{"id":369500,"date":"2024-10-20T02:15:12","date_gmt":"2024-10-20T02:15:12","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/icc-significantchangestothempfc-2021\/"},"modified":"2024-10-26T03:51:32","modified_gmt":"2024-10-26T03:51:32","slug":"icc-significantchangestothempfc-2021","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/icc\/icc-significantchangestothempfc-2021\/","title":{"rendered":"ICC SignificantChangestotheMPFC 2021"},"content":{"rendered":"

Gain full access to the most critical updates to the International Plumbing Code\u00ae, International Mechanical Code\u00ae and International Fuel Gas Code\u00ae, the real world application of those changes, and why they originated\u2014all in a single easy-to-use resource. Significant Changes to the International Plumbing Code\u00ae, International Mechanical Code\u00ae, and International Fuel Gas Code\u00ae 2021 Edition provides a comprehensive analysis of the significant changes in the new editions of these codes, offering key insights into the implications of those changes. Each change analysis features the affected code sections and identifies the change as newly added text, a modification or clarification of the existing language or deleted text. Accompanying each change is a photograph, detailed illustration or comprehensive example to assist and enhance reader understanding. The book\u2019s attention to detail, its logical organization, and its thorough yet concise coverage all make it an ideal tool for transitioning from the 2018 to the 2021 editions of the International Plumbing Code\u00ae, International Mechanical Code\u00ae, and International Fuel Gas Code\u00ae.<\/p>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
1<\/td>\n2021 SIGNIFICANT CHANGES TO THE INTERNATIONAL PLUMBING CODE\u00ae, INTERNATIONAL MECHANICAL CODE\u00ae, INTERNATIONAL FUEL GAS CODE\u00ae <\/td>\n<\/tr>\n
2<\/td>\n2021 SIGNIFICANT CHANGES TO THE INTERNATIONAL PLUMBING CODE\u00ae, INTERNATIONAL MECHANICAL CODE\u00ae, INTERNATIONAL FUEL GAS CODE\u00ae TITLE PAGE <\/td>\n<\/tr>\n
3<\/td>\nCOPYRIGHT <\/td>\n<\/tr>\n
4<\/td>\nCONTENTS <\/td>\n<\/tr>\n
8<\/td>\nPREFACE <\/td>\n<\/tr>\n
12<\/td>\nSIGNIFICANT CHANGES TO THE INTERNATIONAL PLUMBING CODE\u00ae <\/td>\n<\/tr>\n
13<\/td>\nPART 1: INTERNATIONAL PLUMBING CODE CHAPTERS 1 THROUGH 15 <\/td>\n<\/tr>\n
16<\/td>\n202 DEFINITION OF COPPER ALLOY <\/td>\n<\/tr>\n
17<\/td>\n202 DEFINITION OF PUBLIC AND PRIVATE
FIGURE: PUBLIC VERSUS PRIVATE USES <\/td>\n<\/tr>\n
18<\/td>\n202 DEFINITION OF WATER DISPENSER
IMAGE: BOTTLED WATER UNIT IS NOT A WATER DISPENSER <\/td>\n<\/tr>\n
19<\/td>\n308.9 BUNDLED HOT WATER PIPING INSULATION
FIGURE: HOT WATER PIPING BUNDLED WITH COLD WATER PIPING <\/td>\n<\/tr>\n
