BSI 19/30396990 DC:2019 Edition

$13.70

BS EN IEC 62990-3. Workplace atmospheres – Part 3. Gas detectors. Electrical apparatus for the detection and measurement of oxygen. Performance requirements and test methods

Published By Publication Date Number of Pages
BSI 2019 41
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

PDF Catalog

PDF Pages PDF Title
6 FOREWORD
8 INTRODUCTION
1 Scope
9 2 Normative references
3 Terms and definitions
3.1 Gas properties
10 3.2 Types of equipment
11 3.3 Sensors
12 3.4 Supply of gas to equipment
3.5 Signals and alarms
13 3.6 Times
14 3.7 Miscellaneous
4 General requirements
4.1 Introduction
4.2 Design
4.2.1 General
15 4.2.2 Indicating devices
4.2.2.1 Indicators
4.2.2.2 Display and other outputs for indication of measured values
4.2.2.3 Suppression of indication and measured values below zero
4.2.2.3.1 General
4.2.2.3.2 Type IN equipment
16 4.2.2.3.3 Type DE equipment
4.2.2.4 Indicator light
4.2.3 Alarm signals
4.2.3.1 Alarm settings
4.2.3.2 Alarm output functions
4.2.4 Fault signal
17 4.2.5 Adjustments
4.2.6 Battery-powered equipment
4.2.7 Gas detection transmitter for use with separate gas detection control units
4.2.8 Separate gas detection control units for use with gas detection transmitter(s)
18 4.2.9 Software-controlled equipment
4.2.9.1 General
4.2.9.2 Conversion errors
4.2.9.3 Special state indication
4.2.9.4 Software
4.2.9.5 Data transmission
4.2.9.6 Self-test routines
19 4.2.9.7 Functional concept
4.3 Labelling and marking
4.4 Instruction manual
21 5 Test methods
5.1 General
22 5.2 General requirements for tests
5.2.1 Samples and sequence of tests
5.2.1.1 Test samples
5.2.1.2 Sequence
5.2.1.3 Gas detection transmitters
5.2.1.4 Separate gas detection control units
5.2.2 Preparation of equipment before testing
23 5.2.3 Mask for calibration and test
5.3 Normal conditions for test
5.3.1 General
5.3.2 Test gas(es)
24 5.3.3 Flow rate for test gases
5.3.4 Power supply
5.3.5 Temperature
5.3.6 Pressure
5.3.7 Humidity
5.3.8 Acclimation time
25 5.3.9 Orientation
5.3.10 Communications options
5.3.11 Gas detection systems
5.4 Test methods and performance requirements
5.4.1 General
5.4.2 Unpowered storage
26 5.4.3 Calibration curve and repeatability
5.4.3.1 Calibration curve
5.4.3.2 Repeatability
5.4.4 Stability
5.4.4.1 Battery-powered equipment
5.4.4.2 Fixed and transportable equipment
5.4.4.3 Portable equipment
27 5.4.5 Alarm set point(s)
5.4.5.1 General
5.4.5.2 Increasing oxygen concentration (Type DE equipment only)
5.4.5.3 Increasing oxygen concentration (Type IN equipment only)
5.4.5.4 Decreasing oxygen concentration (Type DE equipment only)
5.4.6 Temperature
28 5.4.7 Pressure
5.4.8 Humidity of test gas
29 5.4.9 Air velocity
5.4.10 Flow rate
30 5.4.11 Orientation
5.4.11.1 Portable equipment
5.4.11.2 Fixed and transportable equipment
5.4.12 Vibration
5.4.12.1 Test equipment
5.4.12.2 Procedures
5.4.12.2.1 General
31 5.4.12.2.2 Procedure 1
5.4.12.2.3 Procedure 2
5.4.13 Drop test
32 5.4.14 Warm-up time
5.4.15 Time of response
33 5.4.16 Battery capacity
5.4.17 Power supply variations
34 5.4.18 Electromagnetic compatibility (EMC)
5.4.18.1 Performance criteria
5.4.18.2 Test
35 5.4.18.3 Test of DC Input Power Ports
5.4.19 Addition of sampling probe
5.4.20 Poisons and other gases
5.4.20.1 General
5.4.20.2 Equipment with electrochemical sensors
36 5.4.20.3 Equipment with zirconium dioxide (ZrO2) sensors
5.4.21 Field verification kit
5.4.22 Operation above and below the measuring range
5.4.22.1 Gas concentrations above the upper limit of the measuring range
5.4.22.1.1 Type DE equipment
5.4.22.1.2 Type IN equipment
5.4.22.2 Operation at or below the lower limit of the measuring range (Type IN equipment only)
37 5.4.23 Fault signal tests
5.4.23.1 General
5.4.23.2 Low voltage and power interruption
5.4.23.3 Field wiring faults
5.4.23.4 Digital communication fault
5.4.23.5 Measured values below zero (Type IN equipment only)
5.4.23.5.1 General
5.4.23.5.2 Procedure 1
38 5.4.23.5.3 Procedure 2
5.4.23.6 Sensor disconnection
5.4.23.7 Automatically Aspirated Equipment
5.4.24 Verification of software and digital components
39 Annex A (informative) Determination of time of response and time of recovery
A.1 Aspirated equipment
A.1.1 Test rig
A.1.2 Equipment without internal pump
A.1.3 Equipment with internal pump
40 A.2 Equipment that samples by diffusion
A.2.1 Calibration mask method
A.2.2 Diffusion or flow methods
BSI 19/30396990 DC