Shopping Cart

No products in the cart.

MN ResidentialCode 07 2007

$44.15

Minnesota Residential Code

Published By Publication Date Number of Pages
MN 2007 400
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

 This Minnesota code based on the 2006 International Residential Code® building provisions. There are supplementary administrative information and schedules located in the appendices.

PDF Catalog

PDF Pages PDF Title
1 2007 MINNESOTA STATE RESIDENTIAL CODE, CHAPTER 1309
2 COPYRIGHT
3 TABLE OF CONTENTS
7 SYMBOLS AND NOTATIONS IN THE CODE
9 PART I — ADMINISTRATION
CHAPTER 1 ADMINISTRATION
11 MINNESOTA RULES, CHAPTER 1300
1300.0010 ADMINISTRATION
1300.0020 TITLE
1300.0030 PURPOSE AND APPLICATION
1300.0040 SCOPE
1300.0050 CHAPTERS OF MINNESOTA STATE BUILDING CODE
12 1300.0060 OPTIONAL ADMINISTRATION
1300.0070 DEFINITIONS
14 1300.0080 CODE ADOPTION AND AMENDMENTS
1300.0090 DEPARTMENT OF BUILDING SAFETY
1300.0110 DUTIES AND POWERS OF BUILDING OFFICIAL
15 1300.0120 PERMITS
17 1300.0130 CONSTRUCTION DOCUMENTS
18 1300.0140 VIOLATIONS
1300.0150 VIOLATIONS, PENALTY
1300.0160 FEES
19 1300.0170 STOP WORK ORDER
20 1300.0180 UNSAFE BUILDINGS OR STRUCTURES
1300.0190 TEMPORARY STRUCTURES AND USE
1300.0210 INSPECTIONS
21 1300.0220 CERTIFICATE OF OCCUPANCY
22 1300.0230 BOARD OF APPEALS
1300.0240 DISCLAIMER CLAUSE
1300.0250 SEVERABILITY
23 MINNESOTA RULES, CHAPTER 1303
1303.1000 TITLE
1303.1100 PURPOSE
1303.1200 RESTROOM FACILITIES IN PUBLIC ACCOMMODATIONS
1303.1300 PACE FOR COMMUTER VANS
1303.1400 AUTOMATIC GARAGE DOOR OPENING SYSTEMS
1303.1500 RECYCLING SPACE
TABLE 1-A MINIMUM RECYCLING SPACE REQUIREMENTS.
24 303.1600 FOOTING DEPTH FOR FROST PROTECTION
1303.1700 GROUND SNOW LOAD
1303.1800 RADIAL ICE ON TOWERS
1303.2000 EXTERIOR WOOD DECKS, PATIOS, AND BALCONIES
25 1303.2100 BLEACHER SAFETY
1303.2200 SIMPLIFIED WIND LOADS
EQUATION Palt
TABLE Palt
27 MINNESOTA RULES, CHAPTER 1309
1309.0010 ADOPTION OF INTERNATIONAL RESIDENTIALCODE (IRC) BY REFERENCE
1309.0020 REFERENCES TO OTHER ICC CODES
28 1309.0030 ADMINISTRATIVE PROCEDURE CRITERIA
1309.0040 VIOLATION
29 Part II — DEFINITIONS
CHAPTER 2 DEFINITIONS
SECTION R201 GENERAL
SECTION R202 DEFINITIONS
43 Part III — BUILDING PLANNING AND CONSTRUCTION
CHAPTER 3 BUILDING PLANNING
SECTION R300 CLASSIFICATION
TABLE R300.1O CCUPANCY CLASSIFICATION
SECTION R301 DESIGN CRITERIA
44 TABLE R301.2(1) CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA
TABLE R301.2.1.2 WINDBORNE DEBRIS PROTECTION FASTENING SCHEDULE FOR WOOD STRUCTURAL PANELSa,
45 TABLE R301.2(2) COMPONENT AND CLADDING LOADS FOR A BUILDING WITH A MEAN ROOF HEIGHT OF 30 FEET LOCATED IN EXPOSURE B (psf)
46 TABLE R301.2(3) HEIGHT AND EXPOSURE ADJUSTMENT COEFFICIENTS FOR TABLE R301.2(2)
FIGURE R301.2(1) ISOLINES OF THE 971/2 PERCENT WINTER (DECEMBER, JANUARY AND FEBRUARY) DESIGN TEMPERATURES (°F)
47 FIGURE R301.2(2) SEISMIC DESIGN CATEGORIES—SITE CLASS D
48 FIGURE R301.2(2)—continued SEISMIC DESIGN CATEGORIES—SITE CLASS D
49 FIGURE R301.2(2)—continued SEISMIC DESIGN CATEGORIES—SITE CLASS D
52 FIGURE R301.2(3) WEATHERING PROBABILITY MAP FOR CONCRETE
53 FIGURE R301.2(4) BASIC WIND SPEEDS FOR 50-YEAR MEAN RECURRENCE INTERVAL
54 FIGURE R301.2(4)—continued BASIC WIND SPEEDS FOR 50-YEAR MEAN RECURRENCE INTERVAL
55 FIGURE R301.2(4)—continued BASIC WIND SPEEDS FOR 50-YEAR MEAN RECURRENCE INTERVAL
56 FIGURE R301.2(4)—continued BASIC WIND SPEEDS FOR 50-YEAR MEAN RECURRENCE INTERVAL
57 FIGURE R301.2(4)—continued BASIC WIND SPEEDS FOR 50-YEAR MEAN RECURRENCE INTERVAL
58 FIGURE R301.2(6) TERMITE INFESTATION PROBABILITY MAP
59 FIGURE R301.2(7) COMPONENT AND CLADDING PRESSURE ZONES
60 TABLE R301.2.1.3 EQUIVALENT BASIC WIND SPEEDSa
61 TABLE R301.2.2.1.1 SEISMIC DESIGN CATEGORY DETERMINATION
TABLE R301.2.2.2.1 WALL BRACING ADJUSTMENT FACTORS BYROOF COVERING DEAD LOADa
64 TABLE R301.5 MINIMUM UNIFORMLY DISTRIBUTED LIVE LOADS (in pounds per square foot
