Shopping Cart

No products in the cart.

OR MechanicalSpecialtyCode 2022 1stptg

$76.92

Oregon Mechanical Specialty Code

Published By Publication Date Number of Pages
OR 2022
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This is a fully integrated custom code based on the 2021 International Mechanical Code® and 2021 International Fuel Gas Code®. Effective date: October 1, 2022

PDF Catalog

PDF Pages PDF Title
1 2022 OREGON MECHANICAL SPECIALTY CODE
2 2022 OREGON MECHANICAL SPECIALTY CODE BASED ON THE 2021 INTERNATIONAL MECHANICAL CODE® AND THE 2021 INTERNATIONAL FUEL GAS CODE® TITLE PAGE
3 COPYRIGHT
4 PREFACE
6 ARRANGEMENT AND FORMAT OF THE 2022 OMSC
12 TABLE OF CONTENTS
16 CHAPTER 1 SCOPE AND ADMINISTRATION
PART 1—SCOPE AND APPLICATION
SECTION 101 SCOPE AND GENERAL REQUIREMENTS
SECTION 102 APPLICABILITY
18 PART 2—ADMINISTRATION AND ENFORCEMENT
SECTION 103 CODE COMPLIANCE AGENCY
SECTION 104 DUTIES AND POWERS OF THE BUILDING OFFICIAL
SECTION 105 APPROVAL
19 SECTION 106 PERMITS
20 SECTION 107 CONSTRUCTION DOCUMENTS
SECTION 108 NOTICE OF APPROVAL
21 SECTION 109 FEES
22 SECTION 110 SERVICE UTILITIES
SECTION 111 TEMPORARY EQUIPMENT, SYSTEMS AND USES
SECTION 112 INSPECTIONS AND TESTING
23 SECTION 113 MEANS OF APPEALS
24 SECTION 114 RESERVED
SECTION 115 VIOLATIONS
25 SECTION 116 STOP WORK ORDER
26 CHAPTER 2 DEFINITIONS
SECTION 201 GENERAL
SECTION 202 GENERAL DEFINITIONS
40 CHAPTER 3 GENERAL REGULATIONS
SECTION 301 GENERAL
41 SECTION 302 PROTECTION OF STRUCTURE
42 SECTION 303 EQUIPMENT AND APPLIANCE LOCATION
SECTION 304 INSTALLATION
44 FIGURE 304.6 ILLUSTRATIONS OF NORMAL VEHICLE PATH AND RECOMMENDED TYPES OF PROTECTION
45 SECTION 305 PIPING SUPPORT
TABLE 305.4 PIPING SUPPORT SPACINGa
SECTION 306 ACCESS AND SERVICE SPACE
47 SECTION 307 CONDENSATE DISPOSAL
TABLE 307.2.2 CONDENSATE DRAIN SIZING
48 SECTION 308 CLEARANCE REDUCTION
49 TABLE 308.4.2 CLEARANCE REDUCTION METHODSb
SECTION 309 TEMPERATURE CONTROL
50 SECTION 310 HEATING AND COOLING LOAD CALCULATIONS
52 CHAPTER 4 VENTILATION
SECTION 401 GENERAL
TABLE 401.5 OPENING SIZES IN LOUVERS, GRILLES AND SCREENS PROTECTING AIR INTAKE OPENINGS
SECTION 402 NATURAL VENTILATION
53 SECTION 403 MECHANICAL VENTILATION
54 TABLE 403.3.1.1 MINIMUM VENTILATION RATES
55 TABLE 403.3.1.1—continued MINIMUM VENTILATION RATES
56 TABLE 403.3.1.1—continued MINIMUM VENTILATION RATES
57 EQUATION 4-1
TABLE 403.3.1.1.1.2 ZONE AIR DISTRIBUTION EFFECTIVENESS
EQUATION 4-2
EQUATION 4-3
EQUATION 4-4
EQUATION 4-5
58 TABLE 403.3.1.1.2.3.2 SYSTEM VENTILATION EFFICIENCY
EQUATION 4-6
EQUATION 4-7
EQUATION 4-8
EQUATION 4-9
59 TABLE 403.3.2.3 MINIMUM REQUIRED LOCAL EXHAUST RATES FOR GROUP R-2, R-3 AND R-4 OCCUPANCIES
SECTION 404 ENCLOSED PARKING GARAGES
SECTION 405 SYSTEMS CONTROL
SECTION 406 VENTILATION OF UNINHABITED SPACES
