Shopping Cart

No products in the cart.

ICC IPC 2021 1stptg

$66.08

International Plumbing Code, 3rd Printing

Published By Publication Date Number of Pages
ICC 2021 271
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

The 2021 IPC® provides minimum regulations for plumbing facilities and provides for the acceptance of new and innovative products, materials, and systems. In October 2019, the Code Council released an independent study comparing model plumbing codes. Important changes in the 2021 IPC include: Multiple-user toilet facilities to serve all genders are now permitted. Two new methods for relining/rehabilitation of existing sewers are added. Accommodations for mounted roof top solar panels over vent terminals is added. CSA B805/ICC 805 Rainwater Harvesting Systems is allowed as an alternative design method. Plumbing provisions from ICC A117.1-2017 Standard for Usable and Accessible Buildings and Facilities are now included.

PDF Catalog

PDF Pages PDF Title
1 2021 IPC® INTERNATIONAL PLUMBING CODE®
2 2021 IPC® INTERNATIONAL PLUMBING CODE® TITLE PAGE
3 COPYRIGHT
4 PREFACE
10 ARRANGEMENT AND FORMAT OF THE 2021 IPC
14 TABLE OF CONTENTS
18 CHAPTER 1 SCOPE AND ADMINISTRATION
PART 1—SCOPE AND APPLICATION
SECTION 101 SCOPE AND GENERAL REQUIREMENTS
SECTION 102 APPLICABILITY
19 PART 2—ADMINISTRATION AND ENFORCEMENT
SECTION 103 CODE COMPLIANCE AGENCY
SECTION 104 DUTIES AND POWERS OF THE CODE OFFICIAL
20 SECTION 105 APPROVAL
SECTION 106 PERMITS
22 SECTION 107 TEMPORARY EQUIPMENT, SYSTEMS AND USES
SECTION 108 INSPECTIONS AND TESTING
23 SECTION 109 FEES
SECTION 110 CONSTRUCTION DOCUMENTS
24 SECTION 111 NOTICE OF APPROVAL
SECTION 112 SERVICE UTILITIES
SECTION 113 STOP WORK ORDER
SECTION 114 MEANS OF APPEALS
25 SECTION 115 VIOLATIONS
26 CHAPTER 2 DEFINITIONS
SECTION 201 GENERAL
SECTION 202 GENERAL DEFINITIONS
34 CHAPTER 3 GENERAL REGULATIONS
SECTION 301 GENERAL
SECTION 302 EXCLUSION OF MATERIALS DETRIMENTAL TO THE SEWER SYSTEM
SECTION 303 MATERIALS
35 SECTION 304 RODENTPROOFING
SECTION 305 PROTECTION OF PIPES AND PLUMBING SYSTEM COMPONENTS
SECTION 306 TRENCHING, EXCAVATION AND BACKFILL
36 SECTION 307 STRUCTURAL SAFETY
SECTION 308 PIPING SUPPORT
37 TABLE 308.5 HANGER SPACIN
SECTION 309 FLOOD HAZARD RESISTANCE
38 SECTION 310 WASHROOM AND TOILET ROOM REQUIREMENTS
SECTION 311 TOILET FACILITIES FOR WORKERS
SECTION 312 TESTS AND INSPECTIONS
39 SECTION 313 EQUIPMENT EFFICIENCIES
SECTION 314 CONDENSATE DISPOSAL
[M] TABLE 314.2.2 CONDENSATE DRAIN S
40 SECTION 315 PENETRATIONS
SECTION 316 ALTERNATIVE ENGINEERED DESIGN
42 CHAPTER 4 FIXTURES, FAUCETS AND FIXTURE FITTINGS
SECTION 401 GENERAL
SECTION 402 FIXTURE MATERIALS
SECTION 403 MINIMUM PLUMBING FACILITIES
TABLE 403.1 MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURESa (See Sections 403.1.1 and 403.2)
43 TABLE 403.1—continued MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURESa (See Sections 403.1.1 and 403.2)
44 TABLE 403.1—continued MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURESa (See Sections 403.1.1 and 403.2)
46 SECTION 404 ACCESSIBLE PLUMBING FACILITIES
SECTION 405 INSTALLATION OF FIXTURES
48 SECTION 406 AUTOMATIC CLOTHES WASHERS
SECTION 407 BATHTUBS
SECTION 408 BIDETS
SECTION 409 DISHWASHING MACHINES
SECTION 410 DRINKING FOUNTAINS
49 SECTION 411 EMERGENCY SHOWERS AND EYEWASH STATIONS
