BS EN 60598-2-25:1995:2006 Edition
$102.76
Luminaires. Particular requirements – Luminaires for use in clinical areas of hospitals and health care buildings
Published By | Publication Date | Number of Pages |
BSI | 2006 | 18 |
This section of IEC 60598-2 details specific requirements for luminaires for use with tungsten filament, fluorescent and other discharge lamps on supply voltages not exceeding 1 000 V for use in clinical areas in which medical treatment, examination and medical care takes place in hospitals and health care buildings.
�This standard does not apply to medical electrical equipment, as defined in IEC 60601-1 and IEC 60606-2-41, containing a light source.®I
�NOTE 1 Medical electrical equipment may have luminaires for medical examination purposes which are covered by IEC 60601-1 and IEC 60601-2-41.®I
This standard does not apply to luminaires for emergency lighting and luminaires for general illumination in non-clinical areas (e.g. offices).
NOTE 2 For these luminaire types, reference should be made to other sections of IEC 60598-2.
This standard does not apply to luminaires or parts of luminaires which are designed to be sterilized by the autoclave process and luminaires for operating tables.
PDF Catalog
PDF Pages | PDF Title |
---|---|
3 | Contents |
6 | Foreword Foreword to amendment A1 Contents |
7 | 25.1.1 Scope 25.1.2 Normative references 25.2 General test requirements 25.3 Definitions bedded area enclosed luminaire |
8 | bedded area luminaire bedhead luminaire night light luminaire hospital system general examination luminaire hand-held inspection luminaire rewirable hand-held inspection luminaire non-rewirable hand-held inspection luminaire 25.4 Classification According to the type of protection against electric shock, hand-held inspection luminaires shall… 25.5Marking Hospital system shall have the service outlets clearly and indelibly marked. Any warning notices … |
9 | 25.6 Construction Components Mechanical strength |
10 | Focus and dimming controls 25.7 Creepage distances and clearances |
11 | 25.8 Provision for earthing 25.9 Terminals 25.10 External and internal wiring Supply cords for luminaires incorporating a fluorescent lamp shall not incorporate a resistance w… Hand-held inspection luminaires shall not incorporate socket outlets or appliance inlets and shal… Flexible cables and cords of hand-held inspection and portable general examination luminaires sha… For cord anchorage for rewirable hand-held inspection luminaires and portable general examination… |
12 | 25.11 Protection against electric shock For hand-held inspection luminaires it shall not be possible to remove by hand parts which preven… Luminaires or parts of luminaires which are within�2�m from the floor and which are intended to b… 25.12 Endurance test and thermal tests For luminaires provided with an automatic cord reel, one-third of the cable or cord is unrolled. … For hand-held inspection luminaires and independent ballasts used with these luminaires having ex… Rubber hand-held inspection luminaires and rubber cases of independent controlgear shall be aged … The thermal tests representing normal operation and abnormal operation of� The limiting temperature of�70�°C for natural rubber in Table�12.2 of�IEC�60598-1 does not apply�… |
13 | 25.13 Resistance to dust, solid objects and moisture Protective glasses, translucent covers and similar parts shall be removed before the humidity tre… 25.14 Insulation resistance and electric strength 25.15 Resistance to heat, fire and tracking |
17 | Annex ZA (normative) Normative references to international publications with their�corresponding European … |