{"id":166892,"date":"2024-10-19T10:08:19","date_gmt":"2024-10-19T10:08:19","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/fema-e-74-2012\/"},"modified":"2024-10-25T02:27:04","modified_gmt":"2024-10-25T02:27:04","slug":"fema-e-74-2012","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/fema\/fema-e-74-2012\/","title":{"rendered":"FEMA E 74 2012"},"content":{"rendered":"
None<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
1<\/td>\n | 0-82 00_FEMAE-74-Cover <\/td>\n<\/tr>\n | ||||||
2<\/td>\n | 1-82 01_FEMAE-74-Preface <\/td>\n<\/tr>\n | ||||||
3<\/td>\n | 02_FEMAE-74-TableofContents <\/td>\n<\/tr>\n | ||||||
6<\/td>\n | 03_FEMAE-74_Chapter1 <\/td>\n<\/tr>\n | ||||||
13<\/td>\n | 04_FEMAE-74-Chapter2 <\/td>\n<\/tr>\n | ||||||
42<\/td>\n | 5-82.pdf 05_FEMAE-74_Chapter3 3.1 Survey of Nonstructural Components <\/td>\n<\/tr>\n | ||||||
44<\/td>\n | 3.1.1 Survey Forms <\/td>\n<\/tr>\n | ||||||
47<\/td>\n | 3.2 Estimating Seismic Risk 3.2.1 Estimating Seismic Shaking Intensity <\/td>\n<\/tr>\n | ||||||
50<\/td>\n | 3.2.2 Estimating Seismic Risk Ratings <\/td>\n<\/tr>\n | ||||||
51<\/td>\n | 3.2.3 Assigning Priority Ratings 3.2.4 Application of Nonstructural Guidelines <\/td>\n<\/tr>\n | ||||||
53<\/td>\n | 06_FEMAE_74_Chapter4 4.1 Program Objectives and Scope <\/td>\n<\/tr>\n | ||||||
54<\/td>\n | 4.1.1 Voluntary vs. Mandatory Risk Reduction <\/td>\n<\/tr>\n | ||||||
55<\/td>\n | 4.1.2 Performance-Based Design Concepts <\/td>\n<\/tr>\n | ||||||
62<\/td>\n | 4.1.3 Legal Considerations <\/td>\n<\/tr>\n | ||||||
63<\/td>\n | 4.2 Design considerations <\/td>\n<\/tr>\n | ||||||
65<\/td>\n | 4.3 Project planning and implementation strategies <\/td>\n<\/tr>\n | ||||||
67<\/td>\n | 4.3.1 Integration with Maintenance Programs 4.3.2 Integration with Remodeling <\/td>\n<\/tr>\n | ||||||
68<\/td>\n | 4.3.3 Phased or Incremental Upgrading 4.3.4 Integration with Purchasing 4.4 Responsibility and Program Management 4.4.1 Responsibility <\/td>\n<\/tr>\n | ||||||
72<\/td>\n | 4.4.2 Sustaining Protection 4.4.3 Program Evaluation <\/td>\n<\/tr>\n | ||||||
73<\/td>\n | 4.5 Cost benchmarks \u2013 Examples 4.5.1 Example 1 \u2013 Manufacturing Facility <\/td>\n<\/tr>\n | ||||||
74<\/td>\n | 4.5.2 Example 2 \u2013 School District <\/td>\n<\/tr>\n | ||||||
75<\/td>\n | 4.5.3 Example 3 \u2013 California Hospital <\/td>\n<\/tr>\n | ||||||
77<\/td>\n | 07_FEMAE-74_Chapter5 5.1 Program Objectives and Scope <\/td>\n<\/tr>\n | ||||||
79<\/td>\n | 5.1.1 Voluntary vs Mandatory Risk Reduction <\/td>\n<\/tr>\n | ||||||
80<\/td>\n | 5.1.2 Performance-Based Design concepts <\/td>\n<\/tr>\n | ||||||
82<\/td>\n | 5.2 Design Considerations <\/td>\n<\/tr>\n | ||||||
83<\/td>\n | 5.3 Building code requirements 5.3.1 2012 Edition of the International building code (IBC 2012) <\/td>\n<\/tr>\n | ||||||
87<\/td>\n | 5.3.2 Enforcement of Code Requirements <\/td>\n<\/tr>\n | ||||||
88<\/td>\n | Plan Review Construction Inspection <\/td>\n<\/tr>\n | ||||||
89<\/td>\n | 5.3.3 Requirements for Contents 5.3.4 Other Standards and Protocols <\/td>\n<\/tr>\n | ||||||
90<\/td>\n | 5.3.5 Validation and Refinement of Code Requirements 5.4 Responsibility and Project Management <\/td>\n<\/tr>\n | ||||||
92<\/td>\n | 5.4.1 Example: Responsibility Matrix <\/td>\n<\/tr>\n | ||||||
93<\/td>\n | 5.4.2 Example: Seismic Code Block, Saint Louis county, Missouri <\/td>\n<\/tr>\n | ||||||
95<\/td>\n | 08_FEMAE-74_Chapter6_part1 6.1 Protective Measures 6.1.1 Common Sense Measures <\/td>\n<\/tr>\n | ||||||
96<\/td>\n | 6.1.2 Nonstructural Component Protection Measures <\/td>\n<\/tr>\n | ||||||
98<\/td>\n | 6.1.3 building Protection Measures <\/td>\n<\/tr>\n | ||||||
99<\/td>\n | 6.2 Nonstructural Component examples <\/td>\n<\/tr>\n | ||||||
100<\/td>\n | 6.2.1 Typical Mitigation Details Non-Engineered (NE) Details Prescriptive (PR) Details <\/td>\n<\/tr>\n | ||||||
101<\/td>\n | Engineering Required (ER) Details <\/td>\n<\/tr>\n | ||||||
105<\/td>\n | 09_FEMAE-74_Chapter6_3_1_1 6.3 Architectural Components 6.3.1 Exterior Wall Components 6.3.1.1 Adhered Veneer Provisions BUILDING CODE PROVISIONS Retrofit standard Provisions <\/td>\n<\/tr>\n | ||||||
106<\/td>\n | Typical Causes of Damage <\/td>\n<\/tr>\n | ||||||
107<\/td>\n | Damage Examples <\/td>\n<\/tr>\n | ||||||
110<\/td>\n | Seismic Mitigation Considerations <\/td>\n<\/tr>\n | ||||||
111<\/td>\n | Mitigation Examples <\/td>\n<\/tr>\n | ||||||
112<\/td>\n | Mitigation Details <\/td>\n<\/tr>\n | ||||||
113<\/td>\n | 10_FEMAE-74-Chapter6_3_1_2 6.3 Architectural Components 6.3.1 Exterior Wall Components 6.3.1.2 Anchored Veneer Provisions Building Code Provisions <\/td>\n<\/tr>\n | ||||||
114<\/td>\n | Retrofit Standard Provisions Typical Causes of Damage <\/td>\n<\/tr>\n | ||||||
115<\/td>\n | Damage Examples <\/td>\n<\/tr>\n | ||||||
117<\/td>\n | Seismic Mitigation Considerations Mitigation Examples <\/td>\n<\/tr>\n | ||||||
118<\/td>\n | Mitigation Details <\/td>\n<\/tr>\n | ||||||
119<\/td>\n | 11_FEMAE-74-Chapter6_3_1_3 6.3 Architectural Components 6.3.1 Exterior Wall Components 6.3.1.3 Prefabricated Panels Provisions Building Code Provisions Retrofit Standard Provisions <\/td>\n<\/tr>\n | ||||||
120<\/td>\n | Typical Causes of Damage <\/td>\n<\/tr>\n | ||||||