TABLE R301.6 MINIMUM ROOF LIVE LOADS IN POUNDS-FORCEPER SQUARE FOOT OF HORIZONTAL PROJECTION
TABLE R301.7 ALLOWABLE DEFLECTION OF STRUCTURAL MEMBERSa,b,c
SECTION R302 EXTERIOR WALL LOCATION
65 SECTION R303 LIGHT, VENTILATION AND HEATING
TABLE R302.1 EXTERIOR WALLS
66 SECTION R304 MINIMUM ROOM AREAS
SECTION R305 CEILING HEIGHT
SECTION R306 SANITATION
67 SECTION R307 TOILET, BATH AND SHOWER SPACES
SECTION R308 GLAZING
FIGURE R307.1 MINIMUM FIXTURE CLEARANCES
68 TABLE R308.3 MINIMUM CATEGORY CLASSIFICATION OF GLAZING
69 SECTION R309 GARAGES AND CARPORTS
70 SECTION R310 EMERGENCY ESCAPE AND RESCUE OPENINGS
71 SECTION R311 MEANS OF EGRESS
73 SECTION R312 GUARDS
SECTION R313 SMOKE ALARMS
74 SECTION R314 FOAM PLASTIC
75 SECTION R315 FLAME SPREAD AND SMOKE DENSITY
76 SECTION R316 INSULATION
SECTION R317 DWELLING UNIT SEPARATION
78 SECTION R318 MOISTURE VAPOR RETARDERS
SECTION R319 PROTECTION AGAINST DECAY
79 SECTION R320 PROTECTION AGAINST SUBTERRANEAN TERMITES
80 SECTION R321 SITE ADDRESS
SECTION R322 ACCESSIBILITY
SECTION R323 ELEVATORS AND PLATFORM LIFTS
SECTION R324 FLOOD-RESISTANT CONSTRUCTION
85 CHAPTER 4 FOUNDATIONS
SECTION R401 GENERAL
TABLE R401.4.1 PRESUMPTIVE LOAD–BEARING VALUES OFFOUNDATION MATERIALSa
SECTION R402 MATERIALS
86 TABLE R402.2 MINIMUM SPECIFIED COMPRESSIVE STRENGTH OF CONCRETE
SECTION R403 FOOTINGS
TABLE R403.1 MINIMUM WIDTH OF CONCRETE OR MASONRY FOOTINGS (inches)
87 FIGURE R403.1(1) CONCRETE AND MASONRY FOUNDATION DETAILS
88 FIGURE R403.1(2) PERMANENT WOOD FOUNDATION BASEMENT WALL SECTION
89 FIGURE R403.1(3) PERMANENT WOOD FOUNDATION CRAWL SPACE SECTION
91 FIGURE R403.1.7.1 FOUNDATION CLEARANCE FROM SLOPES
92 TABLE R403.3 MINIMUM INSULATION REQUIREMENTS FOR FROST-PROTECTED FOOTINGS IN HEATED BUILDINGSa
FIGURE R403.3(1) INSULATION PLACEMENT FOR FROST-PROTECTED FOOTINGS IN HEATED BUILDINGS
93 FIGURE R403.3(2) AIR–FREEZING INDEXAN ESTIMATE OF THE 100-YEAR RETURN PERIOD
94 FIGURE R403.3(3) INSULATION PLACEMENT FOR FROST-PROTECTED FOOTINGS
95 FIGURE R403.3(4) INSULATION PLACEMENT FOR FROST-PROTECTED FOOTINGS ADJACENT TO HEATED STRUCTURE
96 SECTION R404 FOUNDATION AND RETAINING WALLS
97 TABLE R404.1(1) TOP REACTIONS AND PRESCRIPTIVE SUPPORT FOR FOUNDATION WALLSa
98 TABLE R404.1(2) MAXIMUM PLATE ANCHOR-BOLT SPACING FOR SUPPORTED FOUNDATION WALL
TABLE R404.1.1(1) PLAIN MASONRY FOUNDATION WALLS
99 TABLE R404.1.1(2) 8-INCH MASONRY FOUNDATION WALLS WITH REINFORCING WHERE d > 5 INCHESa
100 TABLE R404.1.1(3) 10-INCH MASONRY FOUNDATION WALLS WITH REINFORCING WHERE d > 6.75 INCHESa
101 TABLE R404.1.1(4) 12-INCH MASONRY FOUNDATION WALLS WITH REINFORCING WHERE d > 8.75 INCHES
102 TABLE R404.1.1(5) CONCRETE FOUNDATION WALLSh, i, j, k
103 TABLE R404.1.1(5) —continued CONCRETE FOUNDATION WALLSh, I, j, k
104 TABLE R404.1.1(7) CANTILEVERED CONCRETE AND MASONRY FOUNDATION WALLS
105 TABLE R404.1.1(8) CANTILEVERED CONCRETE AND MASONRY FOUNDATION WALLS
107 FIGURE R404.1.5(1) FOUNDATION WALL CLAY MASONRY CURTAIN WALL WITH CONCRETE MASONRY PIERS
108 TABLE R404.2.3 PLYWOOD GRADE AND THICKNESS FOR WOOD FOUNDATION CONSTRUCTION(30 pcf equivalent-fluid weight soil pressure)
109 TABLE R404.4(1) 5.5-INCH THICK FLAT ICF FOUNDATION WALLSa, b, c, d
110 TABLE R404.4(2) 7.5-INCH-THICK FLAT ICF FOUNDATION WALLSa, b, c, d, e
111 TABLE R404.4(3) 9.5-INCH-THICK FLAT ICF FOUNDATION WALLSa, b, c, d, e
112 TABLE R404.4(4) WAFFLE GRID ICF FOUNDATION WALLSa, b, c, d, e
113 TABLE R404.4(5) SCREEN-GRID ICF FOUNDATION WALLSa, b c, d, e
SECTION R405 FOUNDATION DRAINAGE
114 SECTION R406 FOUNDATION WATERPROOFING AND DAMPPROOFING
TABLE R405.1 PROPERTIES OF SOILS CLASSIFIED ACCORDING TO THE UNIFIED SOIL CLASSIFICATION SYSTEM
115 SECTION R407 COLUMNS
SECTION R408 UNDER-FLOOR SPACE
117 CHAPTER 5 FLOORS
SECTION R501 GENERAL
SECTION R502 WOOD FLOOR FRAMING
118 FIGURE R502.2 FLOOR CONSTRUCTION
