BSI 23/30476562 DC 2023
$24.66
BS EN IEC 63510-3-1. Household appliances network and grid connectivity – Part 3-1. Specific Data Model Mapping. SPINE and SPINE-IoT (fast track)
Published By | Publication Date | Number of Pages |
BSI | 2023 | 201 |
PDF Catalog
PDF Pages | PDF Title |
---|---|
5 | European foreword (to be replaced with IEC IS foreword) |
6 | Introduction |
7 | 1 Scope 2 Normative references 3 Terms and definitions |
12 | 4 Reader’s guide 4.1 Reading the graphics 4.1.1 General 4.1.2 Hierarchy diagram |
13 | Figure 1 — Actor overview example 4.1.3 Sequence diagram Figure 2 — Example communication sequence diagram |
14 | 4.2 Finding the right information 5 Use Case Function (UCF) details 5.1 General Figure 3 — Description of EN 50631-3 5.2 Mapping to SPINE 5.2.1 Concepts 5.2.1.1 General rules and information 5.2.1.1.1 Underlying technology documents |
15 | 5.2.1.1.2 Use Case discovery rules 5.2.1.1.2.1 Incentive Table-based Power Consumption Management 5.2.1.1.2.2 Limitation of Power Consumption |
16 | 5.2.1.1.2.3 Monitoring and Control of Smart Grid Ready Conditions 5.2.1.1.2.4 Monitoring of Power Consumption |
17 | 5.2.1.1.2.5 Optimization of Self Consumption by Heat Pump Compressor Flexibility 5.2.1.1.3 Rules for “Information content” tables 5.2.1.1.3.1 General presence indication definitions |
18 | Table 1 — Presence indication description 5.2.1.1.3.2 Cardinality indications on Elements and list items |
19 | Table 2 — Example table for cardinality indications on Elements and list items 5.2.1.1.3.3 Writability and changeability indication |
20 | 5.2.1.1.3.4 “Value” placeholders Introduction |
21 | Uniqueness of placeholders Placeholder expressions with cardinalities 5.2.1.1.3.4.1 References to placeholders and relations |
23 | Table 3 — Content of an example table 5.2.1.1.3.5 Rules for content of “Value” column |
24 | 5.2.1.1.4 “Actor … overview” diagram rules Figure 4 — Actor overview example 5.2.1.1.5 Order of messages within the sequence diagrams |
25 | 5.2.1.1.6 Further information and rules 5.2.1.1.6.1 Frequently used Element rules 5.2.1.1.6.2 Rules regarding the usage of time-related information |
26 | 5.2.1.1.6.3 Applied sign convention 5.2.1.2 Pre-Scenario communication 5.2.1.2.1 General information 5.2.1.2.2 Detailed discovery |
27 | Figure 5 — Pre-Scenario communication – Detailed discovery sequence diagram |
28 | 5.2.1.2.3 Binding Figure 6 — Pre-Scenario communication – Binding sequence diagram 5.2.1.2.4 Subscription |
29 | Figure 7 — Pre-Scenario communication – Subscription sequence diagram 5.2.1.2.5 Dynamic behaviour 5.2.2 UCF_AC_Measurement 5.2.2.1 Generic Sequence Diagram |
30 | Figure 8 — Generic Sequence Diagram for UCF_AC_Measurement 5.2.2.2 SPINE Mapping 5.2.2.2.1 Request Measurement 5.2.2.2.1.1 General |
31 | Figure 9 — UCF_AC_Measurement: Request Measurement/Measurement communication sequence diagram |
32 | 5.2.2.2.1.2 measurementDescriptionListData read Table 4 — Content of measurementDescriptionListData read at Actor CCM (for “Monitoring of Power Consumption”) 5.2.2.2.1.3 measurementConstraintListData read Table 5 — Content of measurementConstraintListData read at Actor CCM 5.2.2.2.1.4 measurementListData read Table 6 — Content of measurementListData read at Actor CCM |
33 | 5.2.2.2.2 Measurement 5.2.2.2.2.1 For Power measurementDescriptionListData reply Table 7 — Content of measurementDescriptionListData reply or notify at Actor Device – Power, non-phase specific (for “Monitoring of Power Consumption”) Table 8 — Content of measurementDescriptionListData reply or notify at Actor Device – Power, phase-specific (for “Monitoring of Power Consumption”) measurementConstraintsListData reply |
34 | Table 9 — Content of measurementConstraintsListData reply or notify at Actor Device – Power, non-phase specific (for “Monitoring of Power Consumption”) |
35 | Table 10 — Content of measurementConstraintsListData reply or notify at Actor Device – Power, phase-specific (for “Monitoring of Power Consumption”) measurementListData reply Table 11 — Content of measurementListData reply or notify at Actor Device– Power, non-phase specific (for “Monitoring of Power Consumption”) |
