FL Residential 07 2007
$55.93
Florida Building Code – Residential
Published By | Publication Date | Number of Pages |
FL | 2007 | 884 |
This is a fully integrated code based on the 2006 International Residential Code.
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | 2007 FLORIDA BUILDING CODE: RESIDENTIAL |
2 | COPYRIGHT |
3 | PREFACE |
5 | TABLE OF CONTENTS |
13 | PART I — ADMINISTRATIVE CHAPTER 1 ADMINISTRATION SECTION R101 TITLE, SCOPE AND PURPOSE SECTION R102 APPLICABILITY SECTION R103 DEPARTMENT OF BUILDING SAFETY SECTION R104 DUTIES AND POWERS OF THE BUILDING OFFICIAL SECTION R105 PERMITS SECTION R106 CONSTRUCTION DOCUMENTS SECTION R107 TEMPORARY STRUCTURES AND USES SECTION R108 FEES SECTION R109 INSPECTIONS SECTION R110 CERTIFICATE OF OCCUPANCY SECTION R111 SERVICE UTILITIES SECTION R112 BOARD OF APPEALS SECTION R113 VIOLATIONS SECTION R114 STOP WORK ORDER |
15 | PART II DEFINITIONS CHAPTER 2 DEFINITIONS SECTION R201 GENERAL SECTION R202 DEFINITIONS |
29 | PART III — BUILDING PLANNING AND CONSTRUCTION CHAPTER 3 BUILDING PLANNING SECTION R301 DESIGN CRITERIA TABLE R301.2(1) CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA |
30 | TABLE R301.2(2) COMPONENT AND CLADDING LOADS FOR A BUILDING WITH A MEAN ROOF HEIGHT OF 30 FEET LOCATED IN EXPOSURE B (psf) |
31 | TABLE R301.2(3) HEIGHT AND EXPOSURE ADJUSTMENT COEFFICIENTS FOR TABLE R301.2(2) TABLE R301.2(4) GARAGE DOOR LOADS FOR A BUILDING WITH A MEAN ROOF HEIGHT OF 30 FEET LOCATED IN EXPOSURE B |
32 | FIGURE R301.2(1) ISOLINES OF THE 971/2 PERCENT WINTER (DECEMBER, JANUARY AND FEBRUARY) DESIGN TEMPERATURES (°F) |
33 | TABLE R301.2.1.2 WINDBORNE DEBRIS PROTECTION FASTENING SCHEDULE FOR WOOD STRUCTURAL PANELS |
34 | TABLE R301.2.1.3 EQUIVALENT BASIC WIND SPEEDSa |
35 | TABLE R301.5 MINIMUM UNIFORMLY DISTRIBUTED LIVE LOADS (IN POUNDS PER SQUARE FOOT) TABLE R301.6 MINIMUM ROOF LIVE LOADS IN POUNDS-FORCE PER SQUARE FOOT OF HORIZONTAL PROJECTION |
36 | FIGURE R301.2(3) WEATHERING PROBABILITY MAP FOR CONCRETE |
37 | WIND-BORNE DEBRIS REGION |
38 | FIGURE R301.2(6) TERMITE INFESTATION PROBABILITY MAP |
39 | FIGURE R301.2(7) COMPONENT AND CLADDING PRESSURE ZONES TABLE R301.7 ALLOWABLE DEFLECTION OF STRUCTURAL MEMBERSa,b,c |
40 | FIGURE R301.3 COMPONENT AND CLADDING PRESSURE ZONES |
41 | SECTION R302 EXTERIOR WALL LOCATION TABLE R302.1 EXTERIOR WALLS SECTION R303 LIGHT, VENTILATION AND HEATING |
42 | SECTION R304 MINIMUM ROOM AREAS SECTION R305 CEILING HEIGHT SECTION R306 SANITATION |
43 | SECTION R307 TOILET, BATH AND SHOWER SPACES SECTION R308 GLAZING |
44 | FIGURE R307.1 MINIMUM FIXTURE CLEARANCES TABLE R308.3 MINIMUM CATEGORY CLASSIFICATION OF GLAZING |
46 | SECTION R309 GARAGES AND CARPORTS SECTION R310 EMERGENCY ESCAPE AND RESCUE OPENINGS |
47 | SECTION R311 MEANS OF EGRESS |
49 | SECTION R312 GUARDS SECTION R313 SMOKE ALARMS |
50 | SECTION R314 FOAM PLASTIC |
51 | SECTION R315 FLAME SPREAD AND SMOKE DENSITY |
52 | SECTION R316 INSULATION SECTION R317 DWELLING UNIT SEPARATION |
54 | SECTION R318 MOISTURE VAPOR RETARDERS SECTION R319 PROTECTION AGAINST DECAY |
55 | SECTION R320 PROTECTION AGAINST TERMITES |
57 | SECTION R321 SITE ADDRESS SECTION R322 ACCESSIBILITY SECTION R323 RESISTANT CONSTRUCTION SECTION R324 FIRE PROTECTION SECTION R325 AIRPORT NOISE |
59 | CHAPTER 4 FOUNDATIONS SECTION R401GENERAL TABLE R401.4.1 PRESUMPTIVE LOAD–BEARING VALUES OF FOUNDATION MATERIALSa SECTION R402 MATERIALS |
60 | TABLE R401.1 FOUNDATION UPLIFT LIGHT STEEL AND WOOD FRAME BUILDINGS IN EXPOSURE B (plf)5,6 |
61 | TABLE R401.1 (CONTINUED) FOUNDATION UPLIFT LIGHT STEEL AND WOOD FRAME BUILDINGS IN EXPOSURE C (plf)5,6 |
62 | TABLE R402.2 MINIMUM SPECIFIED COMPRESSIVE STRENGTH OF CONCRETE SECTION R403 FOOTINGS TABLE R403.1 MINIMUM WIDTH OF CONCRETE OR MASONRY FOOTINGS (INCHES)a |
63 | FIGURE 403.1(1) CONCRETE AND MASONRY FOUNDATION DETAILS |
64 | FIGURE R403.1(1)—(CONTINUED) |
65 | FIGURE R403.1(1)—(CONTINUED) |
66 | FIGURE R403.1(1)—(CONTINUED) |
67 | FIGURE R403.1(1)—(CONTINUED) |
68 | FIGURE R403.1(1)—(CONTINUED) |
69 | FIGURE R403.1(2) PERMANENT WOOD FOUNDATION BASEMENT WALL SECTION |
70 | FIGURE R403.1(3) PERMANENT WOOD FOUNDATION CRAWL SPACE SECTION |
71 | TABLE R403.1.1 FOUNDATION UPLIFT DESIGN DETAILS FIGURE R403.1.7.1 FOUNDATION CLEARANCE FROM SLOPES |
72 | SECTION R404 FOUNDATION AND RETAINING WALLS |
73 | TABLE R404.1(1) TOP REACTIONS AND PRESCRIPTIVE SUPPORT FOR FOUNDATION WALLSa |
74 | TABLE R404.1(2) MAXIMUM PLATE ANCHOR-BOLT SPACING FOR SUPPORTED FOUNDATION WALLa TABLE R404.1(3) MAXIMUM ASPECT RATIO, L/W FOR UNBALANCED FOUNDATIONS |
75 | TABLE R404.1.1(1) PLAIN MASONRY FOUNDATION WALLS |
76 | TABLE R404.1.1(2) INCH MASONRY FOUNDATION WALLS WITH REINFORCING WHERE d > 5 INCHESa |
77 | TABLE R404.1.1(3) 10-INCH MASONRY FOUNDATION WALLS WITH REINFORCING WHERE d > 6.75 INCHESa |
78 | TABLE R404.1.1(4) 12-INCH MASONRY FOUNDATION WALLS WITH REINFORCING WHERE d > 8.75 INCHESa |
79 | TABLE R404.1.1(5) CONCRETE FOUNDATION WALLSh, i, j, k |
80 | TABLE R404.1.1(5)—(CONTINUED) CONCRETE FOUNDATION WALLSh, I, j, k |
81 | FIGURE R404.1.5(1) FOUNDATION WALL CLAY MASONRY CURTAIN WALL WITH CONCRETE MASONRY PIERS |
82 | TABLE R404.2.3 PLYWOOD GRADE AND THICKNESS FOR WOOD FOUNDATION CONSTRUCTION (30 PCF EQUIVALENT-FLUID WEIGHT SOIL PRESSURE) |
83 | TABLE R404.4(1) 5.5-INCH THICK FLAT ICF FOUNDATION WALLSa, b, c, d |
84 | TABLE R404.4(2) 7.5-INCH-THICK FLAT ICF FOUNDATION WALLSa, b, c, d, e |
85 | TABLE R404.4(3) 9.5-INCH-THICK FLAT ICF FOUNDATION WALLSa, b, c, d, e |
86 | TABLE R404.4(4) WAFFLE GRID ICF FOUNDATION WALLSa, b, c, d, e |
87 | TABLE R404.4(5) SCREEN-GRID ICF FOUNDATION WALLSa, b c, d, e SECTION R405 FOUNDATION DRAINAGE |
88 | TABLE R405.1 PROPERTIES OF SOILS CLASSIFIED ACCORDING TO THE UNIFIED SOIL CLASSIFICATION SYSTEM SECTION R406 FOUNDATION WATERPROOFINGAND DAMPPROOFING |
89 | SECTION R407 COLUMNS SECTION R408 UNDER-FLOOR SPACE |
91 | CHAPTER 5 FLOORS SECTION R501 GENERAL SECTION R502 WOOD FLOOR FRAMING |
93 | FIGURE R502.2 FLOOR CONSTRUCTION |
94 | TABLE R502.2.3(1) FLOOR JOIST SPANS FOR COMMON LUMBER SPECIES (RESIDENTIAL SLEEPING AREAS, LIVE LOAD = 30 psf, L/Δ = 360)a |
95 | TABLE R502.2.3(2) FLOOR JOIST SPANS FOR COMMON LUMBER SPECIES (RESIDENTIAL LIVING AREAS, LIVE LOAD = 40 PSF, L/ = 360)b |
96 | TABLE R502.2.3.3(1) CANTILEVER SPANS FOR FLOOR JOISTS SUPPORTING LIGHT-FRAME EXTERIOR BEARING WALL AND ROOF ONLYa, b, c, f, g, h (FLOOR LIVE LOAD 40 psf, ROOF LIVE LOAD =20 psf) TABLE R502.2.3.3(2) CANTILEVER SPANS FOR FLOOR JOISTS SUPPORTING EXTERIOR BALCONYa, b, e, f |
97 | TABLE R502.2.5 (1) GIRDER SPANSa AND HEADER SPANSa FOR EXTERIOR BEARING WALLS (MAXIMUM SPANS FOR DOUGLAS FIR-LARCH, HEM-FIR, SOUTHERN PINE AND SPRUCE-PINE-FIRB AND REQUIRED NUMBER OF JACK STUDS) |
98 | TABLE R502.2.5(1) (CONTINUED) GIRDER SPANSa AND HEADER SPANSa FOR EXTERIOR BEARING WALLS (MAXIMUM SPANS FOR DOUGLAS FIR-LARCH, HEM-FIR, SOUTHERN PINE AND SPRUCE-PINE-FIRB AND REQUIRED NUMBER OF JACK STUDS) |
99 | TABLE R502.2.5(2) GIRDER SPANSa AND HEADER SPANSa FOR INTERIOR BEARING WALLS (MAXIMUM SPANS FOR DOUGLAS FIR-LARCH, HEM-FIR, SOUTHERN PINE AND SPRUCE-PINE-FIRb AND REQUIRED NUMBER OF JACK STUDS) |
100 | FIGURE R502.2.8 CUTTING, NOTCHING AND DRILLING |
101 | SECTION R503 FLOOR SHEATHING TABLE R503.1 MINIMUM THICKNESS OF LUMBER FLOOR SHEATHING TABLE R503.2.1.1(2) ALLOWABLE SPANS FOR SANDED PLYWOOD COMBINATION SUBFLOOR UNDERLAYMENTa SECTION R504 PRESSURE-PRESERVATIVE-TREATED WOOD FLOORS (ON GROUND) |
102 | TABLE R503.2.1.1(1) ALLOWABLE SPANS AND LOADS FOR WOOD STRUCTURAL PANELS FOR ROOF AND SUBFLOOR SHEATHING AND COMBINATION SUBFLOOR UNDERLAYMENTa, b, c |
103 | SECTION R505 STEEL FLOOR FRAMING |
104 | TABLE R505.2(1) COLD-FORMED STEEL JOIST SIZES TABLE R505.2(2) MINIMUM THICKNESS OF COLD-FORMED STEEL MEMBERS TABLE R505.2.4 SCREW SUBSTITUTION FACTOR |
105 | FIGURE R505.2(3) FLOOR JOIST WEB HOLES |
106 | FIGURE R505.3 STEEL FLOOR CONSTRUCTION |
107 | FIGURE R505.3— (CONTINUED) STEEL FLOOR CONSTRUCTION |
108 | TABLE R505.3.1(1) FLOOR TO FOUNDATION OR BEARING WALL CONNECTION REQUIREMENTS a,b TABLE R505.3.1(2) FLOOR FASTENING SCHEDULEa SECTION R506 CONCRETE FLOORS (ON GROUND) |
109 | FIGURE R505.3.1(1) FLOOR TO LOAD-BEARING WALL STUD CONNECTION FIGURE R505.3.1(2) FLOOR TO WOOD SILL CONNECTION |
110 | FIGURE R505.3.1(3) FLOOR TO FOUNDATION CONNECTION FIGURE R505.3.1(4) FLOOR CANTILEVER TO LOAD-BEARING WALL CONNECTION |
111 | FIGURE R505.3.1(5) FLOOR CANTILEVER TO WOOD SILL CONNECTION FIGURE R505.3.1(6) FLOOR CANTILEVER TO FOUNDATION CONNECTION |
112 | FIGURE R505.3.1(7) CONTINUOUS JOIST SPAN SUPPORTED ON STUD FIGURE R505.3.1(8) LAPPED JOISTS SUPPORTED ON STUD |
113 | TABLE R505.3.2(1) ALLOWABLE SPANS FOR COLD-FORMED STEEL JOISTS—SINGLE SPANSa, b 33 ksi STEEL |
114 | FIGURE R505.3.4 BEARING STIFFENER |
115 | TABLE R505.3.2(2) ALLOWABLE SPANS FOR COLD-FORMED STEEL JOISTS—MULTIPLE SPANSa, b 33 ksi STEEL FIGURE R505.3.6 HOLE PATCH |
116 | TABLE R505.3.2(3) ALLOWABLE SPANS FOR COLD-FORMED STEEL JOISTS—MULTIPLE SPANSa, b 50 ksi STEEL FIGURE R505.3.8 TRACK SPLICE |
117 | CHAPTER 6 WALL CONSTRUCTION SECTION R601 GENERAL SECTION R602 WOOD WALL FRAMING |
120 | TABLE R602.2(1) FASTENER SCHEDULE FOR STRUCTURAL MEMBERS |
121 | TABLE R602.2(1)—(CONTINUED) FASTENER SCHEDULE FOR STRUCTURAL MEMBERS |
122 | TABLE R602.2(2) ALTERNATE ATTACHMENTS |
123 | TABLE R602.2(3) WOOD STRUCTURAL PANEL WALL SHEATHING TABLE R602.2(4) ALLOWABLE SPANS FOR PARTICLEBOARD WALL SHEATHINGa TABLE R602.2(5) SIZE, HEIGHT AND SPACING OF WOOD STUDSa |