121<\/td>\n | Damage Examples <\/td>\n<\/tr>\n | ||||||
127<\/td>\n | Seismic Mitigation Considerations <\/td>\n<\/tr>\n | ||||||
130<\/td>\n | Mitigation Details <\/td>\n<\/tr>\n | ||||||
132<\/td>\n | 12_FEMAE-74-Chapter6_3_1_4 6.3 Architectural Components 6.3.1 Exterior Wall Components 6.3.1.4 Glazing Provisions Building Code Provisions Retrofit Standard Provisions <\/td>\n<\/tr>\n | ||||||
133<\/td>\n | Typical Causes of Damage <\/td>\n<\/tr>\n | ||||||
134<\/td>\n | Damage Examples <\/td>\n<\/tr>\n | ||||||
140<\/td>\n | Seismic Mitigation Considerations <\/td>\n<\/tr>\n | ||||||
141<\/td>\n | Mitigation Details <\/td>\n<\/tr>\n | ||||||
142<\/td>\n | 13_FEMAE-74-Chapter6_3_1_5 6.3 Architectural Components 6.3.1 Exterior Wall Components 6.3.1.5 Glass block Provisions Building Code Provisions Retrofit Standard Provisions <\/td>\n<\/tr>\n | ||||||
143<\/td>\n | Typical Causes of Damage <\/td>\n<\/tr>\n | ||||||
144<\/td>\n | Damage Examples <\/td>\n<\/tr>\n | ||||||
146<\/td>\n | Seismic Mitigation Considerations <\/td>\n<\/tr>\n | ||||||
148<\/td>\n | Mitigation Examples <\/td>\n<\/tr>\n | ||||||
150<\/td>\n | Mitigation Details <\/td>\n<\/tr>\n | ||||||
152<\/td>\n | 14_FEMAE-74-Chapter6_3_2_1 6.3 Architectural Components 6.3.2 Interior Partitions 6.3.2.1 Interior Partition Walls, Heavy Provisions Building Code Provisions Retrofit Standard Provisions <\/td>\n<\/tr>\n | ||||||
153<\/td>\n | Typical Causes of Damage <\/td>\n<\/tr>\n | ||||||
154<\/td>\n | Damage Examples <\/td>\n<\/tr>\n | ||||||
158<\/td>\n | Seismic Mitigation Considerations <\/td>\n<\/tr>\n | ||||||
159<\/td>\n | Mitigation Examples <\/td>\n<\/tr>\n | ||||||
161<\/td>\n | Mitigation Details <\/td>\n<\/tr>\n | ||||||
163<\/td>\n | 15_FEMAE-74-Chapter6_3_2_2 6.3 Architectural Components 6.3.2 Interior Partitions 6.3.2.2 Interior Partition Walls, Light Provisions Building Code Provisions <\/td>\n<\/tr>\n | ||||||
164<\/td>\n | Retrofit Standard Provisions Typical Causes of Damage <\/td>\n<\/tr>\n | ||||||
166<\/td>\n | Damage Examples <\/td>\n<\/tr>\n | ||||||
170<\/td>\n | Seismic Mitigation Considerations <\/td>\n<\/tr>\n | ||||||
171<\/td>\n | Mitigation Examples <\/td>\n<\/tr>\n | ||||||
172<\/td>\n | Mitigation Details <\/td>\n<\/tr>\n | ||||||
174<\/td>\n | 16_FEMAE-74-Chapter6_3_2_3 6.3 Architectural Components 6.3.2 Interior Partitions 6.3.2.3 Glazed Partitions Provisions Building Code Provisions Retrofit Standard Provisions <\/td>\n<\/tr>\n | ||||||
175<\/td>\n | Typical Causes of Damage <\/td>\n<\/tr>\n | ||||||
176<\/td>\n | Damage Examples <\/td>\n<\/tr>\n | ||||||
178<\/td>\n | Seismic Mitigation Considerations <\/td>\n<\/tr>\n | ||||||
180<\/td>\n | Mitigation Examples <\/td>\n<\/tr>\n | ||||||
182<\/td>\n | Mitigation Details <\/td>\n<\/tr>\n | ||||||
183<\/td>\n | 17_FEMAE-74-Chapter6_3_3_1 6.3 ARCHITECTURAL COMPONENTS 6.3.3 Interior Veneers 6.3.3.1 Stone, Tile and Masonry Veneer Provisions Building Code Provisions Retrofit Standard Provisions <\/td>\n<\/tr>\n | ||||||
184<\/td>\n | Typical causes of damage Damage Examples <\/td>\n<\/tr>\n | ||||||
186<\/td>\n | Seismic Mitigation Considerations <\/td>\n<\/tr>\n | ||||||
187<\/td>\n | Mitigation Details <\/td>\n<\/tr>\n | ||||||
188<\/td>\n | 18_FEMAE-74-Chapter6_3_4_1 6.3 Architectural Components 6.3.4 Ceilings 6.3.4.1 Suspended Lay-in Tile Ceiling Systems Provisions Building Code Provisions Retrofit Standard Provisions <\/td>\n<\/tr>\n | ||||||
189<\/td>\n | Typical Causes of Damage <\/td>\n<\/tr>\n | ||||||
190<\/td>\n | Damage Examples <\/td>\n<\/tr>\n | ||||||
194<\/td>\n | Seismic Mitigation Considerations <\/td>\n<\/tr>\n | ||||||
197<\/td>\n | Mitigation Examples <\/td>\n<\/tr>\n | ||||||
198<\/td>\n | Mitigation Details <\/td>\n<\/tr>\n | ||||||
202<\/td>\n | 19_FEMAE-74-Chapter6_3_4_2 6.3 Architectural Components 6.3.4 Ceilings 6.3.4.2 Ceilings applied Directly to Structure Provisions Building Code Provisions Retrofit Standard Provisions <\/td>\n<\/tr>\n | ||||||
203<\/td>\n | Typical Causes of Damage <\/td>\n<\/tr>\n | ||||||
204<\/td>\n | Damage Examples <\/td>\n<\/tr>\n | ||||||
208<\/td>\n | Seismic Mitigation Considerations <\/td>\n<\/tr>\n | ||||||
209<\/td>\n | Mitigation Examples <\/td>\n<\/tr>\n | ||||||
211<\/td>\n | Mitigation Details <\/td>\n<\/tr>\n | ||||||
213<\/td>\n | 20_FEMAE-74-Chapter6_3_4_3 6.3 Architectural Components 6.3.4 Ceilings 6.3.4.3 Suspended Heavy Ceilings Provisions Building Code Provisions <\/td>\n<\/tr>\n | ||||||
214<\/td>\n | Retrofit Standard Provisions Typical Causes of Damage <\/td>\n<\/tr>\n | ||||||
215<\/td>\n | Damage Examples <\/td>\n<\/tr>\n | ||||||
217<\/td>\n | Seismic Mitigation Considerations <\/td>\n<\/tr>\n | ||||||
219<\/td>\n | Mitigation Examples <\/td>\n<\/tr>\n | ||||||
220<\/td>\n | Mitigation Details <\/td>\n<\/tr>\n | ||||||
223<\/td>\n | 21_FEMAE-74-Chapter6_3_5_1 6.3 Architectural Components 6.3.5 Parapets and Appendages 6.3.5.1 Unreinforced Masonry Parapets Provisions Building Code Provisions Retrofit Standard Provisions Typical Causes of Damage <\/td>\n<\/tr>\n | ||||||
224<\/td>\n | Damage Examples <\/td>\n<\/tr>\n | ||||||
226<\/td>\n | Seismic Mitigation Considerations Mitigation Examples <\/td>\n<\/tr>\n | ||||||