36 | Table 12 — Content of measurementListData reply or notify at Actor Device – Power, phase-specific (for “Monitoring of Power Consumption”) |
37 | 5.2.2.2.2.2 For Energy measurementDescriptionListData reply Table 13 — Content of measurementDescriptionListData reply or notify at Actor Device – Energy consumed (for “Monitoring of Power Consumption”) measurementConstraintsListData reply Table 14 — Content of measurementConstraintsListData reply or notify at Actor Device – Energy consumed (for “Monitoring of Power Consumption”) |
38 | measurementListData reply Table 15 — Content of measurementListData reply or notify at Actor Device – Energy consumed (for “Monitoring of Power Consumption”) |
39 | 5.2.2.2.2.3 For Current measurementDescriptionListData reply Table 16 — Content of measurementDescriptionListData reply or notify at Actor Device – Current (for “Monitoring of Power Consumption”) measurementConstraintsListData reply Table 17 — Content of measurementConstraintsListData reply or notify at Actor Device – Current (for “Monitoring of Power Consumption”) |
40 | measurementListData reply Table 18 — Content of measurementListData reply or notify at Actor Device – Current (for “Monitoring of Power Consumption”) 5.2.2.2.2.4 For Voltage measurementDescriptionListData reply |
41 | Table 19 — Content of measurementDescriptionListData reply or notify at Actor Device – Voltage (for “Monitoring of Power Consumption”) measurementConstraintsListData reply Table 20 — Content of measurementConstraintsListData reply or notify at Actor Device – Voltage (for “Monitoring of Power Consumption”) |
42 | measurementListData reply Table 21 — Content of measurementListData reply or notify at Actor Device – Voltage (for “Monitoring of Power Consumption”) 5.2.2.2.2.5 For Frequency measurementDescriptionListData reply |
43 | Table 22 — Content of measurementDescriptionListData reply or notify at Actor Device – Frequency (for “Monitoring of Power Consumption”) measurementConstraintsListData reply Table 23 — Content of measurementConstraintsListData reply or notify at Actor Device – Frequency (for “Monitoring of Power Consumption”) measurementListData reply |
44 | Table 24 — Content of measurementListData reply or notify at Actor Device – Frequency (for “Monitoring of Power Consumption”) 5.2.2.2.3 Request Electrical Connection Data 5.2.2.2.3.1 General |
45 | Figure 10 — UCF_AC_Measurement: Request Electrical Connection Data/Electrical Connection Data communication sequence diagram 5.2.2.2.3.2 electricalConnectionParameterDescriptionListData read Table 25 — Content of electricalConnectionParameterListData read at Actor CCM 5.2.2.2.3.3 electricalConnectionDescriptionListData read Table 26 — Content of electricalConnectionDescriptionListData read at Actor CCM |
46 | 5.2.2.2.4 Electrical Connection Data 5.2.2.2.4.1 General 5.2.2.2.4.2 for Power, Energy, Voltage, Current, Frequency electricalConnectionDescriptionListData reply (for Power, Energy, Voltage, Current, Frequency) Table 27 — Content of electricalConnectionDescriptionListData reply or notify at Actor Device (for “Monitoring of Power Consumption”) 5.2.2.2.4.3 For Power electricalConnectionParameterDescriptionListData reply Table 28 — Content of electricalConnectionParameterDescriptionListData reply or notify at Actor Device – Power, non-phase specific |
47 | Table 29 — Content of electricalConnectionParameterDescriptionListData reply or notify at Actor Device – Power, phase-specific |
48 | 5.2.2.2.4.4 For Energy electricalConnectionParameterDescriptionListData reply Table 30 — Content of electricalConnectionParameterDescriptionListData reply or notify at Actor Device – Energy consumed 5.2.2.2.4.5 For Current electricalConnectionParameterDescriptionListData reply Table 31 — Content of electricalConnectionParameterDescriptionListData reply or notify at Actor Device – Current |
49 | 5.2.2.2.4.6 For Voltage electricalConnectionParameterDescriptionListData reply Table 32 — Content of electricalConnectionParameterDescriptionListData reply or notify at Actor Device – Voltage |