124 | FIGURE R602.2(1) TYPICAL WALL, FLOOR AND ROOF FRAMING |
125 | FIGURE R602.2(2) FRAMING DETAILS |
126 | TABLE R602.2.1 MAXIMUM ALLOWABLE LENGTH OF WOOD WALL STUDS EXPOSED TO WIND SPEEDS OF LESS THAN 100 MPHb,c |
127 | TABLE R602.2.1–(CONTINUED) MAXIMUM ALLOWABLE LENGTH OF WOOD WALL STUDS EXPOSED TO WIND SPEEDS OF LESS THAN 100 MPH |
128 | FIGURE R602.2.7(1) NOTCHING AND BORED HOLE LIMITATIONS FOR EXTERIOR WALLS AND BEARING WALLS |
129 | FIGURE R602.2.7(2) NOTCHING AND BORED HOLE LIMITATIONS FOR INTERIOR NONBEARING WALLS FIGURE R602.2.7.1 TOP PLATE FRAMING TO ACCOMMODATE PIPING |
130 | TABLE R602.1.3 MAXIMUM SPANS FOR WOOD STRUCTURAL PANEL BOX HEADERSa FIGURE R602.1.3 TYPICAL WOOD STRUCTURAL PANEL BOX HEADER CONSTRUCTION |
131 | TABLE R602.2.10.1 WALL BRACING |
132 | TABLE R602.2.10.5 LENGTH REQUIREMENTS FOR BRACED WALL PANELS IN A CONTINUOUSLY SHEATHED WALLa,b FIGURE R602.2.10.5 TYPICAL EXTERIOR CORNER FRAMING FOR CONTINUOUS STRUCTURAL PANEL SHEATHING; SHOWING REQUIRED STUD-TO-STUD NAILING |
133 | TABLE R602.2.10.6 MINIMUM WIDTHS AND TIE-DOWN FORCES OF ALTERNATE BRACED WALL PANELS |
134 | FIGURE R602.2.10.6.2 ALTERNATE BRACED WALL PANEL ADJACENT TO A DOOR OR WINDOW OPENING |
135 | SECTION R603 STEEL WALL FRAMING |
136 | TABLE R603.2(1) LOAD-BEARING COLD-FORMED STEEL STUD SIZES TABLE R603.2(2) MINIMUM THICKNESS OF COLD-FORMED STEEL STUDS |
137 | FIGURE R603.2(1) C-SECTION FIGURE R603.2(2) TRACK SECTION |
138 | FIGURE R603.2(3) WEB HOLES TABLE R603.2.4 SCREW SUBSTITUTION FACTOR |
139 | FIGURE R603.3 STEEL WALL CONSTRUCTION TABLE R603.3.1 WALL TO FOUNDATION OR FLOOR CONNECTION REQUIREMENTSa,b,c |
140 | FIGURE R603.3.1(1) WALL TO FOUNDATION CONNECTION FIGURE R603.3.1(2) WALL TO WOOD SILL CONNECTION |
141 | TABLE R603.3.2(1) WALL FASTENING SCHEDULEa TABLE R603.3.2(2) 24-FOOT-WIDE BUILDING SUPPORTING ROOF AND CEILING ONLYa,b,c 33 ksi STEEL |
142 | TABLE R603.3.2(3) 24-FOOT-WIDE BUILDING SUPPORTING ROOF AND CEILING ONLYa,b,c 50 ksi STEEL |
143 | TABLE R603.3.2(4) 28-FOOT-WIDE BUILDING SUPPORTING ROOF AND CEILING ONLYa,b,c 33 ksi STEEL |
144 | TABLE R603.3.2(5) 28-FOOT-WIDE BUILDING SUPPORTING ROOF AND CEILING ONLYa,b,c 50 ksi STEEL |
145 | TABLE R603.3.2(6) 32-FOOT-WIDE BUILDING SUPPORTING ROOF AND CEILING ONLYa,b,c 50 ksi STEEL |
146 | TABLE R603.3.2(7) 32-FOOT-WIDE BUILDING SUPPORTING ROOF AND CEILING ONLYa,b,c 50 ksi STEEL |
147 | TABLE R603.3.2(8) 36-FOOT-WIDE BUILDING SUPPORTING ROOF AND CEILING ONLYa,b,c 33 ksi STEEL |
148 | TABLE R603.3.2(9) 36-FOOT-WIDE BUILDING SUPPORTING ROOF AND CEILING ONLYa,b,c 50 ksi STEEL |
149 | TABLE R603.3.2(10) 40-FOOT-WIDE BUILDING SUPPORTING ROOF AND CEILING ONLYa,b,c 33 ksi STEEL |
150 | TABLE R603.3.2(11) 40-FOOT-WIDE BUILDING SUPPORTING ROOF AND CEILING ONLYa,b,c 50 ksi STEEL |
151 | TABLE R603.3.2(12) 24-FOOT-WIDE BUILDING SUPPORTING ONE FLOOR, ROOF AND CEILINGa,b,c 33 ksi STEEL |
152 | TABLE R603.3.2(13) 24-FOOT-WIDE BUILDING SUPPORTING ONE FLOOR, ROOF AND CEILINGa,b,c 50 ksi STEEL |
153 | TABLE R603.3.2(14) 28-FOOT-WIDE BUILDING SUPPORTING ONE FLOOR, ROOF AND CEILINGa,b,c 33 ksi STEEL |
154 | TABLE R603.3.2(15) 28-FOOT-WIDE BUILDING SUPPORTING ONE FLOOR, ROOF AND CEILINGa,b,c 50 ksi STEEL |
155 | TABLE R603.3.2(16) 32-FOOT-WIDE BUILDING SUPPORTING ONE FLOOR, ROOF AND CEILINGa,b,c 33 ksi STEEL |
156 | TABLE R603.3.2(17) 32-FOOT-WIDE BUILDING SUPPORTING ONE FLOOR, ROOF AND CEILINGa,b,c 50 ksi STEEL |
157 | TABLE R603.3.2(18) 36-FOOT-WIDE BUILDING SUPPORTING ONE FLOOR, ROOF AND CEILINGa,b,c 33 ksi STEEL |
158 | TABLE R603.3.2(19) 36-FOOT-WIDE BUILDING SUPPORTING ONE FLOOR, ROOF AND CEILINGa,b,c 50 ksi STEEL |
159 | TABLE R603.3.2(20) 40-FOOT-WIDE BUILDING SUPPORTING ONE FLOOR, ROOF AND CEILINGa,b,c 33 ksi STEEL |
160 | TABLE R603.3.2(21) 40-FOOT-WIDE BUILDING SUPPORTING ONE FLOOR, ROOF AND CEILINGa,b,c 50 ksi STEEL |
161 | FIGURE R603.3.5 HOLE PATCH |
162 | FIGURE R603.3.6 TRACK SPLICE SECTION R604 WOOD STRUCTURAL PANELS SECTION R605 PARTICLEBOARD |
163 | FIGURE R603.4 CORNER FRAMING SECTION R606 GENERAL MASONRY CONSTRUCTION |
164 | FIGURE R603.6 HEADER DETAIL |
165 | TABLE R603.6(1) BOX-BEAM HEADER SPANS HEADERS SUPPORTING ONE FLOOR, ROOF AND CEILING ONLY (33 ksi STEEL)a,b,c TABLE R603.6(2) BOX-BEAM HEADER SPANS RESERVED |
166 | TABLE R603.6(3) BOX-BEAM HEADER SPANS HEADERS SUPPORTING ONE FLOOR, ROOF AND CEILING (33 ksi STEEL)a, b, c TABLE R603.6(4) BOX-BEAM HEADER SPANS RESERVED |
167 | TABLE R603.6(5) BACK-TO-BACK HEADER SPANS HEADERS SUPPORTING ONE FLOOR, ROOF AND CEILING ONLY (33 ksi STEEL)a, b, c TABLE R603.6(6) BACK-TO-BACK HEADER SPANS RESERVED |
168 | TABLE R603.6(7) BACK-TO-BACK HEADER SPANS HEADERS SUPPORTING ONE FLOOR, ROOF AND CEILING (33 ksi STEEL) a, b, c TABLE R603.6(8) BACK-TO-BACK HEADER SPANS RESERVED |
169 | TABLE R603.6(9) TOTAL NUMBER OF JACK AND KING STUDS REQUIRED AT EACH END OF AN OPENING TABLE R603.6(10) HEADER TO KING STUD CONNECTION REQUIREMENTSa, b, c, d TABLE R603.6(11) HEAD TRACK SPAN (33 ksi STEEL) |
170 | TABLE R603.7 MINIMUM PERCENTAGE OF FULL HEIGHT STRUCTURAL SHEATHING ON EXTERIOR WALLSa,b,c,d,e |
171 | TABLE 606.8 SPACING OF LATERAL SUPPORT FOR MASONRY WALLS RESERVED FIGURE R606.10(1) ANCHORAGE REQUIREMENTS FOR MASONRY WALLS LOCATED IN SEISMIC DESIGN CATEGORY A, B OR C AND WHERE WIND LOADS ARE LESS THAN 30 PSF RESERVED FIGURE R606.10(2) REQUIREMENTS FOR REINFORCED GROUTED MASONRY CONSTRUCTION IN SEISMIC DESIGN CATEGORY C RESERVED FIGURE R606.10(3) REQUIREMENTS FOR REINFORCED MASONRY CONSTRUTION IN SEISMIC DESIGN CATEGORY D1 OR D2 RESERVED TABLE R606.11.3.2 MINIMUM DISTRIBUTED WALL REINFORCEMENT FOR BUILDINGS ASSIGNED TO SEISMIC DESIGN CATEGORY D1 RESERVED TABLE R606.11.4.1 MINIMUM CORROSION PROTECTION RESERVED TABLE R606.11.4.2 MINIMUM REINFORCING FOR STACKED BONDED MASONRY WALLS IN SEISMIC DEISGN CATEGORY D2 RESERVED TABLE R606.9.2 LAP SPLICE LENGTHS |
172 | FIGURE R606.9.9A CONTINUITY OF REINFORCEMENT ONE STORY MASONRY WALL |
173 | FIGURE R606.9.9B CONTINUITY OF FIRST AND SECOND FLOOR VERTICAL WALL REINFORCEMENT |
174 | TABLE R606.9.10.1 MINIMUM CORROSION PROTECTION TABLE R607.1 MORTAR PROPORTIONSa,b |
175 | SECTION R607 UNIT MASONRY SECTION R608 MULTIPLE WYTHE MASONRY |
176 | SECTION R609 GROUTED MASONRY TABLE R609.1.1 GROUT PROPORTIONS BY VOLUME FOR MASONRY CONSTRUCTION |
177 | TABLE R609.2.2C BOND BEAM AREA OF STEEL PROVIDED IN2/FT |
178 | FIGURE R609.2.4 CORNER CONTINUITY OF BOND BEAM AND WALL REINFORCEMENT FIGURE R609.2.5 CHANGES IN BOND BEAM HEIGHT |
179 | TABLE R609.2.2A-1 GRADE 60 EXPOSURE B ROOF DIAPHRAGM CHORD TENSION BOND BEAM STEEL AREA, IN2 |
180 | TABLE R609.2.2A-2 GRADE 60 ROOF EXPOSURE C DIAPHRAGM CHORD TENSION BOND BEAM STEEL AREA, IN2 |
181 | TABLE R609.2.2A-3 GRADE 40 EXPOSURE B ROOF DIAPHRAGM CHORD TENSION BOND BEAM STEEL AREA, IN2 |
182 | TABLE R609.2.2A-4 GRADE 40 EXPOSURE C ROOF DIAPHRAGM CHORD TENSION BOND BEAM STEEL AREA, IN2 |
183 | TABLE R609.2.2B-1 GRADE 60 AREA OF STEEL REQUIRED IN BOND BEAM FOR UPLIFT BENDING, IN2 |
184 | TABLE R609.2.2B-2 GRADE 60 AREA OF STEEL REQUIRED IN BOND BEAM FOR UPLIFT BENDING, IN2 |
185 | TABLE R609.2.2B-3 GRADE 60 AREA OF STEEL REQUIRED IN BOND BEAM FOR UPLIFT BENDING, IN2 |
186 | TABLE R609.2.2B-4 GRADE 60 AREA OF STEEL REQUIRED IN BOND BEAM FOR UPLIFT BENDING, IN2 |
187 | TABLE R609.2.2B-5 GRADE 40 AREA BOND BEAM/LINTEL UPLIFT STEEL DESIGN |
188 | TABLE R609.2.2B-6 GRADE 40 AREA BOND BEAM/LINTEL UPLIFT STEEL DESIGN |
189 | TABLE R609.2.2B-7 GRADE 40 AREA BOND BEAM/LINTEL UPLIFT STEEL DESIGN |
190 | TABLE R609.2.2B-8 GRADE 40 AREA BOND BEAM/LINTEL UPLIFT STEEL DESIGN |
191 | TABLE R609.3.3A-1 GRADE 60 SINGLE STORY AND TOP STORY WALLS PARALLEL TO RIDGE VERTICAL REINFORCEMENT SPACING NO. 5 BARS (5/8 IN.) |
192 | TABLE R609.3.3A-2 GRADE 60 SINGLE STORY AND TOP STORY WALLS PARALLEL TO RIDGE VERTICAL REINFORCEMENT SPACING NO. 4 BARS (1/2 IN.) |
193 | TABLE R609.3.3A-3 GRADE 40 SINGLE STORY AND TOP STORY WALLS PARALLEL TO RIDGE VERTICAL REINFORCEMENT SPACING NO. 5 BARS (5/8 IN.) |
194 | TABLE R609.3.3A-4 GRADE 40 SINGLE STORY AND TOP STORY WALLS PARALLEL TO RIDGE VERTICAL REINFORCEMENT SPACING NO. 4 BARS (1/2 IN.) |
195 | TABLE R609.3.3B-1 GRADE 60 MAXIMUM SPACING OF NO. 5 (5/8 IN.) VERTICAL REINFORCEMENT AT CONTINUOUS CONCRETE MASONRY LOWER STORIES OF MULTISTORY AND GABLE ENDS SINGLE STORY OR TOP STORY OF MULTISTORY, FEET |
196 | TABLE R609.3.3B-2 GRADE 60 MAXIMUM SPACING OF NO. 4 (1/2 IN.) VERTICAL REINFORCEMENT AT CONTINUOUS MASONRY LOWER STORIES OF MULTISTORY AND GABLE ENDS SINGLE STORY OR TOP STORY OF MULTISTORY, FEET |
197 | TABLE R609.3.3B-3 GRADE 40 MAXIMUM SPACING OF NO. 5 (5/8 IN.) VERTICAL REINFORCEMENT AT CONTINUOUS CONCRETE MASONRY LOWER STORIES OF MULTISTORY AND GABLE ENDS SINGLE STORY OR TOP STORY OF MULTISTORY, FEET |
198 | TABLE R609.3.3B-4 GRADE 40 MAXIMUM SPACING OF NO. 4 (1/2 IN.) VERTICAL REINFORCEMENT AT CONTINUOUS CONCRETE OR MASONRY LOWER STORIES OF MULTISTORY AND GABLE ENDS SINGLE STORY OR TOP STORY OF MULTISTORY, FEET |
199 | TABLE R609.4A WOOD GABLE BRACE NAILING TABLE R609.4B WOOD GABLE STUD CONNECTOR LOADS |
200 | FIGURE R609.4 GABLE END BRACING FOR MASONRY WALLS NOT CONTINUOUS TO THE ROOF DIAPHRAGM |
201 | FIGURE R609.4.1 CONTINUOUS GABLE ENDWALL REINFORCEMENT ONE AND MULTISTORY |
202 | FIGURE R609.4.5 GABLE OVERHANG |
203 | TABLE R609.4.4 ANCHOR BOLT SPACING FOR ATTACHING2 4 MINIMUM WOOD NAILER TO RAKE BEAM |
204 | TABLE R609.5.1A GRADE 60 REQUIRED SHEARWALL LENGTH PARALLEL TO RIDGE NO. 4 REINFORCEMENT1,2,3,5 ROOF ANGLE 23° |