SECTION 412 FAUCETS AND FIXTURE FITTINGS
50 SECTION 413 FLOOR AND TRENCH DRAINS
SECTION 414 FLOOR SINKS
SECTION 415 FLUSHING DEVICES FOR WATER CLOSETS AND URINALS
51 SECTION 416 FOOD WASTE DISPOSER UNITS
SECTION 417 GARBAGE CAN WASHERS
SECTION 418 LAUNDRY TRAYS
SECTION 419 LAVATORIES
SECTION 420 MANUAL FOOD AND BEVERAGE DISPENSING EQUIPMENT
SECTION 421 SHOWERS
53 SECTION 422 SINKS
SECTION 423 SPECIALTY PLUMBING FIXTURES
SECTION 424 URINALS
SECTION 425 WATER CLOSETS
SECTION 426 WHIRLPOOL BATHTUBS
54 CHAPTER 5 WATER HEATERS
SECTION 501 GENERAL
SECTION 502 INSTALLATION
55 SECTION 503 CONNECTIONS
SECTION 504 SAFETY DEVICES
56 SECTION 505 INSULATION
58 CHAPTER 6 WATER SUPPLY AND DISTRIBUTION
SECTION 601 GENERAL
SECTION 602 WATER REQUIRED
59 SECTION 603 WATER SERVICE
SECTION 604 DESIGN OF BUILDING WATER DISTRIBUTION SYSTEM
TABLE 604.3 WATER DISTRIBUTION SYSTEM DESIGN CRITERIA REQUIRED CAPACITY AT FIXTURE SUPPLY PIPE OUTLETS
60 TABLE 604.4 MAXIMUM FLOW RATES AND CONSUMPTION FOR PLUMBING FIXTURES AND FIXTURE FITTINGS
TABLE 604.5 MINIMUM SIZES OF FIXTURE WATER SUPPLY PIPES
61 TABLE 604.10.1 MANIFOLD SIZING
SECTION 605 MATERIALS, JOINTS AND CONNECTIONS
TABLE 605.3 WATER SERVICE PIPE
62 TABLE 605.4 WATER DISTRIBUTION PIPE
TABLE 605.7 VALVES
63 TABLE 605.5 PIPE FITTINGS
TABLE 605.8 MANUFACTURED PIPE NIPPLES
66 SECTION 606 INSTALLATION OF THE BUILDING WATER DISTRIBUTION SYSTEM
67 TABLE 606.5.4 SIZES FOR OVERFLOW PIPES FOR WATER SUPPLY TANKS
TABLE 606.5.7 SIZE OF DRAIN PIPES FOR WATER TANKS
SECTION 607 HOT WATER SUPPLY SYSTEM
68 SECTION 608 PROTECTION OF POTABLE WATER SUPPLY
69 TABLE 608.1 APPLICATION OF BACKFLOW PREVENTERS
70 FIGURE 608.9.1 PICTOGRAPH—DO NOT DRINK
71 TABLE 608.9.2.2 SIZE OF PIPE IDENTIFICATION
72 TABLE 608.16.1 MINIMUM REQUIRED AIR GAPS
74 TABLE 608.18.1 DISTANCE FROM CONTAMINATION TO PRIVATE WATER SUPPLIES AND PUMP SUCTION LINES
SECTION 609 HEALTH CARE PLUMBING
75 SECTION 610 DISINFECTION OF POTABLE WATER SYSTEM
SECTION 611 DRINKING WATER TREATMENT UNITS
SECTION 612 SOLAR SYSTEMS
SECTION 613 TEMPERATURE CONTROL DEVICES AND VALVES
76 CHAPTER 7 SANITARY DRAINAGE
SECTION 701 GENERAL
SECTION 702 MATERIALS
TABLE 702.1 ABOVE-GROUND DRAINAGE AND VENT PIPE
77 TABLE 702.2 UNDERGROUND BUILDING DRAINAGE AND VENT PIPE
TABLE 702.3 BUILDING SEWER PIPE
78 TABLE 702.4 PIPE FITTINGS
SECTION 703 BUILDING SEWER
SECTION 704 DRAINAGE PIPING INSTALLATION
TABLE 704.1 SLOPE OF HORIZONTAL DRAINAGE PIPE
79 SECTION 705 JOINTS
81 TABLE 705.18 CAULKING FERRULE SPECIFICATIONS
TABLE 705.19 SOLDERING BUSHING SPECIFICATIONS
SECTION 706 CONNECTIONS BETWEEN DRAINAGE PIPING AND FITTINGS
82 TABLE 706.3 FITTINGS FOR CHANGE IN DIRECTION
SECTION 707 PROHIBITED JOINTS AND CONNECTIONS
SECTION 708 CLEANOUTS
83 SECTION 709 FIXTURE UNITS
TABLE 709.2 DRAINAGE FIXTURE UNITS FOR FIXTURE DRAINS OR TRAPS
84 TABLE 709.1 DRAINAGE FIXTURE UNITS FOR FIXTURES AND GROUPS
85 SECTION 710 DRAINAGE SYSTEM SIZING
TABLE 710.1(1) BUILDING DRAINS AND SEWERS
TABLE 710.1(2) HORIZONTAL FIXTURE BRANCHES AND STACKSa
SECTION 711 OFFSETS IN DRAINAGE PIPING IN BUILDINGS OF FIVE STORIES OR MORE
86 SECTION 712 SUMPS AND EJECTORS
87 TABLE 712.4.2 MINIMUM CAPACITY OF SEWAGE PUMP OR SEWAGE EJECTOR
SECTION 713 COMPUTERIZED DRAINAGE DESIGN
SECTION 714 BACKWATER VALVES
SECTION 715 VACUUM DRAINAGE SYSTEMS