50 | 5.2.2.2.4.7 For Frequency electricalConnectionParameterDescriptionListData reply Table 33 — Content of electricalConnectionParameterDescriptionListData reply or notify at Actor Device – Frequency 5.2.2.2.5 Pre-Scenario communication for Use Case “Monitoring of Power Consumption” (all scenarios) |
51 | 5.2.2.2.6 Actors 5.2.2.2.6.1 CCM Table 34 — Actor naming for “CCM” Figure 11 — Actor “Monitoring Appliance” overview 5.2.2.2.6.2 Device Table 35 — Actor naming for “Device” |
52 | Figure 12 — Actor “Monitored Unit ” overview List of permitted entityTypes for Actor Monitored Unit 5.2.2.3 Additional information 5.2.3 UCF_Characteristics 5.2.3.1 Generic Sequence Diagram |
53 | Figure 13 — Generic Sequence Diagram for UCF_Characteristics 5.2.3.2 SPINE Mapping 5.2.3.2.1 Request Characteristics 5.2.3.2.1.1 General Figure 14 — UCF_Characteristics: Request Characteristics/Characteristics communication sequence diagram 5.2.3.2.1.2 electricalConnectionCharacteristicListData read Table 36 — Content of electricalConnectionCharacteristicListData read at Actor CCM |
54 | 5.2.3.2.2 Characteristics 5.2.3.2.2.1 General 5.2.3.2.2.2 electricalConnectionCharacteristicListData reply Table 37 — Content of electricalConnectionCharacteristicListData reply or notify at Actor Device |
55 | 5.2.3.2.3 Pre-Scenario Communication for Use Case “Limitation of Power Consumption”, Scenario 4 5.2.3.2.4 Actors 5.2.3.2.4.1 CCM Table 38 — Actor naming for “CCM” |
56 | Figure 15 — Actor “CCM” overview 5.2.3.2.4.2 Device Table 39 — Actor naming for “Device” Figure 16 — Actor “Device” overview List of permitted entityTypes for Actor Device |
57 | 5.2.3.3 Additional Information 5.2.4 UCF_Configure_Current_Power_Sequence 5.2.4.1 Generic Sequence Diagram Figure 17 — Generic message sequence of UCF_Configure_Current_Power_Sequence |
58 | 5.2.4.2 SPINE Mapping 5.2.4.2.1 Pause/Resume/Stop Current Power Sequence 5.2.4.2.1.1 General Figure 18 — SPINE message sequence for Pause/Resume/Stop Current Interaction 5.2.4.2.1.2 smartEnergyManagementPs write Table 40 — smartEnergyManagementPsData write for Use Case “Optimization of Self-Consumption by Heat Pump Flexibility” at Actor CCM |
59 | 5.2.4.2.2 Pre-Scenario communication for Use Case “Optimization of Self-Consumption by Heat Pump Flexibility” 5.2.4.2.3 Actors 5.2.4.3 Additional Information 5.2.5 UCF_Consumption_Curve 5.2.5.1 Generic Sequence Diagram |
60 | Figure 19 — Messaging sequence for UCF_Consumption_Curve 5.2.5.2 SPINE Mapping 5.2.5.2.1 Request Consumption Curve 5.2.5.2.1.1 General Figure 20 — SPINE Sequence Diagram for Request Consumption Curve and Consumption Curve |
61 | 5.2.5.2.1.2 timeSeriesDescriptionListData read Table 41 — Information content for timeSeriesDescriptionListData read at Actor CCM (Committed Power Plan) Table 42 — Information content for timeSeriesDescriptionListData read at Actor CCM (Preliminary Power Plan) 5.2.5.2.1.3 timeSeriesListData read Table 43 — Information content for timeSeriesListData read at Actor CCM (Committed Power Plan) Table 44 — Information content for timeSeriesListData read at Actor CCM (Preliminary Power Plan) 5.2.5.2.2 Consumption Curve 5.2.5.2.2.1 General |
62 | 5.2.5.2.2.2 timeSeriesDescriptionListData reply Table 45 — Information content for timeSeriesDescriptionListData reply at Actor Device (Committed Power Plan) Table 46 — Information content for timeSeriesDescriptionListData reply at Actor Device (Preliminary Power Plan) |
63 | 5.2.5.2.2.3 timeSeriesListData reply Table 47 — Information content for timeSeriesListData reply at Actor Device (Committed Power Plan) |
65 | Table 48 — Information content for timeSeriesListData reply at Actor Device (Preliminary Power Plan) |
67 | 5.2.5.2.3 Pre-Scenario Communication for Use Case “Incentive Table-based Power Consumption Management”, Scenarios 2, 3 and 5 5.2.5.2.4 Actors 5.2.5.2.4.1 Device |
68 | Table 49 — Resource Names for UCF_Incentive_Table Actor “Device” Figure 21 — Actor “Device” overview List of permitted entityTypes for Actor Energy Consumer 5.2.5.2.4.2 CCM Table 50 — Resource Names for UCF_Incentive_Table Actor “CCM” |