119 TABLE R502.3.1(1) FLOOR JOIST SPANS FOR COMMON LUMBER SPECIES(Residential sleeping areas, live load = 30 psf, L/ = 360)a
120 TABLE R502.3.1(2) FLOOR JOIST SPANS FOR COMMON LUMBER SPECIES(Residential living areas, live load = 40 psf, L/ = 360)b
121 TABLE R502.3.3(1) CANTILEVER SPANS FOR FLOOR JOISTS SUPPORTING LIGHT-FRAME EXTERIOR BEARING WALL AND ROOF ONLYa, b, c, f, g, h(Floor Live Load 40 psf, Roof Live Load 20 psf)
TABLE R502.3.3(2) CANTILEVER SPANS FOR FLOOR JOISTS SUPPORTING EXTERIOR BALCONYa, b, e, f
122 TABLE R502.5(1) GIRDER SPANSa AND HEADER SPANSa FOR EXTERIOR BEARING WALLS(Maximum spans for Douglas fir-larch, hem-fir, southern pine and spruce-pine-firb and required number of jack studs)
123 TABLE R502.5(1) — continued GIRDER SPANSa AND HEADER SPANSa FOR EXTERIOR BEARING WALLS(Maximum spans for Douglas fir-larch, hem-fir, southern pine and spruce-pine-firb and required number of jack studs)
124 TABLE R502.5(2) GIRDER SPANSa AND HEADER SPANSa FOR INTERIOR BEARING WALLS(Maximum spans for Douglas fir-larch, hem-fir, southern pine and spruce-pine-firb and required number of jack studs)
125 FIGURE R502.8 CUTTING, NOTCHING AND DRILLING
126 SECTION R503 FLOOR SHEATHING
TABLE R503.1 MINIMUM THICKNESS OF LUMBER FLOOR SHEATHING
127 TABLE R503.2.1.1(1) ALLOWABLE SPANS AND LOADS FOR WOOD STRUCTURAL PANELS FOR ROOF AND SUBFLOOR SHEATHING AND COMBINATION SUBFLOOR UNDERLAYMENTa, b, c
128 TABLE R503.2.1.1(2) ALLOWABLE SPANS FOR SANDED PLYWOOD COMBINATION SUBFLOOR UNDERLAYMENTa
SECTION R504 PRESSURE PRESERVATIVELY TREATED-WOODFLOORS (ON GROUND)
SECTION R505 STEEL FLOOR FRAMING
129 TABLE R505.2(1) COLD-FORMED STEEL JOIST SIZES
TABLE R505.2(2) MINIMUM THICKNESS OF COLD-FORMED STEEL MEMBERS
130 FIGURE R505.2(3) FLOOR JOIST WEB HOLES
131 TABLE R505.2.4 SCREW SUBSTITUTION FACTOR
FIGURE R505.3 STEEL FLOOR CONSTRUCTION
132 FIGURE R505.3 — continued STEEL FLOOR CONSTRUCTION
133 TABLE R505.3.1(1) FLOOR TO FOUNDATION OR BEARING WALL CONNECTION REQUIREMENTS a, b
TABLE R505.3.1(2) FLOOR FASTENING SCHEDULEa
134 FIGURE R505.3.1(1) FLOOR TO LOAD-BEARING WALL STUD CONNECTION
FIGURE R505.3.1(2) FLOOR TO WOOD SILL CONNECTION
135 FIGURE R505.3.1(3) FLOOR TO FOUNDATION CONNECTION
FIGURE R505.3.1(4) FLOOR CANTILEVER TO LOAD-BEARING WALL CONNECTION
136 FIGURE R505.3.1(5) FLOOR CANTILEVER TO WOOD SILL CONNECTION
FIGURE R505.3.1(6) FLOOR CANTILEVER TO FOUNDATION CONNECTION
137 FIGURE R505.3.1(7) CONTINUOUS JOIST SPAN SUPPORTED ON STUD
FIGURE R505.3.1(8) LAPPED JOISTS SUPPORTED ON STUD
138 TABLE R505.3.2(1) ALLOWABLE SPANS FOR COLD-FORMED STEEL JOISTS—SINGLE SPANSa, b 33 ksi STEEL
FIGURE R505.3.4 BEARING STIFFENER
139 TABLE R505.3.2(2) ALLOWABLE SPANS FOR COLD-FORMED STEEL JOISTS—MULTIPLE SPANSa, b 33 ksi STEEL
FIGURE R505.3.6 HOLE PATCH
140 TABLE R505.3.2(3) ALLOWABLE SPANS FOR COLD-FORMED STEEL JOISTS—MULTIPLE SPANSa, b 50 ksi STEEL
FIGURE R505.3.8 TRACK SPLICE
141 SECTION R506 CONCRETE FLOORS (ON GROUND)
143 CHAPTER 6 WALL CONSTRUCTION
SECTION R601 GENERAL
SECTION R602 WOOD WALL FRAMING
144 TABLE R602.3(1) FASTENER SCHEDULE FOR STRUCTURAL MEMBERS
145 TABLE R602.3(1)—continued FASTENER SCHEDULE FOR STRUCTURAL MEMBERS
146 TABLE R602.3(2) ALTERNATE ATTACHMENTS
147 TABLE R602.3(3) WOOD STRUCTURAL PANEL WALL SHEATHING
TABLE R602.3(4) ALLOWABLE SPANS FOR PARTICLEBOARD WALL SHEATHINGa
TABLE R602.3(5) SIZE, HEIGHT AND SPACING OF WOOD STUDSa
148 FIGURE R602.3(1) TYPICAL WALL, FLOOR AND ROOF FRAMING
149 FIGURE R602.3(2) FRAMING DETAILS
150 TABLE R602.3.1 MAXIMUM ALLOWABLE LENGTH OF WOOD WALL STUDS EXPOSED TO WIND SPEEDS OF 90 MPH OR LESSb,c,d,e,f,g,h,iWhere conditions are not within the parameters of footnotes b, c, d, e, f, g, h, and i, design is required.
151 TABLE R602.3.1 MAXIMUM ALLOWABLE LENGTH OF WOOD WALL STUDS EXPOSED TO WIND SPEEDS OF 90 MPH OR LESSb,c,d,e,f,g,h,iWhere conditions are not within the parameters of footnotes b, c, d, e, f, g, h, and i, design is required.