SECTION 716 REPLACEMENT OF UNDERGROUND BUILDING SEWERS AND BUILDING DRAINS BY PIPE-BURSTING METHODS
88 SECTION 717 RELINING BUILDING SEWERS AND BUILDING DRAINS
SECTION 718 REHABILITATION OF BUILDING SEWERS AND BUILDING DRAINS
90 CHAPTER 8 INDIRECT/SPECIAL WASTE
SECTION 801 GENERAL
SECTION 802 INDIRECT WASTES
91 SECTION 803 SPECIAL WASTES
92 CHAPTER 9 VENTS
SECTION 901 GENERAL
SECTION 902 MATERIALS
SECTION 903 VENT TERMINALS
93 SECTION 904 OUTDOOR VENT EXTENSIONS
SECTION 905 VENT CONNECTIONS AND GRADES
SECTION 906 VENT PIPE SIZING
94 TABLE 906.1 SIZE AND DEVELOPED LENGTH OF STACK VENTS AND VENT STACKS
95 TABLE 906.5.1 SIZE AND LENGTH OF SUMP VENTS
SECTION 907 VENTS FOR STACK OFFSETS
SECTION 908 RELIEF VENTS—STACKS OF MORE THAN 10 BRANCH INTERVALS
96 SECTION 909 FIXTURE VENTS
TABLE 909.1 MAXIMUM DISTANCE OF FIXTURE TRAP FROM VENT
SECTION 910 INDIVIDUAL VENT
SECTION 911 COMMON VENT
TABLE 911.3 COMMON VENT SIZES
SECTION 912 WET VENTING
97 TABLE 912.3 WET VENT SIZE
SECTION 913 WASTE STACK VENT
TABLE 913.4 WASTE STACK VENT SIZE
SECTION 914 CIRCUIT VENTING
98 SECTION 915 COMBINATION WASTE AND VENT SYSTEM
TABLE 915.2.2 SIZE OF COMBINATION WASTE AND VENT PIPE
SECTION 916 ISLAND FIXTURE VENTING
SECTION 917 SINGLE-STACK VENT SYSTEM
99 TABLE 917.2 SINGLE STACK SIZE
SECTION 918 AIR ADMITTANCE VALVES
100 SECTION 919 ENGINEERED VENT SYSTEMS
TABLE 919.2 MINIMUM DIAMETER AND MAXIMUM LENGTH OF INDIVIDUAL BRANCH FIXTURE VENTS AND INDIVIDUAL FIXTURE HEADER VENTS FOR SMOOTH PIPES
EQUATION 9-1
SECTION 920 COMPUTERIZED VENT DESIGN
102 CHAPTER 10 TRAPS, INTERCEPTORS AND SEPARATORS
SECTION 1001 GENERAL
SECTION 1002 TRAP REQUIREMENTS
103 SECTION 1003 INTERCEPTORS AND SEPARATORS
104 TABLE 1003.3.5.1 CAPACITY OF GREASE INTERCEPTORS
105 SECTION 1004 MATERIALS, JOINTS AND CONNECTIONS
106 CHAPTER 11 STORM DRAINAGE
SECTION 1101 GENERAL
SECTION 1102 MATERIALS
TABLE 1102.4 BUILDING STORM SEWER PIPE
107 TABLE 1102.5 SUBSOIL DRAIN PIPE
TABLE 1102.7 PIPE FITTINGS
SECTION 1103 TRAPS
SECTION 1104 CONDUCTORS AND CONNECTIONS
SECTION 1105 ROOF DRAINS
108 SECTION 1106 SIZE OF CONDUCTORS, LEADERS AND STORM DRAINS
EQUATION 11-1
TABLE 1106.2 STORM DRAIN PIPE SIZING
TABLE 1106.3 VERTICAL LEADER SIZING
109 FIGURE 1106.1(1) 100-YEAR, 1-HOUR RAINFALL (INCHES) WESTERN UNITED STATES
110 FIGURE 1106.1(2) 100-YEAR, 1-HOUR RAINFALL (INCHES) CENTRAL UNITED STATES
111 FIGURE 1106.1(3) 100-YEAR, 1-HOUR RAINFALL (INCHES) EASTERN UNITED STATES
112 FIGURE 1106.1(4) 100-YEAR, 1-HOUR RAINFALL (INCHES) ALASKA
113 FIGURE 1106.1(5) 100-YEAR, 1-HOUR RAINFALL (INCHES) HAWAII
114 TABLE 1106.6 HORIZONTAL GUTTER SIZING
SECTION 1107 SIPHONIC ROOF DRAINAGE SYSTEMS
SECTION 1108 SECONDARY (EMERGENCY) ROOF DRAINS
SECTION 1109 COMBINED SANITARY AND STORM PUBLIC SEWER
SECTION 1110 CONTROLLED FLOW ROOF DRAIN SYSTEMS
115 SECTION 1111 SUBSOIL DRAINS
SECTION 1112 BUILDING SUBDRAINS
SECTION 1113 SUMPS AND PUMPING SYSTEMS
116 CHAPTER 12 SPECIAL PIPING AND STORAGE SYSTEMS
SECTION 1201 GENERAL
SECTION 1202 MEDICAL GASES
SECTION 1203 OXYGEN SYSTEMS
118 CHAPTER 13 NONPOTABLE WATER SYSTEMS
SECTION 1301 GENERAL
FIGURE 1301.3 PICTOGRAPH—DO NOT DRINK
120 SECTION 1302 ON-SITE NONPOTABLE WATER REUSE SYSTEMS
121 TABLE 1302.7.1 LOCATION OF NONPOTABLE WATER REUSE STORAGE TANKS
122 SECTION 1303 NONPOTABLE RAINWATER COLLECTION AND DISTRIBUTION SYSTEMS