SECTION 407 AMBULATORY CARE FACILITIES AND GROUP I-2 OCCUPANCIES
60 CHAPTER 5 EXHAUST SYSTEMS
SECTION 501 GENERAL
61 SECTION 502 REQUIRED SYSTEMS
EQUATION 5-1
67 SECTION 503 MOTORS AND FANS
68 SECTION 504 CLOTHES DRYER EXHAUST
69 TABLE 504.9.4.1 DRYER EXHAUST DUCT FITTING EQUIVALENT LENGTH
SECTION 505 DOMESTIC COOKING EXHAUST EQUIPMENT
70 SECTION 506 COMMERCIAL KITCHEN HOOD VENTILATION SYSTEM DUCTS AND EXHAUST EQUIPMENT
75 SECTION 507 COMMERCIAL KITCHEN HOODS
77 TABLE 507.2.8 MINIMUM DISTANCE BETWEEN THE LOWEST EDGE OF A GREASE FILTER AND THE COOKING SURFACE OR THE HEATING SURFACE
79 SECTION 508 COMMERCIAL KITCHEN MAKEUP AIR
SECTION 509 FIRE SUPPRESSION SYSTEMS
SECTION 510 HAZARDOUS EXHAUST SYSTEMS
81 TABLE 510.8 MINIMUM DUCT THICKNESS
TABLE 510.8.2 CLEARANCE TO COMBUSTIBLES
82 SECTION 511 DUST, STOCK AND REFUSE CONVEYING SYSTEMS
TABLE 511.2 CONSTRUCTION, CLEARANCE AND TERMINATION REQUIREMENTS FOR SINGLE-WALL METAL CHIMNEYS
83 SECTION 512 SUBSLAB SOIL EXHAUST SYSTEMS
SECTION 513 SMOKE CONTROL SYSTEMS
84 EQUATION 5-2
85 EQUATION 5-3
87 SECTION 514 ENERGY RECOVERY VENTILATION SYSTEMS
88 CHAPTER 6 DUCT SYSTEMS
SECTION 601 GENERAL
89 SECTION 602 PLENUMS
91 SECTION 603 DUCT CONSTRUCTION AND INSTALLATION
TABLE 603.4 DUCT CONSTRUCTION MINIMUM SHEET METAL THICKNESS FOR SINGLE DWELLING UNITS
93 SECTION 604 INSULATION
94 SECTION 605 AIR FILTERS
SECTION 606 SMOKE DETECTION SYSTEMS CONTROL
95 SECTION 607 DUCT AND TRANSFER OPENINGS
TABLE 607.3.2.1 FIRE DAMPER RATING
100 SECTION 608 BALANCING
102 CHAPTER 7 COMBUSTION AIR
SECTION 701 GENERAL
104 CHAPTER 8 CHIMNEYS AND VENTS
SECTION 801 GENERAL
105 SECTION 802 VENTS
TABLE 802.2 VENT APPLICATION
106 SECTION 803 CONNECTORS
TABLE 803.9(1) MINIMUM CHIMNEY CONNECTOR THICKNESS FOR LOW-HEAT APPLIANCES
TABLE 803.9(2) MINIMUM CHIMNEY CONNECTOR THICKNESS FOR MEDIUM- AND HIGH-HEAT APPLIANCES
107 TABLE 803.10.4 CHIMNEY CONNECTOR SYSTEMS AND CLEARANCES TO COMBUSTIBLE WALL MATERIALS FOR DOMESTIC HEATING APPLIANCES
SECTION 804 DIRECT-VENT, INTEGRAL VENT AND MECHANICAL DRAFT SYSTEMS
108 TABLE 803.10.6 CONNECTOR CLEARANCES TO COMBUSTIBLES
SECTION 805 FACTORY-BUILT CHIMNEYS
109 SECTION 806 METAL CHIMNEYS
110 CHAPTER 9 SPECIFIC APPLIANCES, FIREPLACES AND SOLID FUEL-BURNING EQUIPMENT
SECTION 901 GENERAL
SECTION 902 MASONRY FIREPLACES
SECTION 903 FACTORY-BUILT FIREPLACES
SECTION 904 PELLET FUEL-BURNING APPLIANCES
SECTION 905 FIREPLACE STOVES AND ROOM HEATERS
SECTION 906 FACTORY-BUILT BARBECUE APPLIANCES
SECTION 907 INCINERATORS AND CREMATORIES
SECTION 908 COOLING TOWERS, EVAPORATIVE CONDENSERS AND FLUID COOLERS
111 SECTION 909 VENTED WALL FURNACES
SECTION 910 FLOOR FURNACES
112 SECTION 911 DUCT FURNACES
SECTION 912 INFRARED RADIANT HEATERS
SECTION 913 CLOTHES DRYERS
SECTION 914 SAUNA HEATERS
