{"id":154661,"date":"2024-10-19T09:12:18","date_gmt":"2024-10-19T09:12:18","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/ieee-c37-23-2016\/"},"modified":"2024-10-25T01:27:49","modified_gmt":"2024-10-25T01:27:49","slug":"ieee-c37-23-2016","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/ieee\/ieee-c37-23-2016\/","title":{"rendered":"IEEE C37.23 2016"},"content":{"rendered":"
Revision Standard – Active. Metal-enclosed (ME) bus assemblies for indoor and outdoor use are discussed in this standard. The types of assemblies covered are nonsegregated-phase bus, cable bus, segregated-phase bus, and isolated-phase bus. Rated maximum voltages of ac ME bus assemblies range from 1058 V through 38 kV with continuous-current ratings of 600 A through 26 000 A for self-cooled ratings and up to 50 000 A for forced-cooled ratings. Rated maximum voltage levels of dc ME bus assemblies range from 300 V through 3200 V with continuous-current ratings of 600 A through 15 000 A. Service conditions, ratings, temperature limitations and classification of insulating materials, insulation (dielectric) withstand voltage requirements, test procedures, and application are discussed. A guide for calculating losses in isolated-phase bus is included.<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
1<\/td>\n | IEEE Std C37.23-2015 Front cover <\/td>\n<\/tr>\n | ||||||
2<\/td>\n | Title page <\/td>\n<\/tr>\n | ||||||
4<\/td>\n | Important Notices and Disclaimers Concerning IEEE Standards Documents <\/td>\n<\/tr>\n | ||||||
7<\/td>\n | Participants <\/td>\n<\/tr>\n | ||||||
9<\/td>\n | Introduction <\/td>\n<\/tr>\n | ||||||
11<\/td>\n | Contents <\/td>\n<\/tr>\n | ||||||
12<\/td>\n | IMPORTANT NOTICE 1. Overview 1.1 Scope 1.2 Purpose <\/td>\n<\/tr>\n | ||||||
13<\/td>\n | 2. Normative references <\/td>\n<\/tr>\n | ||||||
14<\/td>\n | 3. Definitions <\/td>\n<\/tr>\n | ||||||
17<\/td>\n | 4. Normal (usual) service conditions <\/td>\n<\/tr>\n | ||||||
18<\/td>\n | 5. Ratings 5.1 General 5.2 Voltage and insulation levels <\/td>\n<\/tr>\n | ||||||
20<\/td>\n | 5.3 Rated power frequency 5.4 Rated current <\/td>\n<\/tr>\n | ||||||
25<\/td>\n | 6. Tests 6.1 General <\/td>\n<\/tr>\n | ||||||
26<\/td>\n | 6.2 Design tests <\/td>\n<\/tr>\n | ||||||
35<\/td>\n | 6.3 Production tests <\/td>\n<\/tr>\n | ||||||
36<\/td>\n | 6.4 Field tests <\/td>\n<\/tr>\n | ||||||
37<\/td>\n | 7. Construction 7.1 Materials and finish <\/td>\n<\/tr>\n | ||||||
38<\/td>\n | 7.2 Grounding 7.3 Adjacent and supporting structure 7.4 Ventilation <\/td>\n<\/tr>\n | ||||||
39<\/td>\n | 7.5 Forced cooled <\/td>\n<\/tr>\n | ||||||
40<\/td>\n | 7.6 Vapor barriers 7.7 Fire barriers <\/td>\n<\/tr>\n | ||||||
41<\/td>\n | 7.8 Insulating materials for covering buses and connections 7.9 Terminations and flexible connections 7.10 Switches or links for station-service transformers 7.11 Secondary wiring <\/td>\n<\/tr>\n | ||||||
42<\/td>\n | 8. Miscellaneous accessories <\/td>\n<\/tr>\n | ||||||
44<\/td>\n | Annex A (normative) Cable bus A.1 General A.2 References A.3 Definitions A.4 Service conditions A.5 Ratings A.6 Tests <\/td>\n<\/tr>\n | ||||||
46<\/td>\n | A.7 Construction <\/td>\n<\/tr>\n | ||||||
49<\/td>\n | Annex B (informative) Guide for calculating losses in isolated-phase bus B.1 General B.2 Conductor losses <\/td>\n<\/tr>\n | ||||||
51<\/td>\n | B.3 Skin effects <\/td>\n<\/tr>\n | ||||||
55<\/td>\n | B.4 Enclosure losses <\/td>\n<\/tr>\n | ||||||
62<\/td>\n | B.5 Power consumption of cooling equipment B.6 Sample solutions <\/td>\n<\/tr>\n | ||||||
70<\/td>\n | B.7 Structural steel losses <\/td>\n<\/tr>\n | ||||||
71<\/td>\n | Annex C (informative) Application guide for ME bus in unusual service conditions C.1 General C.2 Ambient air temperature above 40 \u00b0C C.3 Ambient air temperature below \u201330 \u00b0C C.4 Application at unusual altitudes <\/td>\n<\/tr>\n | ||||||
72<\/td>\n | C.5 Other conditions that may affect design and application <\/td>\n<\/tr>\n | ||||||
73<\/td>\n | C.6 Modification of equipment for unusual environment <\/td>\n<\/tr>\n | ||||||
75<\/td>\n | Annex D (informative) Guide for handling, storage, and installation D.1 General D.2 Handling <\/td>\n<\/tr>\n | ||||||
77<\/td>\n | D.3 Pre-operation check <\/td>\n<\/tr>\n | ||||||
78<\/td>\n | Annex E (informative) Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" IEEE Standard for Metal-Enclosed Bus<\/b><\/p>\n |