{"id":244308,"date":"2024-10-19T16:02:55","date_gmt":"2024-10-19T16:02:55","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-en-61158-4-222014\/"},"modified":"2024-10-25T11:01:51","modified_gmt":"2024-10-25T11:01:51","slug":"bs-en-61158-4-222014","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-en-61158-4-222014\/","title":{"rendered":"BS EN 61158-4-22:2014"},"content":{"rendered":"

IEC 61158-4-22:2014 specifies procedures for the timely transfer of data and control information from one data-link user entity to a peer user entity, and among the data-link entities forming the distributed data-link service provider and the structure of the fieldbus DLPDUs used for the transfer of data and control information by the protocol of this standard, and their representation as physical interface data units. This second edition cancels and replaces the first edition published in 2010 and constitutes a technical revision. The main changes are: – Introduction of new topology scan PDUs; – Bug fix of missing version field in some PDUs; – Introduction of new Physical Link descriptors.<\/p>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
6<\/td>\nEnglish
CONTENTS <\/td>\n<\/tr>\n
9<\/td>\nINTRODUCTION <\/td>\n<\/tr>\n
11<\/td>\n1 Scope
1.1 General
1.2 Specifications
1.3 Procedures
1.4 Applicability <\/td>\n<\/tr>\n
12<\/td>\n1.5 Conformance
2 Normative references
3 Terms, definitions, symbols, abbreviations and conventions <\/td>\n<\/tr>\n
13<\/td>\n3.1 Reference model terms and definitions <\/td>\n<\/tr>\n
14<\/td>\n3.2 Service convention terms and definitions <\/td>\n<\/tr>\n
15<\/td>\n3.3 Common terms and definitions <\/td>\n<\/tr>\n
16<\/td>\n3.4 Additional Type 22 definitions <\/td>\n<\/tr>\n
19<\/td>\n3.5 Common symbols and abbreviations <\/td>\n<\/tr>\n
20<\/td>\n3.6 Additional Type 22 symbols and abbreviations <\/td>\n<\/tr>\n
22<\/td>\n3.7 Conventions
Tables
Table 1 \u2013 DLPDU element definition <\/td>\n<\/tr>\n
23<\/td>\n4 Overview of the DL-protocol
4.1 Operating principle
4.2 Communication model
Table 2\u00a0\u2013\u00a0Conventions for protocol machine description <\/td>\n<\/tr>\n
24<\/td>\n4.3 Topology
4.4 DLPDU processing <\/td>\n<\/tr>\n
25<\/td>\n4.5 General communication mechanisms <\/td>\n<\/tr>\n
26<\/td>\n4.6 Gateway
4.7 Interaction models
5 DLPDU structure
5.1 Overview <\/td>\n<\/tr>\n
27<\/td>\n5.2 Data types and encoding rules
Table 3\u00a0\u2013\u00a0Transfer syntax for bit sequences <\/td>\n<\/tr>\n
28<\/td>\n5.3 DLPDU identification
Table 4\u00a0\u2013\u00a0Transfer syntax for data type Unsignedn
Table 5\u00a0\u2013\u00a0Transfer syntax for data type Signedn <\/td>\n<\/tr>\n
29<\/td>\n5.4 General DLPDU structure
Table 6\u00a0\u2013\u00a0Type 22 DLPDU inside an ISO\/IEC 88023
Table 7\u00a0\u2013\u00a0Type 22 DLPDU inside a VLAN tagged ISO\/IEC 88023 DLPDU <\/td>\n<\/tr>\n
30<\/td>\nTable 8\u00a0\u2013\u00a0Type 22 DLPDU inside an UDP DLPDU