SECTION 915 ENGINE AND GAS TURBINE-POWERED EQUIPMENT AND APPLIANCES
SECTION 916 POOL AND SPA HEATERS
113 SECTION 917 COOKING APPLIANCES
SECTION 918 FORCED-AIR WARM-AIR FURNACES
SECTION 919 CONVERSION BURNERS
SECTION 920 UNIT HEATERS
SECTION 921 VENTED ROOM HEATERS
SECTION 922 KEROSENE AND OIL-FIRED STOVES
SECTION 923 SMALL CERAMIC KILNS
114 SECTION 924 STATIONARY FUEL CELL POWER SYSTEMS
SECTION 925 MASONRY HEATERS
SECTION 926 GASEOUS HYDROGEN SYSTEMS
SECTION 927 RESERVED
SECTION 928 EVAPORATIVE COOLING EQUIPMENT
SECTION 929 SOLID FUEL-BURNING DEVICES
115 SECTION 930 UNVENTED ALCOHOL FUEL-BURNING DECORATIVE APPLIANCES
SECTION 931 LARGE-DIAMETER CEILING FANS
116 CHAPTER 10 BOILERS, WATER HEATERS AND PRESSURE VESSELS
SECTION 1001 GENERAL
SECTION 1002 WATER HEATERS
SECTION 1003 BOILERS AND PRESSURE VESSELS
SECTION 1004 PERMITS REQUIRED
SECTION 1005 DETAILED REQUIREMENTS
117 SECTION 1006 EXPANSION TANKS
SECTION 1007 SAFETY OR RELIEF VALVE DISCHARGE
SECTION 1008 GAS PRESSURE REGULATORS
SECTION 1009 CLEARANCE FOR ACCESS
SECTION 1010 BOILER ROOM ENCLOSURES
SECTION 1011 FLOORS
SECTION 1012 CHIMNEYS OR VENTS
SECTION 1013 DRAINAGE
SECTION 1014 FUEL SUPPLY PIPING
SECTION 1015 AIR FOR COMBUSTION AND VENTILATION
SECTION 1016 STEAM AND HOT WATER PIPING
118 CHAPTER 11 REFRIGERATION
SECTION 1101 GENERAL
TABLE 1101.2 FACTORY-BUILT EQUIPMENT AND APPLIANCES
SECTION 1102 SYSTEM REQUIREMENTS
119 SECTION 1103 REFRIGERATION SYSTEM CLASSIFICATION
120 TABLE 1103.1 REFRIGERANT CLASSIFICATION, AMOUNT AND OEL
121 TABLE 1103.1—continued REFRIGERANT CLASSIFICATION, AMOUNT AND OEL
122 TABLE 1103.1—continued REFRIGERANT CLASSIFICATION, AMOUNT AND OEL
123 TABLE 1103.1—continued REFRIGERANT CLASSIFICATION, AMOUNT AND OEL
124 TABLE 1103.1—continued REFRIGERANT CLASSIFICATION, AMOUNT AND OEL
125 TABLE 1103.1—continued REFRIGERANT CLASSIFICATION, AMOUNT AND OEL
126 SECTION 1104 SYSTEM APPLICATION REQUIREMENTS
127 TABLE 1104.3.2 MAXIMUM PERMISSIBLE QUANTITIES OF REFRIGERANTS
SECTION 1105 MACHINERY ROOM, GENERAL REQUIREMENTS
128 EQUATION 11-1
EQUATION 11-2
130 SECTION 1106 MACHINERY ROOM, SPECIAL REQUIREMENTS
TABLE 1106.4.2 MINIMUM EXHAUST RATES
SECTION 1107 PIPING MATERIAL
131 TABLE 1107.4 REFRIGERANT PIPE
TABLE 1107.5 REFRIGERANT PIPE FITTINGS
TABLE 1107.5.1 COPPER BRAZED SWAGED CUP DEPTHS
SECTION 1108 JOINTS AND CONNECTIONS
132 SECTION 1109 REFRIGERANT PIPE INSTALLATION
133 TABLE 1109.3.2 SHAFT VENTILATION VELOCITY
134 SECTION 1110 REFRIGERATION PIPING SYSTEM TEST
136 CHAPTER 12 HYDRONIC PIPING
SECTION 1201 GENERAL
SECTION 1202 MATERIAL
TABLE 1202.4 HYDRONIC PIPE
SECTION 1203 JOINTS AND CONNECTIONS
137 TABLE 1202.5 HYDRONIC PIPE FITTINGS
139 SECTION 1204 PIPE INSULATION
SECTION 1205 VALVES
SECTION 1206 PIPING INSTALLATION
140 SECTION 1207 TRANSFER FLUID
SECTION 1208 TESTS
SECTION 1209 EMBEDDED PIPING