152 FIGURE R602.6(1) NOTCHING AND BORED HOLE LIMITATIONS FOR EXTERIOR WALLS AND BEARING WALLS
FIGURE R602.6(2) NOTCHING AND BORED HOLE LIMITATIONS FOR INTERIOR NONBEARING WALLS
153 FIGURE R602.6.1 TOP PLATE FRAMING TO ACCOMMODATE PIPING
TABLE R602.7.2 MAXIMUM SPANS FOR WOOD STRUCTURAL PANEL BOX HEADERSa
154 FIGURE R602.7.2 TYPICAL WOOD STRUCTURAL PANEL BOX HEADER CONSTRUCTION
156 TABLE R602.10.1 WALL BRACING
157 TABLE R602.10.5 LENGTH REQUIREMENTS FOR BRACED WALL PANELS IN A CONTINUOUSLY SHEATHED WALLa, b, c
158 FIGURE R602.10.5 TYPICAL EXTERIOR CORNER FRAMING FOR CONTINUOUS STRUCTURAL PANEL SHEATHING; SHOWING REQUIRED STUD-TO-STUD NAILING
TABLE R602.10.6 MINIMUM WIDTHS AND TIE-DOWN FORCES OF ALTERNATE BRACED WALL PANELS
159 FIGURE R602.10.6.2 ALTERNATE BRACED WALL PANEL ADJACENT TO A DOOR OR WINDOW OPENING
161 FIGURE R602.11.3 STEPPED FOUNDATION CONSTRUCTION
SECTION R603 STEEL WALL FRAMING
162 TABLE R603.2(1) LOAD-BEARING COLD-FORMED STEEL STUD SIZES
TABLE R603.2(2) MINIMUM THICKNESS OF COLD-FORMED STEEL STUDS
FIGURE R603.2(1) C-SECTION
FIGURE R603.2(2) TRACK SECTION
163 FIGURE R603.2(3) WEB HOLES
TABLE R603.2.4 SCREW SUBSTITUTION FACTOR
164 FIGURE R603.3 STEEL WALL CONSTRUCTION
TABLE R603.3.1 WALL TO FOUNDATION OR FLOOR CONNECTION REQUIREMENTSa,b,c
165 FIGURE R603.3.1(1) WALL TO FOUNDATION CONNECTION
FIGURE R603.3.1(2) WALL TO WOOD SILL CONNECTION
TABLE R603.3.2(1) WALL FASTENING SCHEDULE
166 TABLE R603.3.2(2) 24-FOOT-WIDE BUILDING SUPPORTING ROOF AND CEILING ONLYa, b, c33 ksi STEE
167 TABLE R603.3.2(3) 24-FOOT-WIDE BUILDING SUPPORTING ROOF AND CEILING ONLYa, b, c50 ksi STEEL
168 TABLE R603.3.2(4) 28-FOOT-WIDE BUILDING SUPPORTING ROOF AND CEILING ONLYa, b, c33 ksi STEEL
169 TABLE R603.3.2(5) 28-FOOT-WIDE BUILDING SUPPORTING ROOF AND CEILING ONLYa, b, c50 ksi STEEL
170 TABLE R603.3.2(6) 32-FOOT-WIDE BUILDING SUPPORTING ROOF AND CEILING ONLYa, b, c33 ksi STEEL
171 TABLE R603.3.2(7) 32-FOOT-WIDE BUILDING SUPPORTING ROOF AND CEILING ONLYa, b, c50 ksi STEEL
172 TABLE R603.3.2(8) 36-FOOT-WIDE BUILDING SUPPORTING ROOF AND CEILING ONLYa, b, c33 ksi STEEL
173 TABLE R603.3.2(9) 36-FOOT-WIDE BUILDING SUPPORTING ROOF AND CEILING ONLYa, b, c50 ksi STEEL
174 TABLE R603.3.2(10) 40-FOOT-WIDE BUILDING SUPPORTING ROOF AND CEILING ONLYa, b, c33 ksi STEEL
175 TABLE R603.3.2(11) 40-FOOT-WIDE BUILDING SUPPORTING ROOF AND CEILING ONLYa, b, c50 ksi STEEL
176 TABLE R603.3.2(12) 24-FOOT-WIDE BUILDING SUPPORTING ONE FLOOR, ROOF AND CEILINGa, b, c33 ksi STEEL
177 TABLE R603.3.2(13) 24-FOOT-WIDE BUILDING SUPPORTING ONE FLOOR, ROOF AND CEILINGa, b, c50 ksi STEEL
178 TABLE R603.3.2(14) 28-FOOT-WIDE BUILDING SUPPORTING ONE FLOOR, ROOF AND CEILINGa, b, c33 ksi STEEL
179 TABLE R603.3.2(15) 28-FOOT-WIDE BUILDING SUPPORTING ONE FLOOR, ROOF AND CEILINGa, b, c50 ksi STEEL
180 TABLE R603.3.2(16) 32-FOOT-WIDE BUILDING SUPPORTING ONE FLOOR, ROOF AND CEILINGa, b, c33 ksi STEEL
181 TABLE R603.3.2(17) 32-FOOT-WIDE BUILDING SUPPORTING ONE FLOOR, ROOF AND CEILINGa, b, c50 ksi STEEL
182 TABLE R603.3.2(18) 36-FOOT-WIDE BUILDING SUPPORTING ONE FLOOR, ROOF AND CEILINGa, b, c33 ksi STEEL
183 TABLE R603.3.2(19) 36-FOOT-WIDE BUILDING SUPPORTING ONE FLOOR, ROOF AND CEILINGa, b, c50 ksi STEEL
184 TABLE R603.3.2(20) 40-FOOT-WIDE BUILDING SUPPORTING ONE FLOOR, ROOF AND CEILINGa, b, c33 ksi STEEL
185 TABLE R603.3.2(21) 40-FOOT-WIDE BUILDING SUPPORTING ONE FLOOR, ROOF AND CEILINGa, b, c50 ksi STEEL
186 FIGURE R603.3.5 HOLE PATCH
187 TABLE R603.6(1) BOX-BEAM HEADER SPANS Headers supporting roof and ceiling only (33 ksi steel)a, b, c
188 TABLE R603.6(2) BOX-BEAM HEADER SPANS Headers supporting roof and ceiling only (33 ksi steel)a, b, c
189 TABLE R603.6(3) BOX-BEAM HEADER SPANS Headers supporting one floor, roof and ceiling (33 ksi steel)a, b, c
190 TABLE R603.6(4) BOX-BEAM HEADER SPANS Headers supporting one floor, roof and ceiling (33 ksi steel)a, b, c
191 TABLE R603.6(5) BACK-TO-BACK HEADER SPANS Headers supporting roof and ceiling only (33 ksi steel)a, b, c
192 TABLE R603.6(6) BACK-TO-BACK HEADER SPANS Headers supporting roof and ceiling only (33 ksi steel)a, b, c