228<\/td>\n | Mitigation Details <\/td>\n<\/tr>\n | ||||||
229<\/td>\n | 22_FEMAE-74-Chapter6_3_6_1 6.3 Architectural Components 6.3.6 Canopies, Marquees, and Signs 6.3.6.1 Canopies, Marquees, and Signs Provisions Building Code Provisions Retrofit Standard Provisions Typical Causes of Damage <\/td>\n<\/tr>\n | ||||||
230<\/td>\n | Damage Examples <\/td>\n<\/tr>\n | ||||||
231<\/td>\n | Seismic Mitigation Considerations Mitigation Details <\/td>\n<\/tr>\n | ||||||
232<\/td>\n | 23_FEMAE-74-Chapter6_3_7_1 6.3 Architectural Components 6.3.7 Chimneys and Stacks 6.3.7.1 Unreinforced Masonry Chimney Provisions Building Code Provisions Retrofit Standard Provisions Typical Causes of Damage <\/td>\n<\/tr>\n | ||||||
233<\/td>\n | Damage Examples <\/td>\n<\/tr>\n | ||||||
235<\/td>\n | Seismic Mitigation Considerations <\/td>\n<\/tr>\n | ||||||
236<\/td>\n | Mitigation Examples Mitigation Details <\/td>\n<\/tr>\n | ||||||
237<\/td>\n | 24_FEMAE-74-Chapter6_3_8_1 6.3 Architectural Components 6.3.8 Stairways 6.3.8.1 Stairways Provisions Building Code Provisions Retrofit Standard Provisions <\/td>\n<\/tr>\n | ||||||
238<\/td>\n | Typical Causes of Damage <\/td>\n<\/tr>\n | ||||||
239<\/td>\n | Damage Examples <\/td>\n<\/tr>\n | ||||||
243<\/td>\n | Seismic Mitigation Considerations <\/td>\n<\/tr>\n | ||||||
244<\/td>\n | Mitigation Details <\/td>\n<\/tr>\n | ||||||
247<\/td>\n | 25_FEMAE-74-Chapter6_3_9_1 6.3 Architectural Components 6.3.9 Freestanding Walls or Fences 6.3.9.1 Freestanding Masonry Wall or Fence Typical Causes of Damage <\/td>\n<\/tr>\n | ||||||
248<\/td>\n | Damage Examples <\/td>\n<\/tr>\n | ||||||
251<\/td>\n | Seismic Mitigation Considerations <\/td>\n<\/tr>\n | ||||||
253<\/td>\n | Mitigation Details <\/td>\n<\/tr>\n | ||||||
255<\/td>\n | 26_FEMAE-74-Chapter6_4_1_1 6.4 Mechanical, Electrical, and Plumbing Components <\/td>\n<\/tr>\n | ||||||
256<\/td>\n | 6.4.1 Mechanical Equipment 6.4.1.1 Boilers, Furnaces, Pumps, and Chillers Provisions Building Code Provisions <\/td>\n<\/tr>\n | ||||||
257<\/td>\n | Retrofit Standard Provisions Typical Causes of Damage <\/td>\n<\/tr>\n | ||||||
258<\/td>\n | Damage Examples <\/td>\n<\/tr>\n | ||||||
259<\/td>\n | Seismic Mitigation Considerations <\/td>\n<\/tr>\n | ||||||
260<\/td>\n | Mitigation Examples <\/td>\n<\/tr>\n | ||||||
262<\/td>\n | Mitigation Details <\/td>\n<\/tr>\n | ||||||
264<\/td>\n | 27_FEMAE-74-Chapter6_4_1_2 6.4 Mechanical, Electrical, and Plumbing Components 6.4.1 Mechanical Equipment 6.4.1.2 General Manufacturing and Process Machinery Provisions Building Code Provisions <\/td>\n<\/tr>\n | ||||||
265<\/td>\n | Retrofit Standard Provisions <\/td>\n<\/tr>\n | ||||||
266<\/td>\n | Typical Causes of Damage <\/td>\n<\/tr>\n | ||||||
267<\/td>\n | Damage Examples <\/td>\n<\/tr>\n | ||||||
269<\/td>\n | Seismic Mitigation Considerations <\/td>\n<\/tr>\n | ||||||
270<\/td>\n | 28-82.pdf 28_FEMAE-74-Chapter6_4_1_3 6.4 Mechanical, Electrical, and Plumbing Components 6.4.1 Mechanical Equipment 6.4.1.3 HVAC Equipment with Vibration Isolation Provisions Building Code Provisions Retrofit Standard Provisions <\/td>\n<\/tr>\n | ||||||
271<\/td>\n | Typical Causes of Damage <\/td>\n<\/tr>\n | ||||||
272<\/td>\n | Damage Examples <\/td>\n<\/tr>\n | ||||||
274<\/td>\n | Seismic Mitigation Considerations <\/td>\n<\/tr>\n | ||||||
276<\/td>\n | Mitigation Examples <\/td>\n<\/tr>\n | ||||||
278<\/td>\n | Mitigation Details <\/td>\n<\/tr>\n | ||||||
279<\/td>\n | 29_FEMAE-74-Chapter6_4_1_4 6.4 Mechanical, Electrical, and Plumbing Components 6.4.1 Mechanical Equipment 6.4.1.4 HVAC Equipment without External Vibration Isolation Provisions Building Code Provisions Retrofit Standard Provisions <\/td>\n<\/tr>\n | ||||||
280<\/td>\n | Typical Causes of Damage Damage Examples <\/td>\n<\/tr>\n | ||||||
282<\/td>\n | Seismic Mitigation Considerations <\/td>\n<\/tr>\n | ||||||
283<\/td>\n | Mitigation Details <\/td>\n<\/tr>\n | ||||||
284<\/td>\n | 30_FEMAE-74-Chapter6_4_1_5 6.4 Mechanical, Electrical, and Plumbing Components 6.4.1 Mechanical Equipment 6.4.1.5 HVAC Equipment Suspended In-Line with Ductwork Provisions Building Code Provisions <\/td>\n<\/tr>\n | ||||||
285<\/td>\n | Retrofit Standard Provisions Typical Causes of Damage <\/td>\n<\/tr>\n | ||||||
286<\/td>\n | Damage Examples <\/td>\n<\/tr>\n | ||||||
288<\/td>\n | Seismic Mitigation Considerations Mitigation Examples <\/td>\n<\/tr>\n | ||||||
289<\/td>\n | Mitigation Details <\/td>\n<\/tr>\n | ||||||
292<\/td>\n | 31_FEMAE-74-Chapter6_4_1_6 6.4 Mechanical, Electrical, and Plumbing Components 6.4.1 Mechanical Equipment 6.4.1.6 Suspended Equipment Provisions Building Code Provisions Retrofit Standard Provisions Typical Causes of Damage <\/td>\n<\/tr>\n | ||||||
293<\/td>\n | Damage Examples <\/td>\n<\/tr>\n | ||||||
294<\/td>\n | Seismic Mitigation Considerations <\/td>\n<\/tr>\n | ||||||
295<\/td>\n | Mitigation Details <\/td>\n<\/tr>\n | ||||||
296<\/td>\n | 32_FEMAE-74-Chapter6_4_2_1 6.4 Mechanical, Electrical, and Plumbing Components 6.4.2 Storage Tanks and Water Heaters 6.4.2.1 Structurally Supported Tanks and Vessels Provisions Building Code Provisions <\/td>\n<\/tr>\n | ||||||
