BS ISO 14117:2012:2013 Edition

$215.11

Active implantable medical devices. Electromagnetic compatibility. EMC test protocols for implantable cardiac pacemakers, implantable cardioverter defibrillators and cardiac resynchronization devices

Published By Publication Date Number of Pages
BSI 2013 108
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

PDF Catalog

PDF Pages PDF Title
3 CVP_Secretariat_Loca
6 Foreword
7 Introduction
10 1 Scope
2 Normative references
3 Terms and definitions, symbols and abbreviations
12 4 Test requirements for the frequency band 0 Hz ≤ ƒ ≤ 3 000 MHz
4.1 General
13 4.2 Induced lead current
14 SameLvl
20 4.3 Protection from persisting malfunction attributable to ambient electromagnetic fields
30 4.4 Temporary response to continuous wave sources
33 4.5 Protection from sensing EMI as cardiac signals
35 n
43 4.6 Protection from static magnetic fields of flux density up to 1 mT
44 4.7 Protection from static magnetic fields of flux density up to 50 mT
45 4.8 Protection from AC magnetic field exposure in the range of 1 kHz to 140 kHz
46 4.9 Test requirements for the frequency range of 450 MHz ≤ ƒ ≤ 3 000 MHz
49 PrevLvl
50 5 Testing above frequency of 3 000 MHz
6 Protection of devices from EM fields encountered in a therapeutic environment
6.1 Protection of the device from damage caused by high-frequency surgical exposure
51 6.2 Protection of the device from damage caused by external defibrillators
55 7 Additional accompanying documentation
7.1 Disclosure of permanently programmable sensitivity settings
7.2 Descriptions of reversion modes
7.3 Known potential hazardous behaviour
56 Annex A
(informative)

Rationale

67 Annex B
(informative)

Rationale for test frequency ranges

72 Annex C
(informative)

Code for describing modes of implantable generators

74 Annex D
(normative)

Interface circuits

79 Annex E
(informative)

Selection of capacitor Cx

80 Annex F
(normative)

Calibration of the injection network (Figure D.5)

82 Annex G
(normative)

Torso simulator

85 Annex H
(normative)

Dipole antennas
Annex H
(normative)

Dipole antennas

87 Annex I
(normative)

Pacemaker/ICD programming settings
Annex I
(normative)

Pacemaker/ICD programming settings

89 Annex J
(normative)

Simulated cardiac signal
Annex J
(normative)

Simulated cardiac signal

90 Annex K
(normative)

Calculation of net power into dipole antenna
Annex K
(normative)

Calculation of net power into dipole antenna

94 Annex L
(informative)

Loop area calculations
Annex L
(informative)

Loop area calculations

99 Annex M
(informative)

Correlation between levels of test voltages used in this International Standard and strengths of radiated fields
Annex M
(informative)

Correlation between levels of test voltages used in this International Standard and strengths of radiated fields

105 Bibliography
Bibliography
BS ISO 14117:2012
$215.11