123 TABLE 1303.10.1 LOCATION OF RAINWATER STORAGE TANKS
124 SECTION 1304 RECLAIMED WATER SYSTEMS
126 CHAPTER 14 SUBSURFACE GRAYWATER SOIL ABSORPTION SYSTEMS
SECTION 1401 GENERAL
SECTION 1402 SYSTEM DESIGN AND SIZING
EQUATION 14-1
127 TABLE 1402.3 LOCATION OF SUBSURFACE GRAYWATER SOIL ABSORPTION SYSTEM
SECTION 1403 INSTALLATION
TABLE 1403.1.1 DESIGN LOADING RATE
128 TABLE 1403.2 DISTRIBUTION PIPE
TABLE 1403.2 DISTRIBUTION PIPE
130 CHAPTER 15 REFERENCED STANDARDS
ANSI
ASHRAE
ASME
132 ASPE
133 ASSE
135 ASTM
140 AWS
AWWA
141 CISPI
CSA
143 IAPMO
144 ICC
ISEA
MSS
145 NFPA
NGWA
NSF
146 PDI
PSAI
UL
148 APPENDIX A PLUMBING PERMIT FEE SCHEDULE
TABLE A101 EXAMPLE OF PERMIT FEE SCHEDULE
PERMIT ISSUANCE
UNIT FEE SCHEDULE
OTHER INSPECTIONS AND FEES
150 APPENDIX B RATES OF RAINFALL FOR VARIOUS CITIES
TABLE B101 RATES OF RAINFALL FOR VARIOUS CITIESa
151 TABLE B101—continued RATES OF RAINFALL FOR VARIOUS CITIESa
152 TABLE B101—continued RATES OF RAINFALL FOR VARIOUS CITIESa
153 TABLE B101—continued RATES OF RAINFALL FOR VARIOUS CITIESa
154 APPENDIX C STRUCTURAL SAFETY
SECTION C101 CUTTING, NOTCHING AND BORING IN WOOD MEMBERS
156 APPENDIX D DEGREE DAY AND DESIGN TEMPERATURES
TABLE D101 DEGREE DAY AND DESIGN TEMPERATURESa FOR CITIES IN THE UNITED STATES
157 TABLE D101—continued DEGREE DAY AND DESIGN TEMPERATURESa FOR CITIES IN THE UNITED STATES
158 TABLE D101—continued DEGREE DAY AND DESIGN TEMPERATURESa FOR CITIES IN THE UNITED STATES
159 TABLE D101—continued DEGREE DAY AND DESIGN TEMPERATURESa FOR CITIES IN THE UNITED STATES
160 TABLE D101—continued DEGREE DAY AND DESIGN TEMPERATURESa FOR CITIES IN THE UNITED STATES
161 TABLE D101—continued DEGREE DAY AND DESIGN TEMPERATURESa FOR CITIES IN THE UNITED STATES
162 APPENDIX E SIZING OF WATER PIPING SYSTEM
SECTION E101 GENERAL
SECTION E102 INFORMATION REQUIRED
SECTION E103 SELECTION OF PIPE SIZE
166 TABLE E103.3.1(1) SUMMATION OF DEVELOPED PIPE LENGTHS
167 TABLE E103.3.1(2) FITTING PRESSURE LOSSES EXPRESSED IN EQUIVALENT LENGTHS
TABLE E103.3.1(3) TOTAL FRICTION LOSS EQUIVALENT PIPING LENGTH
168 FIGURE E103.3(1) EXAMPLE—SIZING
169 TABLE E103.3(1) RECOMMENDED TABULAR ARRANGEMENT FOR USE IN SOLVING PIPE SIZING PROBLEMS
170 TABLE E103.3(2) LOAD VALUES ASSIGNED TO FIXTURESa
171 TABLE E103.3(3) TABLE FOR ESTIMATING DEMAND
172 TABLE E103.3(3)—continued TABLE FOR ESTIMATING DEMAND
TABLE E103.3(4) LOSS OF PRESSURE THROUGH TAPS AND TEES IN POUNDS PER SQUARE INCH (psi)
173 TABLE E103.3(5) ALLOWANCE IN EQUIVALENT LENGTHS OF PIPE FOR FRICTION LOSS IN VALVES AND THREADED FITTINGS (feet)
TABLE E103.3(6) PRESSURE LOSS IN FITTINGS AND VALVES EXPRESSED AS EQUIVALENT LENGTH OF TUBEa (feet)
174 FIGURE E103.3(2) FRICTION LOSS IN SMOOTH PIPEa (TYPE K, ASTM B88 COPPER TUBING)
175 FIGURE E103.3(3) FRICTION LOSS IN SMOOTH PIPEa (TYPE L, ASTM B88 COPPER TUBING)
176 FIGURE E103.3(4) FRICTION LOSS IN SMOOTH PIPEa (TYPE M, ASTM B88 COPPER TUBING)
177 FIGURE E103.3(5) FRICTION LOSS IN FAIRLY SMOOTH PIPEa
178 FIGURE E103.3(6) FRICTION LOSS IN FAIRLY ROUGH PIPEa
179 FIGURE E103.3(7) FRICTION LOSS IN ROUGH PIPEa
180 SECTION E104 SELECTION OF PIPE SIZE
SECTION E105 DETERMINATION OF PIPE VOLUMES
181 TABLE E104.1 MINIMUM SIZE OF WATER METERS, MAINS AND DISTRIBUTION PIPING BASED ON WATER SUPPLY FIXTURE UNIT VALUES (w.s.f.u.)
