{"id":80329,"date":"2024-10-17T18:43:16","date_gmt":"2024-10-17T18:43:16","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/ieee-c2-1996\/"},"modified":"2024-10-24T19:43:08","modified_gmt":"2024-10-24T19:43:08","slug":"ieee-c2-1996","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/ieee\/ieee-c2-1996\/","title":{"rendered":"IEEE C2 1996"},"content":{"rendered":"

New IEEE Standard – Active. This standard covers basic provisions for safeguarding of persons from hazards arising from the installation,operation, or maintenance of 1) conductors and equipment in electric supply stations, and 2) overhead and underground electric supply and communication lines. It also includes work rules for the construction, maintenance, and operation of electric supply and communication lines and equipment. The standard is applicable to the systems and equipment operated by utilities, or similar systems and equipment, of an industrial establishment or complex under the control of qualified persons. This standard consists of the introduction, definitions, grounding rules, list of referenced and bibliographic documents, and Parts 1, 2, 3, and 4 of the 1997 Edition of the National Electrical Safety Code.<\/p>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
1<\/td>\nTitle Page (1997 NESC) <\/td>\n<\/tr>\n
35<\/td>\n01 Introduction to the National Electrical Safety Code\u00ae
010. Purpose
011. Scope
012. General Rules
013. Application <\/td>\n<\/tr>\n
36<\/td>\n014. Waiver
015. Intent
016. Effective Date
017. Units of Measure <\/td>\n<\/tr>\n
38<\/td>\n02 Definitions of Special Terms <\/td>\n<\/tr>\n
47<\/td>\n03 References <\/td>\n<\/tr>\n
49<\/td>\n09 Grounding Methods for Electric Supply and Communications Facilities
90. Purpose
91. Scope
92. Point of Connection of Grounding Conductor <\/td>\n<\/tr>\n
51<\/td>\n93. Grounding Conductor and Means of Connection <\/td>\n<\/tr>\n
54<\/td>\n94. Grounding Electrodes <\/td>\n<\/tr>\n
56<\/td>\n95. Method of Connection to Electrode <\/td>\n<\/tr>\n
57<\/td>\n96. Ground Resistance Requirements
97. Separation of Grounding Conductors <\/td>\n<\/tr>\n
58<\/td>\n98. Number 98 not used in this edition. <\/td>\n<\/tr>\n
59<\/td>\n99. Additional Requirements for Communication Apparatus <\/td>\n<\/tr>\n