297<\/td>\n | Retrofit Standard Provisions Typical Causes of Damage <\/td>\n<\/tr>\n | ||||||
298<\/td>\n | Damage Examples <\/td>\n<\/tr>\n | ||||||
301<\/td>\n | Seismic Mitigation Considerations <\/td>\n<\/tr>\n | ||||||
302<\/td>\n | Mitigation Examples <\/td>\n<\/tr>\n | ||||||
304<\/td>\n | Mitigation Details <\/td>\n<\/tr>\n | ||||||
305<\/td>\n | 33_FEMAE-74-Chapter6_4_2_2 6.4 Mechanical, Electrical, and Plumbing Components 6.4.2 Storage Tanks and Water Heaters 6.4.2.2 Flat Bottom Tanks and Vessels Provisions Building Code Provisions <\/td>\n<\/tr>\n | ||||||
306<\/td>\n | Retrofit Standard Provisions Typical Causes of Damage <\/td>\n<\/tr>\n | ||||||
307<\/td>\n | Damage Examples <\/td>\n<\/tr>\n | ||||||
310<\/td>\n | Seismic Mitigation Considerations <\/td>\n<\/tr>\n | ||||||
311<\/td>\n | Mitigation Examples <\/td>\n<\/tr>\n | ||||||
314<\/td>\n | Mitigation Details <\/td>\n<\/tr>\n | ||||||
315<\/td>\n | 34_FEMAE-74-Chapter6_4_2_3 6.4 Mechanical, Electrical, and Plumbing Components 6.4.2 Storage Tanks and Water Heaters 6.4.2.3 Compressed Gas Cylinders Provisions Building Code Provisions Retrofit Standard Provisions Typical Causes of Damage <\/td>\n<\/tr>\n | ||||||
316<\/td>\n | Damage Examples Seismic Mitigation Considerations <\/td>\n<\/tr>\n | ||||||
317<\/td>\n | Mitigation Examples <\/td>\n<\/tr>\n | ||||||
320<\/td>\n | Mitigation Details <\/td>\n<\/tr>\n | ||||||
321<\/td>\n | 35_FEMAE-74_Chapter6_4_2_4 <\/td>\n<\/tr>\n | ||||||
330<\/td>\n | 36_FEMAE-74-Chapter6_4_3_1 6.4 Mechanical, Electrical, and Plumbing Components 6.4.3 Pressure piping 6.4.3.1 Suspended Pressure Piping Provisions Building Code Provisions <\/td>\n<\/tr>\n | ||||||
331<\/td>\n | Retrofit Standards Provisions Typical Causes of Damage <\/td>\n<\/tr>\n | ||||||
332<\/td>\n | Damage Examples <\/td>\n<\/tr>\n | ||||||
335<\/td>\n | Seismic Mitigation Considerations <\/td>\n<\/tr>\n | ||||||
336<\/td>\n | Mitigation Examples <\/td>\n<\/tr>\n | ||||||
339<\/td>\n | Mitigation Details <\/td>\n<\/tr>\n | ||||||
344<\/td>\n | 37_FEMAE-74-Chapter6_4_3_2 6.4 Mechanical, Electrical, and Plumbing Components 6.4.3 Pressure Piping 6.4.3.2 In-Line Valves and Pumps Provisions Building Code Provisions <\/td>\n<\/tr>\n | ||||||
345<\/td>\n | Retrofit Standard Provisions Typical Causes of Damage Seismic Mitigation Considerations <\/td>\n<\/tr>\n | ||||||
347<\/td>\n | Mitigation Examples <\/td>\n<\/tr>\n | ||||||
348<\/td>\n | Mitigation Details <\/td>\n<\/tr>\n | ||||||
351<\/td>\n | 38_FEMAE-74-Chapter6_4_3_3 6.4 Mechanical, Electrical, and Plumbing Components 6.4.3 Pressure piping 6.4.3.3 Flexible Connections, Expansion Joints, and Seismic Separations Provisions Building Code Provisions Retrofit Standard Provisions <\/td>\n<\/tr>\n | ||||||
352<\/td>\n | Typical Causes of Damage Damage Examples <\/td>\n<\/tr>\n | ||||||
353<\/td>\n | Seismic Mitigation Considerations <\/td>\n<\/tr>\n | ||||||
354<\/td>\n | Mitigation Examples <\/td>\n<\/tr>\n | ||||||
357<\/td>\n | Mitigation Details <\/td>\n<\/tr>\n | ||||||
358<\/td>\n | 39_FEMAE-74-Chapter6_4_3_4 6.4 Mechanical, Electrical, and Plumbing Components 6.4.3 Pressure Piping 6.4.3.4 Pipe Risers Provisions Building Code Provisions Retrofit Standard Provisions Typical Causes of Damage <\/td>\n<\/tr>\n | ||||||
360<\/td>\n | Damage Examples Seismic Mitigation Considerations <\/td>\n<\/tr>\n | ||||||
362<\/td>\n | Mitigation Examples <\/td>\n<\/tr>\n | ||||||
365<\/td>\n | Mitigation Details <\/td>\n<\/tr>\n | ||||||
369<\/td>\n | 40_FEMAE-74-Chapter6_4_3_5 6.4 Mechanical, Electrical, and Plumbing Components 6.4.3 Pressure Piping 6.4.3.5 Floor-mounted supports Provisions Building Code Provisions <\/td>\n<\/tr>\n | ||||||
370<\/td>\n | Retrofit Standard Provisions Typical Causes of Damage <\/td>\n<\/tr>\n | ||||||
371<\/td>\n | Damage Examples <\/td>\n<\/tr>\n | ||||||
372<\/td>\n | Seismic Mitigation Considerations <\/td>\n<\/tr>\n | ||||||
373<\/td>\n | Mitigation Examples <\/td>\n<\/tr>\n | ||||||
376<\/td>\n | Mitigation Details <\/td>\n<\/tr>\n | ||||||
379<\/td>\n | 41_FEMAE-74-Chapter6_4_3_6 6.4 Mechanical, Electrical, and Plumbing Components 6.4.3 Pressure Piping 6.4.3.6 Roof-Mounted Supports Provisions Building Code Provisions <\/td>\n<\/tr>\n | ||||||
380<\/td>\n | Retrofit Standard Provisions Typical Causes of Damage <\/td>\n<\/tr>\n | ||||||
381<\/td>\n | Damage Examples <\/td>\n<\/tr>\n | ||||||
383<\/td>\n | Seismic Mitigation Considerations <\/td>\n<\/tr>\n | ||||||
384<\/td>\n | Mitigation Examples <\/td>\n<\/tr>\n | ||||||
385<\/td>\n | Mitigation Details <\/td>\n<\/tr>\n | ||||||
387<\/td>\n | 42_FEMAE-74-Chapter6_4_3_7 6.4 Mechanical, Electrical, and Plumbing Components 6.4.3 Pressure Piping 6.4.3.7 Wall-Mounted Supports Provisions Building Code Provisions <\/td>\n<\/tr>\n | ||||||
388<\/td>\n | Retrofit Standard Provisions Typical Causes of Damage <\/td>\n<\/tr>\n | ||||||
389<\/td>\n | Damage Examples <\/td>\n<\/tr>\n | ||||||
390<\/td>\n | Seismic Mitigation Considerations <\/td>\n<\/tr>\n | ||||||
391<\/td>\n | Mitigation Examples <\/td>\n<\/tr>\n | ||||||
392<\/td>\n | Mitigation Details <\/td>\n<\/tr>\n | ||||||
