{"id":110764,"date":"2024-10-18T16:00:09","date_gmt":"2024-10-18T16:00:09","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/icc-significantchangestoplbg-mech-ifgc-2012\/"},"modified":"2024-10-24T21:58:48","modified_gmt":"2024-10-24T21:58:48","slug":"icc-significantchangestoplbg-mech-ifgc-2012","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/icc\/icc-significantchangestoplbg-mech-ifgc-2012\/","title":{"rendered":"ICC SignificantChangestoPlbg Mech IFGC 2012"},"content":{"rendered":"
If you are sorting through a key code whether it is the International Plumbing, Mechanical, or Fuel Gas Codes<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
1<\/td>\n | Cover <\/td>\n<\/tr>\n | ||||||
4<\/td>\n | Contents <\/td>\n<\/tr>\n | ||||||
12<\/td>\n | PART 1 International Plumbing Code (Chapters 1 through 14) <\/td>\n<\/tr>\n | ||||||
15<\/td>\n | 202 Plumbing Fixture Definition <\/td>\n<\/tr>\n | ||||||
16<\/td>\n | 202 Plumbing Appliance Definition <\/td>\n<\/tr>\n | ||||||
17<\/td>\n | 202 Grease Interceptor Definition <\/td>\n<\/tr>\n | ||||||
19<\/td>\n | 303.1, 303.4 Material Identification and Third-Party Certification <\/td>\n<\/tr>\n | ||||||
21<\/td>\n | 308.9 Parallel Water Distribution Systems <\/td>\n<\/tr>\n | ||||||
22<\/td>\n | 315.1 Sealing of Annular Spaces at Penetrations <\/td>\n<\/tr>\n | ||||||
24<\/td>\n | Table 403.1 Minimum Number of Required Plumbing Fixtures <\/td>\n<\/tr>\n | ||||||
25<\/td>\n | 403.2 Separate Toilet Facilities in Group M Occupancies <\/td>\n<\/tr>\n | ||||||
27<\/td>\n | 403.2.1 Family or Assisted-Use Toilet Facilities Serving as Separate Facilities <\/td>\n<\/tr>\n | ||||||
28<\/td>\n | 403.3.2 Relationship of Toilet Rooms and Food Preparation Areas <\/td>\n<\/tr>\n | ||||||
30<\/td>\n | 403.3.6 Locking of Toilet Room Doors <\/td>\n<\/tr>\n | ||||||
31<\/td>\n | 403.5 Drinking Fountain Locations <\/td>\n<\/tr>\n | ||||||
32<\/td>\n | 405.3.1 Minimum Water Closet Compartment Size <\/td>\n<\/tr>\n | ||||||
34<\/td>\n | 405.4 Floor and Wall Drainage Connections <\/td>\n<\/tr>\n | ||||||
35<\/td>\n | 407.2 Bathtub Waste Outlets and Overflows <\/td>\n<\/tr>\n | ||||||
36<\/td>\n | 410 Minimum Required Number of Drinking Fountains <\/td>\n<\/tr>\n | ||||||
38<\/td>\n | 417.5.2.6 Shower Pan Liner Materials <\/td>\n<\/tr>\n | ||||||
39<\/td>\n | 424.9 Water Closet Personal Hygiene Devices <\/td>\n<\/tr>\n | ||||||
40<\/td>\n | 504.4.1 Water Heater Storage Tank Relief Valves <\/td>\n<\/tr>\n | ||||||
41<\/td>\n | 504.7 Water Heater Pans <\/td>\n<\/tr>\n | ||||||
42<\/td>\n | 605 Polyethylene of Raised-Temperature (PE-RT) Plastic Tubing <\/td>\n<\/tr>\n | ||||||
44<\/td>\n | Table 605.3 Polyethylene (PE) Water Service Pipe <\/td>\n<\/tr>\n | ||||||
45<\/td>\n | Table 605.3 PEX Water Service Pipe <\/td>\n<\/tr>\n | ||||||