205 | TABLE R609.5.1B GRADE 60 REQUIRED SHEARWALL LENGTH PARALLEL TO RIDGE NO. 4 REINFORCEMENT1,2,3,5 ROOF ANGLE 30° |
206 | TABLE R609.5.1C GRADE 60 REQUIRED SHEARWALL LENGTH PARALLEL TO RIDGE NO. 4 REINFORCEMENT1,2,3,5 ROOF ANGLE 45° |
207 | TABLE R609.5.1D GRADE 60 REQUIRED SHEARWALL LENGTH PERPENDICULAR TO RIDGE NO. 4 REINFORCEMENT PER FOOT OF BUILDING LENGTH1,2,3,4,5 ROOF ANGLE 23° |
208 | TABLE R609.5.1E GRADE 60 REQUIRED SHEARWALL LENGTH PERPENDICULAR TO RIDGE NO. 4 REINFORCEMENT PER FOOT OF BUILDING LENGTH1,2,3,4,5 ROOF ANGLE 30° |
209 | TABLE R609.5.1F GRADE 60 REQUIRED SHEARWALL LENGTH PERPENDICULAR TO RIDGE NO. 4 REINFORCEMENT PER FOOT OF BUILDING LENGTH1,2,3,4,5 ROOF ANGLE 45° |
210 | TABLE R609.5.1G GRADE 40 REQUIRED SHEARWALL LENGTH PARALLEL TO RIDGE NO. 4 REINFORCEMENT1, 2, 3, 5 ROOF ANGLE 23° |
211 | TABLE R609.5.1H GRADE 40 REQUIRED SHEARWALL LENGTH PARALLEL TO RIDGE NO. 5 REINFORCEMENT1, 2, 3, 6 ROOF ANGLE 23° |
212 | TABLE R609.5.1I GRADE 40 REQUIRED SHEARWALL LENGTH PARALLEL TO RIDGE NO. 4 REINFORCEMENT1, 2, 3, 5 ROOF ANGLE 30° |
213 | TABLE R609.5.1J GRADE 40 REQUIRED SHEARWALL LENGTH PARALLEL TO RIDGE NO. 5 REINFORCEMENT1, 2, 3, 6 ROOF ANGLE 30° |
214 | TABLE R609.5.1K GRADE 40 REQUIRED SHEARWALL LENGTH PARALLEL TO RIDGE NO. 4 REINFORCEMENT1, 2, 3, 5 ROOF ANGLE 45° |
215 | TABLE R609.5.1L GRADE 40 REQUIRED SHEARWALL LENGTH PARALLEL TO RIDGE NO. 5 REINFORCEMENT1, 2, 3, 6 ROOF ANGLE 45° |
216 | TABLE R609.5.1M GRADE 40 REQUIRED SHEARWALL LENGTH PERPENDICULAR TO RIDGE NO. 4 REINFORCEMENT PER FOOT OF BUILDING LENGTH1, 2, 3, 4, 5 ROOF ANGLE 23° |
217 | TABLE R609.5.1N GRADE 40 REQUIRED SHEARWALL LENGTH PERPENDICULAR TO RIDGE NO. 5 REINFORCEMENT PER FOOT OF BUILDING LENGTH1, 2, 3, 4, 6 ROOF ANGLE 23° |
218 | TABLE R609.5.1O GRADE 40 REQUIRED SHEARWALL LENGTH PERPENDICULAR TO RIDGE NO. 4 REINFORCEMENT PER FOOT OF BUILDING LENGTH1, 2, 3, 4, 5 ROOF ANGLE 30° |
219 | TABLE R609.5.1P GRADE 40 REQUIRED SHEARWALL LENGTH PERPENDICULAR TO RIDGE NO. 5 REINFORCEMENT PER FOOT OF BUILDING LENGTH1, 2, 3, 4, 6 ROOF ANGLE 30° |
220 | TABLE R609.5.1Q GRADE 40 REQUIRED SHEARWALL LENGTH PERPENDICULAR TO RIDGE NO. 4 REINFORCEMENT PER FOOT OF BUILDING LENGTH1, 2, 3, 4, 5 ROOF ANGLE 45° |
221 | TABLE R609.5.1R GRADE 40 REQUIRED SHEARWALL LENGTH PERPENDICULAR TO RIDGE NO. 5 REINFORCEMENT PER FOOT OF BUILDING LENGTH1, 2, 3, 4, 6 ROOF ANGLE 45° |
222 | TABLE R609.5.1S SHEARWALL LENGTH ADJUSTMENT FACTOR GRADE 40 STEEL TABLE R609.5.3A TOTAL SHEAR AT TOP OF TOP STORY WALL1,2 |
223 | TABLE R609.5.3B TRANSVERSE CONNECTOR LOAD (F2)1, 2 FIGURE R609.5.3 TYPICAL ROOF TO WALL CONNECTIONS |
224 | TABLE R609.5.4 END WALL ROOF SHEAR PER FOOT OF BUILDING LENGTH |
225 | TABLE R609.6.1.2(1) SUPERIMPOSED LOADS MINIMUM RATED LOAD CAPACITY OF 6-INCH- OR 8-INCH-THICK PRE-ENGINEERED ASSEMBLIES SPANNING OPENINGS OF ONE STORY AND TOP STORY OF MULTI-STORY BUILDINGS1, 3, 4 |
226 | TABLE R609.6.1.2(2) SUPERIMPOSED LOADS MINIMUM RATED LOAD CAPACITY 8-INCH-THICK PREENGINEERED ASSEMBLIES SPANNING OPENINGS OF BOTTOM STORY OF TWO-STORY BUILDINGS, SECOND AND BOTTOM STORIES OF THREE-STORY BUILDINGS—WOOD FLOOR SYSTEM3, 4, 5 |
227 | TABLE R609.6.1.2(3) SUPERIMPOSED LOADS MINIMUM RATED LOAD CAPACITY 8-INCH-THICK PREENGINEERED ASSEMBLIES SPANNING OPENINGS OF BOTTOM STORY OF TWO-STORY BUILDINGS, SECOND AND BOTTOM STORIES OF THREE-STORY BUILDINGS—HOLLOWCORE FLOOR SYSTEM3, 4, 5 |
228 | TABLE R609.6.2.1(1) MAXIMUM CLEAR SPAN CAPACITY OF CONTINUOUS BOND BEAMS ACTING AS LINTELS ONE STORY AND TOP STORY OF MULTISTORY BUILDINGS |
229 | TABLE R609.6.2.1(2) MAXIMUM CLEAR SPAN OF CONTINUOUS BOND BEAMS ACTING AS LINTELS BOTTOM STORY OF TWO-STORY BUILDINGS, SECOND AND BOTTOM STORIES OF THREE-STORY BUILDINGS—WOOD FLOOR SYSTEM |
230 | TABLE R609.6.2.1(3) MAXIMUM CLEAR SPAN OF CONTINUOUS BOND BEAMS ACTING LINTELS BOTTOM STORY OF TWO-STORY BUILDINGS, SECOND AND BOTTOM STORIES OF THREE-STORY BUILDINGS—HOLLOWCORE SECOND FLOOR |
231 | TABLE R609.6.3.2(1) COMBINED BOND BEAM/LINTELS ONE STORY AND TOP STORY OF MULTISTORY BUILDINGS |
232 | TABLE R609.6.3.2(2) COMBINED BOND BEAM/LINTELS BOTTOM STORY OF TWO-STORY BUILDINGS, SECOND AND BOTTOM STORIES OF THREE-STORY BUILDINGS—WOOD FLOOR SYSTEM |
233 | TABLE R609.6.3.2(3) COMBINED BOND BEAM/LINTELS BOTTOM STORY OF TWO-STORY BUILDINGS, SECOND AND BOTTOM STORIES OF THREE-STORY BUILDINGS—HOLLOWCORE FLOOR SYSTEM |
234 | SECTION R610 GLASS UNIT MASONRY FIGURE R610.4.1 GLASS UNIT MASONRY DESIGN WIND LOAD RESISTANCE |
235 | SECTION R611 INSULATING CONCRETE FORMWALL CONSTRUCTION |
236 | TABLE R611.2 REQUIREMENTS FOR ICF WALLSb FIGURE R611.3 FLAT ICF WALL SYSTEM TABLE R611.3(1) DESIGN WIND PRESSURE FOR USE WITH TABLES R611.3(2), R611.4(1), AND R611.5 FOR ABOVE GRADE WALLSa |
237 | TABLE R611.3(2) MINIMUM VERTICAL WALL REINFORCEMENT FOR FLAT ICF ABOVE-GRADE WALLSa,b,c,d FIGURE R611.4 WAFFLE-GRID ICF WALL SYSTEM |
238 | TABLE R611.4(1) MINIMUM VERTICAL WALL REINFORCEMENT FOR WAFFLE-GRID ICF ABOVE-GRADE WALLSa, b, c |
239 | FIGURE R611.5 SCREEN-GRID IFC WALL SYSTEM TABLE R611.5 MINIMUM VERTICAL WALL REINFORCEMENT FOR SCREEN-GRID ICF ABOVE-GRADE WALLSa,b,c |
240 | TABLE R611.7(1) MINIMUM WALL OPENING REINFORCEMENT REQUIREMENTS IN ICF WALLS |
242 | TABLE R611.7(2) MAXIMUM ALLOWABLE CLEAR SPANS FOR ICF LINTELS FOR FLAT LOAD-BEARING WALLSa,b,c,d,f NO. 4 BOTTOM BAR SIZE |
243 | TABLE R611.7(3) MAXIMUM ALLOWABLE CLEAR SPANS FOR ICF LINTELS FOR FLAT LOAD-BEARING WALLS a,b,c,d,f NO. 5 BOTTOM BAR SIZE |
244 | TABLE R611.7(4) MAXIMUM ALLOWABLE CLEAR SPANS FOR WAFFLE-GRID ICF WALL LINTELSa,b,c,d,f NO. 4 BOTTOM BAR SIZE |
245 | TABLE R611.7(5) MAXIMUM ALLOWABLE CLEAR SPANS FOR WAFFLE-GRID ICF WALL LINTELSa,b,c,d,f NO. 5 BOTTOM BAR SIZE |
246 | TABLE R611.7(6) MAXIMUM ALLOWABLE CLEAR SPANS FOR SCREEN-GRID ICF LINTELS IN LOAD-BEARING WALLSa,b,c,d,e,f NO. 4 BOTTOM BAR SIZE TABLE R611.7(7) MAXIMUM ALLOWABLE CLEAR SPANS FOR SCREEN-GRID ICF LINTELS IN LOAD-BEARING WALLSa,b,c,d,e,f NO. 5 BOTTOM BAR SIZE |
247 | TABLE R611.7(8) MAXIMUM ALLOWABLE CLEAR SPANS FOR ICF LINTELS WITHOUT STIRRUPS IN LOAD-BEARING WALLSa,b,c,d,e,f,g,h(NO. 4 OR NO. 5) BOTTOM BAR SIZE |
248 | TABLE R611.7(9) MINIMUM BOTTOM BAR ICF LINTEL REINFORCEMENT FOR LARGE CLEAR SPANS IN LOAD-BEARING WALLSa,b,c,d,e,f,h |
249 | TABLE R611.7(9A) MINIMUM SOLID END WALL LENGTH REQUIREMENTS FOR FLAT ICF WALLS (WIND PERPENDICULAR TO RIDGE)a,b,c |
250 | TABLE R611.7(9B) MINIMUM SOLID SIDE WALL LENGTH REQUIREMENTS FOR FLAT ICF WALLS (WIND PARALLEL TO RIDGE) a, b, c, d |
251 | TABLE R611.7(10) MAXIMUM ALLOWABLE CLEAR SPANS FOR ICF LINTELS IN NON-LOAD-BEARING WALLS WITHOUT STIRRUPSa, b, c, d NO. 4 BOTTOM BAR |
252 | TABLE R611.7(10A) MINIMUM SOLID END WALL LENGTH REQUIREMENTS FOR WAFFLE AND SCREEN-GRID ICF WALLS (WIND PERPENDICULAR TO RIDGE)a,b,c |
253 | TABLE R611.7(10A)—continued MINIMUM SOLID END WALL LENGTH REQUIREMENTS FOR WAFFLE AND SCREEN-GRID ICF WALLS (WIND PERPENDICULAR TO RIDGE)a,b,c TABLE R611.7(10B) MINIMUM SOLID SIDE WALL LENGTH REQUIREMENTS FOR 6-INCH WAFFLE AND SCREEN-GRID ICF WALLS (WIND PARALLEL TO RIDGE)a,b,c,d |
254 | FIGURE R611.7(1) ICF WALL CONSTRUCTION FIGURE R611.7(2) REINFORCEMENT OF OPENINGS |
255 | FIGURE R611.7(3) ICF LINTELS FOR FLAT AND SCREEN-GRID WALLS FIGURE R611.7(4) SINGLE FORM HEIGHT WAFFLE-GRID LINTEL |
256 | FIGURE R611.7(5) DOUBLE FORM HEIGHT WAFFLE-GRID LINTEL FIGURE R611.7(6) SINGLE FORM HEIGHT SCREEN-GRID LINTEL |
257 | FIGURE R611.7(7) DOUBLE FORM HEIGHT SCREEN-GRID LINTEL FIGURE R611.7.1.4 LAP SPLICES |
258 | FIGURE R611.7.4 MINIMUM SOLID WALL LENGTH |
259 | TABLE R611.7.4 WIND VELOCITY PRESSURE FOR DETERMINATION OF MINIMUM SOLID WALL LENGTHa SECTION R612 CONVENTIONALLY FORMED CONCRETE WALL CONSTRUCTION SECTION R613 EXTERIOR WINDOWS AND DOOR ASSEMBLIES |
260 | TABLE R611.8(1) FLOOR LEDGER-ICF WALL CONNECTION (SIDE-BEARING CONNECTION) REQUIREMENTSa,b,c FIGURE R611.8(1) SECTION CUT THROUGH FLAT WALL OR VERTICAL CORE OF WAFFLE- OR SCREEN-GRID WALL |
261 | FIGURE R611.8(2) FLOOR LEDGER—ICF WALL CONNECTION (SIDE-BEARING CONNECTION) FIGURE R611.8(3) FLOOR LEDGER—ICF WALL CONNECTION (LEDGE-BEARING CONNECTION) |
262 | FIGURE R611.8(4) WOOD FLOOR LEDGER—ICF WALL SYSTEM CONNECTION (THROUGH-BOLT SIDE-BEARING CONNECTION) FIGURE R611.8(5) FLOOR LEDGER—ICF WALL CONNECTION (THROUGH-BOLT-LEDGE-BEARING CONNECTION) |
263 | FIGURE R611.8(6) ANCHORAGE REQUIREMENTS FOR TOP BEARING WALLS FOR TOWNHOUSES AND ALL BUILDINGS FOR FLOOR FRAMING PARALLEL TO WALL FIGURE R611.8(7) ANCHORAGE REQUIREMENTS FOR LEDGER BEARING WALLS FOR TOWNHOUSES AND ALL BUILDINGS FOR FLOOR FRAMING PARALLEL TO WALL |
264 | TABLE R611.9 DESIGN TENSILE STRENGTH OF HEADED BOLTS CAST IN CONCRETEa FIGURE R611.9 ROOF SILL PLATE—ICF WALL CONNECTION |
267 | TABLE R613.4 MINIMUM TEST SIZES, INCLUDING FRAMING |
268 | SECTION R614 COMBINED CONCRETE, MASONRY, OR ICF AND WOOD EXTERIOR WALL CONSTRUCTION SECTION R615 IMPACT-RESISTANT COVERINGS |
269 | FIGURE R614.3(1) DIRECT TRUSS TO CONCRETE, MASONRY OR ICF WALL CONNECTION FOR GYPSUM BOARD CEILING DIAPHRAGM FIGURE R614.3(2) DIRECT TRUSS TO CONCRETE, MASONRY OR ICF WALL FOR GYPSUM BOARD CEILING DIAPHRAGM |
270 | SECTION R616 PRESCRIPTIVE REQUIREMENTS FOR WINDOW INSTALLATION IN WOOD FRAME CONSTRUCTION |
273 | CHAPTER 7 WALL COVERING SECTION R701 GENERAL SECTION R702 INTERIOR COVERING TABLE R702.1(1) THICKNESS OF PLASTER |
274 | TABLE R702.1(2) GYPSUM PLASTER PROPORTIONSa TABLE R702.1(3) PORTLAND CEMENT PLASTER |