Table 9\u00a0\u2013\u00a0General structure of a Type 22 DLPDU <\/td>\n<\/tr>\n
31<\/td>\n5.5 Communication management DLPDUs
Table 10\u00a0\u2013\u00a0DLPDU header structure
Table 11\u00a0\u2013\u00a0Network verification prepare DLPDU
Table 12\u00a0\u2013\u00a0Network verification environment DLPDU
Table 13\u00a0\u2013\u00a0Network verification information DLPDU <\/td>\n<\/tr>\n
32<\/td>\nTable 14\u00a0\u2013\u00a0Network verification acknowledgement DLPDU
Table 15\u00a0\u2013\u00a0RTFN scan network request DLPDU
Table 16\u00a0\u2013\u00a0RTFN scan network response DLPDU
Table 17\u00a0\u2013\u00a0Identification data <\/td>\n<\/tr>\n
33<\/td>\nTable 18\u00a0\u2013\u00a0Identification data v2 <\/td>\n<\/tr>\n
34<\/td>\nTable 19\u00a0\u2013\u00a0PhyLinkPortX <\/td>\n<\/tr>\n
35<\/td>\nTable 20\u00a0\u2013\u00a0RTF support
Table 21 \u2013\u00a0RTF2 support <\/td>\n<\/tr>\n
36<\/td>\nTable 22\u00a0\u2013\u00a0UseDHCP
Table 23\u00a0\u2013\u00a0DeviceRole <\/td>\n<\/tr>\n
37<\/td>\nTable 24\u00a0\u2013\u00a0RTFN connection management DLPDU
Table 25\u00a0\u2013\u00a0CDCN connection still alive DLPDU
Table 26\u00a0\u2013\u00a0ID data
Table 27\u00a0\u2013\u00a0RTFL control DLPDU <\/td>\n<\/tr>\n
38<\/td>\nTable 28\u00a0\u2013\u00a0RTFL configuration DLPDU
Table 29\u00a0\u2013\u00a0RTFL configuration acknowledgement DLPDU <\/td>\n<\/tr>\n
39<\/td>\n5.6 Cyclic data channel (CDC) DLPDUs
Table 30\u00a0\u2013\u00a0RTFL configuration 2 DLPDU
Table 31\u00a0\u2013\u00a0RTFL configuration acknowledgement 2 DLPDU
Table 32\u00a0\u2013\u00a0CDCL DLPDU <\/td>\n<\/tr>\n
40<\/td>\n5.7 Cyclic data channel (CDC) DLPDU data
5.8 Message channel (MSC) DLPDUs
Table 33\u00a0\u2013\u00a0CDCN DLPDU
Table 34\u00a0\u2013\u00a0CDC DLPDU data arrangement
Table 35\u00a0\u2013\u00a0CDC DLPDU data <\/td>\n<\/tr>\n
41<\/td>\nTable 36\u00a0\u2013\u00a0MSCL DLPDU
Table 37\u00a0\u2013\u00a0MSCL control <\/td>\n<\/tr>\n
42<\/td>\n5.9 Message channel DLPDU data – MSC message transfer protocol (MSC-MTP)
Table 38\u00a0\u2013\u00a0MSCN DLPDU
Table 39\u00a0\u2013\u00a0MSC-MTP frame structure <\/td>\n<\/tr>\n
43<\/td>\nTable 40\u00a0\u2013\u00a0Address type
Table 41\u00a0\u2013\u00a0MSC-MTP Init structure <\/td>\n<\/tr>\n
44<\/td>\nTable\u00a042\u00a0\u2013\u00a0MSC-MTP Init_Fast structure
Table 43\u00a0\u2013\u00a0MSC-MTP Send structure
Table 44\u00a0\u2013\u00a0MSC-MTP Acknowledgement structure <\/td>\n<\/tr>\n
45<\/td>\n5.10 Time synchronization
Table 45\u00a0\u2013\u00a0MSC-MTP Abort structure
Table 46\u00a0\u2013\u00a0Data structure of a message
Table 47\u00a0\u2013\u00a0DelayMeasurement start encoding <\/td>\n<\/tr>\n
46<\/td>\nTable 48\u00a0\u2013\u00a0DelayMeasurement read encoding
Table 49\u00a0\u2013\u00a0PCS configuration encoding
Table 50\u00a0\u2013\u00a0Time synchronization service request
Table 51\u00a0\u2013\u00a0Time synchronization service response <\/td>\n<\/tr>\n
47<\/td>\n6 Telegram timing and DLPDU handling
6.1 Communication mechanism <\/td>\n<\/tr>\n
48<\/td>\nFigures
