API RP 1113-2007 (R2012)

$39.00

Developing a Pipeline Supervisory Control Center

Published By Publication Date Number of Pages
API 2007 22
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

A pipeline supervisory control center is a facility where the function of centralized monitoring and controlling of a pipeline system occurs.

This document focuses on the design aspects that may be considered appropriate for developing or revamping a control center. There are five sections (Sections 2 through 6) that provide lists of general considerations.

This document is not all-inclusive. It is intended to cover best practices and provide guidelines for developing a control center only. It does not dictate operational control philosophy or overall SCADA system functionality.

This document was created by an API Cybernetics Subcommittee task force, based on industry practices used on liquid pipeline SCADA systems. The document is intended to apply to control centers for liquids pipelines; however, many of the considerations may also apply to gas control center design.

1.2 Purpose

The purpose of this document is to assist the SCADA system designer in identifying issues relevant to the development or redevelopment of a control center.

It is recognized that each pipeline company has unique operating philosophies and SCADA systems; therefore, not all elements of this document may be applicable.

For example:

— Some pipeline control centers are a combination of several different SCADA systems.

— Some of these SCADA systems may not have the developer tools necessary to implement the consideration.

— Some operators may have existing control center design philosophies/techniques that bridge over into unique operating philosophies.

Regulatory and individual company standards are not addressed in this document.

1.3 How to Use This Document

The decisions to consider points that are written in Sections 2 through 6, do not need to be considered in the order they are presented (i.e. in numerical order). The lists are not all-inclusive but should help stimulate further, detailed analysis. The reader should have a good working knowledge of pipeline operations and control center design philosophies/ techniques, and may have to refer to other documents for background or additional information. Any references to SCADA and control center security have been removed and the reader should refer to API 1164 for best practices and guidelines.

API RP 1113-2007 (R2012)
$39.00