69 | Figure 22 — Actor “Device” overview 5.2.5.3 Additional Information 5.2.5.3.1 Committed Power Plan 5.2.5.3.1.1 Recommendations on “timeSeriesId” 5.2.5.3.1.2 Recommendations on “timeSeriesSlotId” 5.2.5.3.1.3 Recommendations on “partial operations” on slots |
70 | 5.2.5.3.2 Preliminary Power Plan 5.2.5.3.2.1 Recommendations on “timeSeriesId” 5.2.5.3.2.2 Recommendations on “partial operations” on slots |
71 | 5.2.6 UCF_Device_Configuration 5.2.6.1 Generic Sequence Diagram |
72 | Figure 23 — Generic Sequence Diagram for UCF_Device_Configuration 5.2.6.2 SPINE Mapping 5.2.6.2.1 Request Device Configuration Data 5.2.6.2.1.1 General Figure 24 — UCF_Device Configuration: Request Device Configuration/Device Configuration Data communication sequence diagram |
73 | 5.2.6.2.1.2 deviceConfigurationKeyValueDescriptionListData read Table 51 — Content of deviceConfigurationKeyValueDescriptionListData read at Actor CCM 5.2.6.2.1.3 deviceConfigurationKeyValueListData read Table 52 — Content of deviceConfigurationKeyValueListData read at Actor CCM 5.2.6.2.2 Device Configuration Data 5.2.6.2.2.1 General 5.2.6.2.2.2 deviceConfigurationKeyValueDescriptionListData reply |
74 | Table 53 — Content of deviceConfigurationKeyValueDescriptionListData reply or notify at Actor Device – failsafeConsumptionActivePowerLimit Table 54 — Content of deviceConfigurationKeyValueDescriptionListData reply or notify at Actor Device – failsafeDurationMinimum |
75 | Table 55 — Content of deviceConfigurationKeyValueDescriptionListData reply or notify at Actor Device – incentivesSimulationCyclesMax Table 56 — Content of deviceConfigurationKeyValueDescriptionListData reply or notify at Actor Device – incentivesSimulationConcurrent |
76 | Table 57 — Content of deviceConfigurationKeyValueDescriptionListData reply or notify at Actor Device – incentivesTimeoutIncentiveRequest Table 58 — Content of deviceConfigurationKeyValueDescriptionListData reply or notify at Actor Device – incentivesWaitIncentiveWriteable |
77 | 5.2.6.2.2.3 deviceConfigurationKeyValueListData reply Table 59 — Content of deviceConfigurationKeyValueListData reply or notify at Actor Device Table 60 — Content of deviceConfigurationKeyValueListData reply or notify at Actor Device |
78 | Table 61 — Content of deviceConfigurationKeyValueListData reply or notify at Actor Device Table 62 — Content of deviceConfigurationKeyValueListData reply or notify at Actor Device |
79 | Table 63 — Content of deviceConfigurationKeyValueListData reply or notify at Actor Device Figure 25 — UCF_Device Configuration: Notify Device Configuration Data communication sequence diagram 5.2.6.2.3 Write Device Configuration Data 5.2.6.2.3.1 General |
80 | 5.2.6.2.3.2 deviceConfigurationKeyValueListData write Table 64 — Content of deviceConfigurationKeyValueListData write at Actor CCM Table 65 — Content of deviceConfigurationKeyValueListData write at Actor CCM |
81 | Figure 26 — UCF_Device Configuration: Write Device Configuration communication sequence diagram 5.2.6.2.4 Pre-Scenario communication for Use Case „Limitation of Power Consumption” (Scenario 2) 5.2.6.2.5 Pre-Scenario communication for Use Case „Incentive-table based Power consumption Management” (Scenario 1) |
82 | 5.2.6.2.6 Actors 5.2.6.2.6.1 Device Table 66 — Actor naming for “Device” Figure 27 — Actor “Controllable System” overview List of permitted entityTypes for Actor Device |
83 | 5.2.6.2.6.2 CCM Table 67 — Actor naming for “CCM” Figure 28 — Actor “Energy Guard” overview 5.2.6.3 Additional information 5.2.7 UCF_Device_Connected 5.2.7.1 Generic Sequence Diagram |
84 | Figure 29 — Communication sequence diagram for UCF_Device_Connected 5.2.7.2 SPINE Mapping 5.2.7.3 Additional Information 5.2.8 UCF_Heartbeat 5.2.8.1 Generic Sequence Diagram Figure 30 — Generic message sequence for UCF_Heartbeat |
85 | 5.2.8.2 SPINE Mapping 5.2.8.2.1 Request Heartbeat 5.2.8.2.1.1 General Figure 31 — UCF_Heartbeat communication sequence diagram 5.2.8.2.1.2 deviceDiagnosisHeartbeatData read Table 68 — Content of deviceDiagnosisHEartbeatData read at Actor Device or CCM 5.2.8.2.2 Heartbeat 5.2.8.2.2.1 General |