Figure 1\u00a0\u2013\u00a0DLPDU sequence
Figure 2\u00a0\u2013\u00a0Communication relationship RTFN device <\/td>\n<\/tr>\n
49<\/td>\n6.2 Device synchronization
7 Type 22 protocol machines
7.1 RTFL device protocol machines <\/td>\n<\/tr>\n
50<\/td>\nFigure 3\u00a0\u2013\u00a0Overview RTFL device protocol machines <\/td>\n<\/tr>\n
51<\/td>\nFigure 4\u00a0\u2013\u00a0Protocol machine send DLPDU procedure
Figure 5\u00a0\u2013\u00a0Protocol machine receive DLPDU procedure <\/td>\n<\/tr>\n
52<\/td>\nFigure 6\u00a0\u2013\u00a0CDCL send cyclic data sequence <\/td>\n<\/tr>\n
53<\/td>\nFigure 7\u00a0\u2013\u00a0CDCL receive cyclic data sequence <\/td>\n<\/tr>\n
54<\/td>\nFigure 8\u00a0\u2013\u00a0MSCL send sequence <\/td>\n<\/tr>\n
55<\/td>\nFigure 9\u00a0\u2013\u00a0MSCL receive sequence <\/td>\n<\/tr>\n
56<\/td>\nFigure 10\u00a0\u2013\u00a0Network management protocol machine <\/td>\n<\/tr>\n
57<\/td>\nFigure 11\u00a0\u2013\u00a0Net management sequence at system boot up <\/td>\n<\/tr>\n
58<\/td>\nFigure 12\u00a0\u2013\u00a0Initialization sequence ordinary device <\/td>\n<\/tr>\n
59<\/td>\nFigure 13\u00a0\u2013\u00a0PCS configuration sequence <\/td>\n<\/tr>\n
60<\/td>\nFigure 14\u00a0\u2013\u00a0Delay measurement principle <\/td>\n<\/tr>\n
61<\/td>\n7.2 RTFN device protocol machines
Figure 15\u00a0\u2013\u00a0Overview RTFN device protocol machines <\/td>\n<\/tr>\n
62<\/td>\nFigure 16\u00a0\u2013\u00a0CDCN connection setup and release <\/td>\n<\/tr>\n
63<\/td>\n7.3 Message channel \u2013 Message transfer protocol (MSC-MTP)
Figure 17\u00a0\u2013\u00a0CDCN unpulish data <\/td>\n<\/tr>\n
64<\/td>\nFigure 18\u00a0\u2013\u00a0Segmentation sequence
Figure 19\u00a0\u2013\u00a0Expedited transfer sequence <\/td>\n<\/tr>\n
65<\/td>\nFigure 20\u00a0\u2013\u00a0Toggling from expedited transfer to segmented transfer <\/td>\n<\/tr>\n
66<\/td>\nFigure 21 \u2013 Segmentation sequence for broad- or multicast message without Acknowledgement <\/td>\n<\/tr>\n
67<\/td>\nBibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

Industrial communication networks. Fieldbus specifications – Data-link layer protocol specification. Type 22 elements<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
BSI<\/b><\/a><\/td>\n2014<\/td>\n70<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":244311,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[385,2641],"product_tag":[],"class_list":{"0":"post-244308","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-25-040-40","7":"product_cat-bsi","9":"first","10":"instock","11":"sold-individually","12":"shipping-taxable","13":"purchasable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/244308","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/244311"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=244308"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=244308"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=244308"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}