396<\/td>\n | 43_FEMAE-74-Chapter6_4_3_8 6.4 Mechanical, Electrical, and Plumbing Components 6.4.3 Pressure Piping 6.4.3.8 Penetrations Provisions Building Code Provisions Retrofit Standard Provisions <\/td>\n<\/tr>\n | ||||||
397<\/td>\n | Typical Causes of Damage <\/td>\n<\/tr>\n | ||||||
398<\/td>\n | Damage Examples <\/td>\n<\/tr>\n | ||||||
401<\/td>\n | Seismic Mitigation Considerations <\/td>\n<\/tr>\n | ||||||
402<\/td>\n | Mitigation Examples <\/td>\n<\/tr>\n | ||||||
405<\/td>\n | Mitigation Details <\/td>\n<\/tr>\n | ||||||
407<\/td>\n | 44_FEMAE-74-Chapter6_4_4_1 6.4 Mechanical, Electrical, and Plumbing Components 6.4.4 Fire Protection piping 6.4.4.1 Suspended Fire Protection Piping Provisions Building Code Provisions <\/td>\n<\/tr>\n | ||||||
408<\/td>\n | Retrofit Standard Provisions Typical Causes of Damage <\/td>\n<\/tr>\n | ||||||
410<\/td>\n | Damage Examples <\/td>\n<\/tr>\n | ||||||
414<\/td>\n | Seismic Mitigation Considerations <\/td>\n<\/tr>\n | ||||||
415<\/td>\n | Mitigation Examples <\/td>\n<\/tr>\n | ||||||
417<\/td>\n | Mitigation Details <\/td>\n<\/tr>\n | ||||||
418<\/td>\n | 45_FEMAE-74-Chapter6_4_5_1 6.4 Mechanical, Electrical, and Plumbing Components 6.4.5 Fluid Piping, not Fire Protection 6.4.5.1 Hazardous Materials Piping Provisions Building Code Provisions Retrofit Standard Provisions <\/td>\n<\/tr>\n | ||||||
419<\/td>\n | Typical Causes of Damage <\/td>\n<\/tr>\n | ||||||
420<\/td>\n | Damage Examples <\/td>\n<\/tr>\n | ||||||
423<\/td>\n | Seismic Mitigation Considerations <\/td>\n<\/tr>\n | ||||||
425<\/td>\n | Mitigation Examples <\/td>\n<\/tr>\n | ||||||
430<\/td>\n | Mitigation Details <\/td>\n<\/tr>\n | ||||||
431<\/td>\n | 46_FEMAE-74-Chapter6_4_5_2 6.4 Mechanical, Electrical, and Plumbing Components 6.4.5 Fluid Piping, not Fire Protection 6.4.5.2 Nonhazardous Materials Piping Provisions Building Code Provisions <\/td>\n<\/tr>\n | ||||||
432<\/td>\n | Retrofit Standard Provisions Typical Causes of Damage <\/td>\n<\/tr>\n | ||||||
433<\/td>\n | Damage Examples <\/td>\n<\/tr>\n | ||||||
436<\/td>\n | Seismic Mitigation Considerations Mitigation Examples <\/td>\n<\/tr>\n | ||||||
439<\/td>\n | 47_FEMAE-74-Chapter6_4_6_1 6.4 Mechanical, Electrical, and Plumbing Components 6.4.6 Ductwork 6.4.6.1 Suspended Ductwork Provisions Building Code Provisions <\/td>\n<\/tr>\n | ||||||
440<\/td>\n | Retrofit Standard Provisions Typical Causes of Damage <\/td>\n<\/tr>\n | ||||||
441<\/td>\n | Damage Examples <\/td>\n<\/tr>\n | ||||||
443<\/td>\n | Seismic Mitigation Considerations <\/td>\n<\/tr>\n | ||||||
444<\/td>\n | Mitigation Examples <\/td>\n<\/tr>\n | ||||||
447<\/td>\n | Mitigation Details <\/td>\n<\/tr>\n | ||||||
449<\/td>\n | 48-82.pdf 48_FEMAE-74-Chapter6_4_6_2 6.4 Mechanical, Electrical, and Plumbing Components 6.4.6 Ductwork 6.4.6.2 Air Diffusers Provisions Building Code Provisions Retrofit Standard Provisions Typical Causes of Damage <\/td>\n<\/tr>\n | ||||||
450<\/td>\n | Damage Examples <\/td>\n<\/tr>\n | ||||||
451<\/td>\n | Seismic Mitigation Considerations <\/td>\n<\/tr>\n | ||||||
452<\/td>\n | Mitigation Details <\/td>\n<\/tr>\n | ||||||
453<\/td>\n | 49_FEMAE-74-Chapter6_4_7_1 6.4 Mechanical, Electrical, and Plumbing Components 6.4.7 Electrical and Communications Equipment 6.4.7.1 Control Panels, Motor Control Centers, and Switchgear Provisions Building Code Provisions <\/td>\n<\/tr>\n | ||||||
454<\/td>\n | Retrofit Standard Provisions Typical Causes of Damage <\/td>\n<\/tr>\n | ||||||
455<\/td>\n | Damage Example <\/td>\n<\/tr>\n | ||||||
457<\/td>\n | Seismic Mitigation Considerations Mitigation Examples <\/td>\n<\/tr>\n | ||||||
459<\/td>\n | Mitigation Details <\/td>\n<\/tr>\n | ||||||
461<\/td>\n | 50_FEMAE-74-Chapter6_4_7_2 6.4 Mechanical, Electrical, and Plumbing Components 6.4.7 Electrical and Communications Equipment 6.4.7.2 Emergency Generators Provisions Building Code Provisions Rehabilitation Code Provisions <\/td>\n<\/tr>\n | ||||||
462<\/td>\n | Typical Causes of Damage Seismic Mitigation Considerations <\/td>\n<\/tr>\n | ||||||
463<\/td>\n | Mitigation Examples <\/td>\n<\/tr>\n | ||||||
465<\/td>\n | Mitigation Details <\/td>\n<\/tr>\n | ||||||
466<\/td>\n | 51_FEMAE-74-Chapter6_4_7_3 6.4 Mechanical, Electrical, and Plumbing Components 6.4.7 Electrical and Communications Equipment 6.4.7.3 Transformers Provisions Building Code Provisions <\/td>\n<\/tr>\n | ||||||
467<\/td>\n | Retrofit Standard Provisions Typical Causes of Damage <\/td>\n<\/tr>\n | ||||||
468<\/td>\n | Damage Examples <\/td>\n<\/tr>\n | ||||||
469<\/td>\n | Seismic Mitigation Considerations <\/td>\n<\/tr>\n | ||||||
474<\/td>\n | Mitigation Details <\/td>\n<\/tr>\n | ||||||
475<\/td>\n | 52_FEMAE-74-Chapter6_4_7_4 6.4 Mechanical, Electrical, and Plumbing Components 6.4.7 Electrical and Communications Equipment 6.4.7.4 Batteries and Battery Racks Provisions Building Code Provisions Retrofit Standard Provisions <\/td>\n<\/tr>\n | ||||||
476<\/td>\n | Typical Causes of Damage <\/td>\n<\/tr>\n | ||||||
477<\/td>\n | Damage Examples Seismic Mitigation Considerations <\/td>\n<\/tr>\n | ||||||
478<\/td>\n | Mitigation Examples <\/td>\n<\/tr>\n | ||||||
480<\/td>\n | Mitigation Details <\/td>\n<\/tr>\n | ||||||