275 | TABLE R702.3.5 MINIMUM THICKNESS AND APPLICATION OF GYPSUM BOARD |
276 | TABLE R702.3.7 SHEAR CAPACITY FOR HORIZONTAL WOOD-FRAMED GYPSUM BOARD DIAPHRAGM CEILING ASSEMBLIES SECTION R703 EXTERIOR COVERING |
278 | TABLE R703.3.3(1) WOOD, HARDBOARD AND WOOD STRUCTURAL PANEL SIDING ATTACHMENT EXPOSURE CATEGORY B |
279 | TABLE R703.3.3(2) WOOD, HARDBOARD AND WOOD STRUCTURAL PANEL SIDING ATTACHMENT EXPOSURE CATEGORY C |
280 | TABLE R703.3.3(3) SPECIFIC GRAVITIES OF SOLID SAWN LUMBER |
281 | TABLE R703.3.4(1) WOOD, HARDBOARD AND WOOD STRUCTURAL PANEL SIDING MINIMUM THICKNESS EXPOSURE CATEGORY B TABLE R703.3.4(2) WOOD, HARDBOARD AND WOOD STRUCTURAL PANEL SIDING MINIMUM THICKNESS EXPOSURE CATEGORY C |
282 | TABLE R703.4 WEATHER–RESISTANT SIDING ATTACHMENT AND MINIMUM THICKNESS |
283 | TABLE R703.5.2 MAXIMUM WEATHER EXPOSURE FOR WOOD SHAKES AND SHINGLES ON EXTERIOR WALLSA,B,C (DIMENSIONS ARE IN INCHES) |
285 | FIGURE R703.7 MASONRY VENEER WALL DETAILS |
286 | FIGURE R703.7—(CONTINUED) MASONRY VENEER WALL DETAILS |
287 | FIGURE R703.7.2.1 EXTERIOR MASONRY VENEER SUPPORT BY STEEL ANGLES FIGURE R703.7.2.2 EXTERIOR MASONRY VENEER SUPPORT BY ROOF MEMBERS |
288 | TABLE R703.7.3 ALLOWABLE SPANS FOR LINTELS SUPPORTING MASONRY VENEERa, b, c |
289 | TABLE R703.13 MINIMUM THICKNESS OF WEATHER COVERINGS |
290 | TABLE R703.13 MINIMUM THICKNESS OF WEATHER COVERINGS – (CONTINUED) SECTION R704 INSPECTION FOR TERMITES |
291 | CHAPTER 8 ROOF-CEILING CONSTRUCTION SECTION R801 GENERAL SECTION R802 WOOD ROOF FRAMING |
294 | TABLE R802.2(1) CEILING JOIST SPANS FOR COMMON LUMBER SPECIES (UNINHABITABLE ATTICS WITHOUT STORAGE, LIVE LOAD = 10 PSF, L/Δ = 240) |
295 | TABLE R802.2(1)—CONTINUED CEILING JOIST SPANS FOR COMMON LUMBER SPECIES UNINHABITABLE ATTICS WITHOUT STORAGE, LIVE LOAD = 10 PSF, L/Δ = 240) |
296 | TABLE R802.2(2) CEILING JOIST SPANS FOR COMMON LUMBER SPECIES (UNINHABITABLE ATTICS WITH LIMITED STORAGE, LIVE LOAD = 20 PSF, L/Δ = 240) |
297 | TABLE R802.2(2) (CONTINUED) CEILING JOIST SPANS FOR COMMON LUMBER SPECIES (UNINHABITABLE ATTICS WITH LIMITED STORAGE, LIVE LOAD = 20 PSF, L/Δ = 240) |
298 | TABLE R802.2.3(1) RAFTER SPANS FOR COMMON LUMBER SPECIES (ROOF LIVE LOAD=20 PSF, CEILING NOT ATTACHED TO RAFTERS, L/Δ = 180) |
299 | TABLE R802.2.3(1)— CONTINUED RAFTER SPANS FOR COMMON LUMBER SPECIES (ROOF LIVE LOAD=20 PSF, CEILING NOT ATTACHED TO RAFTERS, L/Δ = 180) |
300 | TABLE R802.2.3(2) RAFTER SPANS FOR COMMON LUMBER SPECIES ROOF LIVE LOAD=20 PSF, CEILING ATTACHED TO RAFTERS, L/Δ = 240) |
301 | TABLE R802.2.3(2) (CONTINUED) RAFTER SPANS FOR COMMON LUMBER SPECIES ROOF LIVE LOAD=20 PSF, CEILING ATTACHED TO RAFTERS, L/Δ = 240) TABLES R802.5.1(3) THROUGH R802.5.1(8) RESERVED |
302 | TABLE R802.2.3(9) RAFTER/CEILING JOIST HEEL JOINT CONNECTIONSa, b, c, d, e, f, g |
303 | FIGURE R802.2.3.1 BRACED RAFTER CONSTRUCTION SECTION R803 ROOF SHEATHING |
304 | TABLE R802.2.9.1 WIND UPLIFT FORCESa,b,c,e,f ROOF BEARING UPLIFT EXPOSURE B FIGURE R803.2.3.1 ROOF SHEATHING NAILING ZONES |
305 | TABLE R802.2.9.1 (CONTINUED) WIND UPLIFT FORCESa,b,c,e,f ROOF BEARING UPLIFT EXPOSURE C |
306 | TABLE R803.1 MINIMUM THICKNESS OF LUMBER ROOF SHEATHING SECTION R804 STEEL ROOF FRAMING |
307 | TABLE R804.2(1) LOAD-BEARING COLD-FORMED STEEL MEMBER SIZES TABLE R804.2(2) MINIMUM THICKNESS OF COLD-FORMED STEEL ROOF FRAMING MEMBERS FIGURE R804.2(1) C-SECTION FIGURE R804.2(2) TRACK SECTION |
308 | FIGURE R804.2(3) WEB HOLES TABLE R804.2.4 SCREW SUBSTITUTION FACTOR |
309 | TABLE R804.3 ROOF FRAMING FASTENING SCHEDULEa,b FIGURE R804.3 STEEL ROOF CONSTRUCTION |
310 | TABLE R804.3.1(1) CEILING JOIST SPANS SINGLE SPANS WITH BEARING STIFFENERS 10 lb per sq ft LIVE LOAD (NO ATTIC STORAGE)a,b,c 33 ksi STEEL |
311 | SECTION R805 CEILING FINISHES SECTION R806 ROOF VENTILATION |
312 | TABLE R804.3.1(3) CEILING JOIST SPANS SINGLE SPANS WITH BEARING STIFFENERS 20 lb per sq ft LIVE LOAD (LIMITED ATTIC STORAGE)a, b, c 33 ksi STEEL |
313 | TABLE R804.3.1(4) CEILING JOIST SPANS TWO EQUAL SPANS WITH BEARING STIFFENERS 20 lb per sq ft LIVE LOAD (LIMITED ATTIC STORAGE)a, b, c 33 ksi STEEL |
314 | TABLE R804.3.1(5) CEILING JOIST SPANS SINGLE SPANS WITHOUT BEARING STIFFENERS 10 lb per sq ft LIVE LOAD (NO ATTIC STORAGE)a, b 33 ksi STEEL |
315 | TABLE R804.3.1(6) CEILING JOIST SPANS TWO EQUAL SPANS WITHOUT BEARING STIFFENERS 10 lb per sq ft LIVE LOAD (NO ATTIC STORAGE)a, b 33 ksi STEEL |
316 | TABLE R804.3.1(7) CEILING JOIST SPANS SINGLE SPANS WITHOUT BEARING STIFFENERS 20 LB PER SQ FT LIVE LOAD (LIMITED ATTIC STORAGE)a, b 33 ksi STEEL |
317 | TABLE R804.3.1(8) CEILING JOIST SPANSTWO EQUAL SPANS WITHOUT BEARING STIFFENERS 20 LB PER SQ FT LIVE LOAD (LIMITED ATTIC STORAGE)a, b 33 ksi STEEL |
318 | FIGURE R804.3.1(1) JOIST TO RAFTER CONNECTION TABLE R804.3.1 NUMBER OF SCREWS REQUIRED FOR CEILING JOIST TO RAFTER CONNECTIONa |
319 | TABLE R804.3.3(1) ALLOWABLE HORIZONTAL RAFTER SPANSa, b TABLE R804.3.3(2) BASIC WIND SPEED AND ROOF SLOPE CONVERSION [NOTE: TABLE IS LIMITED TO AREAS WHERE WIND SPEED (MPH) IS LESS THAN 100, SEE SECTION R301.2.1.1] TABLE R804.3.3.1 NUMBER OF SCREWS REQUIRED AT EACH LEG OF CLIP ANGLE FOR RAFTER TO RIDGE MEMBER CONNECTIONa |
320 | FIGURE R804.3.3.1 RIDGE BOARD CONNECTION SECTION R807 ATTIC ACCESS SECTION R808 INSULATION CLEARANCE |
321 | FIGURE R804.3.6 HOLE PATCHING FIGURE R804.3.7(1) SPLICED CEILING JOISTS |
322 | FIGURE R804.3.7(2) TRACK SPLICE FIGURE R804.3.8 BEARING STIFFENER |
323 | FIGURE R804.3.10(1) ROOF OPENING FIGURE R804.3.10(2) HEADER TO TRIMMER CONNECTION |
325 | CHAPTER 9 ROOF ASSEMBLIES SECTION R901 GENERAL SECTION R902 ROOF CLASSIFICATION SECTION R903 WEATHER PROTECTION TABLE R903.2.1 METAL FLASHING MATERIAL |
326 | SECTION R904 MATERIALS SECTION R905 REQUIREMENTS FOR ROOF COVERINGS |
327 | TABLE R905.2.6.1 WIND RESISTANCE OF ASPHALT SHINGLES |
329 | TABLE R905.4.4 METAL ROOF COVERINGS |
330 | TABLE R905.6.5 SLATE SHINGLE HEADLAP TABLE R905.7.4 WOOD SHINGLE MATERIAL REQUIREMENTS TABLE R905.7.5 WOOD SHINGLE AND SHAKE INSTALLATION |
331 | TABLE R905.7.7 WOOD SHAKE WEATHER EXPOSURE AND ROOF SLOPE TABLE R905.8.5 WOOD SHAKE MATERIAL REQUIREMENTS |
332 | TABLE R905.8.8 WOOD SHAKE WEATHER EXPOSURE AND ROOF SLOPE |
333 | TABLE R905.9.2 BUILT-UP ROOFING MATERIAL STANDARDS |
334 | TABLE R905.11.2 MODIFIED BITUMEN ROOFING MATERIAL STANDARDS |
335 | SECTION R906 ROOF INSULATION TABLE R906.2 MATERIAL STANDARDS FOR ROOF INSULATION SECTION R907 REROOFING |
337 | CHAPTER 10 CHIMNEYS AND FIREPLACES SECTION R1001 MASONRY FIREPLACES |
338 | TABLE R1001.1 SUMMARY OF REQUIREMENTS FOR MASONRY FIREPLACES AND CHIMNEYS |
339 | FIGURE R1001.1 FIREPLACE AND CHIMNEY DETAILS |
340 | FIGURE R1001.11 CLEARANCE FROM COMBUSTIBLES SECTION R1002 MASONRY HEATERS |
341 | SECTION R1003 MASONRY CHIMNEYS |
343 | TABLE R1003.14(1) NET CROSS–SECTIONAL AREA OF ROUND FLUE SIZESa TABLE R1003.14(2) NET CROSS–SECTIONAL AREA OF SQUARE AND RECTANGULAR FLUE SIZES |
344 | FIGURE R1003.15.2 FLUE SIZES FOR MASONRY CHIMNEYS FIGURE R1003.18 CLEARANCE FROM COMBUSTIBLES |
345 | FIGURE R1003.20 CHIMNEY CRICKET TABLE R1003.20 CRICKET DIMENSIONS SECTION R1004 FACTORY-BUILT FIREPLACES SECTION R1005 FACTORY-BUILT CHIMNEYS |
346 | SECTION R1006 EXTERIOR AIR SUPPLY |
347 | PART IV — ENERGY CONSERVATION CHAPTER 11 ENERGY EFFICIENCY SECTION N1100 ADMINISTRATION |
349 | FIGURE N1100.4 CLIMATE ZONES |
362 | SECTION N1101 FENESTRATIONS (GLAZING) |
363 | SECTION N1102 WALLS |
364 | SECTION N1103 DOORS SECTION N1104 CEILINGS |
365 | FIGURE N1104.A.3 ACCEPTABLE ATTIC RADIANT BARRIER CONFIGURATIONS |
366 | SECTION N1105 FLOORS SECTION N1106 AIR INFILTRATION |
367 | TABLE N1106.ABC.1.1 ALLOWABLE AIR INFILTRATION RATES |
368 | SECTION N1107 SPACE COOLING SYSTEMS |
371 | TABLE N1107.ABC.3.2A ELECTRICALLY OPERATED UNITARY AIR CONDITIONERS AND CONDENSING UNITS |
372 | TABLE N1107.ABC.3.2B ELECTRICALLY OPERATED UNITARY AND APPLIED HEAT PUMPS – MINIMUM EFFICIENCY REQUIREMENTS |
373 | TABLE 1107.ABC.3.2D ELECTRICALLY OPERATED PACKAGED TERMINAL AIR CONDITIONERS, PACKAGED TERMINAL HEAT PUMPS, SINGLE-PACKAGE VERTICAL AIR CONDITIONERS, SINGLE-PACKAGE VERTICAL HEAT PUMPS, ROOM AIR CONDITIONERS, AND ROOM AIR CONDITIONERS HEAT PUMPS — MINIMUM EFFICIENCY REQUIREMENTS |
374 | TABLE 1107.ABC.3.2D – (CONTINUED) ELECTRICALLY OPERATED PACKAGED TERMINAL AIR CONDITIONERS, PACKAGED TERMINAL HEAT PUMPS, SINGLE-PACKAGE VERTICAL AIR CONDITIONERS, SINGLE-PACKAGE VERTICAL HEAT PUMPS, ROOM AIR CONDITIONERS, AND ROOM AIRCONDITIONERS HEAT PUMPS — MINIMUM EFFICIENCY REQUIREMENTS |
375 | SECTION N1108 SPACE HEATING SYSTEMS |
376 | TABLE N1108.ABC.3.2E WARM AIR FURNACES AND COMBINATION WARM AIR FURNACES/AIR-CONDITIONING UNITS,WARM AIR DUCT FURNACES AND UNIT HEATERS. MINIMUM EFFICIENCY REQUIREMENTS TABLE N1108.ABC.3.2F GAS- AND OIL-FIRED BOILERS MINIMUM EFFICIENCY REQUIREMENTS |
377 | SECTION N1109 VENTILATION SYSTEMS SECTION N1110 AIR DISTRIBUTION SYSTEMS |
378 | TABLE N1110.ABC.2.1 MINIMUM INSULATION LEVELS AIR DISTRIBUTION SYSTEM COMPONENTS1 |
383 | SECTION N1111 PIPING TABLE N1111.ABC.1 MINIMUM PIPE INSULATION |
384 | SECTION N1112 WATER HEATING SYSTEMS |
385 | TABLE N1112.ABC.3 MINIMUM PERFORMANCE STANDARDS WATER HEATING EQUIPMENT: FIRED STORAGE WATER HEATER MINIMUM ENERGY FACTORS (EF) |
386 | SECTION N1113 CALCULATIONAL PARAMETERS SPECIFIC TO COMPLIANCE METHOD A TABLE N1113.A.1-1 SPECIFICATIONS FOR BASELINE AND AS-BUILT HOMES |
387 | TABLE N1113.A.1-1 – (CONTINUED) SPECIFICATIONS FOR BASELINE AND AS-BUILT HOMES TABLE N1113.A.1-1 – (CONTINUED) SPECIFICATIONS FOR BASELINE AND AS-BUILT HOMES |