61<\/td>\n10 Purpose and Scope of Rules
100. Purpose
101. Scope <\/td>\n<\/tr>\n
62<\/td>\n11 Protective Arrangements in Electric Supply Stations
110. General Requirements <\/td>\n<\/tr>\n
64<\/td>\n111. Illumination
112. Floors, Floor Openings, Passageways, and Stairs <\/td>\n<\/tr>\n
67<\/td>\n113. Exits
114. Fire-Extinguishing Equipment <\/td>\n<\/tr>\n
68<\/td>\n12 Installation and Maintenance of Equipment
120. General Requirements
121. Inspections
122. Guarding Shaft Ends, Pulleys, Belts, and Suddenly Moving Parts
123. Protective Grounding <\/td>\n<\/tr>\n
69<\/td>\n124. Guarding Live Parts <\/td>\n<\/tr>\n
78<\/td>\n125. Working Space About Electric Equipment <\/td>\n<\/tr>\n
79<\/td>\n126. Equipment for Work on Energized Parts
127. Classified Locations <\/td>\n<\/tr>\n
81<\/td>\n128. Identification
129. Mobile Hydrogen Equipment <\/td>\n<\/tr>\n
82<\/td>\n13 Rotating Equipment
130. Speed Control and Stopping Devices
131. Motor Control
132. Number 132 not used in this edition.
133. Short-Circuit Protection <\/td>\n<\/tr>\n
83<\/td>\n14 Storage Batteries
140. General
141. Location
142. Ventilation
143. Racks
144. Floors in Battery Areas
145. Illumination for Battery Areas
146. Service Facilities
147. Number 147 not used in this edition. <\/td>\n<\/tr>\n
84<\/td>\n15 Transformers and Regulators
150. Current-Transformer Secondary Circuits Protection When Exceeding 600 V
151. Grounding Secondary Circuits of Instrument Transformers
152. Location and Arrangement of Power Transformers and Regulators
153. Short-Circuit Protection of Power Transformers <\/td>\n<\/tr>\n
86<\/td>\n16 Conductors
160. Application
161. Electrical Protection
162. Mechanical Protection and Support
163. Isolation
164. Conductor Terminations <\/td>\n<\/tr>\n
87<\/td>\n17 Circuit Breakers, Reclosers, Switches, and Fuses
170. Arrangement
171. Application
172. Circuit Breakers, Reclosers, and Switches Containing Oil
173. Switches and Disconnecting Devices
174. Disconnection of Fuses <\/td>\n<\/tr>\n
88<\/td>\n18 Switchgear and Metal-Enclosed Bus
180. Switchgear Assemblies <\/td>\n<\/tr>\n
89<\/td>\n181. Metal-Enclosed Bus <\/td>\n<\/tr>\n
93<\/td>\n20 Purpose, Scope, and Application of Rules
200. Purpose
201. Scope
202. Application of Rules <\/td>\n<\/tr>\n
94<\/td>\n21 General Requirements
210. Referenced Sections
211. Number 211 not used in this edition.
212. Induced Voltages
213. Accessibility
214. Inspection and Tests of Lines and Equipment <\/td>\n<\/tr>\n
95<\/td>\n215. Grounding of Circuits, Supporting Structures, and Equipment <\/td>\n<\/tr>\n
96<\/td>\n216. Arrangement of Switches
217. General <\/td>\n<\/tr>\n
97<\/td>\n218. Tree Trimming <\/td>\n<\/tr>\n
98<\/td>\n22 Relations Between Various Classes of Lines and Equipment
220. Relative Levels <\/td>\n<\/tr>\n
99<\/td>\n221. Avoidance of Conflict
222. Joint Use of Structures <\/td>\n<\/tr>\n
100<\/td>\n223. Communications Protective Requirements
224. Communication Circuits Located Within the Supply Space and Supply Circuits Located Within th… <\/td>\n<\/tr>\n
101<\/td>\n225. Electric Railway Construction <\/td>\n<\/tr>\n
103<\/td>\n23 Clearances
230. General <\/td>\n<\/tr>\n
105<\/td>\n231. Clearances of Supporting Structures From Other Objects <\/td>\n<\/tr>\n
106<\/td>\n232. Vertical Clearances of Wires, Conductors, Cables, and Equipment Above Ground, Roadway, Rail,… <\/td>\n<\/tr>\n
118<\/td>\n233. Clearances Between Wires, Conductors, and Cables Carried on Different Supporting Structures <\/td>\n<\/tr>\n
128<\/td>\n234. Clearance of Wires, Conductors, Cables, and Equipment From Buildings, Bridges, Rail Cars, Sw… <\/td>\n<\/tr>\n
149<\/td>\n235. Clearance for Wires, Conductors, or Cables Carried on the Same Supporting Structure <\/td>\n<\/tr>\n
163<\/td>\n236. Climbing Space <\/td>\n<\/tr>\n
166<\/td>\n237. Working Space <\/td>\n<\/tr>\n
168<\/td>\n238. Vertical Clearance Between Certain Communications and Supply Facilities Located on the Same … <\/td>\n<\/tr>\n
170<\/td>\n239. Clearance of Vertical and Lateral Facilities From Other Facilities and Surfaces on the Same … <\/td>\n<\/tr>\n
176<\/td>\n24 Grades of Construction
240. General
241. Application of Grades of Construction to Different Situations
242. Grades of Construction for Conductors <\/td>\n<\/tr>\n
181<\/td>\n243. Grades of Construction for Line Supports <\/td>\n<\/tr>\n
182<\/td>\n25 Loadings for Grades B and C
250. General Loading Requirements and Maps <\/td>\n<\/tr>\n
186<\/td>\n251. Conductor Loading <\/td>\n<\/tr>\n
187<\/td>\n252. Loads on Line Supports <\/td>\n<\/tr>\n
188<\/td>\n253. Overload Factors for Structures, Crossarms, Guys, Foundations, and Anchors <\/td>\n<\/tr>\n
191<\/td>\n26 Strength Requirements
260. General (see also Section 20)
261. Grades B and C Construction <\/td>\n<\/tr>\n
199<\/td>\n262. Number 262 not used in this edition.
