BS ISO 26906:2015 – TC:2020 Edition
$258.95
Tracked Changes. Hydrometry. Fishpasses at flow measurement structures
Published By | Publication Date | Number of Pages |
BSI | 2020 | 128 |
PDF Catalog
PDF Pages | PDF Title |
---|---|
75 | Foreword |
76 | Introduction |
77 | 1 Scope 2 Normative references 3 Terms and definitions |
78 | 4 Symbols |
80 | 5 Principle 6 Installation 6.1 Requirements for gauging structure and fishpass installations 6.1.1 Selection of site |
81 | 6.1.2 Installation conditions |
82 | 6.1.3 Upstream channel 6.1.4 Separate channel |
83 | 6.1.5 Downstream channel 6.1.6 Flow measurement and fishpass structures 6.1.7 Maintenance |
84 | 6.1.8 Measurement of head 6.2 Requirements specific to the fishpass 6.2.1 General |
85 | 6.2.2 Guidelines for basic parameters of fishpasses 6.2.3 Location and attraction flows 6.2.4 Downstream entry/exit to fishpass |
86 | 6.2.5 Upstream exit/entry from fishpass 7 Fishpass performance 7.1 General 7.1.1 Types 7.1.2 Fishpasses with interconnected pools 7.1.3 Fishpasses with continuous energy dissipation |
87 | 7.1.4 Calibration and discharge coefficient 7.2 Larinier super-active baffle fishpass with baffle sizes between 75 mm and 150 mm 7.2.1 Description |
88 | 7.2.2 The following features apply to the range of baffle sizes from 75 mm to 150 mm |
89 | 7.2.3 Limitations |
90 | 7.2.4 Modular flow calibration |
91 | 7.2.5 Modular limit 7.3 Pool-type fishpass with V-shaped overfalls 7.3.1 Description |
94 | 7.3.2 Determination of discharge under free flow conditions |
97 | 7.3.3 Modular limit |
98 | 7.3.4 Determination of discharge under submerged flow conditions |
99 | 7.3.5 Limitations 7.3.6 Scaling up to standard design 7.4 Dutch pool and orifice fishpass 7.4.1 Description |
101 | 7.4.2 Determination of discharge |
103 | 7.4.3 Scaling up the standard design 8 Computation of discharge 8.1 Principles |
104 | 8.2 Details 9 Uncertainties in flow determination 9.1 General |
105 | 9.2 Combining uncertainties |
106 | 9.3 Uncertainty in the discharge coefficient u*(CDe)68 for the fish-pass 9.4 Uncertainty in the effective head 9.5 Uncertainty budget 9.5.1 General |
107 | 9.5.2 Compound structures – sources of uncertainty 10 Example 10.1 Installation |
108 | 10.2 Flow conditions 10.3 Computation of discharge 10.3.1 Modularity 10.3.2 Flow over the flat-V weir |
109 | 10.3.3 Flow through the fish-pass 10.3.4 Total flow 10.3.5 Uncertainty in flow through the fish-pass |
110 | 10.3.6 Uncertainty in flow over the flat-V weir 10.3.7 Uncertainty in total flow 10.3.8 Reduction in overall uncertainty if second head gauge were to be installed upstream of the fish-pass |
111 | Annex A (informative) Introduction to measurement uncertainty |
120 | Annex B (informative) Performance guide for hydrometric equipment for use in technical standards |
124 | Bibliography |