20<\/td>\n403.1.1 FIXTURE QUANTITY CALCULATIONS FOR MULTIPLE USER FACILITIES <\/td>\n<\/tr>\n
22<\/td>\n403.1.2 FIXTURES IN SINGLE-USER TOILET ROOMS COUNT TOWARDS TOTAL REQUIRED QUANTITIES
IMAGE: FIXTURES IN ALL SINGLE-USER TOILET ROOMS COUNT TOWARD TOTAL REQUIRED <\/td>\n<\/tr>\n
24<\/td>\n403.2 MULTIPLE-USER NONSEPARATED TOILET FACILITIES
FIGURE: MULTIPLE-USER NONSEPARATED TOILET FACILITIES <\/td>\n<\/tr>\n
26<\/td>\n403.3.1, 403.5 FACILITIES AND DRINKING FOUNTAINS ON ACCESSIBLE ROUTES
FIGURE: ACCESSIBLE ROUTES <\/td>\n<\/tr>\n
27<\/td>\n403.3.3 GROUP S TOILET FACILITY LOCATION
FIGURE: STORAGE FACILITY WITH TOILET FACILITY AT OFFICE <\/td>\n<\/tr>\n
29<\/td>\n403.6 SERVICE SINK LOCATION
FIGURE: LOCATION OF SERVICE SINK <\/td>\n<\/tr>\n
30<\/td>\n405.4.3 WALL HUNG FIXTURE CARRIER STANDARD FOR WATER CLOSETS
FIGURE: WALL-HUNG WATER CLOSET CARRIER <\/td>\n<\/tr>\n
31<\/td>\n407.2 BATHTUBS ARE NOT REQUIRED TO HAVE OVERFLOW OUTLETS
FIGURE: OVERFLOW NOT REQUIRED <\/td>\n<\/tr>\n
32<\/td>\n410.3.2 QUANTITIES OF STANDING VERSUS WHEELCHAIR DRINKING FOUNTAINS
FIGURE: DRINKING FOUNTAINS FOR ACCESSIBLE DESIGN <\/td>\n<\/tr>\n
34<\/td>\n410.4 DRINKING FOUNTAIN SUBSTITUTION USING WATER DISPENSERS
IMAGE: DRINKING FOUNTAIN SUBSTITUTION USING WATER DISPENSERS <\/td>\n<\/tr>\n
35<\/td>\n411.3 WATER HEATERS FOR EMERGENCY SHOWERS AND EYE WASH STATIONS
IMAGE: EMERGENCY SHOWER WATER HEATER <\/td>\n<\/tr>\n
36<\/td>\n412.3 SHOWER CONTROL VALVES TO BE RATED FOR THE INSTALLED SHOWER HEAD
IMAGE: SHOWER VALVE RATED FOR LOWER FLOW SHOWER HEAD <\/td>\n<\/tr>\n
37<\/td>\n412.5 METHODS FOR LIMITING WATER TEMPERATURE DISCHARGED TO BATHTUBS
FIGURE: TEMPERATURE LIMITING FOR BATHTUBS <\/td>\n<\/tr>\n
38<\/td>\n412.10 METHODS FOR TEMPERATURE LIMITATION AT HEAD SHAMPOO SINKS AND FOOTBATHS
IMAGE: TEMPERATURE LIMITING FOR HEAD SHAMPOO SINKS <\/td>\n<\/tr>\n
39<\/td>\n419.5 TEMPERED WATER FOR PUBLIC HAND-WASHING LAVATORIES
IMAGE: A CSA B125.3 DEVICE IS NO LONGER ACCEPTABLE FOR TEMPERATURE COMPENSATING <\/td>\n<\/tr>\n
40<\/td>\n421.3.1 STANDARD FOR SHOWER WASTE FITTINGS
IMAGE: SHOWER DRAIN TO COMPLY WITH STANDARD <\/td>\n<\/tr>\n
41<\/td>\n501.2 ASSE 1017 TEMPERATURE ACTUATED MIXING VALVES
IMAGE: “MASTER THERMOSTATIC” MIXING VALVE DOES NOT EXIST <\/td>\n<\/tr>\n
42<\/td>\n602.3.5 POTABLE WATER PUMPS TO COMPLY WITH NSF 61
IMAGE: NSF 61-COMPLIANT POTABLE WATER PUMP <\/td>\n<\/tr>\n
43<\/td>\n605.1.12.3, 605.13.6 SOLDER AND FLUX TO CONFORM TO NSF 61
IMAGE: NSF 61-COMPLIANT SOLDER AND FLUX <\/td>\n<\/tr>\n
44<\/td>\n606.1 INDIVIDUAL TENANT WATER SHUT-OFF VALVE
FIGURE: INDIVIDUAL TENANT SHUT-OFF VALVES <\/td>\n<\/tr>\n
45<\/td>\n607.1.1, 607.1.2 WATER HEATERS PROVIDING TEMPERED WATER TO FIXTURES