SECTION 1210 PLASTIC PIPE GROUND-SOURCE HEAT PUMP LOOP SYSTEMS
141 TABLE 1210.4 GROUND-SOURCE LOOP PIPE
TABLE 1210.5 GROUND-SOURCE LOOP PIPE FITTINGS
144 CHAPTER 13 FUEL OIL PIPING AND STORAGE
SECTION 1301 GENERAL
SECTION 1302 MATERIAL
TABLE 1302.3 FUEL OIL PIPING AND FITTINGS
SECTION 1303 JOINTS AND CONNECTIONS
145 SECTION 1304 PIPING SUPPORT
SECTION 1305 FUEL OIL SYSTEM INSTALLATION
146 SECTION 1306 OIL GAUGING
SECTION 1307 FUEL OIL VALVES
SECTION 1308 TESTING
148 CHAPTER 14 SOLAR THERMAL SYSTEMS
SECTION 1401 GENERAL
SECTION 1402 DESIGN AND INSTALLATION
150 SECTION 1403 HEAT TRANSFER FLUIDS
SECTION 1404 LABELING
152 CHAPTER 15 REFERENCED STANDARDS
ACCA
AHRI
AMCA
ANSI
ASHRAE
153 ASME
154 ASSE
ASSP
ASTM
158 AWS
AWWA
CSA
159 FDA
FS
ICC
IIAR
160 MSS
NAIMA
NFPA
161 NSF
SMACNA
UL
166 APPENDIX A CHIMNEY CONNECTOR PASS-THROUGHS
SECTION A101 CHIMNEY CONNECTOR SYSTEMS
FIGURE A101.1(1) CHIMNEY CONNECTOR SYSTEMS
167 FIGURE A101.1(2) CHIMNEY CONNECTOR SYSTEMS
168 APPENDIX B RECOMMENDED PERMIT FEE SCHEDULE
SECTION B101 MECHANICAL WORK, OTHER THAN GAS PIPING SYSTEMS
SECTION B102 FEE FOR REINSPECTION
SECTION B103 TEMPORARY OPERATION INSPECTION FEE
SECTION B104 SELF-CONTAINED UNITS LESS THAN 2 TONS
170 APPENDIX C FUEL GAS
SECTION C101 SCOPE AND GENERAL REQUIREMENTS
SECTION C102 NOTICE OF APPROVAL
171 SECTION C103 SERVICE UTILITIES
SECTION C104 TEMPORARY EQUIPMENT, SYSTEMS AND USES
SECTION C105 INSPECTIONS AND TESTING
SECTION C201 FUEL GAS DEFINITIONS
172 SECTION C202 GENERAL DEFINITIONS
176 SECTION C301 GENERAL REGULATIONS
SECTION C302 STRUCTURAL SAFETY
SECTION C303 APPLIANCE LOCATION
177 SECTION C304 COMBUSTION, VENTILATION AND DILUTION AIR
178 EQUATION C3-1
EQUATION C3-2
FIGURE C304.5.3 ALL AIR FROM INSIDE THE BUILDING (see Section C304.5.3)
FIGURE C304.6.1(1) ALL AIR FROM OUTDOORS—INLET AIR FROM VENTILATED CRAWL SPACE AND OUTLET AIR TO VENTILATED ATTIC (see Section C304.6.1)
179 FIGURE C304.6.1(2) ALL AIR FROM OUTDOORS THROUGH VENTILATED ATTIC (see Section C304.6.1)
FIGURE C304.6.1(3) ALL AIR FROM OUTDOORS (see Section C304.6.1)
FIGURE C304.6.2 SINGLE COMBUSTION AIR OPENING, ALL AIR FROM THE OUTDOORS (see Section C304.6.2)
180 SECTION C305 INSTALLATION
181 SECTION C306 ACCESS AND SERVICE SPACE
182 SECTION C307 CONDENSATE DISPOSAL
183 SECTION C308 CLEARANCE REDUCTION
TABLE C308.2 REDUCTION OF CLEARANCES WITH SPECIFIED FORMS OF PROTECTIONa through k
184 FIGURE C308.2(1) EXTENT OF PROTECTION NECESSARY TO REDUCE CLEARANCES FROM APPLIANCE OR VENT CONNECTIONS
FIGURE C308.2(2) WALL PROTECTOR CLEARANCE REDUCTION SYSTEM
FIGURE C308.2(3) MASONRY CLEARANCE REDUCTION SYSTEM
185 SECTION C309 ELECTRICAL
SECTION C310 ELECTRICAL BONDING
SECTION C401 GAS PIPING INSTALLATIONS
186 SECTION C402 PIPE SIZING
EQUATION C4-1
EQUATION C4-2