86 | 5.2.8.2.2.2 deviceDiagnosisHeartbeatData reply Table 69 — Content of deviceDiagnosisHeartbeatData reply or notify at Actor Device or CCM 5.2.8.2.3 Pre-Scenario Communication for Use Case “Limitation of Power Consumption” |
87 | 5.2.8.2.4 Actors 5.2.8.2.4.1 Device Table 70 — Actor naming for “Device” Figure 32 — Actor “Device” overview List of permitted entityTypes for Actor Device 5.2.8.2.4.2 CCM |
88 | Table 71 — Actor naming for “CCM” Figure 33 — Actor “CCM” overview 5.2.8.3 Additional Information 5.2.9 UCF_Incentive_Table 5.2.9.1 Generic Sequence Diagram |
89 | Figure 34 — Sequence diagram for UCF_Incentive_Table 5.2.9.2 SPINE Mapping 5.2.9.2.1 Read Incentive Table 5.2.9.2.1.1 General |
90 | Figure 35 — SPINE Sequence Diagram for Read Incentive Table and Incentive Table |
91 | 5.2.9.2.1.2 incentiveTableDescriptionData read Table 72 — Information content for incentiveTableDescriptionData read at Actor CCM (Committed Incentive Table) Table 73 — Information content for incentiveTableDescriptionData read at Actor CCM (Preliminary Incentive Table) 5.2.9.2.1.3 incentiveTableConstraintsData read Table 74 — Information content for incentiveTableConstraintsData read at Actor CCM 5.2.9.2.1.4 incentiveTableData read Table 75 — Information content for incentiveTableData read at Actor CCM |
92 | 5.2.9.2.2 Incentive Table 5.2.9.2.2.1 General 5.2.9.2.2.2 incentiveTableDescriptionData reply Table 76 — Information content for incentiveTableDescriptionData reply at Actor Device (Committed Incentive Table) |
95 | Table 77 — Information content for incentiveTableDescriptionData reply at Actor Device (Preliminary Incentive Table) |
98 | 5.2.9.2.2.3 incentiveTableConstraintsData reply Table 78 — Information content for incentiveTableConstraintsData reply at Actor Device (Committed Incentive Table) Table 79 — Information content for incentiveTableConstraintsData reply at Actor Device (Preliminary Incentive Table) |
99 | 5.2.9.2.2.4 incentiveTableData reply Table 80 — Information content for incentiveTableData reply at Actor Device (Committed Incentive Table) |
102 | Table 81 — Information content for incentiveTableData reply at Actor Device (Preliminary Incentive Table) |
103 | 5.2.9.2.3 Write Incentive Table |
104 | Figure 36 — SPINE Sequence Diagram for Write Incentive Table 5.2.9.2.3.1 incentiveTableDescriptionData write Table 82 — Information content for incentiveTableDescriptionData write at Actor Device (Committed Incentive Table) |
106 | Table 83 — Information content for incentiveTableDescriptionData reply at Actor Device (Preliminary Incentive Table) |
109 | 5.2.9.2.3.2 incentiveTableData write Table 84 — Information content for incentiveTableData write at Actor Device (Committed Incentive Table) |
111 | Table 85 — Information content for incentiveTableData reply at Actor Device (Preliminary Incentive Table) |
113 | 5.2.9.2.4 Pre-Scenario Communication for Use Case “Incentive Table-based Power Consumption Management”, Scenarios 2, 3 and 4 5.2.9.2.5 Actors 5.2.9.2.5.1 Device Table 86 — Resource Names for UCF_Incentive_Table Actor “Device” |
114 | Figure 37 — Actor “Device” overview List of permitted entityTypes for Actor Device 5.2.9.2.5.2 CCM Table 87 — Resource Names for UCF_Incentive_Table Actor “CCM” |
115 | Figure 38 — Actor “Device” overview 5.2.9.3 Additional information 5.2.9.3.1 Committed Incentive Table 5.2.9.3.1.1 Recommendations on “tariffId” 5.2.9.3.1.2 Recommendations on “timeSlotId” 5.2.9.3.1.3 Recommendations on “partial operations” on slots |
116 | 5.2.9.3.1.4 Recommendations on “partial operations” on “incentiveTableDescriptionData” |
117 | 5.2.9.3.2 Preliminary Incentive Table 5.2.9.3.2.1 Recommendations on “tariffId” |
118 | 5.2.9.3.2.2 Recommendations on “partial operations” on slots 5.2.9.3.2.3 Recommendations on “partial operations” on “incentiveTableDescriptionData” |
119 | 5.2.10 UCF_Overrun 5.2.10.1 Generic Sequence Diagram Figure 39 — Sequence diagram for UCF_Overrun 5.2.10.2 SPINE Mapping 5.2.10.2.1 Request Overrun Settings 5.2.10.2.1.1 General |