IMAGE: WATER HEATER FOR TEMPERED WATER <\/td>\n<\/tr>\n
46<\/td>\n608.15.2.1 DISCHARGE FROM BACKFLOW PREVENTER RELIEF OPENING
IMAGE; WASTE RECEPTOR FOR BACKFLOW PREVENTER <\/td>\n<\/tr>\n
47<\/td>\n608.17.2 BACKFLOW DEVICE FOR LOW HAZARD BOILER APPLICATIONS
IMAGE: PRESSURE REDUCING VALVE\/BACKFLOW PREVENTER FOR BOILER <\/td>\n<\/tr>\n
48<\/td>\n609.2 TWO WATER SERVICE PIPES FOR GROUP I-2, CONDITION 2 HEALTHCARE FACILITIES
IMAGE: HEALTHCARE FACILITY WATER SERVICE PIPES <\/td>\n<\/tr>\n
49<\/td>\n609.2.1 TRACER WIRE FOR BURIED NONMETALLIC WATER SERVICE PIPING
IMAGE: TRACER REQUIRED FOR UNDERGROUND NONMETALLIC WATER SERVICE PIPE <\/td>\n<\/tr>\n
50<\/td>\nTABLE 702.3 ABS BUILDING SEWER PIPE STANDARD
IMAGE: NEW STANDARD FOR ABS SEWER PIPE <\/td>\n<\/tr>\n
51<\/td>\n705.2.4, 705.10.4 PVC AND ABS PUSH-FIT DWV FITTINGS
IMAGE: PUSH-FIT DRAINAGE FITTINGS <\/td>\n<\/tr>\n
52<\/td>\n708.1.6 REMOVABLE FIXTURE TRAPS SERVING AS CLEANOUTS
IMAGE: REMOVABLE TRAP AS CLEANOUT <\/td>\n<\/tr>\n
53<\/td>\n717, 718 METHODS FOR RESTORING BUILDING SEWER PIPING <\/td>\n<\/tr>\n
54<\/td>\nIMAGE: BUILDING SEWER RESTORATION <\/td>\n<\/tr>\n
56<\/td>\n903.1.3 PROTECTED OUTDOOR VENT TERMINATION METHOD
IMAGE: ARCHITECTURAL SHROUD <\/td>\n<\/tr>\n
57<\/td>\n915.1 FOOD WASTE DISPOSERS ON COMBINATION WASTE AND VENT SYSTEMS
IMAGE: FOOD WASTE DISPOSER ON CWV SYSTEM <\/td>\n<\/tr>\n
58<\/td>\n1002.1 DIRECT CONNECTION TO HYDROMECHANICAL GREASE INTERCEPTOR
IMAGE: DIRECT CONNECTION TO HYDROMECHANICAL INTERCEPTOR PERMITTED <\/td>\n<\/tr>\n
60<\/td>\n1002.4.1.5 FIXTURE DRAINS SERVING AS A TRAP PRIMING METHOD
IMAGE: FIXTURE DRAIN PERMITTED TO SERVE AS TRAP PRIMING METHOD <\/td>\n<\/tr>\n
61<\/td>\n1102.6 ROOF DRAINS TO BE TESTED AND RATED FOR FLOW
IMAGE: PRODUCT TESTING AND RATING FOR FLOW REQUIRED <\/td>\n<\/tr>\n
62<\/td>\n1106.2.1 RAINFALL RATE CONVERSION METHOD
EQUATION 11-1
IMAGE: A NEW EQUATION CONVERTS INCHES PER HOUR OF RAINFALL TO GALLONS PER MINUTE FLOW RATE <\/td>\n<\/tr>\n
63<\/td>\n1202.1 NONFLAMMABLE MEDICAL GAS SYSTEMS
IMAGE: NONFLAMMABLE MEDICAL GAS SYSTEM INSTALLATION <\/td>\n<\/tr>\n
64<\/td>\n1301.1 NONPOTABLE RAINWATER STANDARD ALTERNATIVE
IMAGE: RAINWATER STORAGE SYSTEM <\/td>\n<\/tr>\n
66<\/td>\nSIGNIFICANT CHANGES TO THE INTERNATIONAL MECHANICAL CODE\u00ae <\/td>\n<\/tr>\n
67<\/td>\nPART 2: INTERNATIONAL MECHANICAL CODE CHAPTERS 1 THROUGH 15 <\/td>\n<\/tr>\n
69<\/td>\n307.2.1.1 CONDENSATE DISCHARGE
FIGURE: ALLOWABLE RECEPTORS FOR CONDENSATE <\/td>\n<\/tr>\n
71<\/td>\n401.2, 403.1 MECHANICAL VENTILATION FOR DWELLING UNITS
IMAGE: GROUP R-2 APARTMENT BUILDING <\/td>\n<\/tr>\n
73<\/td>\n401.4, 501.3.1 INTAKE OPENING AND EXHAUST OUTLET LOCATIONS <\/td>\n<\/tr>\n