263. Grade N Construction <\/td>\n<\/tr>\n
201<\/td>\n264. Guying and Bracing <\/td>\n<\/tr>\n
203<\/td>\n27 Line Insulation
270. Application of Rule
271. Material and Marking
272. Ratio of Flashover to Puncture Voltage
273. Insulation Level
274. Factory Tests
275. Special Insulator Applications <\/td>\n<\/tr>\n
204<\/td>\n276. Protection Against Arcing and Other Damage
277. Mechanical Strength of Insulators
278. Aerial Cable Systems <\/td>\n<\/tr>\n
205<\/td>\n279. Guy and Span Insulators <\/td>\n<\/tr>\n
206<\/td>\nSection number 28 not used in this edition. <\/td>\n<\/tr>\n
207<\/td>\n30 Purpose, Scope, and Application of Rules
300. Purpose
301. Scope
302. Application of Rules <\/td>\n<\/tr>\n
208<\/td>\n31 General Requirements Applying to Underground Lines
310. Referenced Sections
311. Installation and Maintenance
312. Accessibility
313. Inspection and Tests of Lines and Equipment
314. Grounding of Circuits and Equipment <\/td>\n<\/tr>\n
209<\/td>\n315. Communications Protective Requirements
316. Induced Voltage <\/td>\n<\/tr>\n
210<\/td>\n32 Underground Conduit Systems
320. Location <\/td>\n<\/tr>\n
211<\/td>\n321. Excavation and Backfill
322. Ducts and Joints <\/td>\n<\/tr>\n
212<\/td>\n323. Manholes, Handholes, and Vaults <\/td>\n<\/tr>\n
216<\/td>\n33 Supply Cable
330. General
331. Sheaths and Jackets
332. Shielding
333. Cable Accessories and Joints <\/td>\n<\/tr>\n
217<\/td>\n34 Cable in Underground Structures
340. General
341. Installation <\/td>\n<\/tr>\n
218<\/td>\n342. Grounding and Bonding
343. Fireproofing
344. Communication Cables Containing Special Supply Circuits <\/td>\n<\/tr>\n
220<\/td>\n35 Direct-Buried Cable
350. General
351. Location and Routing <\/td>\n<\/tr>\n
226<\/td>\n36 Risers
360. General
361. Installation
362. Pole Risers\u2014Additional Requirements
363. Pad-Mounted Installations <\/td>\n<\/tr>\n
227<\/td>\n37 Supply Cable Terminations
370. General
371. Support at Terminations
372. Identification
373. Clearances in Enclosures or Vaults
374. Grounding <\/td>\n<\/tr>\n
228<\/td>\n38 Equipment
380. General
381. Design <\/td>\n<\/tr>\n
229<\/td>\n382. Location in Underground Structures
383. Installation
384. Grounding
385. Identification <\/td>\n<\/tr>\n
230<\/td>\n39 Installation in Tunnels
390. General
391. Environment <\/td>\n<\/tr>\n
231<\/td>\n40 Purpose and Scope
400. Purpose
401. Scope
402. Referenced Sections <\/td>\n<\/tr>\n
232<\/td>\n41 Supply and Communications Systems–Rules for Employers
410. General Requirements
411. Protective Methods and Devices <\/td>\n<\/tr>\n
234<\/td>\n42 General Rules for Employees
420. Personal General Precautions <\/td>\n<\/tr>\n
237<\/td>\n421. General Operating Routines <\/td>\n<\/tr>\n
238<\/td>\n422. Overhead Line Operating Procedures
423. Underground Line Operating Procedures <\/td>\n<\/tr>\n
240<\/td>\n43 Additional Rules for Communications Employees
430. General
431. Approach to Energized Conductors or Parts
432. Joint-Use Structures
433. Attendant on Surface at Joint-Use Manhole
434. Sheath Continuity <\/td>\n<\/tr>\n
241<\/td>\n44 Additional Rules for Supply Employees
440. General
441. Energized Conductors or Parts <\/td>\n<\/tr>\n
250<\/td>\n442. Switching Control Procedures <\/td>\n<\/tr>\n
251<\/td>\n443. Work on Energized Lines and Equipment <\/td>\n<\/tr>\n
253<\/td>\n444. De-energizing Equipment or Lines to Protect Employees <\/td>\n<\/tr>\n
255<\/td>\n445. Protective Grounds
446. Live Work <\/td>\n<\/tr>\n
257<\/td>\nAppendix A: Uniform System of Clearances Adopted in the 1990 Edition <\/td>\n<\/tr>\n
268<\/td>\nAppendix B: Bibliography <\/td>\n<\/tr>\n
271<\/td>\nIndex <\/td>\n<\/tr>\n
296<\/td>\nWorking Group Assignments <\/td>\n<\/tr>\n
298<\/td>\nAmendments <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

1997 National Electric Safety Code (NESC)<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
IEEE<\/b><\/a><\/td>\n1996<\/td>\n298<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":80330,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[2644],"product_tag":[],"class_list":{"0":"post-80329","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-ieee","8":"first","9":"instock","10":"sold-individually","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/80329","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/80330"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=80329"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=80329"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=80329"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}