481<\/td>\n | 53_FEMAE-74-Chapter6_4_7_5 6.4 Mechanical, Electrical, and Plumbing Components 6.4.7 Electrical And Communications Equipment 6.4.7.5 Photovoltaic (PV) Power Systems Provisions Building Code Provisions <\/td>\n<\/tr>\n | ||||||
482<\/td>\n | Retrofit Standard Provisions Typical Causes of Damage Seismic Mitigation Considerations <\/td>\n<\/tr>\n | ||||||
484<\/td>\n | Mitigation Examples <\/td>\n<\/tr>\n | ||||||
488<\/td>\n | Mitigation Details <\/td>\n<\/tr>\n | ||||||
490<\/td>\n | 54_FEMAE-74-Chapter6_4_7_6 6.4 Mechanical, Electrical, and Plumbing Components 6.4.7 Electrical and Communications Equipment 6.4.7.6 Communications Antennae Provisions Building Code Provisions Retrofit Standard Provisions <\/td>\n<\/tr>\n | ||||||
491<\/td>\n | Typical Causes of Damage <\/td>\n<\/tr>\n | ||||||
492<\/td>\n | Damage Examples <\/td>\n<\/tr>\n | ||||||
494<\/td>\n | Seismic Mitigation Considerations <\/td>\n<\/tr>\n | ||||||
495<\/td>\n | Mitigation Examples <\/td>\n<\/tr>\n | ||||||
497<\/td>\n | Mitigation Details <\/td>\n<\/tr>\n | ||||||
499<\/td>\n | 55_FEMAE-74-Chapter6_4_8_1 6.4 Mechanical, Electrical, and Plumbing Components 6.4.8 Electrical and Communications Distribution Equipment 6.4.8.1 Electrical Raceways, Conduit, and Cable Trays Provisions Building Code Provisions <\/td>\n<\/tr>\n | ||||||
500<\/td>\n | Retrofit Standard Provisions Typical Causes of Damage <\/td>\n<\/tr>\n | ||||||
501<\/td>\n | Damage Examples Seismic Mitigation Considerations <\/td>\n<\/tr>\n | ||||||
502<\/td>\n | Mitigation Examples <\/td>\n<\/tr>\n | ||||||
503<\/td>\n | Mitigation Details <\/td>\n<\/tr>\n | ||||||
504<\/td>\n | 56_FEMAE-74-Chapter6_4_8_2 6.4 Mechanical, Electrical, and Plumbing Components 6.4.8 Electrical and Communications Distribution Equipment 6.4.8.2 Electrical Distribution Panels Provisions Building Code Provisions Retrofit Standard Provisions <\/td>\n<\/tr>\n | ||||||
505<\/td>\n | Typical Causes of Damage <\/td>\n<\/tr>\n | ||||||
506<\/td>\n | Damage Examples Seismic Mitigation Considerations <\/td>\n<\/tr>\n | ||||||
507<\/td>\n | Mitigation Examples <\/td>\n<\/tr>\n | ||||||
508<\/td>\n | Mitigation Details <\/td>\n<\/tr>\n | ||||||
509<\/td>\n | 57_FEMAE-74-Chapter6_4_9_1 6.4 Mechanical, Electrical, and Plumbing Components 6.4.9 Light Fixtures 6.4.9.1 Recessed Light Fixtures Provisions Building Code Provisions <\/td>\n<\/tr>\n | ||||||
510<\/td>\n | Retrofit Standard Provisions <\/td>\n<\/tr>\n | ||||||
511<\/td>\n | Typical Causes of Damage <\/td>\n<\/tr>\n | ||||||
512<\/td>\n | Damage Examples <\/td>\n<\/tr>\n | ||||||
516<\/td>\n | Seismic Mitigation Considerations <\/td>\n<\/tr>\n | ||||||
517<\/td>\n | Mitigation Examples <\/td>\n<\/tr>\n | ||||||
518<\/td>\n | Mitigation Details <\/td>\n<\/tr>\n | ||||||
520<\/td>\n | 58_FEMAE-74-Chapter6_4_9_2 6.4 Mechanical, Electrical, and Plumbing Components 6.4.9 Light Fixtures 6.4.9.2 Surface-Mounted lighting Provisions Building Code Provisions <\/td>\n<\/tr>\n | ||||||
522<\/td>\n | Retrofit Standard Provisions Typical Causes of Damage <\/td>\n<\/tr>\n | ||||||
523<\/td>\n | Damage Examples <\/td>\n<\/tr>\n | ||||||
525<\/td>\n | Seismic Mitigation Considerations <\/td>\n<\/tr>\n | ||||||
526<\/td>\n | Mitigation Examples <\/td>\n<\/tr>\n | ||||||
527<\/td>\n | Mitigation Details <\/td>\n<\/tr>\n | ||||||
528<\/td>\n | 59_FEMAE-74-Chapter6_4_9_3 6.4 Mechanical, ElectricaL, and Plumbing Components 6.4.9 Light Fixtures 6.4.9.3 Pendant Light Fixtures Provisions Building Code Provisions Retrofit Standard Provisions <\/td>\n<\/tr>\n | ||||||
529<\/td>\n | Typical Causes of Damage Damage Examples <\/td>\n<\/tr>\n | ||||||
532<\/td>\n | Seismic Mitigation Considerations <\/td>\n<\/tr>\n | ||||||
533<\/td>\n | Mitigation Details <\/td>\n<\/tr>\n | ||||||
534<\/td>\n | 60_FEMAE-74-Chapter6_4_9_4 6.4 Mechanical, Electrical, and Plumbing Components 6.4.9 Light Fixtures 6.4.9.4 Heavy Light Fixtures Provisions Building Code Provisions Retrofit Standard Provisions <\/td>\n<\/tr>\n | ||||||
535<\/td>\n | Typical Causes of Damage Damage Examples <\/td>\n<\/tr>\n | ||||||
536<\/td>\n | Seismic Mitigation Considerations <\/td>\n<\/tr>\n | ||||||
537<\/td>\n | Mitigation Examples <\/td>\n<\/tr>\n | ||||||
539<\/td>\n | Mitigation Details <\/td>\n<\/tr>\n | ||||||
541<\/td>\n | 61-82.pdf 61_FEMAE-74-Chapter6_4_10_1 6.4 Mechanical, Electrical, and Plumbing Components 6.4.10 Elevators and Escalators 6.4.10.1 Hydraulic Elevators Provisions Building Code Provisions <\/td>\n<\/tr>\n | ||||||
542<\/td>\n | Retrofit Standard Provisions Typical Causes of Damage <\/td>\n<\/tr>\n | ||||||
543<\/td>\n | Seismic Mitigation Considerations <\/td>\n<\/tr>\n | ||||||
544<\/td>\n | Mitigation Details <\/td>\n<\/tr>\n | ||||||
546<\/td>\n | 62_FEMAE-74-Chapter6_4_10_2 <\/td>\n<\/tr>\n | ||||||
564<\/td>\n | 63_FEMAE-74-Chapter6_4_10_3 6.4 Mechanical, Electrical, and Plumbing Components 6.4.10 Elevators and Escalators 6.4.10.3 Escalators Provisions Building Code Provisions Retrofit Standard Provisions <\/td>\n<\/tr>\n | ||||||
565<\/td>\n | Typical Causes of Damage <\/td>\n<\/tr>\n | ||||||
566<\/td>\n | Damage Examples <\/td>\n<\/tr>\n | ||||||
567<\/td>\n | Seismic Mitigation Considerations <\/td>\n<\/tr>\n | ||||||
568<\/td>\n | Mitigation Details <\/td>\n<\/tr>\n | ||||||
