{"id":235979,"date":"2024-10-19T15:23:57","date_gmt":"2024-10-19T15:23:57","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-en-60603-7-22009-2010\/"},"modified":"2024-10-25T10:00:12","modified_gmt":"2024-10-25T10:00:12","slug":"bs-en-60603-7-22009-2010","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-en-60603-7-22009-2010\/","title":{"rendered":"BS EN 60603-7-2:2009 2010"},"content":{"rendered":"
This part of IEC 60603-7 covers 8-way, unshielded, free and fixed connectors, and specifies mechanical and environmental requirements, and electrical transmission requirements for frequencies up to 100 MHz. These connectors are typically used as category 5 connectors in class D cabling systems specified in ISO\/IEC 11801:2002.<\/p>\n
These connectors are intermateable, interoperable, and backward compatible with other IEC 60603-7 series connectors. While the definition of interoperable is being discussed within IEC, \u201cinteroperable\u201d in this standard means the following: The fixed and the free connector are capable of interconnecting with any IEC 60603-7 series connector, and that when it is interconnected, it fully meets all requirements of the lower frequency IEC 60603-7 series standard.<\/p>\n
\nNOTE Transmission performance categories: in this part of IEC 60603-7, the term \u201ccategory\u201d, when used in reference to transmission performance, refers to those categories defined by ISO\/IEC 11801:2002.<\/p>\n<\/blockquote>\n
PDF Catalog<\/h4>\n
\n
\n PDF Pages<\/th>\n PDF Title<\/th>\n<\/tr>\n \n 7<\/td>\n CONTENTS <\/td>\n<\/tr>\n \n 10<\/td>\n FOREWORD <\/td>\n<\/tr>\n \n 12<\/td>\n INTRODUCTION <\/td>\n<\/tr>\n \n 13<\/td>\n 1 General
1.1 Scope
1.2 Normative references <\/td>\n<\/tr>\n\n 15<\/td>\n 2 IEC type designation <\/td>\n<\/tr>\n \n 16<\/td>\n 2.1 Terms and definitions <\/td>\n<\/tr>\n \n 17<\/td>\n 3 Common features and isometric view
3.1 Isometric view
3.2 Mating information
Figure 1 \u2013 Isometric view <\/td>\n<\/tr>\n\n 18<\/td>\n Figure 2 \u2013 Contact interface dimensions with terminated free connector <\/td>\n<\/tr>\n \n 19<\/td>\n Table 1 \u2013 Dimensions for Figure 2 <\/td>\n<\/tr>\n \n 21<\/td>\n Figure 3 \u2013 Fixed connector details <\/td>\n<\/tr>\n \n 22<\/td>\n Table 2 \u2013 Dimensions for Figure 3 <\/td>\n<\/tr>\n \n 23<\/td>\n Figure 4 \u2013 Free connector view <\/td>\n<\/tr>\n \n 24<\/td>\n Table 3 \u2013 Dimensions for Figure 4 <\/td>\n<\/tr>\n \n 25<\/td>\n 4 Cable terminations and internal connections \u2013 fixed and free connectors
4.1 General
4.2 Termination types <\/td>\n<\/tr>\n\n 26<\/td>\n 5 Gauges
5.1 Fixed connectors
Figure 5 \u2013 \u201cGo\u201d gauge <\/td>\n<\/tr>\n\n 27<\/td>\n Figure 6 \u2013 “No-go” gauges <\/td>\n<\/tr>\n \n 28<\/td>\n Table 4 \u2013 Dimensions for Figures 5 and 6 <\/td>\n<\/tr>\n \n 29<\/td>\n 5.2 Free connectors
Figure 7 \u2013 \u201c No-go\u201d gauges
Table 5 \u2013 Dimensions for Figure 7 <\/td>\n<\/tr>\n\n 30<\/td>\n Figure 8 \u2013 \u201cGo\u201d gauge
Table 6 \u2013 Dimensions for Figure 8 <\/td>\n<\/tr>\n\n 31<\/td>\n 6 Characteristics