46<\/td>\n | 606.7 Labeling of Water Distribution Pipes in Bundles <\/td>\n<\/tr>\n | ||||||
47<\/td>\n | 607.1.1 Water-Temperature-Limiting Means <\/td>\n<\/tr>\n | ||||||
48<\/td>\n | 607.2 Hot or Tempered Water Supply to Fixtures <\/td>\n<\/tr>\n | ||||||
49<\/td>\n | 607.5 Hot Water Piping Insulation <\/td>\n<\/tr>\n | ||||||
50<\/td>\n | 608.8 Identification of Nonpotable Water <\/td>\n<\/tr>\n | ||||||
51<\/td>\n | 704.3, 711.2.1 Horizontal Branch Connections <\/td>\n<\/tr>\n | ||||||
53<\/td>\n | Table 709.1 Drainage Fixture Units for Bathroom Groups <\/td>\n<\/tr>\n | ||||||
54<\/td>\n | 712.3.3 Sump Pump and Ejector Discharge Pipe and Fittings <\/td>\n<\/tr>\n | ||||||
55<\/td>\n | 712.3.5 Sump Pump Connection to the Drainage System <\/td>\n<\/tr>\n | ||||||
57<\/td>\n | 715.1 Fixture Protection from Sewage Backflow <\/td>\n<\/tr>\n | ||||||
59<\/td>\n | 802.1.8 Indirect Discharge of Food Preparation Sinks <\/td>\n<\/tr>\n | ||||||
60<\/td>\n | 802.2 Installation of Indirect Waste Piping <\/td>\n<\/tr>\n | ||||||
62<\/td>\n | 802.3 Prohibited Locations for Waste Receptors <\/td>\n<\/tr>\n | ||||||
64<\/td>\n | 901.3, 918.8 Air Admittance Valves for Chemical Waste Vent Systems <\/td>\n<\/tr>\n | ||||||
65<\/td>\n | 903.5 Location of Vent Terminals <\/td>\n<\/tr>\n | ||||||
66<\/td>\n | 915.2 Combination Waste and Vent System Sizing <\/td>\n<\/tr>\n | ||||||
67<\/td>\n | 917 Single-Stack Vent Systems <\/td>\n<\/tr>\n | ||||||
71<\/td>\n | 1002.1 Floor Drains in Multi-Level Parking Structures <\/td>\n<\/tr>\n | ||||||
72<\/td>\n | 1003.1 Interceptors and Separators <\/td>\n<\/tr>\n | ||||||
73<\/td>\n | 1003.3.1 Alternate Grease Interceptor Locations <\/td>\n<\/tr>\n | ||||||
74<\/td>\n | 1003.3.4 Hydromechanical Grease Interceptors <\/td>\n<\/tr>\n | ||||||
76<\/td>\n | 1105 Roof Drain Strainers <\/td>\n<\/tr>\n | ||||||
78<\/td>\n | 1107 Siphonic Roof Drainage Systems <\/td>\n<\/tr>\n | ||||||
80<\/td>\n | Chapter 13 Gray-Water Recycling Systems <\/td>\n<\/tr>\n | ||||||
83<\/td>\n | PART 2 International Mechanical Code (Chapters 1 through 15) <\/td>\n<\/tr>\n | ||||||
85<\/td>\n | 102.3 Maintenance <\/td>\n<\/tr>\n | ||||||
86<\/td>\n | 202 Environmental Air <\/td>\n<\/tr>\n | ||||||
87<\/td>\n | 306.5 Equipment and Appliances on Roofs or Elevated Structures <\/td>\n<\/tr>\n | ||||||
90<\/td>\n | 308.5 Labeled Assemblies <\/td>\n<\/tr>\n | ||||||
91<\/td>\n | 401.4 Intake Opening Location <\/td>\n<\/tr>\n | ||||||
93<\/td>\n | Table 403.3 Minimum Ventilation Rates for Nail Salons <\/td>\n<\/tr>\n | ||||||
94<\/td>\n | 404.1 Enclosed Parking Garages <\/td>\n<\/tr>\n | ||||||
95<\/td>\n | 501.2, 506.4 Independent Exhaust Systems Required <\/td>\n<\/tr>\n | ||||||
96<\/td>\n | 505.1 Domestic Kitchen Exhaust Systems <\/td>\n<\/tr>\n | ||||||
97<\/td>\n | 506.3.7.1 Grease Reservoirs <\/td>\n<\/tr>\n | ||||||