388 | TABLE N1113.A.1-1(A) DEFAULT BASELINE HOMEHEATING AND COOLING EQUIPMENT EFFICIENCIES (i),(k),(m),(n) |
389 | TABLE N1113.A.2-1 COEFFICIENTS A AND B |
391 | PART V — MECHANICAL CHAPTER 12 MECHANICAL ADMINISTRATION SECTION M1201 GENERAL [EB] SECTION M1202 EXISTING MECHANICAL SYSTEMS |
393 | CHAPTER 13 GENERAL MECHANICAL SYSTEM REQUIREMENTS SECTION M1301 GENERAL SECTION M1302 APPROVAL SECTION M1303 LABELING OF APPLIANCES SECTION M1304 TYPE OF FUEL SECTION M1305 APPLIANCE ACCESS |
394 | SECTION M1306 CLEARANCES FROM COMBUSTIBLE CONSTRUCTION |
395 | TABLE M1306.2 REDUCTION OF CLEARANCES WITH SPECIFIED FORMS OF PROTECTIONa, b, c, d, e, f, g, h, i, j, k |
396 | FIGURE M1306.1 REDUCED CLEARANCE DIAGRAM SECTION M1307 APPLIANCE INSTALLATION |
397 | FIGURE M1306.2 WALL PROTECTOR CLEARANCE REDUCTION SYSTEM SECTION M1308 MECHANICAL SYSTEMS INSTALLATION |
399 | CHAPTER 14 HEATING AND COOLING EQUIPMENT SECTION M1401 GENERAL SECTION M1402 CENTRAL FURNACES SECTION M1403 HEAT PUMP EQUIPMENT SECTION M1404 REFRIGERATION COOLING EQUIPMENT SECTION M1405 BASEBOARD CONVECTORS SECTION M1406 RADIANT HEATING SYSTEMS |
400 | SECTION M1407 DUCT HEATERS SECTION M1408 VENTED FLOOR FURNACES SECTION M1409 VENTED WALL FURNACES |
401 | SECTION M1410 VENTED ROOM HEATERS SECTION M1411 HEATING AND COOLING EQUIPMENT |
402 | SECTION M1412 ABSORPTION COOLING EQUIPMENT SECTION M1413 EVAPORATIVE COOLING EQUIPMENT SECTION 1414 FIREPLACE STOVES SECTION M1415 MASONRY HEATERS |
403 | CHAPTER 15 EXHAUST SYSTEMS SECTION M1501 GENERAL SECTION M1502 CLOTHES DRYER EXHAUST SECTION M1503 RANGE HOODS SECTION M1504 INSTALLATION OF MICROWAVE OVENS |
404 | SECTION M1505 OVERHEAD EXHAUST HOODS SECTION M1506 EXHAUST DUCTS SECTION M1507 MECHANICAL VENTILATION TABLE M1507.3 MINIMUM REQUIRED EXHAUST RATES FOR ONE- AND TWO-FAMILY DWELLINGS |
405 | CHAPTER 16 DUCT SYSTEMS SECTION M1601 DUCT CONSTRUCTION |
406 | TABLE M1601.5 GAGES OF METAL DUCTS AND PLENUMS USED FOR HEATING OR COOLING |
409 | SECTION M1602 RETURN AIR |
411 | CHAPTER 17 COMBUSTION AIR SECTION M1701 GENERAL SECTION M1702 ALL AIR FROM INSIDE THE BUILDING SECTION M1703 ALL AIR FROM OUTDOORS |
412 | FIGURE M1702.2 APPLIANCES LOCATED IN CONFINED SPACES—ALL AIR TAKEN FROM ADJACENT SPACES WITHIN THE BUILDING |
413 | FIGURE M1703.2(1) APPLIANCES LOCATED IN CONFINED SPACES—ALL AIR TAKEN FROM OUTDOORS THROUGH TWO OPENINGS FIGURE M1703.2(2) APPLIANCES LOCATED IN CONFINED SPACES—ALL AIR TAKEN FROM OUTDOORS THROUGH HORIZONTAL DUCTS |
414 | FIGURE M1703.2(3) APPLIANCES LOCATED IN CONFINED SPACES—ALL AIR TAKEN FROM OUTDOORS THROUGH VENTILATED ATTIC FIGURE M1703.2(4) APPLIANCES LOCATED IN CONFINED SPACES—INLET AIR TAKEN FROM VENTILATED CRAWL SPACE AND OUTLET AIR TO VENTILATED ATTIC |
415 | FIGURE M1703.3 APPLIANCES LOCATED IN CONFINED SPACES—ALL AIR TAKEN FROM OUTDOORS THROUGH VENTILATED ATTIC, INLET DUCT WITHIN OUTLET DUCT |
417 | CHAPTER 18 CHIMNEYS AND VENTS SECTION M1801 GENERAL SECTION M1802 VENT COMPONENTS |
418 | SECTION M1803 CHIMNEY AND VENT CONNECTORS TABLE M1803.2 THICKNESS FOR SINGLE-WALL METAL PIPE CONNECTORS TABLE M1803.3.4 CHIMNEY AND VENT CONNECTOR CLEARANCES TO COMBUSTIBLE MATERIALSa |
419 | SECTION M1804 VENTS TABLE M1804.1 VENT SELECTION CHART SECTION M1805 MASONRY AND FACTORY-BUILT CHIMNEYS |
421 | CHAPTER 19 SPECIAL FUEL-BURNING EQUIPMENT SECTION M1901 RANGES AND OVENS SECTION M1902 SAUNA HEATERS SECTION M1903 STATIONARY FUEL CELL POWER PLANTS SECTION M1904 GASEOUS HYDROGEN SYSTEMS |
423 | CHAPTER 20 BOILERS AND WATER HEATERS SECTION M2001 BOILERS SECTION M2002 OPERATING AND SAFETY CONTROLS SECTION M2003 EXPANSION TANKS SECTION M2004 WATER HEATERS USED FOR SPACE HEATING SECTION M2005 WATER HEATERS |
424 | TABLE M2003.2 EXPANSION TANK MINIMUM CAPACITYa FOR FORCED HOT-WATER SYSTEMS SECTION M2006 POOL HEATERS |
425 | CHAPTER 21 HYDRONIC PIPING SECTION M2101 HYDRONIC PIPING SYSTEMS INSTALLATION SECTION M2102 BASEBOARD CONVECTORS SECTION M2103 FLOOR HEATING SYSTEMS SECTION M2104 LOW TEMPERATURE PIPING |
426 | TABLE M2101.1 HYDRONIC PIPING MATERIALS |
427 | TABLE M2101.9 HANGER SPACING INTERNALS SECTION M2105 GROUND SOURCE HEAT PUMP SYSTEM LOOP PIPING |
429 | CHAPTER 22 SPECIAL PIPING AND STORAGE SYSTEMS SECTION M2201 OIL TANKS SECTION M2202 OIL PIPING, FITTING AND CONNECTIONS SECTION M2203 INSTALLATION |
430 | SECTION M2204 OIL PUMPS AND VALVES |
431 | CHAPTER 23 SOLAR SYSTEMS SECTION M2301 SOLAR ENERGY SYSTEMS |
433 | PART VI — FUEL GAS CHAPTER 24 FUEL GAS SECTION G2401 (101) GENERAL SECTION G2402 (201) GENERAL SECTION G2403 (202) GENERAL DEFINITIONS |
438 | SECTION G2404 (301) GENERAL |
439 | SECTION G2405 (302) STRUCTURAL SAFETY |
440 | SECTION G2406 (303) APPLIANCE LOCATION SECTION G2407 (304) COMBUSTION, VENTILATION AND DILUTION AIR ((EQUATION 24-1) (EQUATION 24-2) |
441 | FIGURE G2407.5.3 (304.5.3) ALL AIR FROM INSIDE THE BUILDING (see Section 2407.5.3) |
442 | FIGURE G2407.6.1(1) [304.6.1(1)] ALL AIR FROM OUTDOORS—INLET AIR FROM VENTILATED CRAWL SPACE AND OUTLET AIR TO VENTILATED ATTIC (SEE SECTION G2407.6.1) FIGURE G2407.6.1(2) [304.6.1(2)] ALL AIR FROM OUTDOORS THROUGH VENTILATED ATTIC (SEE SECTION G2407.6.1) |
443 | FIGURE G2407.6.1(3) [304.6.1(3)] ALL AIR FROM OUTDOORS (SEE SECTION G2407.6.1) FIGURE G2407.6.2 (304.6.2) SINGLE COMBUSTION AIR OPENING, ALL AIR FROM OUTDOORS (SEE SECTION 304.6.2) |
444 | SECTION G2408 (305) INSTALLATION SECTION G2409 (308) CLEARANCE REDUCTION |
445 | FIGURE G2409.2(1) [308.2(1)] EXTENT OF PROTECTION NECESSARY TO REDUCE CLEARANCES FROM GAS EQUIPMENT OR VENT CONNECTORS |
446 | FIGURE G2409.2(2) [308.2(2)] WALL PROTECTOR CLEARANCE REDUCTION SYSTEM SECTION G2410 (309) ELECTRICAL |
447 | TABLE G2409.2 (308.2) a THROUGH k REDUCTION OF CLEARANCES WITH SPECIFIED FORMS OF PROTECTION |
448 | FIGURE G2409.2(3) [308.2(3)] MASONRY CLEARANCE REDUCTION SYSTEM SECTION G2411 (310) ELECTRICAL BONDING SECTION G2412 (401) GENERAL SECTION G2413 (402) PIPE SIZING |
449 | TABLE G2413.2 (402.2) APPROXIMATE GAS INPUT FOR TYPICAL APPLIANCES (EQUATION 24-3) (EQUATION 24-4) TABLE G2413.4 (402.4) Cr AND Y VALUES FOR NATURAL GAS AND UNDILUTED PROPANE AT STANDARD CONDITIONS |
450 | TABLE G2413.4(1) [402.4(2)] SCHEDULE 40 METALLIC PIPE |
451 | TABLE G2413.4(2) [402.4(3)]SCHEDULE 40 METALLIC PIPE |
452 | TABLE G2413.4(3) [402.4(7)] SEMIRIGID COPPER TUBING |
453 | TABLE G2413.4(4) [402.4(10)] SEMIRIGID COPPER TUBING |
454 | TABLE G2413.4(5) [402.4(13)] CORRUGATED STAINLESS STEEL TUBING (CSST) |
455 | TABLE G2413.4(6) [402.4(16)] CORRUGATED STAINLESS STEEL TUBING (CSST) |
456 | TABLE G2413.4(7) [402.4(19)] POLYETHYLENE PLASTIC PIPE |
457 | TABLE G2413.4(8) [402.4(20)] POLYETHYLENE PLASTIC PIPE |
458 | SECTION G2414 (403) PIPING MATERIALS |
459 | TABLE G2414.9.2 (403.9.2) SPECIFICATIONS FOR THREADING METALLIC PIPE |
460 | SECTION G2415 (404) PIPING SYSTEM INSTALLATION |
461 | SECTION G2416 (405) PIPING BENDS AND CHANGES IN DIRECTION SECTION G2417 (406) INSPECTION, TESTING AND PURGING |
463 | SECTION G2418 (407) PIPING SUPPORT SECTION G2419 (408) DRIPS AND SLOPED PIPING SECTION G2420 (409) GAS SHUTOFF VALVES TABLE G2420.1.1 MANUAL GAS VALVE STANDARDS |
464 | SECTION G2421 (410) FLOW CONTROLS SECTION G2422 (411) APPLIANCE CONNECTIONS |
465 | SECTION G2423 (413) CNG GAS-DISPENSING SYSTEMS SECTION G2424 (415) PIPING SUPPORT INTERVALS TABLE G2424.1 SUPPORT OF PIPING SECTION G2425 (501) GENERAL |
466 | SECTION G2426 (502) VENTS |
467 | SECTION G2427 (503) VENTING OF EQUIPMENT |
468 | TABLE G2427.4 TYPE OF VENTING SYSTEM TO BE USED |
469 | FIGURE G2427.5.3 (503.5.4) TYPICAL TERMINATION LOCATIONS FOR CHIMNEYS AND SINGLE-WALL METAL PIPES |
471 | FIGURE G2427.6.3 (503.6.4) GAS VENT TERMINATION LOCATIONS FOR LISTED CAPS 12 INCHES OR LESS IN SIZE AT LEAST 8 FEET FROM A VERTICAL WALL |
472 | TABLE G2427.7.7 (503.8.7)a CLEARANCES FOR CONNECTORS |
474 | TABLE G2427.10.2.4 (503.10.2.4) MINIMUM THICKNESS FOR GALVANIZED STEEL VENT CONNECTORS FOR LOW-HEAT APPLIANCES |
476 | SECTION G2428 (504) SIZING OF CATEGORY I APPLIANCE VENTING SYSTEMS |
477 | TABLE G2428.2(1) [504.2(1)] TYPE B DOUBLE-WALL GAS VENT |
478 | TABLE G2428.2(1) [504.2(1)]—(CONTINUED) TYPE B DOUBLE-WALL GAS VENT |
479 | TABLE G2428.2(2) [504.2(2)] TYPE B DOUBLE-WALL GAS VENT |
480 | TABLE G2428.2(2) [504.2(2)—(CONTINUED) TYPE B DOUBLE-WALL GAS VENT |
482 | TABLE G2428.3(1) [504.3(1)] TYPE B DOUBLE-WALL VENT |
483 | TABLE G2428.3(2) [504.3(2)] TYPE B DOUBLE-WALL VENT |
484 | TABLE G2428.3(3) [504.3(3)] MASONRY CHIMNEY |
485 | TABLE G2428.3(4) [504.3(4)] MASONRY CHIMNEY |
486 | TABLE G2428.3.2 (504.3.2) MAXIMUM VENT CONNECTOR LENGTH |
488 | SECTION G2429 (505) DIRECT-VENT, INTEGRAL VENT, MECHANICAL VENT AND VENTILATION/EXHAUST HOOD VENTING SECTION G2430 (506) FACTORY-BUILT CHIMNEYS SECTION G2431 (601) GENERAL SECTION G2432 (602) DECORATIVE APPLIANCES FOR INSTALLATION IN FIREPLACES SECTION G2433 (603 ) LOG LIGHTERS SECTION G2434 (604) VENTED GAS FIREPLACES (DECORATIVE APPLIANCES) SECTION G2435 (605) VENTED GAS FIREPLACE HEATERS SECTION G2436 (608) VENTED WALL FURNACES |
489 | SECTION G2437 (609) FLOOR FURNACES SECTION G2438 (613) CLOTHES DRYERS SECTION G2439 (614) CLOTHES DRYER EXHAUST |
490 | SECTION G2440 (615) SAUNA HEATERS SECTION G2441 (617) POOL AND SPA HEATERS SECTION G2442 (618) FORCED-AIR WARM-AIR FURNACES |
491 | SECTION G2443 (619) CONVERSION BURNERS SECTION G2444 (620) UNIT HEATERS SECTION G2445 (621) UNVENTED ROOM HEATERS |
