{"id":110764,"date":"2024-10-18T16:00:09","date_gmt":"2024-10-18T16:00:09","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/icc-significantchangestoplbg-mech-ifgc-2012\/"},"modified":"2024-10-24T21:58:48","modified_gmt":"2024-10-24T21:58:48","slug":"icc-significantchangestoplbg-mech-ifgc-2012","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/icc\/icc-significantchangestoplbg-mech-ifgc-2012\/","title":{"rendered":"ICC SignificantChangestoPlbg Mech IFGC 2012"},"content":{"rendered":"

If you are sorting through a key code whether it is the International Plumbing, Mechanical, or Fuel Gas Codes<\/p>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
1<\/td>\nCover <\/td>\n<\/tr>\n
4<\/td>\nContents <\/td>\n<\/tr>\n
12<\/td>\nPART 1 International Plumbing Code (Chapters 1 through 14) <\/td>\n<\/tr>\n
15<\/td>\n202 Plumbing Fixture Definition <\/td>\n<\/tr>\n
16<\/td>\n202 Plumbing Appliance Definition <\/td>\n<\/tr>\n
17<\/td>\n202 Grease Interceptor Definition <\/td>\n<\/tr>\n
19<\/td>\n303.1, 303.4 Material Identification and Third-Party Certification <\/td>\n<\/tr>\n
21<\/td>\n308.9 Parallel Water Distribution Systems <\/td>\n<\/tr>\n
22<\/td>\n315.1 Sealing of Annular Spaces at Penetrations <\/td>\n<\/tr>\n
24<\/td>\nTable 403.1 Minimum Number of Required Plumbing Fixtures <\/td>\n<\/tr>\n
25<\/td>\n403.2 Separate Toilet Facilities in Group M Occupancies <\/td>\n<\/tr>\n
27<\/td>\n403.2.1 Family or Assisted-Use Toilet Facilities Serving as Separate Facilities <\/td>\n<\/tr>\n
28<\/td>\n403.3.2 Relationship of Toilet Rooms and Food Preparation Areas <\/td>\n<\/tr>\n
30<\/td>\n403.3.6 Locking of Toilet Room Doors <\/td>\n<\/tr>\n
31<\/td>\n403.5 Drinking Fountain Locations <\/td>\n<\/tr>\n
32<\/td>\n405.3.1 Minimum Water Closet Compartment Size <\/td>\n<\/tr>\n
34<\/td>\n405.4 Floor and Wall Drainage Connections <\/td>\n<\/tr>\n
35<\/td>\n407.2 Bathtub Waste Outlets and Overflows <\/td>\n<\/tr>\n
36<\/td>\n410 Minimum Required Number of Drinking Fountains <\/td>\n<\/tr>\n
38<\/td>\n417.5.2.6 Shower Pan Liner Materials <\/td>\n<\/tr>\n
39<\/td>\n424.9 Water Closet Personal Hygiene Devices <\/td>\n<\/tr>\n
40<\/td>\n504.4.1 Water Heater Storage Tank Relief Valves <\/td>\n<\/tr>\n
41<\/td>\n504.7 Water Heater Pans <\/td>\n<\/tr>\n
42<\/td>\n605 Polyethylene of Raised-Temperature (PE-RT) Plastic Tubing <\/td>\n<\/tr>\n
44<\/td>\nTable 605.3 Polyethylene (PE) Water Service Pipe <\/td>\n<\/tr>\n
45<\/td>\nTable 605.3 PEX Water Service Pipe <\/td>\n<\/tr>\n
46<\/td>\n606.7 Labeling of Water Distribution Pipes in Bundles <\/td>\n<\/tr>\n
47<\/td>\n607.1.1 Water-Temperature-Limiting Means <\/td>\n<\/tr>\n
48<\/td>\n607.2 Hot or Tempered Water Supply to Fixtures <\/td>\n<\/tr>\n
49<\/td>\n607.5 Hot Water Piping Insulation <\/td>\n<\/tr>\n
50<\/td>\n608.8 Identification of Nonpotable Water <\/td>\n<\/tr>\n
51<\/td>\n704.3, 711.2.1 Horizontal Branch Connections <\/td>\n<\/tr>\n
53<\/td>\nTable 709.1 Drainage Fixture Units for Bathroom Groups <\/td>\n<\/tr>\n
54<\/td>\n712.3.3 Sump Pump and Ejector Discharge Pipe and Fittings <\/td>\n<\/tr>\n
55<\/td>\n712.3.5 Sump Pump Connection to the Drainage System <\/td>\n<\/tr>\n
57<\/td>\n715.1 Fixture Protection from Sewage Backflow <\/td>\n<\/tr>\n
59<\/td>\n802.1.8 Indirect Discharge of Food Preparation Sinks <\/td>\n<\/tr>\n
60<\/td>\n802.2 Installation of Indirect Waste Piping <\/td>\n<\/tr>\n
62<\/td>\n802.3 Prohibited Locations for Waste Receptors <\/td>\n<\/tr>\n
64<\/td>\n901.3, 918.8 Air Admittance Valves for Chemical Waste Vent Systems <\/td>\n<\/tr>\n
65<\/td>\n903.5 Location of Vent Terminals <\/td>\n<\/tr>\n
66<\/td>\n915.2 Combination Waste and Vent System Sizing <\/td>\n<\/tr>\n
67<\/td>\n917 Single-Stack Vent Systems <\/td>\n<\/tr>\n
71<\/td>\n1002.1 Floor Drains in Multi-Level Parking Structures <\/td>\n<\/tr>\n
72<\/td>\n1003.1 Interceptors and Separators <\/td>\n<\/tr>\n
73<\/td>\n1003.3.1 Alternate Grease Interceptor Locations <\/td>\n<\/tr>\n
74<\/td>\n1003.3.4 Hydromechanical Grease Interceptors <\/td>\n<\/tr>\n