182 TABLE E104.1—continued MINIMUM SIZE OF WATER METERS, MAINS AND DISTRIBUTION PIPING BASED ON WATER SUPPLY FIXTURE UNIT VALUES (w.s.f.u.)
183 TABLE E105.1 INTERNAL VOLUME OF VARIOUS WATER DISTRIBUTION TUBING
184 [A] APPENDIX F BOARD OF APPEALS
[A] SECTION F101 GENERAL
186 INDEX
198 RESOURCE A PLUMBING PROVISIONS EXCERPTED FROM: ICC A117.1–2017 STANDARD FOR ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES
200 PLUMBING PROVISIONS EXCERPTED FROM: ICC A117.1-2017 STANDARD FOR ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES TITLE PAGE
201 COPYRIGHT
202 TABLE OF CONTENTS
204 CHAPTER 1 APPLICATION AND ADMINISTRATION
SECTION 101 TITLE
SECTION 102 PURPOSE
SECTION 103 HUMAN FACTOR PROVISIONS
SECTION 104 COMPLIANCE ALTERNATIVES
SECTION 105 CONVENTIONS
SECTION 106 REFERENCED DOCUMENTS
205 FIGURE 105.4 GRAPHIC CONVENTION FOR FIGURES
206 SECTION 107 DEFINITIONS
210 CHAPTER 3 BUILDING BLOCKS
SECTION 301 GENERAL
SECTION 302 FLOOR SURFACES
FIGURE 302.2 CARPET ON FLOOR SURFACES
FIGURE 302.3 OPENINGS IN FLOOR SURFACES
FIGURE 303.2 VERTICAL CHANGE IN LEVEL
FIGURE 303.3 BEVELED CHANGES IN LEVEL
SECTION 303 CHANGES IN LEVEL
211 SECTION 304 TURNING SPACE
FIGURE 304.3.1.1 CIRCULAR TURNING SPACE – NEW BUILDINGS SIZE AND OVERLAP
FIGURE 304.3.1.2 CIRCULAR TURNING SPACE – EXISTING BUILDINGS – SIZE AND OVERLAP
FIGURE 304.3.2.1(A) T-SHAPED TURNING SPACE NEW BUILDINGS – OPTION 1
212 FIGURE 304.3.2.1(B) T-SHAPED TURNING SPACE NEW BUILDINGS – OPTION 2
FIGURE 304.3.2.1(C) T-SHAPED TURNING SPACE NEW BUILDINGS – OPTION 3
FIGURE 304.3.2.1.1 T-SHAPED TURNING SPACE NEW BUILDINGS – OVERLAP
213 FIGURE 304.3.2.2 T-SHAPED TURNING SPACE EXISTING BUILDINGS – SIZE
FIGURE 304.3.2.2.1 T-SHAPED TURNING SPACE – EXISTING BUILDINGS OVERLAP
SECTION 305 CLEAR FLOOR SPACE
FIGURE 305.3.1 SIZE OF CLEAR FLOOR SPACE – NEW BUILDINGS
FIGURE 305.3.2 SIZE OF CLEAR FLOOR SPACE – EXISTING BUILDINGS
214 FIGURE 305.5(A) POSITION OF CLEAR FLOOR SPACE – FORWARD
FIGURE 305.5(B) POSITION OF CLEAR FLOOR SPACE – PARALLEL
FIGURE 305.7.1 MANEUVERING CLEARANCE IN AN ALCOVE PARALLEL APPROACH
FIGURE 305.7.2 MANEUVERING CLEARANCE IN AN ALCOVE FORWARD APPROACH
SECTION 306 KNEE AND TOE CLEARANCE
215 FIGURE 306.2(A) TOE CLEARANCE – ELEVATION
FIGURE 306.2(B) TOE CLEARANCE – PLAN
FIGURE 306.3(A) KNEE CLEARANCE – ELEVATION
FIGURE 306.3(B) KNEE CLEARANCE – PLAN
216 SECTION 307 PROTRUDING OBJECTS
FIGURE 307.2 LIMITS OF PROTRUDING OBJECTS
FIGURE 307.3(A) POST-MOUNTED PROTRUDING OBJECTS
FIGURE 307.3(B) POST-MOUNTED PROTRUDING OBJECTS
217 FIGURE 307.4 REDUCED VERTICAL CLEARANCE
SECTION 308 REACH RANGES
FIGURE 308.2.1 UNOBSTRUCTED FORWARD REACH
FIGURE 308.2.2 OBSTRUCTED HIGH FORWARD REACH
218 FIGURE 308.3.1 UNOBSTRUCTED SIDE REACH
FIGURE 308.3.2(A) OBSTRUCTED HIGH SIDE REACH