187 TABLE C402.4 Cr AND Y VALUES FOR NATURAL GAS AND UNDILUTED PROPANE AT STANDARD CONDITIONS
188 TABLE C402.4(1) SCHEDULE 40 METALLIC PIPE
189 TABLE C402.4(2) SCHEDULE 40 METALLIC PIPE
190 TABLE C402.4(3) SCHEDULE 40 METALLIC PIPE
191 TABLE C402.4(4) SCHEDULE 40 METALLIC PIPE
192 TABLE C402.4(5) SCHEDULE 40 METALLIC PIPE
193 TABLE C402.4(6) SCHEDULE 40 METALLIC PIPE
194 TABLE C402.4(7) SCHEDULE 40 METALLIC PIPE
195 TABLE C402.4(8) SEMIRIGID COPPER TUBING
196 TABLE C402.4(9) SEMIRIGID COPPER TUBING
197 TABLE C402.4(10) SEMIRIGID COPPER TUBING
198 TABLE C402.4(11) SEMIRIGID COPPER TUBING
199 TABLE C402.4(12) SEMIRIGID COPPER TUBING
200 TABLE C402.4(13) SEMIRIGID COPPER TUBING
201 TABLE C402.4(14) SEMIRIGID COPPER TUBING
202 TABLE C402.4(15) CORRUGATED STAINLESS STEEL TUBING (CSST)
203 TABLE C402.4(16) CORRUGATED STAINLESS STEEL TUBING (CSST)
204 TABLE C402.4(17) CORRUGATED STAINLESS STEEL TUBING (CSST)
205 TABLE C402.4(18) CORRUGATED STAINLESS STEEL TUBING (CSST)
206 TABLE C402.4(19) CORRUGATED STAINLESS STEEL TUBING (CSST)
207 TABLE C402.4(20) POLYETHYLENE PLASTIC PIPE
208 TABLE C402.4(21) POLYETHYLENE PLASTIC PIPE
209 TABLE C402.4(22) POLYETHYLENE PLASTIC PIPE
210 TABLE C402.4(23) POLYETHYLENE PLASTIC TUBING
TABLE C402.4(24) POLYETHYLENE PLASTIC TUBING
211 TABLE C402.4(25) SCHEDULE 40 METALLIC PIPE
212 TABLE C402.4(26) SCHEDULE 40 METALLIC PIPE
213 TABLE C402.4(27) SCHEDULE 40 METALLIC PIPE
214 TABLE C402.4(28) SCHEDULE 40 METALLIC PIPE
215 TABLE C402.4(29) SEMIRIGID COPPER TUBING
216 TABLE C402.4(30) SEMIRIGID COPPER TUBING
217 TABLE C402.4(31) SEMIRIGID COPPER TUBING
218 TABLE C402.4(32) CORRUGATED STAINLESS STEEL TUBING (CSST)
219 TABLE C402.4(33) CORRUGATED STAINLESS STEEL TUBING (CSST)
220 TABLE C402.4(34) CORRUGATED STAINLESS STEEL TUBING (CSST)
221 TABLE C402.4(35) POLYETHYLENE PLASTIC PIPE
222 TABLE C402.4(36) POLYETHYLENE PLASTIC PIPE
223 TABLE C402.4(37) POLYETHYLENE PLASTIC TUBING
224 SECTION C403 PIPING MATERIALS
225 TABLE C403.8.2 SPECIFICATIONS FOR THREADING METALLIC PIPE
226 SECTION C404 PIPING SYSTEM INSTALLATION
228 SECTION C405 PIPING BENDS AND CHANGES IN DIRECTION
229 SECTION C406 INSPECTION, TESTING AND PURGING
230 SECTION C407 PIPING SUPPORT
SECTION C408 DRIPS AND SLOPED PIPING
FIGURE C408.4 METHOD OF INSTALLING A TEE FITTING SEDIMENT TRAP
SECTION C409 SHUTOFF VALVES
231 TABLE C409.1.1 MANUAL GAS VALVE STANDARDS
SECTION C410 FLOW CONTROLS
232 SECTION C411 APPLIANCE AND MANUFACTURED HOME CONNECTIONS
233 SECTION C412 LIQUEFIED PETROLEUM GAS MOTOR VEHICLE FUEL-DISPENSING FACILITIES
SECTION C413 COMPRESSED NATURAL GAS MOTOR VEHICLE FUEL-DISPENSING FACILITIES
SECTION C414 SUPPLEMENTAL AND STANDBY GAS SUPPLY
234 SECTION C415 PIPING SUPPORT INTERVALS
TABLE C415.1 SUPPORT OF PIPING
SECTION C416 FUEL GAS EQUIPMENT AND INSTALLATIONS IN MANUFACTURED STRUCTURE (MOBILE HOME OR RECREATIONAL VEHICLE) PARKS