98<\/td>\n | 506.3.8 Grease Duct Cleanouts and Other Openings <\/td>\n<\/tr>\n | ||||||
100<\/td>\n | 506.3.9 Grease Duct Horizontal Cleanouts <\/td>\n<\/tr>\n | ||||||
101<\/td>\n | 506.3.10 Underground Grease Duct Installations <\/td>\n<\/tr>\n | ||||||
103<\/td>\n | 506.3.11.2 Field-Applied Grease Duct Enclosures <\/td>\n<\/tr>\n | ||||||
104<\/td>\n | 507.2 Type I or Type II Hood Required <\/td>\n<\/tr>\n | ||||||
105<\/td>\n | 507.2.1 Type I Hoods <\/td>\n<\/tr>\n | ||||||
106<\/td>\n | 507.2.1.1 Operation of Type I Hoods <\/td>\n<\/tr>\n | ||||||
108<\/td>\n | 507.2.1.2 Exhaust Flow Rate Label of Type I Hoods <\/td>\n<\/tr>\n | ||||||
109<\/td>\n | 507.2.2 Type II Hoods <\/td>\n<\/tr>\n | ||||||
110<\/td>\n | 507.10 Hoods Penetrating a Ceiling <\/td>\n<\/tr>\n | ||||||
111<\/td>\n | 510.7 Fire Suppression Required for Hazardous Exhaust Ducts <\/td>\n<\/tr>\n | ||||||
112<\/td>\n | 601.4 Contamination Prevention in Plenums <\/td>\n<\/tr>\n | ||||||
114<\/td>\n | 602.2.1 Materials within Plenums <\/td>\n<\/tr>\n | ||||||
116<\/td>\n | 603.7 Rigid Duct Penetrations <\/td>\n<\/tr>\n | ||||||
117<\/td>\n | 603.9 Duct Joints, Seams, and Connections <\/td>\n<\/tr>\n | ||||||
118<\/td>\n | 603.17, 202 Air Dispersion Systems <\/td>\n<\/tr>\n | ||||||
119<\/td>\n | 805.3 Factory-Built Chimney Offsets <\/td>\n<\/tr>\n | ||||||
120<\/td>\n | 901.4 Fireplace Accessories <\/td>\n<\/tr>\n | ||||||
121<\/td>\n | 928 Evaporative Cooling Equipment <\/td>\n<\/tr>\n | ||||||
122<\/td>\n | 1101.10 Locking Access Port Caps <\/td>\n<\/tr>\n | ||||||
123<\/td>\n | 1105.6, 1105.6.3 Machinery Room Ventilation <\/td>\n<\/tr>\n | ||||||
124<\/td>\n | 1106.4 Flammable Refrigerants <\/td>\n<\/tr>\n | ||||||
125<\/td>\n | PART 3 International Fuel Gas Code (Chapters 1 through 8) <\/td>\n<\/tr>\n | ||||||
127<\/td>\n | 202, 401.9, 401.10, 404.1 Identification, Testing and Certification <\/td>\n<\/tr>\n | ||||||
128<\/td>\n | 308.1 Clearance to Combustible materials <\/td>\n<\/tr>\n | ||||||
129<\/td>\n | 404.2 CSST piping systems <\/td>\n<\/tr>\n | ||||||
130<\/td>\n | 404.18 Prohibited Devices <\/td>\n<\/tr>\n | ||||||
131<\/td>\n | 408.4 Sediment Traps <\/td>\n<\/tr>\n | ||||||
132<\/td>\n | 410.4 Excess Flow Valves <\/td>\n<\/tr>\n | ||||||
133<\/td>\n | 202, 410.5 Flashback Arrestor Check Valve <\/td>\n<\/tr>\n | ||||||
134<\/td>\n | 618.4 Prohibited Sources <\/td>\n<\/tr>\n | ||||||
136<\/td>\n | Index A B C D <\/td>\n<\/tr>\n | ||||||
137<\/td>\n | E F G H <\/td>\n<\/tr>\n | ||||||
138<\/td>\n | I <\/td>\n<\/tr>\n | ||||||
139<\/td>\n | L M N O P <\/td>\n<\/tr>\n | ||||||
140<\/td>\n | R S <\/td>\n<\/tr>\n | ||||||
141<\/td>\n | T U V W <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" Significant Changes to the IPC, IMC, and IFGC, 2012 Edition<\/b><\/p>\n |