ASTM-F1277:2002 Edition
$40.63
F1277-02 Standard Test Method for Determination of Leachable Chloride in Packing and Gasketing Materials by Ion-Selective Electrode Technique
Published By | Publication Date | Number of Pages |
ASTM | 2002 | 4 |
1.1 This test method provides for the measurement of chloride ion leached from flexible graphite, asbestos, or paper-based packing and gasketing materials. Samples containing 7 to 6700 g Cl – /g sample can be analyzed with this procedure. The upper concentration limit can be extended by dilution of the test solution.
1.2 It is the responsibility of the analyst to ensure the validity of this test method for other packing or gasketing materials.
1.3 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. A specific warning statement is given in 8.3.
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | Scope Referenced Documents Summary of Test Method Significance and Use Interferences |
2 | Apparatus Preparation of Reference Materials and Samples Reagents and Materials |
3 | Preparation of Apparatus Calibration Procedure |
4 | Calculation of Results Precision and Bias Keywords TABLE 1 |