569<\/td>\n | 64_FEMAE-74-Chapter6_4_11_1 6.4 Mechanical, Electrical, and Plumbing Components 6.4.11 Conveyors 6.4.11.1 Conveyors Provisions Building Code Provisions Retrofit Standard Provisions <\/td>\n<\/tr>\n | ||||||
570<\/td>\n | Typical Causes of Damage Damage Examples <\/td>\n<\/tr>\n | ||||||
573<\/td>\n | Seismic Mitigation Considerations <\/td>\n<\/tr>\n | ||||||
574<\/td>\n | Mitigation Details <\/td>\n<\/tr>\n | ||||||
575<\/td>\n | 65_FEMAE-74-Chapter6_5_1_1 6.5 Furniture, Fixtures, Equipment and Contents 6.5.1 Storage Racks 6.5.1.1 Light Duty SHelving Provisions Building Code Provisions Retrofit Standard Provisions Typical Causes of Damage <\/td>\n<\/tr>\n | ||||||
576<\/td>\n | Damage Examples <\/td>\n<\/tr>\n | ||||||
577<\/td>\n | Seismic Mitigation Considerations <\/td>\n<\/tr>\n | ||||||
578<\/td>\n | Mitigation Examples <\/td>\n<\/tr>\n | ||||||
583<\/td>\n | Mitigation Details <\/td>\n<\/tr>\n | ||||||
584<\/td>\n | 66_FEMAE-74-Chapter6_5_1_2 6.5 Furniture, Fixtures, Equipment and Contents 6.5.1 Storage Racks 6.5.1.2 Industrial Storage Racks Provisions Building Code Provisions Retrofit Standard Provisions <\/td>\n<\/tr>\n | ||||||
585<\/td>\n | Typical Causes of Damage <\/td>\n<\/tr>\n | ||||||
586<\/td>\n | Damage Examples <\/td>\n<\/tr>\n | ||||||
590<\/td>\n | Seismic Mitigation Considerations <\/td>\n<\/tr>\n | ||||||
591<\/td>\n | Mitigation Examples <\/td>\n<\/tr>\n | ||||||
593<\/td>\n | Mitigation Details <\/td>\n<\/tr>\n | ||||||
594<\/td>\n | 67_FEMAE-74-Chapter6_5_2_1 6.5 Furniture, Fixtures, Equipment and Contents 6.5.2 Bookcases, Shelving 6.5.2.1 Bookshelves Provisions Building Code Provisions Retrofit Standard Provisions Typical Causes of Damage <\/td>\n<\/tr>\n | ||||||
595<\/td>\n | Damage Examples <\/td>\n<\/tr>\n | ||||||
597<\/td>\n | Seismic Mitigation Considerations <\/td>\n<\/tr>\n | ||||||
599<\/td>\n | Mitigation Details <\/td>\n<\/tr>\n | ||||||
601<\/td>\n | 68_FEMAE-74-Chapter6_5_2_2 6.5 Furniture, Fixtures, Equipment and Contents 6.5.2 Bookcases, shelving 6.5.2.2 Library and Other Shelving Provisions Building Code Provisions Retrofit Standard Provisions Typical Causes of Damage <\/td>\n<\/tr>\n | ||||||
602<\/td>\n | Damage Examples <\/td>\n<\/tr>\n | ||||||
606<\/td>\n | Seismic Mitigation Considerations <\/td>\n<\/tr>\n | ||||||
607<\/td>\n | Mitigation Examples <\/td>\n<\/tr>\n | ||||||
608<\/td>\n | Mitigation Details <\/td>\n<\/tr>\n | ||||||
611<\/td>\n | 69_FEMAE-74-Chapter6_5_3_1 6.5 Furniture, Fixtures, Equipment and Contents 6.5.3 Computer and Communication Equipment 6.5.3.1 Computer Access Floors and Equipment Provisions Building Code Provisions Retrofit Standard Provisions Typical Causes of Damage <\/td>\n<\/tr>\n | ||||||
612<\/td>\n | Damage Examples <\/td>\n<\/tr>\n | ||||||
615<\/td>\n | Seismic Mitigation Considerations Mitigation Examples <\/td>\n<\/tr>\n | ||||||
619<\/td>\n | Mitigation Details <\/td>\n<\/tr>\n | ||||||
622<\/td>\n | 70_FEMAE-74-Chapter6_5_3_2 6.5 Furniture, Fixtures, Equipment and Contents 6.5.3 Computer and Communication Equipment 6.5.3.2 Computer and Communication Racks Provisions Building Code Provisions <\/td>\n<\/tr>\n | ||||||
623<\/td>\n | Retrofit Standard Provisions Typical Causes of Damage Damage Examples <\/td>\n<\/tr>\n | ||||||
624<\/td>\n | Seismic Mitigation Considerations <\/td>\n<\/tr>\n | ||||||
625<\/td>\n | Mitigation Examples <\/td>\n<\/tr>\n | ||||||
626<\/td>\n | Mitigation Details <\/td>\n<\/tr>\n | ||||||
628<\/td>\n | 71_FEMAE-74-Chapter6_5_3_3 6.5 Furniture, Fixtures, Equipment and Contents 6.5.3 Computer and Communication Equipment 6.5.3.3 Desktop Computers and Accessories Typical Causes of Damage Damage Examples <\/td>\n<\/tr>\n | ||||||
629<\/td>\n | Seismic Mitigation Considerations <\/td>\n<\/tr>\n | ||||||
630<\/td>\n | Mitigation Details <\/td>\n<\/tr>\n | ||||||
631<\/td>\n | 72_FEMAE-74-Chapter6_5_3_4 6.5 Furniture, Fixtures, Equipment and Contents 6.5.3 Computer and Communication Equipment 6.5.3.4 Televisions and Video Monitors, Wall-Mounted Provisions Building Code Provisions Retrofit Standard Provisions Typical Causes of Damage <\/td>\n<\/tr>\n | ||||||
632<\/td>\n | Existing Condition <\/td>\n<\/tr>\n | ||||||
633<\/td>\n | Seismic Mitigation Considerations <\/td>\n<\/tr>\n | ||||||
634<\/td>\n | Mitigation Examples <\/td>\n<\/tr>\n | ||||||
636<\/td>\n | Mitigation Details <\/td>\n<\/tr>\n | ||||||
637<\/td>\n | 73_FEMAE-74-Chapter6_5_4_1 6.5 Furniture, Fixtures, Equipment and Contents 6.5.4 Hazardous Materials Storage 6.5.4.1 Hazardous Materials Storage Provisions Building Code Provisions Retrofit Standard Provisions <\/td>\n<\/tr>\n | ||||||
638<\/td>\n | Typical Causes of Damage Damage Examples <\/td>\n<\/tr>\n | ||||||
641<\/td>\n | Seismic Mitigation Considerations <\/td>\n<\/tr>\n | ||||||
643<\/td>\n | 74_FEMAE-74-Chapter6_5_5_1 6.5 Furniture, Fixtures, Equipment and Contents 6.5.5 Miscellaneous Furniture, Fixtures and Equipment 6.5.5.1 File Cabinets Typical Causes of Damage <\/td>\n<\/tr>\n | ||||||
644<\/td>\n | Damage Examples <\/td>\n<\/tr>\n | ||||||
646<\/td>\n | Seismic Mitigation Considerations <\/td>\n<\/tr>\n | ||||||
647<\/td>\n | Mitigation Details <\/td>\n<\/tr>\n | ||||||