TABLE C416.1 MINIMUM DEMAND FACTORS FOR CACULATING GAS PIPING SYSTEMS IN MANUFACTURED STRUCTURE PARKS
SECTION C417 OVERPRESSURE PROTECTION DEVICES
235 SECTION C501 CHIMNEYS AND VENTS
237 SECTION C502 VENTS
SECTION C503 VENTING OF APPLIANCES
238 TABLE C503.4 TYPE OF VENTING SYSTEM TO BE USED
241 FIGURE C503.6.5 TERMINATION LOCATIONS FOR GAS VENTS WITH LISTED CAPS 12 INCHES OR LESS IN SIZE NOT LESS THAN 8 FEET FROM A VERTICAL WALL
243 TABLE C503.8 THROUGH-THE-WALL VENT TERMINAL CLEARANCE
244 FIGURE C503.8 THROUGH-THE-WALL VENT TERMINAL CLEARANCE
245 TABLE C503.10.2.4 MINIMUM THICKNESS FOR GALVANIZED STEEL VENT CONNECTORS FOR LOW-HEAT APPLIANCES
TABLE C503.10.2.5 MINIMUM THICKNESS FOR STEEL VENT CONNECTORS FOR MEDIUM-HEAT APPLIANCES
246 TABLE C503.10.5 CLEARANCES FOR CONNECTORSa
247 SECTION C504 SIZING OF CATEGORY I APPLIANCE VENTING SYSTEMS
249 TABLE C504.3.2 MAXIMUM VENT CONNECTOR LENGTH
252 SECTION C505 DIRECT-VENT, INTEGRAL VENT, MECHANICAL VENT AND VENTILATION/EXHAUST HOOD VENTING
SECTION C506 FACTORY-BUILT CHIMNEYS
253 TABLE C504.2(1) TYPE B DOUBLE-WALL GAS VENT
254 TABLE C504.2(1)—continued TYPE B DOUBLE-WALL GAS VENT
255 TABLE C504.2(1)—continued TYPE B DOUBLE-WALL GAS VENT
256 TABLE C504.2(1)—continued TYPE B DOUBLE-WALL GAS VENT
257 TABLE C504.2(2) TYPE B DOUBLE-WALL GAS VENT
258 TABLE C504.2(2)—continued TYPE B DOUBLE-WALL GAS VENT
259 TABLE C504.2(3) MASONRY CHIMNEY
260 TABLE C504.2(3)—continued MASONRY CHIMNEY
261 TABLE C504.2(4) MASONRY CHIMNEY
262 TABLE C504.2(4)—continued MASONRY CHIMNEY
263 TABLE C504.2(5) SINGLE-WALL METAL PIPE OR TYPE B ASBESTOS CEMENT VENT
264 TABLE C504.2(6) EXTERIOR MASONRY CHIMNEY
265 TABLE C504.3(1) TYPE B DOUBLE-WALL VENT
266 TABLE C504.3(1)—continued TYPE B DOUBLE-WALL VENT
267 TABLE C504.3(2) TYPE B DOUBLE-WALL VENT
268 TABLE C504.3(3) MASONRY CHIMNEY
269 TABLE C504.3(4) MASONRY CHIMNEY
270 TABLE C504.3(5) SINGLE-WALL METAL PIPE OR TYPE ASBESTOS CEMENT VENT
271 TABLE C504.3(6a) EXTERIOR MASONRY CHIMNEY
TABLE C504.3(6b) EXTERIOR MASONRY CHIMNEY
TABLE C504.3(6b)—continued EXTERIOR MASONRY CHIMNEY
272 TABLE C504.3(7a) EXTERIOR MASONRY CHIMNEY
TABLE C504.3(7b) EXTERIOR MASONRY CHIMNEY
TABLE C504.3(7b)—continued EXTERIOR MASONRY CHIMNEY
273 SECTION C601 SPECIFIC APPLIANCES
SECTION C602 DECORATIVE APPLIANCES FOR INSTALLATION IN FIREPLACES
SECTION C603 LOG LIGHTERS
SECTION C604 VENTED GAS FIREPLACES (DECORATIVE APPLIANCES)
SECTION C605 VENTED GAS FIREPLACE HEATERS
SECTION C606 INCINERATORS AND CREMATORIES
SECTION C607 COMMERCIAL-INDUSTRIAL INCINERATORS
SECTION C608 VENTED WALL FURNACES
SECTION C609 FLOOR FURNACES
274 SECTION C610 DUCT FURNACES
SECTION C611 NONRECIRCULATING DIRECT-FIRED INDUSTRIAL AIR HEATERS
275 SECTION C612 RECIRCULATING DIRECT-FIRED INDUSTRIAL AIR HEATERS