193 TABLE R603.6(7) BACK-TO-BACK HEADER SPANS Headers supporting one floor, roof and ceiling (33 ksi steel)a, b, c
194 TABLE R603.6(8) BACK-TO-BACK HEADER SPANS Headers supporting one floor, roof and ceiling (33 ksi steel)a, b, c
195 TABLE R603.6(9) TOTAL NUMBER OF JACK AND KING STUDS REQUIRED AT EACH END OF AN OPENING
TABLE R603.6(10) HEADER TO KING STUD CONNECTION REQUIREMENTSa, b, c, d
TABLE R603.6(11) HEAD TRACK SPAN (33 ksi Steel)
196 FIGURE R603.6 HEADER DETAIL
197 TABLE R603.7MINIMUM PERCENTAGE OF FULL HEIGHT STRUCTURAL SHEATHING ON EXTERIOR WALLSa, b, c, d, e
SECTION R604 WOOD STRUCTURAL PANELS
SECTION R605 PARTICLEBOARD
SECTION R606 GENERAL MASONRY CONSTRUCTION
198 TABLE R606.5 ALLOWABLE COMPRESSIVE STRESSES FOREMPIRICAL DESIGN OF MASONRY
199 TABLE R606.9 SPACING OF LATERAL SUPPORT FOR MASONRY WALLS
200 FIGURE R606.11(1) ANCHORAGE REQUIREMENTS FOR MASONRY WALLS LOCATED IN SEISMIC DESIGN CATEGORYA, B OR C AND WHERE WIND LOADS ARE LESS THAN 30 PSF
201 FIGURE R606.11(2) REQUIREMENTS FOR REINFORCED GROUTED MASONRY CONSTRUCTION IN SEISMIC DESIGN CATEGORY C
202 FIGURE R606.11(3) REQUIREMENTS FOR REINFORCED MASONRY CONSTRUCTION IN SEISMIC DESIGN CATEGORY D0, D1 OR D2
204 TABLE R606.12.3.2 MINIMUM DISTRIBUTED WALL REINFORCEMENT FOR BUILDING ASSIGNED TO SEISMIC DESIGN CATEGORY D0 or D1
TABLE R606.12.4.1 MINIMUM REINFORCING FOR STACKED BONDED MASONRY WALLS IN SEISMIC DESIGN CATEGORY D2
205 TABLE R606.12.4.2 MINIMUM REINFORCING FOR STACKED BONDED MASONRY WALLS IN SEISMIC DESIGN CATEGORY D
TABLE R606.15.1 MINIMUM CORROSION PROTECTION
SECTION R607 UNIT MASONRY
206 TABLE R607.1 MORTAR PROPORTIONSa, b
SECTION R608 MULTIPLE WYTHE MASONRY
207 SECTION R609 GROUTED MASONRY
TABLE R609.1.1 GROUT PROPORTIONS BY VOLUME FOR MASONRY CONSTRUCTION
208 TABLE R609.1.2 GROUT SPACE DIMENSIONS AND POUR HEIGHTS
209 SECTION R610 GLASS UNIT MASONRY
FIGURE R610.4.1 GLASS UNIT MASONRY DESIGN WIND LOAD RESISTANCE
210 SECTION R611 INSULATING CONCRETE FORMWALL CONSTRUCTION
211 TABLE R611.2 REQUIREMENTS FOR ICF WALLSb
FIGURE R611.3 FLAT ICF WALL SYSTEM
212 TABLE R611.3(1) DESIGN WIND PRESSURE FOR USE WITH TABLES R611.3(2), R611.4(1), AND R611.5 FOR ABOVE GRADE WALLSa
213 TABLE R611.3(2) MINIMUM VERTICAL WALL REINFORCEMENT FOR FLAT ICF ABOVE-GRADE WALLSa, b, c, d
214 TABLE R611.4(1) MINIMUM VERTICAL WALL REINFORCEMENT FOR WAFFLE-GRID ICF ABOVE-GRADE WALLSa, b, c
FIGURE R611.4 WAFFLE-GRID ICF WALL SYSTEM
215 TABLE R611.5 MINIMUM VERTICAL WALL REINFORCEMENT FOR SCREEN-GRID ICF ABOVE-GRADE WALLSa, b, c
FIGURE R611.5 SCREEN-GRID IFC WALL SYSTEM
216 TABLE R611.7(1) MINIMUM WALL OPENING REINFORCEMENT REQUIREMENTS IN ICF WALLSa
FIGURE R611.7(1) ICF WALL CONSTRUCTION
TABLE R611.7(1) MINIMUM WALL OPENING REINFORCEMENT REQUIREMENTS IN ICF WALLSa
FIGURE R611.7(1) ICF WALL CONSTRUCTION
217 TABLE R611.7(2) MAXIMUM ALLOWABLE CLEAR SPANS FOR ICF LINTELS FOR FLAT LOAD-BEARING WALLSa, b, c, d, fNO. 4 BOTTOM BAR SIZE
218 TABLE R611.7(3) MAXIMUM ALLOWABLE CLEAR SPANS FOR ICF LINTELS FOR FLAT LOAD-BEARING WALLSa, b, c, d, fNO. 5 BOTTOM BAR SIZE
219 TABLE R611.7(4) MAXIMUM ALLOWABLE CLEAR SPANS FOR WAFFLE-GRID ICF WALL LINTELSa, b, c, d, fNO. 4 BOTTOM BAR SIZE
220 TABLE R611.7(5) MAXIMUM ALLOWABLE CLEAR SPANS FOR WAFFLE-GRID ICF WALL LINTELSa, b, c, d, fNO. 5 BOTTOM BAR SIZE
221 TABLE R611.7(6) MAXIMUM ALLOWABLE CLEAR SPANS FOR SCREEN-GRID ICF LINTELS IN LOAD-BEARING WALLSa, b, c, d,e, f, gNO. 4 BOTTOM BAR SIZE
TABLE R611.7(7) MAXIMUM ALLOWABLE CLEAR SPANS FOR SCREEN-GRID ICF LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, gNO. 5 BOTTOM BAR SIZE
222 TABLE R611.7(8) MAXIMUM ALLOWABLE CLEAR SPANS FOR ICF LINTELS WITHOUT STIRRUPS IN LOAD-BEARING WALLSa, b, c, d, e, f, g, h(NO. 4 OR NO. 5) BOTTOM BAR SIZE
223 TABLE R611.7(9) MINIMUM BOTTOM BAR ICF LINTEL REINFORCEMENT FOR LARGE CLEAR SPANS IN LOAD-BEARING WALLSa, b, c, d, e, f, h
224 TABLE R611.7(9A) MINIMUM SOLID END WALL LENGTH REQUIREMENTS FOR FLAT ICF WALLS (WIND PERPENDICULAR TO RIDGE)a, b, c