74<\/td>\nIMAGE: COMBINATION EXHAUST AND INTAKE AIR FITTING <\/td>\n<\/tr>\n
75<\/td>\nTABLE 403.3.1.1 RECIRCULATION OF MECHANICAL EXHAUST PROHIBITED
FIGURE: WHEEL-TYPE ENERGY RECOVERY VENTILATION <\/td>\n<\/tr>\n
77<\/td>\n403.3.1.3 DEMAND CONTROLLED VENTILATION <\/td>\n<\/tr>\n
78<\/td>\n403.3.2.1 OUTDOOR AIR FOR DWELLING UNITS
EQUATION 4-9 <\/td>\n<\/tr>\n
80<\/td>\n502.20 MANICURE AND PEDICURE STATION EXHAUST SYSTEM
IMAGE: MANICURE AND PEDICURE STATION EXHAUST SYSTEM
IMAGE: MANICURE AND PEDICURE STATIONS <\/td>\n<\/tr>\n
82<\/td>\n504.4.1 TERMINATION LOCATION FOR DRYER EXHAUST
FIGURE: DRYER EXHAUST TERMINAL MINIMUM CLEARANCE TO OPERABLE OPENINGS AND SOFFIT VENTS <\/td>\n<\/tr>\n
83<\/td>\n506.3.7 FACTORY-BUILT GREASE DUCT SLOPE
IMAGE: GREASE DUCT <\/td>\n<\/tr>\n
84<\/td>\nIMAGE: GREASE DUCT <\/td>\n<\/tr>\n
85<\/td>\n507.1 SMOKER OVENS WITH INTEGRAL EXHAUST
IMAGE: SMOKER OVEN WITH INTEGRAL EXHAUST <\/td>\n<\/tr>\n
86<\/td>\nIMAGE: SMOKER OVEN WITH INTEGRAL EXHAUST <\/td>\n<\/tr>\n
88<\/td>\n514.2 ENERGY RECOVERY VENTILATION SYSTEMS
IMAGE: COMMERCIAL KITCHEN OVENS <\/td>\n<\/tr>\n
89<\/td>\nIMAGE: COMMERCIAL KITCHEN OVENS <\/td>\n<\/tr>\n
90<\/td>\n602.2.1.8 PIPE AND DUCT INSULATION WITHIN PLENUMS
IMAGE: PIPE INSULATION <\/td>\n<\/tr>\n
91<\/td>\nIMAGE: DUCT INSULATION <\/td>\n<\/tr>\n
92<\/td>\n607.5.2 DUCT PENETRATIONS OF FIRE BARRIERS <\/td>\n<\/tr>\n
93<\/td>\nFIGURE: DUCT PENETRATION OF FIRE BARRIER <\/td>\n<\/tr>\n
95<\/td>\n607.5.5 SUBDUCTS PENETRATING SHAFT ENCLOSURES
FIGURE: SUBDUCTS PENETRATING SHAFT ENCLOSURES <\/td>\n<\/tr>\n
97<\/td>\n608.1, 403.3.1.5 VENTILATION AIR DISTRIBUTION
IMAGE: MEANS TO ADJUST AIRFLOW TO BALANCE VENTILATION AIR DISTRIBUTION <\/td>\n<\/tr>\n
98<\/td>\n801.21 BLOCKED VENT SWITCH FOR OIL-FIRED APPLIANCES
FIGURE: BLOCKED VENT SWITCH FOR OIL-FIRED APPLIANCES <\/td>\n<\/tr>\n
99<\/td>\n905.1 WOOD-BURNING RESIDENTIAL HYDRONIC HEATERS
FIGURE: WOOD-BURNING RESIDENTIAL HYDRONIC HEATER <\/td>\n<\/tr>\n
100<\/td>\n929 UNVENTED ALCOHOL FUEL-BURNING DECORATIVE APPLIANCES
IMAGE: UNVENTED ALCOHOL FUEL-BURNING DECORATIVE APPLIANCE <\/td>\n<\/tr>\n
101<\/td>\n1101 THROUGH 1108 AMMONIA REFRIGERATION SYSTEMS
IMAGE: AMMONIA REFRIGERATION SYSTEMS <\/td>\n<\/tr>\n
102<\/td>\nTABLE 103.1 REFRIGERANT CLASSIFICATION, AMOUNT AND OEL <\/td>\n<\/tr>\n
104<\/td>\n1105.9 MACHINERY ROOM MEANS OF EGRESS
FIGURE: MACHINERY ROOM MEANS OF EGRESS <\/td>\n<\/tr>\n
105<\/td>\nIMAGE: MACHINERY ROOM EGRESS DOOR <\/td>\n<\/tr>\n
106<\/td>\n1107 THROUGH 1110 REFRIGERANT PIPING
IMAGE: REFRIGERATION PIPING <\/td>\n<\/tr>\n
107<\/td>\nTABLE 1107.4 REFRIGERANT PIPE
TABLE 1107.5 REFRIGERANT PIPE FITTINGS
TABLE 1107.5.1 COPPER BRAZED SWAGED CUP DEPTHS <\/td>\n<\/tr>\n