FIGURE 308.3.2(B) OBSTRUCTED HIGH SIDE REACH
SECTION 309 OPERABLE PARTS
219 FIGURE 309.1 OPERABLE PARTS – EXCEPTION 3
220 CHAPTER 6 PLUMBING ELEMENTS AND FACILITIES
SECTION 601 GENERAL
SECTION 602 DRINKING FOUNTAINS AND BOTTLE FILLING STATIONS
FIGURE 602.2.1(A) CLEAR FLOOR SPACE AT WHEELCHAIR DRINKING FOUNTAINS
FIGURE 602.2.1(B) CLEAR FLOOR SPACE AT WHEELCHAIR DRINKING FOUNTAINS – PRIMARILY FOR CHILDREN’S USE EXCEPTION
FIGURE 602.2.3 WHEELCHAIR DRINKING FOUNTAIN SPOUT HEIGHT AND LOCATION
221 FIGURE 602.2.4 WHEELCHAIR DRINKING FOUNTAIN SPOUT LOCATION
FIGURE 602.3.2 STANDING USE DRINKING FOUNTAIN SPOUT HEIGHT AND LOCATION
FIGURE 602.3.3 STANDING USE DRINKING FOUNTAIN SPOUT LOCATION
SECTION 603 TOILET AND BATHING ROOMS
222 TABLE 603.6 MAXIMUM REACH DEPTH AND HEIGHT
SECTION 604 WATER CLOSETS AND TOILET COMPARTMENTS
FIGURE 604.2 WATER CLOSET LOCATION
223 FIGURE 604.3 SIZE OF CLEARANCE FOR WATER CLOSET
FIGURE 604.4 WATER CLOSET SEAT HEIGHT
224 FIGURE 604.5.1 SIDE-WALL GRAB BAR FOR WATER CLOSET
FIGURE 604.5.2 REAR-WALL GRAB BAR FOR WATER CLOSET
225 FIGURE 604.7.1(A) DISPENSER OUTLET LOCATION – PROTRUDING DISPENSER BELOW GRAB BAR
FIGURE 604.7.1(B) DISPENSER OUTLET LOCATION PROTRUDING DISPENSER ABOVE GRAB BAR
FIGURE 604.7.1(C) DISPENSER OUTLET LOCATION RECESSED DISPENSER
226 FIGURE 604.7.1(D) DISPENSER OUTLET LOCATION DISPENSER IN FRONT OF WATER CLOSET – EXCEPTION
FIGURE 604.9.2(A) WHEELCHAIR TOILET COMPARTMENTS WALL HUNG CLOSET, ADULT60 min152559 min1500FIGURE 604.9.2(B)WHEELCHAIR TOILET
FIGURE 604.9.2(B) WHEELCHAIR TOILET COMPARTMENTS FLOOR MOUNTED WATER CLOSET, ADULT – WALL HUNG AND FLOOR MOUNTED WATER CLOSET, CHILDREN
227 FIGURE 604.9.2.3 WHEELCHAIR TOILET COMPARTMENTS ALTERNATE WHEELCHAIR TOILET COMPARTMENT
FIGURE 604.9.3(A) WHEELCHAIR TOILET COMPARTMENT DOORS DOOR SWINGING INTO THE WHEELCHAIR TOILET COMPARTMENT
228 FIGURE 604.9.3(B) WHEELCHAIR TOILET COMPARTMENT DOORS EXCEPTION 3 – ALTERNATE WHEELCHAIR COMPARTMENT
FIGURE 604.9.3.1(A) WHEELCHAIR TOILET COMPARTMENT DOOR OPENING LOCATION – DOOR SWINGING IN ON FRONT WALL OF PARTITION
FIGURE 604.9.3.1(B) WHEELCHAIR TOILET COMPARTMENT DOOR OPENING LOCATION DOOR SWINGING IN ON SIDE WALL OF PARTITIONS
229 TABLE 604.9.3.1 —DOOR OPENING LOCATION
FIGURE 604.9.5(A) TOE CLEARANCE – ELEVATION
FIGURE 604.9.5(B) TOE CLEARANCE – PLAN
230 FIGURE 604.10.1 AMBULATORY COMPARTMENT
FIGURE 604.11.2 CHILDREN’S WATER CLOSET LOCATION
FIGURE 604.11.4 CHILDREN’S WATER CLOSET HEIGHT
231 FIGURE 604.11.7(A) CHILDREN’S DISPENSER OUTLET – LOCATION
FIGURE 604.11.7(B) CHILDREN’S DISPENSER OUTLET – EXCEPTION
SECTION 605 URINALS
FIGURE 605.2(A) HEIGHT AND DEPTH OF URINAL WALL HUNG TYPE
232 FIGURE 605.2(B) HEIGHT AND DEPTH OF URINAL STALL TYPE
SECTION 606 LAVATORIES AND SINKS
FIGURE 606.3 HEIGHT OF LAVATORIES AND SINKS