225 TABLE R611.7(9B) MINIMUM SOLID SIDEWALL LENGTH REQUIREMENTS FOR FLAT ICF WALLS (WIND PARALLEL TO RIDGE) a, b, c, d
226 TABLE R611.7(10) MAXIMUM ALLOWABLE CLEAR SPANS FOR ICF LINTELS IN NONLOAD-BEARING WALLS WITHOUT STIRRUPSa,b,c,d NO. 4 BOTTOM BAR
227 TABLE R611.7(10A) MINIMUM SOLID END WALL LENGTH REQUIREMENTS FOR WAFFLE ANDSCREEN-GRID ICF WALLS (WIND PERPENDICULAR TO RIDGE)a, b
228 TABLE R611.7(10A) —continued MINIMUM SOLID END WALL LENGTH REQUIREMENTS FOR WAFFLE ANDSCREEN-GRID ICF WALLS (WIND PERPENDICULAR TO RIDGE)a, b,
TABLE R611.7(10B) MINIMUM SOLID SIDE WALL LENGTH REQUIREMENTS FOR 6-INCH WAFFLE ANDSCREEN-GRID ICF WALLS (WIND PARALLEL TO RIDGE)a, b, c, d
229 TABLE R611.7(11) MINIMUM PERCENTAGE OF SOLID WALL LENGTH ALONG EXTERIOR WALL LINES FOR TOWNHOUSES IN SEISMIC DESIGNCATEGORY C AND ALL BUILDINGS IN SEISMIC DESIGN CATEGORIES D0, D1 AND D2a, b
FIGURE R611.7.1.4 LAP SPLICES
230 FIGURE R611.7(2) REINFORCEMENT OF OPERNINGS
FIGURE R611.7(3) ICF LINTELS FOR FLAT AND SCREEN-GRID WALLS
231 FIGURE R611.7(4) SINGLE FORM HEIGHT WAFFLE-GRID LINTEL
FIGURE R611.7(5) DOUBLE FORM HEIGHT WAFFLE-GRID LINTEL
232 FIGURE R611.7(6) SINGLE FORM HEIGHT SCREEN-GRID LINTEL
FIGURE R611.7(7) DOUBLE FORM HEIGHT SCREEN-GRID LINTEL
233 TABLE R611.7.4 WIND VELOCITY PRESSURE FOR DETERMINATION OFMINIMUM SOLID WALL LENGTHa
234 FIGURE R611.7.4 MINIMUM SOLID WALL LENGTH
235 TABLE R611.8(1) FLOOR LEDGER-ICF WALL CONNECTION (SIDE-BEARING CONNECTION) REQUIREMENTSa,
TABLE R611.8(2) DESIGN VALUES (PLF) FOR FLOOR JOIST-TO-WALL ANCHORS REQUIRED FOR TOWNHOUSESIN SEISMIC DESIGN CATEGORY C AND ALL BUILDINGS IN SEISMIC DESIGN CATEGORIES D0, D1 AND D2a, b
236 FIGURE R611.8(1) SECTION CUT THROUGH FLAT WALL OR VERTICAL CORE OF WAFFLE- OR SCREEN-GRID WAL
237 FIGURE R611.8(2) FLOOR LEDGER—ICF WALL CONNECTION (SIDE-BEARING CONNECTION)
FIGURE R611.8(3) FLOOR LEDGER—ICF WALL CONNECTION (LEDGE-BEARING CONNECTION)
238 FIGURE R611.8(4) WOOD FLOOR LEDGER—ICF WALL SYSTEM CONNECTION(THROUGH-BOLT SIDE-BEARING CONNECTION)
FIGURE R611.8(5) FLOOR LEDGER—ICF WALL CONNECTION
239 FIGURE R611.8(6) ANCHORAGE REQUIREMENTS FOR TOP BEARING WALLS FOR TOWNHOUSES IN SEISMIC DESIGN CATEGORY CAND ALL BUILDINGS IN SEISMIC DESIGN CATEGORIES D0, D1, AND D2 FOR FLOOR FRAMING PARALLEL TO WALL
FIGURE R611.8(7) ANCHORAGE REQUIREMENTS FOR LEDGER BEARING WALLS FOR TOWNHOUSES IN SEISMIC DESIGN CATEGORY C AND ALLBUILDINGS IN SEISMIC DESIGN CATEGORIES D0, D1 AND D2 FOR FLOOR FRAMING PARALLEL TO WALL
240 TABLE R611.9 DESIGN TENSILE STRENGTH OF HEADED BOLTS CAST IN CONCRETEa
FIGURE R611.9 ROOF SILL PLATE—ICF WALL CONNECTION
241 SECTION R612 CONVENTIONALLY FORMED CONCRETE WALLCONSTRUCTION
SECTION R613 EXTERIOR WINDOWS AND GLASS DOORS
242 FIGURE R613.8(1)THROUGH THE FRAME
FIGURE R613.8(2) FRAME CLIP
FIGURE R613.8(3) THROUGH THE FRAME
FIGURE R613.8(4) FRAME CLIP
243 FIGURE R613.8(5) THROUGH THE FLANGE
FIGURE R613.8(6) THROUGH THE FRAME
FIGURE R613.8(7) FRAME CLIP
FIGURE R613.8(8) THROUGH THE FLANGE
245 CHAPTER 7 WALL COVERING
SECTION R701 GENERAL
SECTION R702 INTERIOR COVERING
TABLE R702.1(1) THICKNESS OF PLASTER
TABLE R702.1(2) GYPSUM PLASTER PROPORTIONSa
246 TABLE R702.1(3) PORTLAND CEMENT PLASTER
247 TABLE R702.3.5 MINIMUM THICKNESS AND APPLICATION OF GYPSUM BOARD
248 TABLE R702.3.7 SHEAR CAPACITY FOR HORIZONTAL WOOD-FRAMEDGYPSUM BOARD DIAPHRAGM CEILING ASSEMBLIES
SECTION R703 EXTERIOR COVERING
250 TABLE R703.4 WEATHER–RESISTANT SIDING ATTACHMENT AND MINIMUM THICKNESS
251 TABLE R703.5.2 MAXIMUM WEATHER EXPOSURE FOR WOOD SHAKES AND SHINGLES ON EXTERIOR WALLSa,b,c(Dimensions are in inches)
253 FIGURE R703.7 MASONRY VENEER WALL DETAILS
254 FIGURE R703.7—continued MASONRY VENEER WALL DETAILS
255 TABLE R703.7(1) STONE OR MASONRY VENEER LIMITATIONS AND REQUIREMENTS, WOODOR STEEL FRAMING, SEISMIC DESIGN CATEGORIES A, B AND C
TABLE R703.7.3 ALLOWABLE SPANS FOR LINTELS SUPPORTING MASONRY VENEERa, b
256 TABLE R703.7(2) STONE OR MASONRY VENEER LIMITATIONS AND REQUIREMENTS, ONE- AND TWO-FAMILY DETACHED DWELLINGS, WOODFRAMING, SEISMIC DESIGN CATEGORIES D0, D1 AND D2