492 | SECTION G2446 (622) VENTED ROOM HEATERS SECTION G2447 (623) COOKING APPLIANCES SECTION G2448 (624) WATER HEATERS SECTION G2449 (627) AIR CONDITIONING EQUIPMENT SECTION G2450 (628) ILLUMINATING APPLIANCES |
493 | SECTION G2451 (630) INFRARED RADIANT HEATERS SECTION G2452 (631) BOILERS SECTION G2453 (634) CHIMNEY DAMPER OPENING AREA TABLE G2453.1 (634.1) FREE OPENING AREA OF CHIMNEY DAMPER FOR VENTING FLUE GASES FROM UNLISTED DECORATIVE APPLIANCES FOR INSTALLATION IN VENTED FIREPLACES |
495 | PART VII — PLUMBING CHAPTER 25 PLUMBING ADMINISTRATION SECTION P2501 GENERAL SECTION P2502 EXISTING PLUMBING SYSTEMS SECTION P2503 INSPECTION AND TESTS |
497 | CHAPTER 26 GENERAL PLUMBING REQUIREMENTS SECTION P2601 GENERAL SECTION P2602 INDIVIDUAL WATER SUPPLY AND SEWAGE DISPOSAL SECTION P2603 STRUCTURAL AND PIPING PROTECTION |
498 | SECTION P2604 TRENCHING AND BACKFILLING FIGURE P2604.4 PIPE LOCATION WITH RESPECT TO FOOTINGS SECTION P2605 SUPPORT SECTION P2606 WATERPROOFING OF OPENINGS SECTION P2607 WORKMANSHIP SECTION P2608 MATERIALS EVALUATION AND LISTING |
499 | TABLE P2605.1 PIPING SUPPORT TABLE P2608.4 PRODUCTS AND MATERIALS REQUIRING THIRD-PARTY TESTING AND THIRD-PARTY CERTIFICATION |
501 | CHAPTER 27 PLUMBING FIXTURES SECTION P2701 FIXTURES, FAUCETS AND FIXTURE FITTINGS SECTION P2702 FIXTURE ACCESSORIES SECTION P2703 TAIL PIECES SECTION P2704 ACCESS TO CONNECTIONS SECTION P2705 INSTALLATION SECTION P2706 WASTE RECEPTORS |
502 | TABLE P2701.1 PLUMBING FIXTURES, FAUCETS AND FIXTURE FITTINGS |
503 | SECTION P2707 DIRECTIONAL FITTINGS SECTION P2708 SHOWERS SECTION P2709 SHOWER RECEPTORS |
504 | SECTION P2710 SHOWER WALLS SECTION P2711 LAVATORIES SECTION P2712 WATER CLOSETS SECTION P2713 BATHTUBS |
505 | SECTION P2714 SINKS SECTION P2715 LAUNDRY TUBS SECTION P2716 FOOD WASTE GRINDER SECTION P2717 DISHWASHING MACHINES SECTION P2718 CLOTHES WASHING MACHINE SECTION P2719 FLOOR DRAINS SECTION P2720 WHIRLPOOL BATHTUBS SECTION P2721 BIDET INSTALLATIONS SECTION P2722 FIXTURE FITTING |
506 | SECTION P2723 MACERATING TOILET SYSTEMS SECTION P2724 SPECIALTY TEMPERATURE CONTROL DEVICES AND VALVES |
507 | CHAPTER 28 WATER HEATERS SECTION P2801 GENERAL SECTION P2802 WATER HEATERS USED FOR SPACE HEATING SECTION P2803 RELIEF VALVES |
509 | CHAPTER 29 WATER SUPPLY AND DISTRIBUTION SECTION P2901 GENERAL SECTION P2902 PROTECTION OF POTABLE WATER SUPPLY |
510 | TABLE P2902.3 APPLICATION FOR BACKFLOW PREVENTERS |
511 | TABLE P2902.3.1 MINIMUM AIR GAPS SECTION P2903 WATER-SUPPLY SYSTEM |
512 | TABLE P2903.1 REQUIRED CAPACITIES AT POINT OF OUTLET DISCHARGE TABLE P2903.2 MAXIMUM FLOW RATES AND CONSUMPTION FOR PLUMBING FIXTURES AND FIXTURE FITTINGSb TABLE P2903.2b MINIMUM WATER SERVICE SIZEa |
513 | TABLE P2903.6 WATER-SUPPLY FIXTURE-UNIT VALUES FOR VARIOUS PLUMBING FIXTURES AND FIXTURE GROUPS |
514 | TABLE P2903.6(1) CONVERSIONS FROM WATER SUPPLY FIXTURE UNIT TO GALLON PER MINUTE FLOW RATES |
515 | TABLE P2903.7 MINIMUM SIZE OF WATER METERS, MAINS AND DISTRIBUTION PIPING BASED ON WATER SUPPLY FIXTURE UNIT VALUES |
516 | TABLE P2903.7—(CONTINUED) MINIMUM SIZE OF WATER METERS, MAINS AND DISTRIBUTION PIPING BASED ON WATER SUPPLY FIXTURE UNIT VALUES TABLE P2903.8.1 MANIFOLD SIZING |
517 | FIGURE P2903.10 TYPICAL FROSTPROOF HOSE BIBB INSTALLATION NOT REQUIRING SEPARATE VALUE |
518 | SECTION P2904 MATERIALS, JOINTS AND CONNECTIONS TABLE P2904.4 WATER SERVICE PIPE |
519 | TABLE P2904.5 WATER DISTRIBUTION PIPE TABLE P2904.6 PIPE FITTINGS |
521 | SECTION P2905 CHANGES IN DIRECTION SECTION P2906 SUPPORT SECTION P2907 DRINKING WATER TREATMENT UNITS |
523 | CHAPTER 30 SANITARY DRAINAGE SECTION P3001GENERAL SECTION P3002 MATERIALS SECTION P3003 JOINTS AND CONNECTIONS |
524 | TABLE P3002.1(1) ABOVE-GROUND DRAINAGE AND VENT PIPE TABLE P3002.1(2) UNDERGROUND BUILDING DRAINAGE AND VENT PIPE |
525 | TABLE P3002.2 BUILDING SEWER PIPE TABLE P3002.3 PIPE FITTINGS |
528 | SECTION P3004 DETERMINING DRAINAGE FIXTURE UNITS TABLE P3004.1 DRAINAGE FIXTURE UNIT (d.f.u.) VALUES FOR VARIOUS PLUMBING FIXTURES SECTION P3005 DRAINAGE SYSTEM |
529 | TABLE P3005.1 FITTINGS FOR CHANGE IN DIRECTION |
530 | TABLE P3005.4.1 MAXIMUM FIXTURE UNITS ALLOWED TO BE CONNECTED TO BRANCHES AND STACKS TABLE P3005.4.2 MAXIMUM NUMBER OF FIXTURE UNITS ALLOWED TO BE CONNECTED TO THE BUILDING DRAIN, BUILDING DRAIN BRANCHES OR THE BUILDING SEWER |
531 | SECTION P3006 SIZING OF DRAIN PIPE OFFSETS SECTION P3007 SUMPS AND EJECTORS SECTION P3008 BACKWATER VALVES |
533 | CHAPTER 31 VENTS SECTION P3101 VENT SYSTEMS SECTION P3102 VENT STACKS AND STACK VENTS SECTION P3103 VENT TERMINALS SECTION P3104 VENT CONNECTIONS AND GRADES |
534 | SECTION P3105 FIXTURE VENTS TABLE P3105.1 MAXIMUM DISTANCE OF FIXTURE TRAP FROM VENT SECTION P3106 INDIVIDUAL VENT SECTION P3107 COMMON VENT TABLE P3107.3 COMMON VENT SIZES SECTION P3108 WET VENTING |
535 | TABLE P3108.3 WET VENT SIZE SECTION P3109 WASTE STACK VENT TABLE P3109.4 WASTE STACK VENT SIZE SECTION P3110 CIRCUIT VENTING SECTION P3111 COMBINATION WASTE AND VENT SYSTEM |
536 | TABLE P3111.3 SIZE OF COMBINATION WASTE AND VENT PIPE SECTION P3112 ISLAND FIXTURE VENTING SECTION P3113 VENT PIPE SIZING SECTION P3114 AIR ADMITTANCE VALVES |
537 | TABLE P3113.4.1 SIZE AND LENGTH OF SUMP VENTS |
539 | CHAPTER 32 TRAPS SECTION P3201 FIXTURE TRAPS TABLE P3201.7 SIZE OF TRAPS AND TRAP ARMS FOR PLUMBING FIXTURES |
541 | PART VIII — ELECTRICAL CHAPTER 33 GENERAL REQUIREMENTS SECTION E3301 GENERAL SECTION E3302 BONDING METAL FRAMING MEMBERS SECTION E3303 CROSS REFERENCES TABLE E3303 CROSS REFERENCES DEFINING ELECTRICAL REQUIREMENTS OF THE FLORIDA BUILDING CODE SECTIONS E3304 THROUGH E3307 RESERVED |
542 | TABLE E3303—(CONTINUED) FLORIDA BUILDING CODE—BUILDING |
543 | TABLE E3303—(CONTINUED) FLORIDA BUILDING CODE — RESIDENTIAL |
544 | TABLE E3303—(CONTINUED) FLORIDA BUILDING CODE — MECHANICAL |
545 | CHAPTER 34 ELECTRICAL DEFINITIONS RESERVED |
547 | CHAPTER 35 SERVICES RESERVED |
549 | CHAPTER 36 BRANCH CIRCUIT AND FEEDER REQUIREMENT SRESERVED |
551 | CHAPTER 37 WIRING METHODS RESERVED |
553 | CHAPTER 38 POWER AND LIGHTING DISTRIBUTION RESERVED |
555 | CHAPTER 39 DEVICES AND LUMINAIRES RESERVED |
557 | CHAPTER 40 APPLIANCE INSTALLATIONRESERVED |
559 | CHAPTER 41 SWIMMING POOLS SECTION R4101 PRIVATE SWIMMING POOLS |
565 | SECTIONS E4102 THROUGH E4109 RESERVED |
567 | CHAPTER 42 CLASS 2 REMOTE-CONTROL, SIGNALING AND POWER-LIMITED CIRCUITS RESERVED |
569 | PART IX—REFERENCED STANDARDS CHAPTER 43 REFERENCED STANDARDS AA AAF AAMA |
570 | ACCA ACI ADC AFPA |
571 | AHA AHAM AISC AISI |
572 | AITC ANSI |
573 | APA |
574 | ARDM ARI ASCE ASHRAE |
575 | ASME |
576 | ASSE ASTM |
585 | AWS |
586 | AWPA AWWA |
587 | CGSB CISPI CPSC CRRC CSA |
589 | CSSB DASMA DOC/NIST DOE |
590 | DOL/OSHA DOTn FCPA FEMA FLORIDA CODES |
592 | FM FRSA FS FSEC FTC |
593 | FWC GA GAMA HI HPVA HUD |
594 | ICC ISO MSS NAAMM NAIMA NCMA |
595 | NFPA NFRC NRCA NSF NSPI |
596 | RMI/SMA RCSC SAE SDI SDI |
597 | SJI SMACNA SSPC SPRI SRCC STI |
598 | TECO TMS TPI UL |
599 | ULC WDMA WPPC |
600 | WQA |
601 | CHAPTER 44 HIGH-VELOCITY HURRICANE ZONES SECTION R4401 HIGH-VELOCITY HURRICANE ZONES — EXTERIOR WALL COVERING SECTION R4402 HIGH-VELOCITY HURRICANE ZONES — ROOF ASSEMBLIES AND ROOFTOP STRUCTURES |
602 | SECTION R4402.2 HIGH-VELOCITY HURRICANE ZONES —DEFINITIONS |
604 | SECTION R4402.3 HIGH-VELOCITY HURRICANE ZONES — WEATHER PROTECTION |
605 | SECTION R4402.4 HIGH-VELOCITY HURRICANE ZONES —PERFORMANCE REQUIREMENTS |
606 | TABLE R4402.4.2 MINIMUM SLOPE SECTION R4402.5 HIGH-VELOCITY HURRICANE ZONES — FIRE CLASSIFICATION SECTION R4402.6 HIGH-VELOCITY HURRICANE ZONES —MATERIALS |
607 | SECTION R4402.7 HIGH-VELOCITY HURRICANE ZONES — ROOF COVERINGS WITH SLOPES 2:12 OR GREATER |
610 | SECTION R4402.8 HIGH-VELOCITY HURRICANE ZONES — ROOF COVERINGS WITH SLOPES LESS THAN 2:12 TABLE R4402.8.3A SLOPE AND APPLICATION TEMPERATURE CRITERIA TABLE R4402.8.3B SLOPE AND APPLICATION TEMPERATURE CRITERIA |
612 | SECTION R4402.9 HIGH-VELOCITY HURRICANE ZONES —ROOF INSULATION |
613 | SECTION R4402.10 HIGH-VELOCITY HURRICANE ZONES —REROOFING |
614 | SECTION R4402.11 HIGH-VELOCITY HURRICANE ZONES — ROOFTOP STRUCTURES AND COMPONENTS |
615 | TABLE R4402.11.3 ROOF MOUNTED EQUIPMENT HEIGHT REQUIREMENTS SECTION R4402.12 HIGH-VELOCITY HURRICANE ZONES — TESTING |
618 | SECTION R4402.13 HIGH-VELOCITY HURRICANE ZONES —REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS |
620 | SECTION R4402.14 HIGH-VELOCITY HURRICANE ZONES — UNIFORM PERMIT APPLICATION |
625 | SECTION R4403 HIGH-VELOCITY HURRICANE ZONES—GENERAL SECTION R4403.2 HIGH-VELOCITY HURRICANE ZONES—DEFLECTION SECTION R4403.3 HIGH-VELOCITY HURRICANE ZONES—VOLUME CHANGES SECTION R4403.4 HIGH-VELOCITY HURRICANE ZONES—MINIMUM LOADS |
626 | SECTION R4403.5 HIGH-VELOCITY HURRICANE ZONES —ROOF LIVE LOADS SECTION R4403.6 HIGH-VELOCITY HURRICANE ZONES —ROOF DRAINAGE FIGURE R4403.6.3 REQUIRED AREA OF OVERFLOW SCUPPERS SECTION R4403.7 HIGH-VELOCITY HURRICANE ZONES —SPECIAL LOAD CONSIDERATIONS |
628 | SECTION R4403.8 HIGH-VELOCITY HURRICANE ZONES — LIVE LOAD REDUCTIONS SECTION R4403.9 HIGH-VELOCITY HURRICANE ZONES —WIND LOADS SECTION R4403.10 HIGH VELOCITY HURRICANE ZONES —OVERTURNING MOMENT AND UPLIFT SECTION R4403.11 RESERVED SECTION R4403.12 HIGH-VELOCITY HURRICANE ZONES — SCREEN ENCLOSURES |
629 | SECTION R4403.13 RESERVED SECTION R4403.14 HIGH-VELOCITY HURRICANE ZONES—FOUNDATION DESIGN SECTION R4403.15 HIGH-VELOCITY HURRICANE ZONES—LOAD TESTS TABLE R4403.15.4 FATIGUE LOADING SEQUENCE SECTION R4403.16 HIGH-VELOCITY HURRICANE ZONES— IMPACT TESTS FOR WIND-BORNE DEBRIS |