233 SECTION 607 BATHTUBS
FIGURE 607.2(A) CLEARANCE FOR BATHTUBS WITH REMOVABLE IN TUB SEATS
FIGURE 607.2(B) CLEARANCE FOR BATHTUBS WITH SEAT AT HEAD END OF TUB
234 FIGURE 607.4.1(A) GRAB BARS FOR BATHTUBS WITH SEAT AT HEAD END OF TUB – ELEVATION
FIGURE 607.4.1(B) GRAB BARS FOR BATHTUBS WITH SEAT AT HEAD END OF TUB – PLAN
FIGURE 607.4.2(A) GRAB BARS FOR BATHTUBS WITH REMOVABLE SEATS – ELEVATION
235 FIGURE 607.4.2(B) GRAB BARS FOR BATHTUBS WITH REMOVABLE SEATS – PLAN
FIGURE 607.5 LOCATION OF BATHTUB CONTROLS
SECTION 608 SHOWER COMPARTMENTS
FIGURE 608.2.1.1 TRANSFER-TYPE SHOWER COMPARTMENT SIZE
236 FIGURE 608.2.1.2(A) TRANSFER-TYPE SHOWER COMPARTMENT CLEARANCES NEW BUILDINGS – OPTION 1
FIGURE 608.2.1.2 (B) TRANSFER-TYPE SHOWER COMPARTMENT CLEARANCES NEW BUILDINGS – OPTION 2
FIGURE 608.2.1.2(C) TRANSFER-TYPE SHOWER COMPARTMENT CLEARANCES EXISTING BUILDINGS
FIGURE 608.2.2.1 STANDARD ROLL-IN-TYPE SHOWER COMPARTMENT SIZE
237 FIGURE 608.2.2.2 STANDARD ROLL-IN-TYPE SHOWER COMPARTMENT CLEARANCE
FIGURE 608.2.3.1 ALTERNATE ROLL-IN-TYPE SHOWER COMPARTMENT SIZE
238 FIGURE 608.3.1(A) GRAB BARS IN TRANSFER-TYPE SHOWER – ELEVATION
FIGURE 608.3.2(A) GRAB BARS IN STANDARD ROLL-IN-TYPE SHOWER ELEVATION
FIGURE 608.3.1(B) GRAB BARS IN TRANSFER-TYPE SHOWER – PLAN
FIGURE 608.3.2(B) GRAB BARS IN STANDARD ROLL-IN-TYPE SHOWER PLAN
239 FIGURE 608.3.3(A) GRAB BARS IN ALTERNATE ROLL-IN-TYPE SHOWER – ELEVATION
FIGURE 608.3.3(B) GRAB BARS IN ALTERNATE ROLL-IN-TYPE SHOWER – PLAN
FIGURE 608.4.1 TRANSFER-TYPE SHOWER CONTROLS AND HAND SHOWER LOCATION
FIGURE 608.4.2 STANDARD ROLL-IN-TYPE SHOWER CONTROLS AND HAND SHOWER LOCATION
240 FIGURE 608.4.3(A) ALTERNATE ROLL-IN-TYPE SHOWER CONTROLS AND HAND SHOWER LOCATION – END WALL – ELEVATION
FIGURE 608.4.3(B) ALTERNATE ROLL-IN-TYPE SHOWER CONTROLS AND HAND SHOWER LOCATION – CONTROL WALL – ELEVATION
SECTION 609 GRAB BARS
241 FIGURE 609.2 SIZE OF GRAB BARS
FIGURE 609.3 SPACING OF GRAB BARS
FIGURE 609.4.2(A) POSITIONS OF CHILDREN’S GRAB BARS SIDE-WALL VIEW
242 FIGURE 609.4.2(B) POSITIONS OF CHILDREN’S GRAB BARS REAR-WALL VIEW
SECTION 610 SEATS
FIGURE 610.2(A) BATHTUB SEATS REMOVABLE IN-TUB SEATS
FIGURE 610.2(B) BATHTUB SEATS SEAT PROVIDED AT HEAD END OF TUB
243 FIGURE 610.3.1 RECTANGULAR SHOWER COMPARTMENT SEATS
FIGURE 610.3.2 L-SHAPED SHOWER COMPARTMENT SEATS
SECTION 611 WASHING MACHINES AND CLOTHES DRYERS
244 FIGURE 611.2(A) CLEAR FLOOR SPACE – TOP LOADING
FIGURE 611.2(B) CLEAR FLOOR SPACE – FRONT LOADING
FIGURE 611.4(A) HEIGHT OF LAUNDRY EQUIPMENT – TOP LOADING
FIGURE 611.4(B) HEIGHT OF LAUNDRY EQUIPMENT – FRONT LOADING
245 SECTION 612 SAUNAS AND STEAM ROOMS
246 CHAPTER 8 SPECIAL ROOMS AND SPACES
SECTION 801 GENERAL
SECTION 804 KITCHENS
247 FIGURE 804.2.1(A) PASS-THROUGH KITCHEN CLEARANCE
FIGURE 804.2.1(B) PASS-THROUGH KITCHEN CLEARANCE