257 FIGURE R703.7(1) HOLD DOWNS AT EXTERIOR AND INTERIOR BRACED WALL PANELS WHEN USING STONE OR MASONRY VENEE
258 FIGURE R703.7.2.2 EXTERIOR MASONRY VENEER SUPPORT BY ROOF MEMBERS
261 CHAPTER 8 ROOF-CEILING CONSTRUCTION
SECTION R801 GENERAL
SECTION R802 WOOD ROOF FRAMING
264 TABLE R802.4(1) CEILING JOIST SPANS FOR COMMON LUMBER SPECIES(Uninhabitable attics without storage, live load = 10 psf, L/ = 240)
265 TABLE R802.4(1)—continued CEILING JOIST SPANS FOR COMMON LUMBER SPECIES(Uninhabitable attics without storage, live load = 10 psf, L/ = 240)
266 TABLE R802.4(2) CEILING JOIST SPANS FOR COMMON LUMBER SPECIES(Uninhabitable attics with limited storage, live load = 20 psf, L/ = 240)
267 TABLE R802.4(2) —continued CEILING JOIST SPANS FOR COMMON LUMBER SPECIES(Uninhabitable attics with limited storage, live load = 20 psf, L/ = 240)
268 TABLE R802.5.1(1) RAFTER SPANS FOR COMMON LUMBER SPECIES(Roof live load=20 psf, ceiling not attached to rafters, L/ = 180)
269 TABLE R802.5.1(1) —continued RAFTER SPANS FOR COMMON LUMBER SPECIES(Roof live load=20 psf, ceiling not attached to rafters, L/ = 180)
270 TABLE R802.5.1(2) RAFTER SPANS FOR COMMON LUMBER SPECIES(Roof live load=20 psf, ceiling attached to rafters, L/ = 240)
271 TABLE R802.5.1(2) —continued RAFTER SPANS FOR COMMON LUMBER SPECIES(Roof live load=20 psf, ceiling attached to rafters, L/ = 240)
272 TABLE R802.5.1(3) RAFTER SPANS FOR COMMON LUMBER SPECIES(Ground snow load=30 psf, ceiling not attached to rafters, L/ = 180)
273 TABLE R802.5.1(3) —continued RAFTER SPANS FOR COMMON LUMBER SPECIES(Ground snow load=30 psf, ceiling not attached to rafters, L/ = 180)
274 TABLE R802.5.1(4) RAFTER SPANS FOR COMMON LUMBER SPECIES(Ground snow load=50 psf, ceiling not attached to rafters, L/ = 180)
275 TABLE R802.5.1(4) —continued RAFTER SPANS FOR COMMON LUMBER SPECIES(Ground snow load=50 psf, ceiling not attached to rafters, L/ = 180)
276 TABLE R802.5.1(5) RAFTER SPANS FOR COMMON LUMBER SPECIES(Ground snow load=30 psf, ceiling attached to rafters, L/ = 240)
277 TABLE R802.5.1(5) —continued RAFTER SPANS FOR COMMON LUMBER SPECIES(Ground snow load=30 psf, ceiling attached to rafters, L/ = 240)
278 TABLE R802.5.1(6) RAFTER SPANS FOR COMMON LUMBER SPECIES(Ground snow load=50 psf, ceiling attached to rafters, L/ = 240)
279 TABLE R802.5.1(6) —continued RAFTER SPANS FOR COMMON LUMBER SPECIES(Ground snow load=50 psf, ceiling attached to rafters, L/ = 240)
280 TABLE R802.5.1(7) RAFTER SPANS FOR 70 PSF GROUND SNOW LOAD(Ceiling not attached to rafters, L/ = 180)
281 TABLE R802.5.1(7) —continued RAFTER SPANS FOR 70 PSF GROUND SNOW LOAD (Ceiling not attached to rafters, L/ = 180)
282 TABLE R802.5.1(8) RAFTER SPANS FOR 70 PSF GROUND SNOW LOAD (Ceiling attached to rafters, L/ = 240)
283 TABLE R802.5.1(8) —continued RAFTER SPANS FOR 70 PSF GROUND SNOW LOADa(Ceiling attached to rafters, L/ = 240)
284 TABLE R802.5.1(9) RAFTER/CEILING JOIST HEEL JOINT CONNECTIONSa, b, c, d, e, f, g
285 FIGURE R802.5.1 BRACED RAFTER CONSTRUCTION
286 TABLE R802.11 REQUIRED STRENGTH OF TRUSS OR RAFTER CONNECTIONS TO RESIST WIND UPLIFT FORCESa, b, c, e, f (Pounds per connection
SECTION R803 ROOF SHEATHING
TABLE R803.1 MINIMUM THICKNESS OF LUMBER ROOF SHEATHING
SECTION R804 STEEL ROOF FRAMING
287 TABLE R804.2(1) LOAD-BEARING COLD-FORMED STEEL MEMBER SIZES
TABLE R804.2(2) MINIMUM THICKNESS OF COLD-FORMED STEEL ROOF FRAMING MEMBERS
288 TABLE R804.2.4 SCREW SUBSTITUTION FACTOR
FIGURE R804.2(3) WEB HOLES
289 TABLE R804.3 ROOF FRAMING FASTENING SCHEDULEa,b
FIGURE R804.3 STEEL ROOF CONSTRUCTION
290 TABLE R804.3.1(1) CEILING JOIST SPANS SINGLE SPANS WITH BEARING STIFFENERS10 lb per sq ft LIVE LOAD (NO ATTIC STORAGE)a, b, c 33 ksi STEEL
291 TABLE R804.3.1(2) CEILING JOIST SPANSTWO EQUAL SPANS WITH BEARING STIFFENERS10 lb per sq ft LIVE LOAD (NO ATTIC STORAGE)a, b, c 33 ksi STEEL
292 TABLE R804.3.1(3) CEILING JOIST SPANSSINGLE SPANS WITH BEARING STIFFENERS20 lb per sq ft LIVE LOAD (LIMITED ATTIC STORAGE)a, b, c 33 ksi STEEL
293 TABLE R804.3.1(4) CEILING JOIST SPANSTWO EQUAL SPANS WITH BEARING STIFFENERS20 lb per sq ft LIVE LOAD (LIMITED ATTIC STORAGE)a, b, c 33 ksi STEEL