632 | TABLE R4403.16 CYCLIC WIND PRESSURE LOADING SECTION R4404 HIGH-VELOCITY HURRICANE ZONES —FOUNDATIONS AND RETAINING WALLS SECTION R4404.2 HIGH-VELOCITY HURRICANE ZONES — BEARING CAPACITY OF SOIL SECTION R4404.3 HIGH-VELOCITY HURRICANE ZONES—SOIL BEARING FOUNDATIONS |
634 | TABLE R4404.3.6 ALLOWABLE LATERAL PRESSURE SECTION R4404.4 HIGH-VELOCITY HURRICANE ZONES CONCRETE SLABS ON FILL |
635 | SECTION R4404.5 HIGH-VELOCITY HURRICANE ZONES —MONOLITHIC FOOTINGS |
636 | SECTION R4404.6 HIGH-VELOCITY HURRICANE ZONES—PILE FOUNDATIONS |
638 | SECTION R4404.7 HIGH-VELOCITY HURRICANE ZONES WOOD PILES TABLE R4404.7 SECTION R4404.8 HIGH-VELOCITY HURRICANE ZONES —PRECAST CONCRETE PILES |
639 | TABLE R4404.8 SECTION R4404.9 HIGH-VELOCITY HURRICANE ZONES—PRESTRESSED PRECAST CONCRETE PILES SECTION R4404.10 HIGH-VELOCITY HURRICANE ZONES—CAST-IN-PLACE SECTION R4404.11 HIGH-VELOCITY HURRICANE ZONES—ROLLED STRUCTURAL SHAPES |
640 | SECTION R4404.12 HIGH-VELOCITY HURRICANE ZONES— SPECIAL PILES OR SPECIAL CONDITIONS SECTION R4404.13 HIGH-VELOCITY HURRICANE ZONES— LOAD TESTS ON PILES SECTION R4404.14 HIGH-VELOCITY HURRICANE ZONES—FOUNDATION WALLS AND GRADE BEAMS |
641 | SECTION R4404.15 HIGH-VELOCITY HURRICANE ZONES — GRADES UNDER BUILDINGS SECTION R4404.16 HIGH-VELOCITY HURRICANE ZONES —RETAINING WALLS SECTION R4404.17 HIGH-VELOCITY HURRICANE ZONES —SEAWALLS AND BULKHEADS SECTION R4404.18 HIGH-VELOCITY HURRICANE ZONES —SOIL IMPROVEMENT |
642 | SECTION R4405 HIGH-VELOCITY HURRICANE ZONES —CONCRETE SECTION R4405.2 HIGH-VELOCITY HURRICANE ZONES —STANDARDS SECTION R4405.3 HIGH-VELOCITY HURRICANE ZONES —DEFINITIONS SECTION R4405.4 HIGH-VELOCITY HURRICANE ZONES –MATERIALS |
644 | SECTION R4405.5 HIGH VELOCITY HURRICANE ZONES —CONCRETE QUALITY |
645 | SECTION R4405.6 HIGH-VELOCITY HURRICANE ZONES —MIXING AND PLACING CONCRETE |
646 | SECTION R4405.7 HIGH-VELOCITY HURRICANE ZONES —FORMWORK, EMBEDDED PIPES AND CONSTRUCTION JOINTS |
647 | SECTION R4405.8 HIGH-VELOCITY HURRICANE ZONES —DETAILS OF REINFORCEMENT |
649 | SECTION R4405.9 HIGH-VELOCITY HURRICANE ZONES —PRECAST CONCRETE UNITS |
650 | SECTION R4405.10 HIGH-VELOCITY HURRICANE ZONES —PRESTRESSED CONCRETE |
652 | SECTION R4405.11 HIGH-VELOCITY HURRICANE ZONES —PNEUMATICALLY PLACED CONCRETE (SHOTCRETE) |
653 | SECTION R4405.12 HIGH-VELOCITY HURRICANE ZONES —LIGHTWEIGHT INSULATING CONCRETE FILL |
654 | SECTION 4406 HIGH-VELOCITY HURRICANE ZONE SLIGHT METAL ALLOYS |
656 | SECTION 4407 HIGH-VELOCITY HURRICANE ZONES —MASONRY SECTION R4407.2 HIGH-VELOCITY HURRICANE ZONES —QUALITY, TESTS, AND APPROVALS |
658 | MORTAR STRENGTH PROPERTY SPECIFICATIONS TABLE TYPE OF MORTAR BASED ON LOCATION TABLE MASONRY WALLS LIMIT OF GROSS AREA TABLE SECTION R4407.3 HIGH-VELOCITY HURRICANE ZONES —ALLOWABLE UNIT STRESSES IN UNIT MASONRY SECTION R4407.4 HIGH-VELOCITY HURRICANE ZONES CONSTRUCTION DETAILS |
663 | SECTION R4407.5 HIGH-VELOCITY HURRICANE ZONES —REINFORCED UNIT MASONRY |
664 | SECTION R4408 HIGH-VELOCITY HURRICANE ZONES — STEEL |
665 | SECTION R4408.2 HIGH-VELOCITY HURRICANE ZONES — MATERIAL |
666 | SECTION R4408.3 HIGH-VELOCITY HURRICANE ZONES — DESIGN LOADS SECTION R4408.4 HIGH-VELOCITY HURRICANE ZONES — MINIMUM THICKNESS OF MATERIAL SECTION R4408.5 HIGH-VELOCITY HURRICANE ZONES —CONNECTIONS SECTION R4408.6 HIGH-VELOCITY HURRICANE ZONES — TUBULAR COLUMNS SECTION R4408.7 HIGH-VELOCITY HURRICANE ZONES —PROTECTION OF METAL SECTION R4408.8 HIGH-VELOCITY HURRICANE ZONES — OPEN WEB STEEL JOISTS |
668 | SECTION R4408.9 HIGH VELOCITY HURRICANE ZONES — COLD-FORMED STEEL CONSTRUCTION |
669 | SECTION R4408.10 HIGH-VELOCITY HURRICANE ZONES —PREENGINEERED, PREFABRICATED METAL BUILDING SYSTEMS AND COMPONENTS (PREENGINEERED STRUCTURES) |
670 | SECTION R4408.11 HIGH-VELOCITY HURRICANE ZONES —CHAIN LINK FENCES |
671 | TABLE R4408.11 CHAIN LINK FENCE MINIMUM REQUIREMENTS SECTION R4409 HIGH-VELOCITY HURRICANE ZONES—WOOD |
673 | SECTION R4409.2 HIGH-VELOCITY HURRICANE ZONES—QUALITY |
674 | TABLE R4409.2.4.2 MINIMUM GRADE REQUIREMENTS: BOARD GRADES SECTION R4409.3 RESERVED SECTION R4409.4 HIGH-VELOCITY HURRICANE ZONES—UNIT STRESSES SECTION R4409.5 HIGH-VELOCITY HURRICANE ZONES—VERTICAL FRAMING |
676 | SECTION R4409.6 HIGH-VELOCITY HURRICANE ZONES —HORIZONTAL FRAMING |
681 | SECTION R4409.7 HIGH-VELOCITY HURRICANE ZONES —FIRESTOPS |
682 | SECTION R4409.8 HIGH-VELOCITY HURRICANE ZONES —ANCHORAGE SECTION R4409.9 HIGH-VELOCITY HURRICANE ZONES —SHEATHING |
683 | TABLE R4409.9.1.6 PLYWOOD SUBFLOOR1 TABLE R4409.9.1.13 ALLOWABLE SPAN FOR PLYWOOD COMBINATION SUBFLOOR UNDERLAYMENT1 (SINGLE FLOOR PANELS) |
684 | TABLE R4409.9.2.3 ALLOWABLE SPAN FOR PLYWOOD ROOF SHEATHING1 |
685 | SECTION R4409.10 HIGH-VELOCITY HURRICANE ZONES — FURRING SECTION R4409.11 HIGH-VELOCITY HURRICANE ZONES —CONNECTORS SECTION R4409.12 HIGH-VELOCITY HURRICANE ZONES —WOOD SUPPORTING MASONRY SECTION R4409.13 HIGH-VELOCITY HURRICANE ZONES —PROTECTION OF WOOD |
687 | TABLE R4409.13.1 NAIL CONNECTION FOR WOOD MEMBERS |
688 | SECTION R4409.14 HIGH-VELOCITY HURRICANE ZONES —FIRE-RETARDANT WOOD SECTION R4409.15 HIGH-VELOCITY HURRICANE ZONES —WOOD FENCES SECTION R4409.16 HIGH-VELOCITY HURRICANE ZONES —FIRE-RETARDANT-TREATED SHAKES AND SHINGLES |
689 | SECTION R4409.17 HIGH-VELOCITY HURRICANE ZONES —WOOD BLOCKING SECTION R4410 HIGH-VELOCITY HURRICANE ZONES —GLASS AND GLAZING SECTION R4410.2 HIGH-VELOCITY HURRICANE ZONES —WINDOWS, DOORS, GLASS AND GLAZING |
693 | SECTION R4410.3 HIGH-VELOCITY HURRICANE ZONES —GLASS VENEER |
694 | SECTION R4410.4 HIGH-VELOCITY HURRICANE ZONES–STORM SHUTTERS/EXTERNAL PROTECTIVE DEVICES SECTION R4410.5 HIGH-VELOCITY HURRICANE ZONES —CURTAIN WALLS |
695 | SECTION R4410.6 HIGH-VELOCITY HURRICANE ZONES —STRUCTURAL GLAZING SYSTEMS |
696 | SECTION R4411 HIGH-VELOCITY HURRICANE ZONES —GYPSUM BOARD AND PLASTER |
697 | TABLE R4411.1.3.2 WEIGHTS OF METAL AND WIRE LATH* TABLE R4411.1.5.2 SPANS AND SPACING OF MAIN RUNNERS TABLE R4411.1.5.3 SIZES OF CROSS FURRING IN SUSPENDED AND FURRED CEILINGS |
698 | TABLE R4411.1.5.4 HANGERS SUPPORTING SUSPENDED CEILINGS SECTION R4411.2 HIGH VELOCITY HURRICANE ZONES–PLASTER TABLE R4411.2.1.5 REQUIRED THICKNESS OF INTERIOR PLASTER |
699 | TABLE R4411.2.3.1.1 GYPSUM AND HARDWALL PLASTER |
700 | SECTION R4411.3 HIGH-VELOCITY HURRICANE ZONES — STUCCO |
701 | SECTION R4411.4 HIGH-VELOCITY HURRICANE ZONES — GYPSUM BOARD PRODUCTS AND ACCESSORY ITEMS |
702 | SECTION R4411.5 HIGH-VELOCITY HURRICANE ZONES —SUSPENDED AND FURRED CEILINGS SECTION R4411.6 HIGH-VELOCITY HURRICANE ZONES —ASBESTOS SECTION R4411.7 HIGH-VELOCITY HURRICANE ZONES — TILE SECTION R4412 HIGH-VELOCITY HURRICANE ZONES — PLASTICS |
705 | TABLE R4412.1.4.4.4 AREA LIMITATIONS FOR ROOF PANELS |
706 | TABLE R4412.1.4.3.1.3 AREA LIMITATION AND SEPARATION REQUIREMENTS FOR PLASTIC WALL PANELS IN NONFIRE-RATED WALLS |
707 | SECTION R4413 HIGH-VELOCITY HURRICANE ZONES —STORM DRAINAGE TABLE R4413.1.6 FITTINGS FOR CHANGE IN DIRECTION SECTION R4413.2 HIGH VELOCITY HURRICANE ZONES —MATERIALS |
708 | TABLE R4413.2.2 ABOVE-GROUND DRAINAGE AND VENT PIPE TABLE R4413.2.3 UNDERGROUND BUILDING DRAINAGE AND VENT PIPE TABLE R4413.2.4 BUILDING STORM SEWER PIPE TABLE R4413.2.5 SUBSOIL DRAIN PIPE |
709 | TABLE R4413.2.7 PIPE FITTINGS SECTION R4413.3 RESERVED SECTION R4413.4 HIGH-VELOCITY HURRICANE ZONES—CONDUCTORS AND CONNECTIONS SECTION R4413.5 HIGH-VELOCITY HURRICANE ZONES–ROOF DRAINS SECTION R4413.6 HIGH VELOCITY HURRICANE ZONES–SIZE OF CONDUCTORS, LEADERS AND STORM DRAINS SECTION R4413.7 HIGH-VELOCITY HURRICANE ZONES–SECONDARY (EMERGENCY) ROOF DRAINS |
710 | FIGURE R4413.6.1 100-YEAR, 1-HOUR RAINFALL (inches) EASTERN UNITED STATES |
711 | TABLE R4413.6.2 SIZE OF VERTICAL CONDUCTORS AND LEADERS TABLE R4413.6.3 SIZE OF HORIZONTAL STORM DRAINAGE PIPING |
712 | TABLE R4416.6.6 SIZE OF SEMICIRCULAR ROOF GUTTERS |
713 | TABLE R4413.7 SIZING SCUPPERS FOR A 5 INCHES PER HOUR RATE OF RAINFALL |
715 | APPENDIX A (IFGS) SIZING AND CAPACITIES OF GAS PIPING |
716 | TABLE A.2.2 EQUIVALENT LENGTHS OF PIPE FITTINGS AND VALVES |
717 | TABLE A.2.2—(CONTINUED) EQUIVALENT LENGTHS OF PIPE FITTINGS AND VALVES |
718 | TABLE A.2.4 MULTIPLIERS TO BE USED WITH TABLES G2413.4(1) THROUGH G2413.4(8) WHERE THE SPECIFIC GRAVITY OF THE GAS IS OTHER THAN 0.60 |
720 | TABLE A.3.4 THOUSANDS OF Btu/h (MBH) OF NATURAL GAS PER 100 FEET OF PIPE AT VARIOUS PRESSURE DROPS AND PIPE DIAMETERS |
721 | TABLE A.5.1 SCHEDULE 40 STEEL PIPE STANDARD SIZES TABLE A.5.2 COPPER TUBE STANDARD SIZES |
722 | FIGURE A.6(a) CAPACITY OF NATURAL GAS PIPING, LOW PRESSURE (0.60 WC) |
723 | FIGURE A.6 (b) CAPACITY OF NATURAL GAS PIPING, HIGH PRESSURE (1.5 PSI AND ABOVE) FIGURE A.7.1 PIPING PLAN SHOWING A STEEL PIPING SYSTEM |
724 | FIGURE A.7.2 PIPING PLAN SHOWING A CSST SYSTEM FIGURE A.7.3 PIPING PLAN SHOWING A COPPER TUBING SYSTEM |
725 | FIGURE A.7.4 PIPING PLAN SHOWING A MODIFICATION TO EXISTING PIPING SYSTEM |
727 | APPENDIX B (IFGS) SIZING OF VENTING SYSTEMS SERVING APPLIANCES EQUIPPED WITH DRAFT HOODS, CATEGORY I APPLIANCES, AND APPLIANCES LISTED FOR USE WITH TYPE B VENTS EXAMPLES USING SINGLE APPLIANCE VENTING TABLES FIGURE B-1 TYPE B DOUBLE-WALL VENT SYSTEM SERVING A SINGLE APPLIANCE WITH A TYPE B DOUBLE-WALL VENT FIGURE B-2 TYPE B DOUBLE-WALL VENT SYSTEM SERVING A SINGLE APPLIANCE WITH A SINGLE-WALL METAL VENT CONNECTOR |
