4.1-2 Guide Plate <\/td>\n<\/tr>\n | ||||||
27<\/td>\n | 4-4.7 Condensate Mass Flow 4-4.8 Condensate and Makeup Temperatures 4-4.9 Fan Motor Input Power 4-4.10 Condensate Oxygen Concentration <\/td>\n<\/tr>\n | ||||||
28<\/td>\n | Section 5 Computation of Results 5-1 GENERAL 5-2 REVIEW OF TEST DATA AND TEST CONDITIONS 5-3 REDUCTION OF TEST DATA 5-3.1 Air-Side Conditions Data Reduction 5-3.2 Steam Side Data Reduction 5-4 ACC DESIGN DATA <\/td>\n<\/tr>\n | ||||||
29<\/td>\n | 5-5 PARTICULAR CALCULATIONS AT THE GUARANTEE POINT 5-5.1 Computation of LMTD at Guarantee Conditions 5-5.2 Computation of Number of Transfer Units NTU 5-5.3 Computation of Gamma Factor 5-6 ADJUSTMENT OF TEST DATA TO GUARANTEE CONDITIONS 5-6.1 General 5-6.2 ACC Performance Curves 5-6.3 Adjustment for Steam Quality 5-6.4 Adjustment of Atmospheric Pressure <\/td>\n<\/tr>\n | ||||||
30<\/td>\n | 5-6.5 Adjustment of Fan Power 5-6.6 Adjustment of ACC Pressure and Inlet Air Temperature 5-6.7 Computation of Capability 5-6.8 Interpretation of Capability in Terms of ACC Pressure 5-6.9 Condensate Temperature Corrections 5-7 CONDENSATE TEMPERATURE 5-8 OXYGEN CONTENT 5-9 TEST UNCERTAINTY <\/td>\n<\/tr>\n | ||||||
31<\/td>\n | 5-10 UNCERTAINTY ANALYSIS <\/td>\n<\/tr>\n | ||||||
33<\/td>\n | Section 6 Report of Results <\/td>\n<\/tr>\n | ||||||
34<\/td>\n | NONMANDATORY APPENDICES A SAMPLE CALCULATIONS OF PERFORMANCE A-1 DESIGN DATA A-2 TEST DATA A-2.1 Test Conditions A-2.2 Test Results A-3 CALCULATIONS A-3.1 Design Point Calculations A-3.2 ACC Performance Curves Para. 5-6.2 A-4 CORRECTIONS A-4.1 Correction for Steam Quality Para. 5-6.3 A-4.2 Correction for Atmospheric Pressure Para. 5\u00c36.4 <\/td>\n<\/tr>\n | ||||||
35<\/td>\n | A-4.3 Correction for Fan Power Para. 5-6.5 A-4.4 Correction for Condenser Pressure and Inlet Air Temperature Para. 5-6.6 A-4.5 Computation of ACC Capability in Terms of Steam Flow Para. 5-6.7 <\/td>\n<\/tr>\n | ||||||
41<\/td>\n | B DESCRIPTION OF PERFORMANCE CURVES B-1 INTRODUCTION B-1.1 Description of Curves B-1.2 Format B-1.2.1 Primary Format. B-1.2.2 Alternative Formats. B-1.2.3 Other Representations — Tabular Data. B-1.2.4 Other Representations — Equation Format. <\/td>\n<\/tr>\n | ||||||
47<\/td>\n | C UNCERTAINTY ANALYSIS EXAMPLE C-1 SENSITIVITY FACTORS <\/td>\n<\/tr>\n | ||||||
51<\/td>\n | D DERIVATION OF EXPONENTS mk AND n D-1 INTRODUCTION OF TERMINOLOGY AND DEFINITIONS D-2 CORRECTION FACTORS D-2.1 Exponent mk <\/td>\n<\/tr>\n | ||||||
52<\/td>\n | D-2.2 Exponent n D-2.3 Derivation of Correction Factor for Atmospheric Pressure, fp <\/td>\n<\/tr>\n | ||||||
53<\/td>\n | D-2.4 Correction for Fan Motor Power, ffp <\/td>\n<\/tr>\n | ||||||
54<\/td>\n | E CALCULATION OF THE STEAM QUALITY AT TEST CONDITIONS <\/td>\n<\/tr>\n | ||||||
56<\/td>\n | F TEST CALCULATIONS FOR DISSOLVED OXYGEN DETERMINATION F-1 INTRODUCTION F-2 SAMPLING FREQUENCY F-3 SAMPLE LOCATION F-4 SAMPLE METHODS <\/td>\n<\/tr>\n | ||||||
58<\/td>\n | G DATA SHEETS <\/td>\n<\/tr>\n | ||||||
63<\/td>\n | H REPORTING FORM OF RESULTS OF ACC PERFORMANCE TEST H-1 GENERAL INFORMATION NUMBER OF READINGS H-2 STEAM AND WATER CONDITIONS NUMBER OF READINGS H-3 POWER AND AIR NUMBER OF READINGS <\/td>\n<\/tr>\n | ||||||
64<\/td>\n | I PERFORMANCE MONITORING I-1 INTRODUCTION I-2 PERFORMANCE MONITORING TEST STRUCTURE I-3 PARAMETERS TO MONITOR I-4 MONITORING MEASUREMENTS <\/td>\n<\/tr>\n | ||||||
65<\/td>\n | I-5 CALCULATIONS <\/td>\n<\/tr>\n | ||||||
67<\/td>\n | J ROUTINE PERFORMANCE TEST J-1 OBJECTIVE J-2 GUIDING PRINCIPLES J-3 INSTRUMENTS AND METHODS J-3.1 Inlet Air Temperature J-3.2 ACC Pressure <\/td>\n<\/tr>\n | ||||||
68<\/td>\n | K ENVIRONMENTAL EFFECTS K-1 OBJECTIVES <\/td>\n<\/tr>\n | ||||||
69<\/td>\n | K-2 WIND EFFECTS <\/td>\n<\/tr>\n | ||||||
81<\/td>\n | L ELECTRIC POWER LINE LOSSES L-1 FAN MOTOR POWER L-2 LINE LOSS CORRECTION L-3 EXAMPLE CALCULATION TO DETERMINE LINE LOSS <\/td>\n<\/tr>\n | ||||||
85<\/td>\n | How can you reach us? It\u0152s easier than ever! <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" ASME PTC 30.1 Air-Cooled Steam Condensers <\/b><\/p>\n |