294 TABLE R804.3.1(5) CEILING JOIST SPANSSINGLE SPANS WITHOUT BEARING STIFFENERS10 lb per sq ft LIVE LOAD (NO ATTIC STORAGE)a, b 33 ksi STEEL
295 TABLE R804.3.1(6) CEILING JOIST SPANSTWO EQUAL SPANS WITHOUT BEARING STIFFENERS10 lb per sq ft LIVE LOAD (NO ATTIC STORAGE)a, b 33 ksi STEEL
296 TABLE R804.3.1(7) CEILING JOIST SPANSSINGLE SPANS WITHOUT BEARING STIFFENERS20 lb per sq ft LIVE LOAD (LIMITED ATTIC STORAGE)a, b 33 ksi STEEL
297 TABLE R804.3.1(8) CEILING JOIST SPANSTWO EQUAL SPANS WITHOUT BEARING STIFFENERS20 lb per sq ft LIVE LOAD (LIMITED ATTIC STORAGE)a, b 33 ksi STEEL
298 FIGURE R804.3.1(1) JOIST TO RAFTER CONNECTION
TABLE R804.3.1 NUMBER OF SCREWS REQUIRED FOR CEILING JOIST TO RAFTER CONNECTIONa
299 TABLE R804.3.3(1) ALLOWABLE HORIZONTAL RAFTER SPANSa, b, c 33 ksi STEEL
300 TABLE R804.3.3(2) BASIC WIND SPEED TO EQUIVALENT SNOW LOAD CONVERSION
TABLE R804.3.3.1 NUMBER OF SCREWS REQUIRED AT EACH LEG OF CLIPANGLE FOR RAFTER TO RIDGE MEMBER CONNECTIONa
FIGURE R804.3.3.1 RIDGE BOARD CONNECTION
301 FIGURE R804.3.6 HOLE PATCHING
302 FIGURE R804.3.7(1) SPLICED CEILING JOISTS
FIGURE R804.3.7(2) TRACK SPLICE
303 FIGURE R804.3.8 BEARING STIFFENER
FIGURE R804.3.10(1) ROOF OPENING
304 FIGURE R804.3.10(2) HEADER TO TRIMMER CONNECTION
SECTION R805 CEILING FINISHES
SECTION R806 ROOF VENTILATION
SECTION R807 ATTIC ACCESS
SECTION R808 INSULATION CLEARANCE
305 CHAPTER 9 ROOF ASSEMBLIES
SECTION R901 GENERAL
SECTION R902 ROOF CLASSIFICATION
SECTION R903 WEATHER PROTECTION
SECTION R904 MATERIALS
306 FIGURE R903.5 HAIL EXPOSURE MAP
307 SECTION R905 REQUIREMENTS FOR ROOF COVERINGS
308 TABLE R905.2.8.2 VALLEY LINING MATERIAL
309 TABLE R905.3.7 CLAY AND CONCRETE TILE ATTACHMENT
310 TABLE R905.6.5 SLATE SHINGLE HEADLAP
TABLE R905.7.4 WOOD SHINGLE MATERIAL REQUIREMENTS
311 TABLE R905.7.5 WOOD SHINGLE WEATHER EXPOSURE AND ROOF SLOPE
TABLE R905.8.5 WOOD SHAKE MATERIAL REQUIREMENTS
312 TABLE R905.8.6 WOOD SHAKE WEATHER EXPOSURE AND ROOF SLOPE
313 TABLE R905.9.2 BUILT-UP ROOFING MATERIAL STANDARDS
TABLE R905.10.3(1) METAL ROOF COVERINGS STANDARDS
314 TABLE R905.10.3(2) MINIMUM CORROSION RESISTANCE
TABLE R905.11.2 MODIFIED BITUMEN ROOFING MATERIAL STANDARDS
315 SECTION R906 ROOF INSULATION
TABLE R906.2 MATERIAL STANDARDS FOR ROOF INSULATION
SECTION R907 REROOFING
317 CHAPTER 10 CHIMNEYS AND FIREPLACES
SECTION R1001 MASONRY FIREPLACES
318 TABLE R1001.1 SUMMARY OF REQUIREMENTS FOR MASONRY FIREPLACES AND CHIMNEYS
319 FIGURE R1001.1 FIREPLACE AND CHIMNEY DETAILS
320 FIGURE R1001.11 CLEARANCE FROM COMBUSTIBLES
321 SECTION R1002 MASONRY HEATERS
SECTION R1003 MASONRY CHIMNEYS
323 TABLE R1003.14(1) NET CROSS–SECTIONAL AREA OF ROUND FLUE SIZESa
TABLE R1003.14(2) NET CROSS–SECTIONAL AREA OF SQUARE ANDRECTANGULAR FLUE SIZE
324 FIGURE R1003.15.2 FLUE SIZES FOR MASONRY CHIMNEYS
325 FIGURE R1003.18 CLEARANCE FROM COMBUSTIBLES
TABLE R1003.20 CRICKET DIMENSIONS
SECTION R1004 FACTORY-BUILT FIREPLACES
SECTION R1005 FACTORY-BUILT CHIMNEYS
326 FIGURE R1003.20 CHIMNEY CRICKET
SECTION R1006 EXTERIOR AIR SUPPLY
327 PART IV — ENERGY CONSERVATION
CHAPTER 11 ENERGY
329 PART V — MECHANICAL
CHAPTER 12 MECHANICAL
331 PART VII — PLUMBING
CHAPTER 25 PLUMBING
333 PART VIII — ELECTRICAL
CHAPTER 34 ELECTRICAL
335 Part IX—REFERENCED STANDARDS
CHAPTER 43 REFERENCED STANDARDS
AAMA
ACI
ACCA
AFPA
336 AHA
AISI
AITC
ANSI
337 APA
ASCE
338 ASHRAE
ASME
339 ASSE
ASTM
346 AWS
AWPA
AWWA
CGSB
347 CISPI
CPSC
CSA
348 CSSB
DASMA
DOC
349 DOTn
FEMA
FM
GA
HPVA
ICC
350 ISO
MSS
NAIMA
NCMA
NFPA
351 NFRC
NSF
SAE
SMACNA
TMS
TPI
352 UL
ULC
353 WDMA
355 APPENDIX A SAMPLE ADOPTION ORDINANCES
SAMPLE ADOPTION ORDINANCES
357 SELF-PERPETUATING SAMPLE ORDINANCE – EXAMPLE
358 ACCESSIBILITY ORDINANCE – EXAMPLE
359 APPENDIX B SAMPLE FEE SCHEDULES
363 APPENDIX C GUIDELINES FOR SPECIAL INSPECTIONS AND TESTING
365 APPENDIX D MISCELLANEOUS STATUTES RELATED TOSTATE BUILDING CODE ADMINISTRATION
385 APPENDIX E STATUTORY HOUSING WARRANTIES
389 APPENDIX F DOCUMENT AND AGENCY RESOURCES
393 INDEX
MN ResidentialCode 07 2007
$44.15