SECTION C613 CLOTHES DRYERS
SECTION C614 CLOTHES DRYER EXHAUST
SECTION C615 SAUNA HEATERS
SECTION C616 ENGINE AND GAS TURBINE-POWERED EQUIPMENT
276 SECTION C617 POOL AND SPA HEATERS
SECTION C618 FORCED-AIR WARM-AIR FURNACES
SECTION C619 CONVERSION BURNERS
277 SECTION C620 UNIT HEATERS
SECTION C621 UNVENTED ROOM HEATERS
SECTION C622 VENTED ROOM HEATERS
SECTION C623 COOKING APPLIANCES
278 SECTION C624 WATER HEATERS
SECTION C625 REFRIGERATORS
SECTION C626 GAS-FIRED TOILETS
SECTION C627 AIR-CONDITIONING APPLIANCES
279 SECTION C628 ILLUMINATING APPLIANCES
SECTION C629 SMALL CERAMIC KILNS
SECTION C630 INFRARED RADIANT HEATERS
280 SECTION C631 BOILERS
SECTION C632 RESERVED
SECTION C633 STATIONARY FUEL-CELL POWER SYSTEMS
SECTION C634 GASEOUS HYDROGEN SYSTEMS
SECTION C635 OUTDOOR DECORATIVE APPLIANCES
SECTION C701 GASEOUS HYDROGEN SYSTEMS, GENERAL
SECTION C702 GENERAL DEFINITIONS
SECTION C703 GENERAL REQUIREMENTS
281 SECTION C704 PIPING, USE AND HANDLING
282 SECTION C705 TESTING OF HYDROGEN PIPING SYSTEMS
283 SECTION C706 LOCATION OF GASEOUS HYDROGEN SYSTEMS
SECTION C707 OPERATION OF GASEOUS HYDROGEN SYSTEMS
SECTION C708 DESIGN OF LIQUEFIED HYDROGEN SYSTEMS ASSOCIATED WITH HYDROGEN VAPORIZATION OPERATIONS
284 SECTION C801 REFERENCED STANDARDS
ANSI
285 ASME
286 ASTM
287 CGA
CSA
DOTn
MSS
NFPA
288 UL
290 APPENDIX C-A SIZING AND CAPACITIES OF GAS PIPING
SECTION C-A101 GENERAL PIPING CONSIDERATIONS
SECTION C-A102 DESCRIPTION OF TABLES
291 TABLE C-A102.2 EQUIVALENT LENGTHS OF PIPE FITTINGS AND VALVES
292 TABLE C-A102.2—continued EQUIVALENT LENGTHS OF PIPE FITTINGS AND VALVES
293 TABLE C-A102.4 MULTIPLIERS TO BE USED WITH TABLES 402.4(1) THROUGH 402.4(22) WHERE THE SPECIFIC GRAVITY OF THE GAS IS OTHER THAN 0.60
SECTION C-A103 USE OF CAPACITY TABLES
295 TABLE C-A103.4 THOUSANDS OF BTU/H (MBH) OF NATURAL GAS PER 100 FEET OF PIPE AT VARIOUS PRESSURE DROPS AND PIPE DIAMETERS
SECTION C-A104 USE OF SIZING EQUATIONS
296 SECTION C-A105 PIPE AND TUBE DIAMETERS
TABLE C-A105.1 SCHEDULE 40 STEEL PIPE STANDARD SIZES
TABLE C-A105.2 COPPER TUBE STANDARD SIZES
TABLE C-A105.2-continued COPPER TUBE STANDARD SIZES
SECTION C-A106 EXAMPLES OF PIPING SYSTEM DESIGN AND SIZING
297 FIGURE C-A106.1 PIPING PLAN SHOWING A STEEL PIPING SYSTEM
298 FIGURE C-A106.2 PIPING PLAN SHOWING A CSST SYSTEM
FIGURE C-A106.3 PIPING PLAN SHOWING A COPPER TUBING SYSTEM
299 FIGURE C-A106.4 PIPING PLAN SHOWING A MODIFICATION TO EXISTING PIPING SYSTEM
302 APPENDIX C-B SIZING OF VENTING SYSTEMS SERVING APPLIANCES EQUIPPED WITH DRAFT HOODS, CATEGORY I APPLIANCES AND APPLIANCES LISTED FOR USE WITH TYPE B VENTS
SECTION C-B101 EXAMPLES USING SINGLE-APPLIANCE VENTING TABLES
FIGURE C-B101.1 EXAMPLE 1—SINGLE DRAFT-HOOD-EQUIPPED APPLIANCE
303 FIGURE C-B101.2 EXAMPLE 2—SINGLE FAN-ASSISTED APPLIANCE