76<\/td>\n1105 Roof Drain Strainers <\/td>\n<\/tr>\n
78<\/td>\n1107 Siphonic Roof Drainage Systems <\/td>\n<\/tr>\n
80<\/td>\nChapter 13 Gray-Water Recycling Systems <\/td>\n<\/tr>\n
83<\/td>\nPART 2 International Mechanical Code (Chapters 1 through 15) <\/td>\n<\/tr>\n
85<\/td>\n102.3 Maintenance <\/td>\n<\/tr>\n
86<\/td>\n202 Environmental Air <\/td>\n<\/tr>\n
87<\/td>\n306.5 Equipment and Appliances on Roofs or Elevated Structures <\/td>\n<\/tr>\n
90<\/td>\n308.5 Labeled Assemblies <\/td>\n<\/tr>\n
91<\/td>\n401.4 Intake Opening Location <\/td>\n<\/tr>\n
93<\/td>\nTable 403.3 Minimum Ventilation Rates for Nail Salons <\/td>\n<\/tr>\n
94<\/td>\n404.1 Enclosed Parking Garages <\/td>\n<\/tr>\n
95<\/td>\n501.2, 506.4 Independent Exhaust Systems Required <\/td>\n<\/tr>\n
96<\/td>\n505.1 Domestic Kitchen Exhaust Systems <\/td>\n<\/tr>\n
97<\/td>\n506.3.7.1 Grease Reservoirs <\/td>\n<\/tr>\n
98<\/td>\n506.3.8 Grease Duct Cleanouts and Other Openings <\/td>\n<\/tr>\n
100<\/td>\n506.3.9 Grease Duct Horizontal Cleanouts <\/td>\n<\/tr>\n
101<\/td>\n506.3.10 Underground Grease Duct Installations <\/td>\n<\/tr>\n
103<\/td>\n506.3.11.2 Field-Applied Grease Duct Enclosures <\/td>\n<\/tr>\n
104<\/td>\n507.2 Type I or Type II Hood Required <\/td>\n<\/tr>\n
105<\/td>\n507.2.1 Type I Hoods <\/td>\n<\/tr>\n
106<\/td>\n507.2.1.1 Operation of Type I Hoods <\/td>\n<\/tr>\n
108<\/td>\n507.2.1.2 Exhaust Flow Rate Label of Type I Hoods <\/td>\n<\/tr>\n
109<\/td>\n507.2.2 Type II Hoods <\/td>\n<\/tr>\n
110<\/td>\n507.10 Hoods Penetrating a Ceiling <\/td>\n<\/tr>\n
111<\/td>\n510.7 Fire Suppression Required for Hazardous Exhaust Ducts <\/td>\n<\/tr>\n
112<\/td>\n601.4 Contamination Prevention in Plenums <\/td>\n<\/tr>\n
114<\/td>\n602.2.1 Materials within Plenums <\/td>\n<\/tr>\n
116<\/td>\n603.7 Rigid Duct Penetrations <\/td>\n<\/tr>\n
117<\/td>\n603.9 Duct Joints, Seams, and Connections <\/td>\n<\/tr>\n
118<\/td>\n603.17, 202 Air Dispersion Systems <\/td>\n<\/tr>\n
119<\/td>\n805.3 Factory-Built Chimney Offsets <\/td>\n<\/tr>\n
120<\/td>\n901.4 Fireplace Accessories <\/td>\n<\/tr>\n
121<\/td>\n928 Evaporative Cooling Equipment <\/td>\n<\/tr>\n
122<\/td>\n1101.10 Locking Access Port Caps <\/td>\n<\/tr>\n
123<\/td>\n1105.6, 1105.6.3 Machinery Room Ventilation <\/td>\n<\/tr>\n
124<\/td>\n1106.4 Flammable Refrigerants <\/td>\n<\/tr>\n
125<\/td>\nPART 3 International Fuel Gas Code (Chapters 1 through 8) <\/td>\n<\/tr>\n
127<\/td>\n202, 401.9, 401.10, 404.1 Identification, Testing and Certification <\/td>\n<\/tr>\n
128<\/td>\n308.1 Clearance to Combustible materials <\/td>\n<\/tr>\n
129<\/td>\n404.2 CSST piping systems <\/td>\n<\/tr>\n
130<\/td>\n404.18 Prohibited Devices <\/td>\n<\/tr>\n
131<\/td>\n408.4 Sediment Traps <\/td>\n<\/tr>\n
132<\/td>\n410.4 Excess Flow Valves <\/td>\n<\/tr>\n
133<\/td>\n202, 410.5 Flashback Arrestor Check Valve <\/td>\n<\/tr>\n
134<\/td>\n618.4 Prohibited Sources <\/td>\n<\/tr>\n
136<\/td>\nIndex
A
B
C
D <\/td>\n<\/tr>\n
137<\/td>\nE
F
G
H <\/td>\n<\/tr>\n
138<\/td>\nI <\/td>\n<\/tr>\n
139<\/td>\nL
M
N
O
P <\/td>\n<\/tr>\n
140<\/td>\nR
S <\/td>\n<\/tr>\n
141<\/td>\nT
U
V
W <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

Significant Changes to the IPC, IMC, and IFGC, 2012 Edition<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
ICC<\/b><\/a><\/td>\n2012<\/td>\n145<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":110765,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[2670],"product_tag":[],"class_list":{"0":"post-110764","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-icc","8":"first","9":"instock","10":"sold-individually","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/110764","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/110765"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=110764"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=110764"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=110764"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}