Shopping Cart

No products in the cart.

VT CommercialBuildingEnergyStandards 2011

$12.46

Vermont Commercial Building Energy Standards

Published By Publication Date Number of Pages
VT 2011 62
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

Custom code based on the Commercial provisions of the 2009 International Energy Conservation Code.

PDF Catalog

PDF Pages PDF Title
1 2011 VERMONT COMMERCIAL BUILDING ENERGY STANDARDS
2 COPYRIGHT
3 PREFACE
4 EFFECTIVE USE OF THE 2011 COMMERCIAL BUILDING ENERGY STANDARDS
5 TABLE OF CONTENTS
7 CHAPTER 1: ADMINISTRATION
PART 1—SCOPE AND APPLICATION
SECTION 101 SCOPE AND GENERAL REQUIREMENTS
8 SECTION 102 ALTERNATE MATERIALS—METHOD OF CONSTRUCTION, DESIGNOR INSULATING SYSTEMS
PART 2—ADMINISTRATION AND ENFORCEMENT
SECTION 103 CONSTRUCTION DOCUMENTS
9 SECTION 104 INSPECTIONS
SECTION 105 VALIDITY
SECTION 106 REFERENCED STANDARDS
11 CHAPTER 2: DEFINITIONS
SECTION 201 GENERAL
SECTION 202 GENERAL DEFINITIONS
15 CHAPTER 3: GENERAL REQUIREMENTS
SECTION 301 DESIGN CONDITIONS
SECTION 302 MATERIALS, SYSTEMS AND EQUIPMENT
TABLE 302.1.3(1) DEFAULT GLAZED FENESTRATION U-FACTOR
TABLE 302.1.3(2) DEFAULT DOOR U-FACTORS
16 TABLE 302.1.3(3) DEFAULT GLAZED FENESTRATION SHGC
17 CHAPTER 4: RESIDENTIAL ENERGY EFFICIENCY
19 CHAPTER 5: COMMERCIAL ENERGY EFFICIENCY
SECTION 501 GENERAL
20 SECTION 502 BUILDING ENVELOPE REQUIREMENTS
21 EQUATION 5-1
22 TABLE 502.1(1) BUILDING ENVELOPE REQUIREMENTS–OPAQUE ASSEMBLIES AND ELEMENTSa,b
23 TABLE 502.1(2) BUILDING ENVELOPE REQUIREMENTS–METAL BUILDING ASSEMBLY DESCRIPTIONS
24 TABLE 502.1(2)–continued BUILDING ENVELOPE REQUIREMENTS–METAL BUILDING ASSEMBLY DESCRIPTIONS
25 TABLE 502.1(3) ASSEMBLY U-FACTORS FOR METAL BUILDING ROOFS
26 TABLE 502.1(4) ASSEMBLY U-FACTORS FOR METAL BUILDING WALLS
TABLE 502.3 BUILDING ENVELOPE REQUIREMENTS: FENESTRATION
28 TABLE 502.4.3 MAXIMUM AIR INFILTRATION RATE FOR FENESTRATION ASSEMBLIES
29 SECTION 503 BUILDING MECHANICAL SYSTEMS
31 TABLE 503.2.3(1) MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED UNITARY AIR CONDITIONERS AND CONDENSING UNITS
32 TABLE 503.2.3(1)—continued MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED UNITARY AIR CONDITIONERS AND CONDENSING UNITS
TABLE 503.2.3(2) MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED UNITARY AND APPLIED HEAT PUMPS
33 TABLE 503.2.3(2)—continued MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED UNITARY AND APPLIED HEAT PUMPS
34 TABLE 503.2.3(3) PACKAGED TERMINAL AIR CONDITIONERS, PACKAGED TERMINAL HEAT PUMPS, SINGLE-PACKAGE VERTICAL AIR CONDITIONERS, SINGLE VERTICAL HEAT PUMPS, ROOM AIR CONDITIONERS AND ROOM AIR-CONDITIONER HEAT PUMPS
35 TABLE 503.2.3(3)—continued PACKAGED TERMINAL AIR CONDITIONERS, PACKAGED TERMINAL HEAT PUMPS, SINGLE-PACKAGE VERTICAL AIR CONDITIONERS, SINGLE VERTICAL HEAT PUMPS, ROOM AIR CONDITIONERS AND ROOM AIR-CONDITIONER HEAT PUMPS
TABLE 503.2.3(4) WARM AIR FURNACES AND COMBINATION WARM AIR FURNACES/AIR-CONDITIONING UNITS,WARM AIR DUCT FURNACES AND UNIT HEATERS, MINIMUM EFFICIENCY REQUIREMENTS
36 TABLE 503.2.3(5) BOILERS, GAS- AND OIL-FIRED, MINIMUM EFFICIENCY REQUIREMENTS
37 TABLE 503.2.3(6) WATER CHILLING PACKAGES, EFFICIENCY REQUIREMENTSa
39 EQUATION 5-2
40 TABLE 503.2.8 MINIMUM PIPE INSULATIONa (thickness in inches)
41 TABLE 503.2.11.1(1) FAN POWER LIMITATION
42 TABLE 503.2.11.1(2) FAN POWER LIMITATION PRESSURE DROP ADJUSTMENT
43 TABLE 503.3.1.1.3(1) HIGH-LIMIT SHUTOFF CONTROL OPTIONS FOR AIR ECONOMIZERS
TABLE 503.3.1.1.3(2) HIGH-LIMIT SHUTOFF CONTROL SETTING FOR AIR ECONOMIZERS
46 TABLE 503.4.7 MAXIMUM HOT GAS BYPASS CAPACITY
SECTION 504 SERVICE WATER HEATING (Mandatory)
47 TABLE 504.2 MINIMUM PERFORMANCE OF WATER-HEATING EQUIPMENT
48 SECTION 505 ELECTRICAL POWER AND LIGHTING SYSTEMS (Mandatory)
50 TABLE 505.5.2(1) INTERIOR LIGHTING POWER ALLOWANCES BUILDING AREA METHOD
51 TABLE 505.5.2(2) INTERIOR LIGHTING POWER ALLOWANCES—SPACE-BY-SPACE METHOD
Table 505.5.2(2)—continued INTERIOR LIGHTING POWER ALLOWANCES—SPACE-BY-SPACE METHOD
52 Table 505.5.2(2)—continued INTERIOR LIGHTING POWER ALLOWANCES—SPACE-BY-SPACE METHOD
TABLE 505.6.2(1) EXTERIOR LIGHTING ZONES
53 TABLE 505.6.2(2) INDIVIDUAL LIGHTING POWER ALLOWANCES FOR BUILDING EXTERIORS
54 TABLE 505.8(1) MINIMUM NOMINAL EFFICIENCY FOR GENERAL PURPOSE DESIGN A AND DESIGN B MOTORS RATED 600 VOLTS OR LESSa
55 TABLE 505.11(1) NEMA PREMIUM EFFICIENCY LEVELS FOR DRY-TYPE DISTRIBUTION TRANSFORMERS
56 TABLE 505.11(2) NEMA CLASS 1 EFFICIENCY LEVELS FOR LIQUID-FILLED DISTRIBUTION TRANSFORMERS
57 CHAPTER 6 REFERENCED STANDARDS
AAMA
AHAM
AHRI
AMCA
58 ANSI
ASHRAE
ASME
ASTM
CSA
59 DASMA
DOE
ICC
IESNA
NFRC
60 SMACNA
UL
WDMA
61 INDEX
VT CommercialBuildingEnergyStandards 2011
$12.46