FIGURE C-B101.4(1) TYPE B DOUBLE-WALL VENT SYSTEM SERVING A SINGLE APPLIANCE WITH A TYPE B DOUBLE-WALL VENT
304 FIGURE C-B101.4(2) TYPE B DOUBLE-WALL VENT SYSTEM SERVING A SINGLE APPLIANCE WITH A SINGLE-WALL METAL VENT CONNECTOR
FIGURE C-B101.4(3) VENT SYSTEM SERVING A SINGLE APPLIANCE WITH A MASONRY CHIMNEY OF TYPE B DOUBLE-WALL VENT CONNECTOR
FIGURE C-B101.4(4) VENT SYSTEM SERVING A SINGLE APPLIANCE USING A MASONRY CHIMNEY AND A SINGLE-WALL METAL VENT CONNECTOR
FIGURE C-B101.4(5) ASBESTOS CEMENT TYPE B OR SINGLE-WALL METAL VENT SYSTEM SERVING A SINGLE DRAFT-HOOD-EQUIPPED APPLIANCE
305 SECTION C-B102 EXAMPLES USING COMMON VENTING TABLES
FIGURE C-B102.1 EXAMPLE 4—COMMON VENTING TWO DRAFT-HOOD-EQUIPPED APPLIANCES
306 FIGURE C-B102.2 EXAMPLE 5A—COMMON VENTING A DRAFT HOOD WITH A FAN-ASSISTED FURNACE INTO A TYPE B DOUBLE-WALL COMMON VENT
307 TABLE C-B102.3 MASONRY CHIMNEY LINER DIMENSIONS WITH CIRCULAR EQUIVALENTSa
308 FIGURE C-B102.5(1) VENT SYSTEM SERVING TWO OR MORE APPLIANCES WITH TYPE B DOUBLE-WALL VENT AND TYPE B DOUBLE-WALL VENT CONNECTOR
FIGURE C-B102.5(2) VENT SYSTEM SERVING TWO OR MORE APPLIANCES WITH TYPE B DOUBLE-WALL VENT AND SINGLE-WALL METAL VENT CONNECTORS
FIGURE C-B102.5(3) MASONRY CHIMNEY SERVING TWO OR MORE APPLIANCES WITH TYPE B DOUBLE-WALL VENT CONNECTOR
FIGURE C-B102.5(4) MASONRY CHIMNEY SERVING TWO OR MORE APPLIANCES WITH SINGLE-WALL METAL VENT CONNECTORS
309 FIGURE C-B102.5(5) ASBESTOS CEMENT TYPE B OR SINGLE-WALL METAL VENT SYSTEM SERVING TWO OR MORE DRAFT-HOOD-EQUIPPED APPLIANCES
FIGURE C-B102.5(6) USE OF MANIFOLD COMMON VENT CONNECTOR
FIGURE C-B102.5(7) USE OF OFFSET COMMON VENT
310 FIGURE C-B102.5(8) MULTISTORY GAS VENT DESIGN PROCEDURE FOR EACH SEGMENT OF SYSTEM
FIGURE C-B102.5(9) MULTISTORY VENT SYSTEMS
311 FIGURE C-B102.5(10) NATIONAL FUEL GAS CODE 99-PERCENT WINTER DESIGN TEMPERATURES FOR THE CONTIGUOUS UNITED STATES
312 APPENDIX C-CEXIT TERMINALS OF MECHANICAL DRAFT AND DIRECT-VENT VENTING SYSTEMS
SECTION C-C101 GENERAL
FIGURE C-C101.1 EXIT TERMINALS OF MECHANICAL DRAFT AND DIRECT-VENT VENTING SYSTEMS
314 APPENDIX C-D RECOMMENDED PROCEDURE FOR SAFETY INSPECTION OF AN EXISTING APPLIANCE INSTALLATION
SECTION C-D101 GENERAL
SECTION C-D102 OCCUPANT AND INSPECTOR SAFETY
315 SECTION C-D103 GAS PIPING AND CONNECTIONS INSPECTIONS
SECTION C-D104 INSPECTIONS TO BE PERFORMED WITH THE APPLIANCE NOT OPERATING
316 SECTION C-D105 INSPECTIONS TO BE PERFORMED WITH THE APPLIANCE OPERATING
317 SECTION C-D106 APPLIANCE-SPECIFIC INSPECTIONS
318 TABLE C-D106 CO THRESHOLDS
319 TABLE C-D106—continued CO THRESHOLDS
320 INDEX
MECHANICAL INDEX
326 FUEL GAS INDEX
330 ADDITIONAL CODE RESOURCES FROM ICC
331 ICC EVALUATION SERVICE
332 ICC ASSESSMENT CENTER
333 ICC DIGITAL CODES PREMIUM
OR MechanicalSpecialtyCode 2022 1stptg
$76.92