120 | Figure 40 — SPINE Sequence Diagram for Request Overrun Settings and Overrun Settings 5.2.10.2.1.2 hvacSystemFunctionDescriptionListData read 5.2.10.2.1.3 hvacSystemFunctionListData read 5.2.10.2.1.4 hvacOverrunDescriptionListData read Table 88 — Information content for hvacOverrunDescriptionListData read for Use Case “Monitoring and Control of Smart Grid Ready Conditions” at Actor CCM |
121 | 5.2.10.2.1.5 hvacOverrunListData read Table 89 — Information content for hvacSystemFunctionDescriptionListData read for Use Case “Monitoring and Control of Smart Grid Ready Conditions” at Actor CCM 5.2.10.2.2 Overrun Settings 5.2.10.2.2.1 General 5.2.10.2.2.2 hvacSystemFunctionDescriptionListData reply 5.2.10.2.2.3 hvacSystemFunctionListData reply 5.2.10.2.2.4 hvacOverrunDescriptionListData reply Table 90 — Information content for hvacSystemFunctionDescriptionListData reply at Actor Device for Use Case “Monitoring and Control of Smart Grid Ready Conditions” |
122 | 5.2.10.2.2.5 hvacOverrunListData reply Table 91 — Information content for hvacOverrunListData reply at Actor Device for Use Case “Monitoring and Control of Smart Grid Ready Conditions” 5.2.10.2.3 Write Overrun 5.2.10.2.3.1 General |
123 | Figure 41 — SPINE Sequence Diagram for Write Overrun and Overrun 5.2.10.2.3.2 hvacOverrunListData write Table 92 — Information content for hvacOverrunListData reply at Actor Device for Use Case “Monitoring and Control of Smart Grid Ready Conditions” |
124 | 5.2.10.2.4 Overrun 5.2.10.2.5 Pre-Scenario communication for Use Case “Monitoring and Control of Smart Grid Ready Conditions” 5.2.10.2.6 Actors 5.2.10.2.6.1 CCM Table 93 — Resource Names for UCF_Measurement Actor “CCM” |
125 | Figure 42 — Actor “CCM” overview 5.2.10.2.6.2 Device Table 94 — Resource Names for UCF_Measurement Actor “Device” |
126 | Figure 43 — Actor “Heat Pump” overview 5.2.10.3 Additional Information 5.2.11 UCF_Plan_With_Power_Sequences 5.2.11.1 Generic Sequence Diagram Figure 44 — Generic message sequence of UCF_Plan_With_Power_Sequences |
127 | 5.2.11.2 SPINE Mapping 5.2.11.2.1 Request Plan 5.2.11.2.1.1 General Figure 45 — Message sequence diagram for Request Plan and Power Plan 5.2.11.2.1.2 smartEnergyManagementPsData read Table 95 — Information content for smartEnergyManagementPsData read at Actor CCM 5.2.11.2.2 Power Plan 5.2.11.2.2.1 General 5.2.11.2.2.2 smartEnergyManagementPsData reply Table 96 — Information content for smartEnergyManagementPsData reply for Use Case “Optimization of Self-Consumption by Heat Pump Flexibility” at Actor Device |
131 | 5.2.11.2.3 Pre-scenario communication for Use Case “Optimization of Self-Consumption by Heat Pump Flexibility” 5.2.11.2.4 Actors 5.2.11.2.4.1 CCM |
132 | Figure 46 — Actor “CCM” overview 5.2.11.2.4.2 Device Table 97 — Resource Names for UCF_Measurement Actor “Device” |
133 | Figure 47 — Actor “Device” overview 5.2.11.3 Additional Information 5.2.11.3.1 State Transitions |
134 | Figure 48 — State transitions of a power sequence. See Table 98 for descriptions. Table 98 — Description of state transitions of a power sequence. For transition references, see Figure 47 |
135 | 5.2.11.3.2 Additional information for Use Case “Optimization of Self Consumption by Heat Pump Compressor Flexibility” 5.2.12 UCF_Power_Limit 5.2.12.1 Generic Sequence Diagram Figure 49 — Generic Message sequence of UCF_Power_Limit 5.2.12.2 SPINE Mapping 5.2.12.2.1 Read Active Power Limit 5.2.12.2.1.1 General |
136 | Figure 50 — UCF_Power_Limit: Read Active Power Limit/Current Active Power Limit communication sequence diagram 5.2.12.2.1.2 loadControlLimitDescriptionListData read Table 99 — Content of loadControlLimitDescriptionListData read at Actor CCM 5.2.12.2.1.3 loadControlLimitListData read Table 100 — Content of loadControlLimitListData read at Actor CCM 5.2.12.2.2 Current Active Power Limit |
137 | 5.2.12.2.2.1 loadControlLimitDescriptionListData reply Table 101 — Content of loadControlLimitDescriptionListData reply or notify at Actor Device |
138 | 5.2.12.2.2.2 loadControlLimitListData reply Table 102 — Content of loadControlLimitListData reply or notify at Actor Device Figure 51 — UCF_Power_Limit: Notify Current Active Power Limit communication sequence diagram |