6.1 General
6.2 Pin and pair grouping assignment.
6.3 Classification into climatic category
Figure 9 \u2013 Fixed connector pin and pair grouping assignment (front view of connector)
Table 7 \u2013 Climatic categories \u2013 selected values <\/td>\n<\/tr>\n\n 32<\/td>\n 6.4 Electrical characteristics
Table 8 \u2013 Creepage and clearance distances <\/td>\n<\/tr>\n\n 33<\/td>\n Figure 10 \u2013 Connector de-rating curve <\/td>\n<\/tr>\n \n 35<\/td>\n 6.6 Mechanical
7 Tests and test schedule
7.1 General <\/td>\n<\/tr>\n\n 36<\/td>\n 7.2 Arrangement for contact resistance test:
Figure 11 \u2013 Arrangement for contact resistance test <\/td>\n<\/tr>\n\n 37<\/td>\n 7.3 Arrangement for vibration test (test phase CP1)
7.4 Test procedures and measuring methods
7.5 Preconditioning
Figure 12 \u2013 Arrangement for vibration test <\/td>\n<\/tr>\n\n 38<\/td>\n 7.6 Wiring and mounting of specimens
7.7 Test schedules <\/td>\n<\/tr>\n\n 39<\/td>\n Table 9 \u2013 Test group P <\/td>\n<\/tr>\n \n 40<\/td>\n Table 10 \u2013 Test group AP <\/td>\n<\/tr>\n \n 42<\/td>\n Table 11 \u2013 Test group BP <\/td>\n<\/tr>\n \n 43<\/td>\n Table 12 \u2013 Test group CP <\/td>\n<\/tr>\n \n 44<\/td>\n Table 13 \u2013 Test group DP <\/td>\n<\/tr>\n \n 45<\/td>\n Table 14 \u2013 Test group EP <\/td>\n<\/tr>\n \n 46<\/td>\n Table 15 \u2013 Test group FP
Table 16 \u2013 Test group GP <\/td>\n<\/tr>\n\n 47<\/td>\n Annex A (normative) Gauging continuity procedure <\/td>\n<\/tr>\n \n 48<\/td>\n Table A.1 \u2013 Dimensions for Figure A.1 <\/td>\n<\/tr>\n \n 49<\/td>\n Figure A.1 \u2013 Gauge <\/td>\n<\/tr>\n \n 50<\/td>\n Figure A.2 \u2013 Gauge insertion <\/td>\n<\/tr>\n \n 51<\/td>\n Annex B (normative) Locking-device mechanical operation <\/td>\n<\/tr>\n \n 52<\/td>\n Annex C (normative) Test plug requirements <\/td>\n<\/tr>\n \n 53<\/td>\n Figure C.1 \u2013 De-embedding reference plug <\/td>\n<\/tr>\n \n 55<\/td>\n Figure C.2 \u2013 De-embedding reference jack <\/td>\n<\/tr>\n \n 57<\/td>\n Table C.1 \u2013 De-embedded real and imaginary reference jack vectors <\/td>\n<\/tr>\n \n 58<\/td>\n Table C.2 \u2013 Test plug NEXT loss limits <\/td>\n<\/tr>\n \n 59<\/td>\n Table C.3 \u2013 Test plug NEXT loss ranges <\/td>\n<\/tr>\n \n 60<\/td>\n Table C.4 \u2013 Coaxial termination reference head component list <\/td>\n<\/tr>\n \n 61<\/td>\n Figure C.3 \u2013 THI3KIT test head interface with baluns attached <\/td>\n<\/tr>\n \n 62<\/td>\n Table C.5 \u2013 Coaxial termination reference head, additional parts <\/td>\n<\/tr>\n \n 63<\/td>\n Figure C.4 \u2013 Alternative to item 3.1 in Table C.5
Figure C.5 \u2013 Back-to-back through calibration <\/td>\n<\/tr>\n\n 65<\/td>\n Figure C.6 \u2013 Mated test plug\/coaxial termination reference test head test configuration
Table C.6 \u2013 Return loss requirements for return loss reference plug <\/td>\n<\/tr>\n\n 66<\/td>\n Annex D (normative) General requirements for the measurement set-up <\/td>\n<\/tr>\n \n 67<\/td>\n Figure D.1 \u2013 180\u00b0 hybrid used as a balun <\/td>\n<\/tr>\n \n 68<\/td>\n Figure D.2 \u2013 Calibration of reference loads
Table D.1 \u2013 Test balun performance characteristics <\/td>\n<\/tr>\n\n 69<\/td>\n Figure D.3 \u2013 Resistor load <\/td>\n<\/tr>\n \n 70<\/td>\n Figure D.4 \u2013 Screened pyramid <\/td>\n<\/tr>\n \n 71<\/td>\n Figure D.5 \u2013 Definition of reference planes <\/td>\n<\/tr>\n \n 72<\/td>\n Annex E (normative) Insertion loss
Figure E.1 \u2013 Calibration <\/td>\n<\/tr>\n\n 73<\/td>\n Figure E.2 \u2013 Measuring Set-up <\/td>\n<\/tr>\n \n 74<\/td>\n Annex F (normative) Return loss <\/td>\n<\/tr>\n \n 75<\/td>\n Table F.1 \u2013 Uncertainty band of return loss measurement at frequencies below 100 MHz
Table F.2 \u2013 Uncertainty band of return loss measurement at frequencies above 100 MHz <\/td>\n<\/tr>\n\n 76<\/td>\n Annex G (normative) Near end cross talk (NEXT)
Figure G.1 \u2013 NEXT measurement for differential and common mode terminations <\/td>\n<\/tr>\n\n 78<\/td>\n Annex H (normative) Far end cross talk
Figure H.1 \u2013 FEXT measurement differential and common mode terminations <\/td>\n<\/tr>\n\n 80<\/td>\n Annex I (normative) Termination of balun
Figure I.1 \u2013 Balanced attenuator for balun centre tap grounded
Figure I.2 \u2013 Balanced attenuator for balun centre tap open <\/td>\n<\/tr>\n\n 81<\/td>\n Annex J (normative) Gauge requirements <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" Connectors for electronic equipment – Detail specification for 8-way, unshielded, free and fixed connectors, for data transmissions with frequencies up to 100 MHz<\/b><\/p>\n
\n\n
\n Published By<\/td>\n Publication Date<\/td>\n Number of Pages<\/td>\n<\/tr>\n \n BSI<\/b><\/a><\/td>\n 2010<\/td>\n 84<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":235984,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[587,2641],"product_tag":[],"class_list":{"0":"post-235979","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-31-220-10","7":"product_cat-bsi","9":"first","10":"instock","11":"sold-individually","12":"shipping-taxable","13":"purchasable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/235979","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/235984"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=235979"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=235979"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=235979"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}