FIGURE 804.2.2(A) U-SHAPED KITCHEN CLEARANCE
FIGURE 804.2.2(B) U-SHAPED KITCHEN CLEARANCE
248 FIGURE 804.2.2(C) U-SHAPED KITCHEN CLEARANCE – EXCEPTION
250 CHAPTER 11 DWELLING UNITS AND SLEEPING UNITS
SECTION 1101 GENERAL
SECTION 1102 ACCESSIBLE UNITS
251 SECTION 1103 TYPE A UNITS
252 FIGURE 1103.11.2.4(A) WATER CLOSETS IN TYPE A UNITS – WATER CLOSET LOCATION
253 FIGURE 1103.11.2.4(B) WATER CLOSETS IN TYPE A UNITS – MINIMUM CLEARANCE
FIGURE 1103.11.2.4(C) WATER CLOSETS IN TYPE A UNITS – CLEARANCE WITH LAVATORY (OVERLAP EXCEPTION)
FIGURE 1103.11.2.4(D) WATER CLOSETS IN TYPE A UNITS – WATER CLOSET SEAT HEIGHT
FIGURE 1103.11.2.5.1(A) CLEARANCE FOR BATHTUBS IN TYPE A UNITS WITH REMOVABLE SEAT
FIGURE 1103.11.2.5.1(B) CLEARANCE FOR BATHTUBS IN TYPE A UNITS WITH PERMANENT SEAT
254 FIGURE 1103.11.2.5.2 STANDARD ROLL-IN-TYPE SHOWER COMPARTMENT IN TYPE A UNITS
FIGURE 1103.12.1.1 MINIMUM KITCHEN CLEARANCE IN TYPE A UNITS
255 FIGURE 1103.12.1.2(A) U-SHAPED KITCHEN CLEARANCE IN TYPE A UNITS
FIGURE 1103.12.1.2(B) U-SHAPED KITCHEN CLEARANCE IN TYPE A UNITS EXCEPTION
FIGURE 1103.12.3 WORK SURFACE IN KITCHEN FOR TYPE A UNITS
256 FIGURE 1103.12.4 KITCHEN SINK FOR TYPE A UNITS
257 SECTION 1104 TYPE B UNITS
FIGURE 1104.1.1 CLEAR FLOOR SPACE FOR TYPE B UNITS
258 FIGURE 1104.9 REACH OVER A KITCHEN OR BATHROOM CABINET
259 FIGURE 1104.11.1.1 SWING-UP GRAB BARS FOR WATER CLOSETS
260 FIGURE 1104.11.3.1.1 LAVATORY IN TYPE B UNITS – OPTION A BATHROOMS
FIGURE 1104.11.3.1.2(A) CLEARANCE AT WATER CLOSETS IN TYPE B UNITS WATER CLOSET LOCATION
FIGURE 1104.11.3.1.2(B) CLEARANCE AT WATER CLOSETS IN TYPE B UNITS CLEARANCE WIDTH AND DEPTH
261 FIGURE 1104.11.3.1.2(C) CLEARANCE AT WATER CLOSETS IN TYPE B UNITS INCREASED CLEARANCE DEPTH – FORWARD APPROACH
FIGURE 1104.11.3.1.2(D) CLEARANCE AT WATER CLOSETS IN TYPE B UNITS CLEARANCE WITH LAVATORY OVERLAP
262 FIGURE 1104.11.3.1.3.1 PARALLEL APPROACH BATHTUB IN TYPE B UNITS – OPTION A BATHROOM
263 FIGURE 1104.11.3.1.3.2 FORWARD APPROACH BATHTUB IN TYPE B UNITS OPTION A BATHROOM
FIGURE 1104.11.3.1.3.3(A) TRANSFER-TYPE SHOWER COMPARTMENT IN TYPE B UNITS
FIGURE 1104.11.3.1.3.3(B) TRANSFER-TYPE SHOWER COMPARTMENT IN TYPE B UNITS EXCEPTION
FIGURE 1104.11.3.2.1 LAVATORY IN TYPE B UNITS – OPTION B BATHROOM
264 FIGURE 1104.11.3.2.3.1 BATHROOM CLEARANCE IN TYPE B UNITS OPTION B BATHROOM
FIGURE 1104.12.1.1 MINIMUM CLEARANCE IN TYPE B UNITS
265 FIGURE 1104.12.1.2(A) U-SHAPED KITCHEN CLEARANCE IN TYPE B UNITS
FIGURE 1104.12.1.2(B) U-SHAPED KITCHEN CLEARANCE IN TYPE B UNITS – EXCEPTION
266 SECTION 1105 TYPE C (VISITABLE) UNITS
267 SECTION 1106 UNITS WITH COMMUNICATION FEATURES
268 ICC EVALUATION SERVICE
269 ICC LEARNING CENTER
270 ICC’S DIGITAL CODES LIBRARY
271 ICC MEMBERSHIP
ICC IPC 2021 1stptg
$66.08