139 | 5.2.12.2.3 Send Active Power Limit Table 103 — Content of loadControlLimitListData write at Actor CCM Figure 52 — UCF_Power_Limit: Send Active Power Limit communication sequence diagram 5.2.12.2.4 ACK/NACK 5.2.12.2.5 Pre-Scenario Communication |
140 | 5.2.12.2.6 Actors 5.2.12.2.6.1 CCM General Figure 53 — Actor “Energy Guard” overview List of permitted entityTypes for Actor Energy Guard 5.2.12.2.6.2 Device |
141 | Figure 54 — Actor “Controllable System” overview List of permitted entityTypes for Actor Controllable System 5.2.12.3 Additional Information 5.2.13 UCF_Report_Status_Of_Power_Sequence 5.2.13.1 Generic Sequence Diagram |
142 | Figure 55 — Generic Sequence Diagram for UCF_Report_Status_Of_Power_Sequence 5.2.13.2 SPINE Mapping 5.2.13.2.1 Request Status 5.2.13.2.1.1 General Figure 56 — Message sequence diagram for Request Plan and Power Plan 5.2.13.2.1.2 smartEnergyManagementPsData read Table 104 — Information content for smartEnergyManagementPsData read at Actor CCM 5.2.13.2.2 Status of Power Sequence |
143 | Table 105 — Information content for smartEnergyManagementPsData reply for Use Case “Optimization of Self-Consumption by Heat Pump Flexibility” at Actor Device |
146 | 5.2.13.2.3 Pre-scenario communication for Use Case “Optimization of Self-Consumption by Heat Pump Flexibility” 5.2.13.2.4 Actors 5.2.13.3 Additional Information |
147 | 5.2.14 UCF_Select_Power_Sequence 5.2.14.1 Generic Sequence Diagram Figure 57 — Generic message sequence of UCF_Select_Power_Sequence 5.2.14.2 SPINE Mapping 5.2.14.2.1 Select Interaction 5.2.14.2.1.1 General |
148 | Figure 58 — SPINE message sequence for Select interaction 5.2.14.2.1.2 smartEnergyManagementPsData notify 5.2.14.2.1.3 smartEnergyManagementPsData write Table 106 — Information content for smartEnergyManagementPsData write at Actor CCM for Use Case “Optimization of Self-Consumption by Heat Pump Flexibility” |
149 | 5.2.14.2.2 Pre-Scenario communication for Use Case “Optimization of Self-Consumption by Heat Pump Flexibility” 5.2.14.2.3 Actors 5.2.14.3 Additional Information 5.2.15 UCF_Shift_Preferred_Power_Sequence 5.2.15.1 Generic Sequence Diagram Figure 59 — Generic message sequence of UCF_Shift_Preferred_Power_Sequence |
150 | 5.2.15.2 SPINE Mapping 5.2.15.2.1 Shift Preferred Power Sequence 5.2.15.2.1.1 General Figure 60 — SPINE message sequence for Shift interaction 5.2.15.2.1.2 smartEnergyManagementPsData write Table 107 — Information content for smartEnergyManagementPsData write at Actor CCM for Use Case “Optimization of Self-Consumption by Heat Pump Flexibility” |
151 | 5.2.15.2.2 Pre-Scenario communication for Use Case “Optimization of Self-Consumption by Heat Pump Flexibility” 5.2.15.2.3 Actors 5.2.15.3 Additional information |
152 | 5.2.16 UCF_System_Function 5.2.16.1 Generic Sequence Diagram Figure 61 — Sequence diagram for UCF_System_Function 5.2.16.2 SPINE Mapping 5.2.16.2.1 Request System Function 5.2.16.2.1.1 General |
153 | Figure 62 — SPINE Sequence Diagram for Request Overrun Settings and Overrun Settings 5.2.16.2.1.2 hvacSystemFunctionDescriptionListData read Table 108 — Information content for hvacSystemFunctionDescriptionListData read at Actor CCM 5.2.16.2.1.3 hvacOperationModeDescriptionListData read 5.2.16.2.1.4 hvacSystemFunctionOperationModeRelationListData read 5.2.16.2.1.5 hvacSystemFunctionListData read |
154 | 5.2.16.2.2 System Function 5.2.16.2.2.1 General 5.2.16.2.2.2 hvacSystemFunctionDescriptionListData reply Table 109 — Information content for hvacSystemFunctionDescriptionListData reply at Actor Device 5.2.16.2.2.3 hvacSystemFunctionOperationModeRelationListData reply 5.2.16.2.2.4 hvacOperationModeDescriptionListData reply 5.2.16.2.2.5 hvacSystemFunctionListData reply 5.2.16.2.3 Change System Function 5.2.16.2.3.1 General |
155 | Figure 63 — SPINE Sequence Diagram for Change System Function and System Function 5.2.16.2.3.2 hvacSystemFunctionListData write 5.2.16.2.4 Pre-Scenario communication 5.2.16.2.5 Actors 5.2.16.2.5.1 CCM 5.2.16.2.5.2 General Table 110 — Resource Names for UCF_System_Function Actor “CCM” |