728 | FIGURE B-3 VENT SYSTEM SERVING A SINGLE APPLIANCE WITH A MASONRY CHIMNEY OF TYPE B FIGURE B-4 VENT SYSTEM SERVING A SINGLE APPLIANCE USING A MASONRY CHIMNEY AND A SINGLE-WALL METAL VENT CONNECTOR FIGURE B-5 ASBESTOS CEMENT TYPE B OR SINGLE-WALL METAL VENT SYSTEM SERVING A SINGLE FIGURE B-6 VENT SYSTEM SERVING TWO OR MORE APPLIANCES WITH TYPE B DOUBLE-WALL VENT AND TYPE B DOUBLE-WALL VENT CONNECTOR |
729 | FIGURE B-7 VENT SYSTEM SERVING TWO OR MORE APPLIANCES WITH TYPE B DOUBLE-WALL VENT AND SINGLE-WALL METAL VENT CONNECTORS FIGURE B-8 MASONRY CHIMNEY SERVING TWO OR MORE APPLIANCES WITH TYPE B DOUBLE-WALL VENT CONNECTOR FIGURE B-9 MASONRY CHIMNEY SERVING TWO OR MORE APPLIANCES WITH SINGLE-WALL METAL VENT CONNECTORS FIGURE B-10 ASBESTOS CEMENT TYPE B OR SINGLE-WALL METAL VENT SYSTEM SERVING TWO OR MORE DRAFT-HOOD-EQUIPPED APPLIANCES |
730 | FIGURE B-11 USE OF MANIFOLD COMMON VENT CONNECTOR FIGURE B-12 USE OF OFFSET COMMON VENT FIGURE B-13 MULTISTORY GAS VENT DESIGN PROCEDURE FOR EACH SEGMENT OF SYSTEM FIGURE B-14 MULTISTORY VENT SYSTEMS |
731 | FIGURE B-15 (EXAMPLE 1) SINGLE DRAFT-HOOD-EQUIPPED APPLIANCE FIGURE B-16 (EXAMPLE 2) SINGLE FAN-ASSISTED APPLIANCE |
732 | EXAMPLES USING COMMON VENTING TABLES FIGURE B-17 (EXAMPLE 4) COMMON VENTING TWO DRAFT HOOD-EQUIPPED APPLIANCES FIGURE B-18 (EXAMPLE 5A) COMMON VENTING A DRAFT HOOD WITH A FAN-ASSISTED FURNACE INTO A TYPE B DOUBLE-WALL COMMON VENT |
734 | TABLE B-1 MASONRY CHIMNEY LINER DIMENSIONS WITH CIRCULAR EQUIVALENTSa |
735 | FIGURE B-19 |
737 | APPENDIX C (IFGS) EXIT TERMINALS OF MECHANICAL DRAFT AND DIRECT-VENT VENTING SYSTEMS APPENDIX C EXIT TERMINALS OF MECHANICAL DRAFT AND DIRECT-VENT VENTING SYSTEMS |
739 | APPENDIX D (IFGS) RECOMMENDED PROCEDURE FOR SAFETY INSPECTION OF AN EXISTING APPLIANCE INSTALLATION RESERVED |
741 | APPENDIX E CHAPTER 9B-53 FLORIDA STANDARD FOR MITIGATION OF RADON IN EXISTING BUILDINGS |
742 | INTRODUCTION PRINCIPAL APPROACHES FOR RADON MITIGATION IN EXISTING BUILDINGS FOREWORD |
743 | CHAPTER E1 ADMINISTRATION CHAPTER E2 DEFINITIONS |
744 | CHAPTER E3 TESTING CHAPTER E4 STRUCTURAL SEALING AND HVAC SYSTEM BALANCING |
745 | CHAPTER E5 ENGINEERED SYSTEMS |
746 | CHAPTER E6 SOIL DEPRESSURIZATION SYSTEMS |
749 | APPENDIX F CHAPTER 9B-52 FLORIDA STANDARD FOR PASSIVE RADON-RESISTANT NEW RESIDENTIAL BUILDING CONSTRUCTION |
750 | CHAPTER F1 GENERAL CHAPTER F2 DEFINITIONS |
751 | CHAPTER F3 CONSTRUCTION REQUIREMENTS FOR PASSIVE RADON CONTROL |
757 | APPENDIX G SUPPLEMENTAL INFORMATION FOR CHAPTER 11 SUBAPPENDIX G-A JURISDICTIONAL DATA |
769 | SUBAPPENDIX G-B GENERAL REQUIREMENTS FOR CHAPTER 11 TABLE B1.2.2 R-VALUES OF COMPRESSED INSULATION TABLE B1.2.3 INSULATION INSTALLATION STANDARDS |
770 | TABLE B2.1.1 DEFAULT WINDOW ENERGY VALUES |
772 | TABLE B4.1.1A COOLING SYSTEM TO BE ASSUMED, MINIMUM RATINGS BY DATE PERMITTED AIR CONDITIONERS TABLE B4.1.1B HEATING SYSTEM ASSUMED, MINIMUM RATINGS BY DATE PERMITTED HEAT PUMPS |
773 | SUBAPPENDIX G-C SUPPLEMENTAL CRITERIA FOR THE ALTERNATE RESIDENTIAL POINTS SYSTEM METHOD EQUATION C1.2 INTERPOLATION FROM TABLES EQUATION C2.1.2A EQUATION C2.1.2B EQUATION C2.1.2D |
774 | TABLE C2.1.1.A SUBSTITUTE GLASS POINT MULTIPLIERS BY GLASS SOLAR HEAT GAIN COEFFICIENT AND ORIENTATION FOR CLIMATE ZONES 1, 2, 3 |
775 | TABLE C2.1.1A (CONTINUED) SUBSTITUTE GLASS POINT MULTIPLIERS BY GLASS SOLAR HEAT GAIN COEFFICIENT AND ORIENTATION FOR CLIMATE ZONES 1,2,3 |
776 | TABLE C2.1.1B SUBSTITUTE GLASS POINT MULTIPLIERS BY GLASS SOLAR HEAT GAIN COEFFICIENT AND ORIENTATION FOR CLIMATE ZONES 4,5,6 |
777 | TABLE C2.1.1B (CONTINUED) SUBSTITUTE GLASS POINT MULTIPLIERS BY GLASS SOLAR HEAT GAIN COEFFICIENT AND ORIENTATION FOR CLIMATE ZONES 4,5,6 |
778 | TABLE C2.1.1C SUBSTITUTE GLASS POINT MULTIPLIERS BY GLASS SOLAR HEAT GAIN COEFFICIENT AND ORIENTATION FOR CLIMATE ZONES 7,8,9 |
779 | TABLE C2.1.1C (CONTINUED) SUBSTITUTE GLASS POINT MULTIPLIERS BY GLASS SOLAR HEAT GAIN COEFFICIENT AND ORIENTATION FOR CLIMATE ZONES 7,8,9 |
780 | EQUATION C2.1.2E EQUATION C2.1.2F EQUATION C2.1.2G EQUATION C2.1.2H FIGURE C2.1.5 |
781 | TABLE C2.2.1 CONCRETE BLOCK MULTIPLIERS – LIGHT WEIGHT TABLE C2.2.2 CONCRETE BLOCK MULTIPLIERS POLYSTYRENE BEAD AGGREGATE TABLE C2.4.1 CEILING UNDER ATTIC SUMMER AND WINTER POINT MULTIPLIERS |
782 | TABLE C2.4.2 CEILING SINGLE ASSEMBLY SUMMER AND WINTER POINT MULTIPLIERS TABLE C2.4.3 CONCRETE DECK ROOF: EXPOSED SUMMER AND WINTER POINT MULTIPLIERS TABLE C2.4.4 CONCRETE ROOF DECK: DROPPED SUMMER AND WINTER POINT MULTIPLIERS |
783 | TABLE C2.4.5 FLOORS MULTIPLIERS FOR STEM WALL WITH STEM WALL INSULATION EQUATION C4.1.1 TABLE C4.1.2A COOLING SYSTEM MULTIPLIER ASSUMED, MINIMUM RATINGSBY DATE PERMITTED AIR CONDITIONERS TABLE C4.1.2B COOLING SYSTEM MULTIPLIER ASSUMED, MINIMUM RATINGSBY DATE PERMITTED AIR CONDITIONERS |
784 | TABLE C4.2.1.1 FAN SIZING TABLE TABLE C4.2 COOLING SYSTEM MULTIPLIERS GAS FUELED AIR CONDITIONERS |
786 | FIGURE C4.2.1.4 ACCEPTABLE ATTIC RADIANT BARRIER CONFIGURATIONS |
787 | TABLE C4.3.1.3A HEATING SYSTEM CREDIT MULTIPLIERS FOR COMBINED HYDRONIC SPACE GAS WATER HEATING WITH A STORAGE TANK TABLE C4.3.1.3B HEATING SYSTEM CREDIT MULTIPLIERS FOR COMBINED HYDRONIC INSTANTANEOUS (TANKLESS) GAS WATER HEATING |
788 | TABLE C4.3.2 HEATING SYSTEM MULTIPLIERS GAS FUELED HEAT PUMPS |
789 | TABLE C5.2.1A DUCT MULTIPLIERS NORTH FLORIDA |
790 | TABLE C5.2.1A DUCT MULTIPLIERS NORTH FLORIDA (CONTINUED) |
791 | TABLE C5.2.1B DUCT MULTIPLIERS CENTRAL FLORIDA |
792 | TABLE C5.2.1B DUCT MULTIPLIERS CENTRAL FLORIDA (CONTINUED) |
793 | TABLE C 5.2.1CDUCT MULTIPLIERS SOUTH FLORIDA |
794 | TABLE C5.2.1C DUCT MULTIPLIERS SOUTH FLORIDA( CONTINUED) |
795 | TABLE C6.2.1 GAS INSTANTANEOUS (TANKLESS) WATER HEATER MULTIPLIERS |
797 | SUBAPPENDIX G-D FORMS |
799 | FORM 600A-07 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION ALTERNATE RESIDENTIAL POINTS SYSTEM METHOD NORTH 1 2 3 |
805 | FORM 600A-07 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION ALTERNATE RESIDENTIAL POINTS SYSTEM METHOD CENTRAL 4 5 6 |
811 | FORM 600A-07 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION ALTERNATE RESIDENTIAL POINTS SYSTEM METHOD SOUTH 7 8 9 |
817 | 1100B-07 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTIONFORM RESIDENTIAL COMPONENT PRESCRIPTIVE METHOD B NORTH 1 2 3 |
819 | FORM 1100B-07 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION RESIDENTIAL COMPONENT PRESCRIPTIVE METHOD B CENTRAL 4 5 6 |
821 | FORM 1100B-07 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION RESIDENTIAL COMPONENT PRESCRIPTIVE METHOD B SOUTH 7 8 9 |
823 | FORM 1100C-07 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION RESIDENTIAL LIMITED APPLICATIONS PRESCRIPTIVE METHOD C NORTH 1 2 3 SMALL ADDITIONS, RENOVATIONS & BUILDING SYSTEMS |
825 | FORM 1100C-07 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION RESIDENTIAL LIMITED APPLICATIONS PRESCRIPTIVE METHOD C CENTRAL 4 5 6 SMALL ADDITIONS, RENOVATIONS & BUILDING SYSTEMS |
827 | FORM 1100C-07 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION RESIDENTIAL LIMITED APPLICATIONS PRESCRIPTIVE METHOD C SOUTH 7 8 9 SMALL ADDITIONS, RENOVATIONS & BUILDING SYSTEMS |
829 | FORM 1100D-07 |
830 | ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD |
831 | SUBAPPENDIX G-E FLORIDA STANDARD NO. 1 (FL-1) FLORIDA REGULATORY MODIFICATIONS TO AIR-CONDITIONING & REFRIGERATION INSTITUTE (ARI) STANDARD 470-80 EFFECTIVE APRILl 1, 1986 SECTION 1 PURPOSE SECTION 2 SCOPE SECTION 3 DEFINITIONS SECTION 4 STANDARD EQUIPMENT AND ACCESSORIES SECTION 5 TESTING AND RATING REQUIREMENTS |
832 | SECTION 7 MARKING SECTION 8 CONFORMANCE SECTION A2 SCOPE SECTION A3 DEFINITIONS SECTION A4 EXPRESSION OF TEST RESULTS SECTION A5 TEST METHODS |
833 | APPENDIX H PATIO COVERS RESERVED |
835 | APPENDIX I PRIVATE SEWAGE DISPOSAL RESERVED |
837 | [EB] APPENDIX J EXISTING BUILDINGS AND STRUCTURES RESERVED |
839 | APPENDIX K SOUND TRANSMISSION RESERVED |
841 | APPENDIX L PERMIT FEES RESERVED |
843 | APPENDIX M HOME DAY CARE—R-3 OCCUPANCY RESERVED |
845 | APPENDIX N VENTING METHODS RESERVED |
847 | APPENDIX O GRAY WATER RECYCLING SYSTEMS SECTION AO101 GENERAL SECTION AO102 SYSTEMS FOR FLUSHING WATERCLOSETS AND URINALS |
848 | FIGURE AO101.1(1) GRAY WATER RECYCLING SYSTEM FOR FLUSHING WATER CLOSETS AND URINALS FIGURE AO101.1(2) GRAY WATER RECYCLING SYSTEM FOR SUBSURFACE LANDSCAPE IRRIGATION |
849 | SECTION AO103 SUBSURFACE LANDSCAPE IRRIGATION SYSTEMS (EQUATION AO-1) |
850 | TABLE AO103.8 LOCATION OF GRAY WATER SYSTEM TABLE AO103.9.1 DESIGN LOADING RATE TABLE AO103.10 DISTRIBUTION PIPE |
851 | APPENDIX P FIRE SPRINKLER SYSTEM RESERVED |
853 | APPENDIX Q ICC IRC ELECTRICAL PROVISIONS/NATIONAL ELECTRICAL CODE CROSS-REFERENCE RESERVED |
855 | INDEX |
865 | SIGNIFICANT CHANGES TO THE FLORIDA BUILDING CODE, 2007 EDITION SIGNIFICANT CHANGES TO THE FLORIDA RESIDENTIAL CODE, 2007 EDITION 2007 FLORIDA COMMENTARIES |
866 | ICC MEMBERSHIP INFORMATION |
867 | REFERENCED STANDARDS |
868 | INTERNATIONAL CODE COUNCIL® ORDER FORM |
869 | 2007 FLORIDA BUILDING CODE CHAPTER 1 BUILDING |
871 | CHAPTER 1 ADMINISTRATION SECTION 101 GENERAL SECTION 102 APPLICABILITY |
873 | SECTION 103 DEPARTMENT OF BUILDING SAFETY RESERVED SECTION 104 DUTIES AND POWERS OF THE BUILDING OFFICIAL SECTION 105 PERMITS |
877 | SECTION 106 CONSTRUCTION DOCUMENTS |
880 | SECTION 107 TEMPORARY STRUCTURES AND USES SECTION 108 FEES |
881 | SECTION 109 INSPECTIONS |
883 | SECTION 110 CERTIFICATES OF OCCUPANCY AND COMPLETION |
884 | SECTION 111 SERVICE UTILITIES SECTION 112 BOARD OF APPEALS RESERVED SECTION 113 VIOLATIONS RESERVED SECTION 114 STOP WORK ORDER SECTION 115 UNSAFE STRUCTURES AND EQUIPMENT RESERVED |