650<\/td>\n | 75-82.pdf 75_FEMAE-74-Chapter6_5_5_2 6.5 Furniture, Fixtures, Equipment and Contents 6.5.5 Miscellaneous Furniture, Fixtures and Equipment 6.5.5.2 Demountable Partitions Typical Causes of Damage Damage Examples <\/td>\n<\/tr>\n | ||||||
651<\/td>\n | Seismic Mitigation Considerations <\/td>\n<\/tr>\n | ||||||
652<\/td>\n | Mitigation Details <\/td>\n<\/tr>\n | ||||||
654<\/td>\n | 76_FEMAE-74-Chapter6_5_5_3 6.5 Furniture, Fixtures, Equipment and Contents 6.5.5 Miscellaneous Furniture, Fixtures and Equipment 6.5.5.3 Miscellaneous Furniture and Fixtures Typical Causes of Damage Damage Examples <\/td>\n<\/tr>\n | ||||||
656<\/td>\n | Seismic Mitigation Considerations <\/td>\n<\/tr>\n | ||||||
657<\/td>\n | Mitigation Examples <\/td>\n<\/tr>\n | ||||||
659<\/td>\n | 77_FEMAE-74-Chapter6_5_6_1 6.5 Furniture, Fixtures, Equipment and Contents 6.5.6 Miscellaneous Contents 6.5.6.1 Shelf-Mounted Items Typical Causes of Damage Damage Examples <\/td>\n<\/tr>\n | ||||||
660<\/td>\n | Seismic Mitigation Considerations <\/td>\n<\/tr>\n | ||||||
661<\/td>\n | Mitigation Examples <\/td>\n<\/tr>\n | ||||||
664<\/td>\n | Mitigation Details <\/td>\n<\/tr>\n | ||||||
665<\/td>\n | 78_FEMAE-74-Chapter6_5_6_2 6.5 Furniture, Fixtures, Equipment and Contents 6.5.6 Miscellaneous Contents 6.5.6.2 DeskTop, CounterTop Items Typical Causes of Damage Damage Examples <\/td>\n<\/tr>\n | ||||||
666<\/td>\n | Seismic Mitigation Considerations <\/td>\n<\/tr>\n | ||||||
667<\/td>\n | Mitigation Examples <\/td>\n<\/tr>\n | ||||||
668<\/td>\n | Mitigation Details <\/td>\n<\/tr>\n | ||||||
670<\/td>\n | 79_FEMAE-74-Chapter6_5_6_3 6.5 Furniture, Fixtures, Equipment and Contents 6.5.6 Miscellaneous Contents 6.5.6.3 Fragile Artwork Typical Causes of Damage Damage Examples <\/td>\n<\/tr>\n | ||||||
672<\/td>\n | Seismic Mitigation Considerations <\/td>\n<\/tr>\n | ||||||
673<\/td>\n | Mitigation Examples <\/td>\n<\/tr>\n | ||||||
676<\/td>\n | Mitigation Details <\/td>\n<\/tr>\n | ||||||
677<\/td>\n | 80_FEMAE-74-Chapter6_5_6_4 6.5 Furniture, Fixtures, Equipment and Contents 6.5.6 Miscellaneous Contents 6.5.6.4 Fire Extinguisher and Cabinet Typical Causes of Damage <\/td>\n<\/tr>\n | ||||||
678<\/td>\n | Damage Example <\/td>\n<\/tr>\n | ||||||
679<\/td>\n | Seismic Mitigation Considerations Mitigation Details <\/td>\n<\/tr>\n | ||||||
680<\/td>\n | 81_FEMAE-74-Chapter6_part2 6.6 Installation Notes, Safety Warnings, and additional guidelines 6.6.1 Positive Connections <\/td>\n<\/tr>\n | ||||||
681<\/td>\n | 6.6.2 Typical Wall Attachment Details Anchorage to Wood or Metal Stud Partition Walls <\/td>\n<\/tr>\n | ||||||
682<\/td>\n | Hardware \u2013 Recommended Hardware – Not Recommended <\/td>\n<\/tr>\n | ||||||
683<\/td>\n | Anchorage to Concrete or Masonry Walls <\/td>\n<\/tr>\n | ||||||
684<\/td>\n | Hardware and Procedures \u2013 Recommended <\/td>\n<\/tr>\n | ||||||
685<\/td>\n | Hardware and Procedures – Not Recommended 6.6.3 Typical Floor and Ceiling Attachment Details Anchorage to Wood Framing Hardware and Procedures – Recommended <\/td>\n<\/tr>\n | ||||||
686<\/td>\n | Hardware and Procedures – Not Recommended Anchorage to Steel Framing Hardware – Recommended Anchorage to Concrete Floor or Roof Slabs Hardware and Procedures – Recommended <\/td>\n<\/tr>\n | ||||||
687<\/td>\n | Hardware and Procedures – Not Recommended 6.6.4 Typical Shelf or Countertop Attachment Details Hardware and Procedures – Recommended <\/td>\n<\/tr>\n | ||||||
688<\/td>\n | 6.6.5 Purchasing 6.6.6 Patching, Painting, and Corrosion Protection <\/td>\n<\/tr>\n | ||||||
689<\/td>\n | 6.6.7 Safety Precautions Procedures – Recommended 6.6.8 Electrical Danger Warnings and guidelines <\/td>\n<\/tr>\n | ||||||
691<\/td>\n | 82_FEMAE-74-Chapter7 <\/td>\n<\/tr>\n | ||||||
692<\/td>\n | 83_FEMAE-74-AppendixA <\/td>\n<\/tr>\n | ||||||
694<\/td>\n | 84_FEMAE-74-AppendixB <\/td>\n<\/tr>\n | ||||||
696<\/td>\n | 85_FEMAE-74-AppendixC <\/td>\n<\/tr>\n | ||||||
698<\/td>\n | 86_FEMAE-74-AppendixD <\/td>\n<\/tr>\n | ||||||
726<\/td>\n | 87_FEMAE-74-AppendixE.pdf <\/td>\n<\/tr>\n | ||||||
739<\/td>\n | 83_FEMAE-74-AppendixA <\/td>\n<\/tr>\n | ||||||
757<\/td>\n | 84_FEMAE-74-AppendixB <\/td>\n<\/tr>\n | ||||||
759<\/td>\n | 85_FEMAE-74-AppendixC <\/td>\n<\/tr>\n | ||||||
761<\/td>\n | 86_FEMAE-74-AppendixD <\/td>\n<\/tr>\n | ||||||
789<\/td>\n | 87_FEMAE-74-AppendixE <\/td>\n<\/tr>\n | ||||||
802<\/td>\n | 88_FEMAE-74-AppendixF <\/td>\n<\/tr>\n | ||||||
803<\/td>\n | FEMAE-74_AppendixF_SuspendedAcousticalTileCeiling <\/td>\n<\/tr>\n | ||||||
810<\/td>\n | FEMAE-74_AppendixF_MetalStudPartition <\/td>\n<\/tr>\n | ||||||
819<\/td>\n | 89_FEMAE-74-AppendixG <\/td>\n<\/tr>\n | ||||||
865<\/td>\n | 90_FEMAE-74-AppendixH <\/td>\n<\/tr>\n | ||||||
874<\/td>\n | 91_FEMAE-74-AppendixI <\/td>\n<\/tr>\n | ||||||
882<\/td>\n | FEMA Project Officers Project Managers <\/td>\n<\/tr>\n | ||||||
883<\/td>\n | Project Management Committee <\/td>\n<\/tr>\n | ||||||
884<\/td>\n | Project Review Panel <\/td>\n<\/tr>\n | ||||||
885<\/td>\n | Additional Reviewers Additional Contributor <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" FEMA E-74, Reducing the Risks of Nonstructural Earthquake Damage\u2014A Practical Guide, Fourth Edition<\/b><\/p>\n |