108<\/td>\nTABLE 1109.3.2 SHAFT VENTILATION VELOCITY <\/td>\n<\/tr>\n
109<\/td>\nIMAGE: COPPER REFRIGERATION PIPING <\/td>\n<\/tr>\n
112<\/td>\nSIGNIFICANT CHANGES TO THE INTERNATIONAL FUEL GAS CODE\u00ae <\/td>\n<\/tr>\n
113<\/td>\nPART 3: INTERNATIONAL FUEL GAS CODE CHAPTERS 1 THROUGH 8 <\/td>\n<\/tr>\n
115<\/td>\n202 DEFINITION OF POINT OF DELIVERY
FIGURE: SERVICE METER ASSEMBLY AND POINT OF DELIVERY <\/td>\n<\/tr>\n
117<\/td>\n307.2 CONCEALED CONDENSATE PIPING
FIGURE: LABELING OF CONCEALED CONDENSATE PIPING TERMINATION <\/td>\n<\/tr>\n
119<\/td>\n402.7, 202 PRESS-CONNECT JOINT
IMAGE: PRESS-CONNECT FITTING WITH BITE RING USED WITH SCH 40 AND SCH 10 STEEL PIPE <\/td>\n<\/tr>\n
120<\/td>\n403.8.3 THREADED JOINT SEALING
IMAGE: THREADED JOINT PIPE TAPE <\/td>\n<\/tr>\n
121<\/td>\n404.5 FITTINGS IN CONCEALED LOCATIONS
IMAGE: THREADED FITTING PERMITTED IN CONCEALED SPACES <\/td>\n<\/tr>\n
122<\/td>\n503.5.6.1 CHIMNEY LINING
FIGURE: CODE-COMPLIANT CHIMNEY LINING REQUIRED FOR REPLACEMENT APPLIANCE <\/td>\n<\/tr>\n
124<\/td>\n503.8 VENTING SYSTEM TERMINAL CLEARANCES <\/td>\n<\/tr>\n
125<\/td>\nFIGURE 503.8 THROUGH THE WALL VENT TERMINAL CLEARANCES <\/td>\n<\/tr>\n
126<\/td>\nTABLE 503.8 THROUGH-THE-WALL VENT TERMINAL CLEARANCES <\/td>\n<\/tr>\n
128<\/td>\n503.10.7 VENT CONNECTOR JUNCTIONS <\/td>\n<\/tr>\n
129<\/td>\nFIGURE: VENT CONNECTORS JOINED BY TEE OR WYE FITTINGS <\/td>\n<\/tr>\n
130<\/td>\n614.7 CLOTHES DRYER MAKEUP AIR
FIGURE: MAKEUP AIR FOR A CLOSET INSTALLATION OF A DRYER <\/td>\n<\/tr>\n
131<\/td>\n618.6 RETURN AIR FROM MECHANICAL ROOM
FIGURE: PROHIBITED INSTALLATION <\/td>\n<\/tr>\n
133<\/td>\n623.2 COMMERCIAL COOKING APPLIANCES
IMAGE: COMMERCIAL-TYPE DOMESTIC RANGE <\/td>\n<\/tr>\n
136<\/td>\nTELEWORK WITH ICC DIGITAL CODES PREMIUM <\/td>\n<\/tr>\n
137<\/td>\nPROCTORED REMOTE ONLINE TESTING OPTION (PRONTO\u2122) <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

Significant Changes to the IPC\u00ae, IMC\u00ae, and IFGC\u00ae, 2021 Edition<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
ICC<\/b><\/a><\/td>\n2021<\/td>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":369509,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[2670],"product_tag":[],"class_list":{"0":"post-369500","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-icc","8":"first","9":"instock","10":"sold-individually","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/369500","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/369509"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=369500"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=369500"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=369500"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}