156 | Figure 64 — Actor “Configuration Appliance” overview 5.2.16.2.5.3 Device Table 111 — Resource Names for UCF_System_Funtion Actor “Device” Figure 65 — Actor “Heat Pump” overview |
157 | 5.2.16.3 Additional information 5.3 Mapping to SPINE-IoT 5.3.1 Concepts 5.3.1.1 General rules and information 5.3.1.1.1 Underlying technology documents 5.3.1.1.2 Use Case discovery rules 5.3.1.1.2.1 Flexible Start for White Goods 5.3.1.1.3 Rules for “Information content” tables 5.3.1.1.3.1 General presence indication definitions 5.3.1.1.3.2 Cardinality indications on Elements and list items |
158 | 5.3.1.1.3.3 Writability and changeability indication 5.3.1.1.3.4 “Value” placeholders 5.3.1.1.3.5 Rules for content of “Value” column 5.3.1.1.4 “Actor … overview” diagram rules 5.3.1.1.5 Order of messages within the sequence diagrams 5.3.1.2 Pre-Scenario communication 5.3.1.2.1 General information 5.3.1.2.2 Detailed Discovery 5.3.1.2.3 Binding 5.3.1.2.4 Subscription |
159 | 5.3.1.2.5 Features 5.3.1.2.6 Use Cases 5.3.2 UCF_Configure_Current_Power_Sequence 5.3.2.1 Generic Sequence Diagram Figure 66 — Generic message sequence of UCF_Configure_Current_Power_Sequence |
160 | Figure 67 — Generic message sequence of UCF_Configure_Current_Power_Sequence 5.3.2.2 SPINE-IoT Mapping 5.3.2.2.1 Configure Current Power Sequence (Pause/Resume/Stop) 5.3.2.2.1.1 Request via /usecaseInterfaces 5.3.2.2.1.2 configureSequence POST Table 112 — Information content for configureSequence for Use Case “Flexible Start for White Goods” at Actor Device |
161 | 5.3.2.2.2 Pre-Scenario communication for Use Case “Flexible Start for White Goods” 5.3.2.2.3 Actors 5.3.2.3 Additional Information 5.3.3 UCF_Device_Connected 5.3.3.1 Generic Sequence Diagram Figure 68 — Communication sequence diagram for UCF_Device_Connected 5.3.3.2 SPINE-IoT Mapping 5.3.3.3 Additional Information 5.3.4 UCF_Plan_With_Power_Sequences 5.3.4.1 Generic Sequence Diagram |
162 | Figure 69 — Generic message sequence of UCF_Plan_With_Power_Sequences 5.3.4.2 SPINE-IoT Mapping 5.3.4.2.1 Request Plan 5.3.4.2.1.1 Request via /usecaseInterfaces Figure 70 — Message sequence diagram for Request Plan and Response Power Plan 5.3.4.2.2 Power Plan 5.3.4.2.2.1 General |
163 | 5.3.4.2.2.2 Power Sequence Node Table 113 — Information content for Feature object type powerSequenceNode for Use Case “Flexible Start for White Goods” at Actor Device 5.3.4.2.2.3 Power Sequence Alternatives Relation Table 114 — Information content for Feature object type powerSequenceAlternativesRelation for Use Case “Flexible Start for White Goods” at Actor Device |
164 | 5.3.4.2.2.4 Power Sequence Table 115 — Information content for Feature object type powerSequence for Use Case “Flexible Start for White Goods” at Actor Device |
165 | Table 116 — Details for “powerSequence” references 5.3.4.2.2.5 Power Time Slot |
166 | Table 117 — Information content for Feature object type powerTimeSlot for Use Case “Flexible Start for White Goods” at Actor Device 5.3.4.2.3 Pre-scenario communication for Use Case “Flexible Start for White Goods” |
167 | 5.3.4.2.4 Actors 5.3.4.3 Additional Information 5.3.5 UCF_Select_Power_Sequence 5.3.5.1 Generic Sequence Diagram Figure 71 — Generic message sequence of UCF_Select_Power_Sequence 5.3.5.2 SPINE-IoT Mapping 5.3.5.3 Additional Information 5.3.6 UCF_Shift_Preferred_Power_Sequence 5.3.6.1 Generic Sequence Diagram |
168 | Figure 72 — Generic message sequence of UCF_Shift_Preferred_Power_Sequence 5.3.6.2 SPINE-IoT Mapping 5.3.6.2.1 Shift Preferred Power Sequence 5.3.6.2.1.1 Request via /usecaseInterfaces Figure 73 — Message sequence diagram for Shift Power Sequence in SPINE-IoT 5.3.6.2.2 shiftSelectSequence POST |
169 | Table 118 — Information content for shiftSelectSequence for Use Case “Flexible Start for White Goods” at Actor Device 5.3.6.2.3 Pre-scenario communication for Use Case “Flexible Start for White Goods” 5.3.6.2.4 Actors 5.3.6.3 Additional information 5.3.7 YAML models for SPINE-IoT 5.3.7.1 General 5.3.7.2 YAML SPINE-IoT Power Sequences |
177 | 5.3.7.3 YAML SPINE-IoT Device Management |
197 | 5.3.7.4 YAML SPINE-IoT Use Case Interface Flexible Start For White Goods |
201 | Bibliography |