{"id":254805,"date":"2024-10-19T16:50:21","date_gmt":"2024-10-19T16:50:21","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-en-61558-2-122011\/"},"modified":"2024-10-25T12:16:18","modified_gmt":"2024-10-25T12:16:18","slug":"bs-en-61558-2-122011","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-en-61558-2-122011\/","title":{"rendered":"BS EN 61558-2-12:2011"},"content":{"rendered":"
Replacement:<\/i><\/p>\n
This part of IEC 61558 deals with the safety of constant voltage transformers<\/b> for general applications and power supply units<\/b> for constant voltage<\/b> for general applications. Constant voltage transformers<\/b> incorporating electronic circuits<\/b> are also covered by this standard.<\/p>\n NOTE 1 Safety includes electrical, thermal and mechanical aspects.<\/p>\n<\/blockquote>\n Unless otherwise specified, from here onward, the term transformer<\/b> covers constant voltage transformers<\/b> for general applications and power supply units for constant voltage<\/b> for general applications.<\/p>\n This part is applicable to stationary<\/b> or portable<\/b>, single-phase or polyphase, air-cooled (natural or forced), independent<\/b> or associated dry-type<\/b>:<\/p>\n \u2013 constant voltage auto-transformers;<\/b><\/p>\n<\/li>\n \u2013 constant voltage separating transformers;<\/b><\/p>\n<\/li>\n \u2013 constant voltage isolating transformers;<\/b><\/p>\n<\/li>\n \u2013 constant voltage safety isolating transformers.<\/b><\/p>\n<\/li>\n<\/ul>\n The windings may be encapsulated or non-encapsulated.<\/p>\n This standard is applicable to transformers<\/b> and power supply<\/b> (linear) with internal operating frequencies not exceeding 500 Hz.<\/p>\n This standard used in combination with Part 2-16 for switch mode power supply<\/b> (SMPS) units is also applicable to power supplies with internal operating frequencies higher than 500 Hz. Where the two requirements are in conflict, the most severe take precedence.<\/p>\n The rated supply voltage<\/b> does not exceed 1 000 V a.c., the rated supply frequency<\/b> does not exceed 500 Hz, the internal operating resonant frequency<\/b> does not exceed 30 kHz and the internal operating frequency<\/b> does not exceed 100 MHz.<\/p>\n The rated output<\/b> does not exceed:<\/p>\n \u2013 40 kVA for single-phase constant voltage auto-transformers<\/b>;<\/p>\n<\/li>\n \u2013 200 kVA for poly-phase constant voltage auto-transformers<\/b>;<\/p>\n<\/li>\n \u2013 25 kVA for single-phase constant voltage separating transformers<\/b> and constant voltage isolating transformers<\/b>;<\/p>\n<\/li>\n \u2013 40 kVA for poly-phase constant voltage separating transformers<\/b> and constant voltage isolating transformers<\/b>;<\/p>\n<\/li>\n \u2013 10 kVA for single-phase constant voltage safety isolating transformers<\/b>;<\/p>\n<\/li>\n \u2013 16 kVA for poly-phase constant voltage safety isolating transformers<\/b>.<\/p>\n<\/li>\n<\/ul>\n This part is applicable to transformers<\/b> without limitation of the rated output<\/b> subject to an agreement between the purchaser and the manufacturer.<\/p>\n NOTE 2 Transformers intended to supply distribution networks are not included in the scope.<\/p>\n<\/blockquote>\n Where applicable to constant voltage auto-transformers<\/p>\n \u2013 the no-load output voltage<\/b> or the rated output voltage<\/b> does not exceed 1 000 V a.c. or 1 415 V ripple-free d.c., and for independent constant voltage auto-transformers,<\/b> the no-load output voltage<\/b> and the rated output voltage<\/b> exceed 50 V a.c. or 120 V ripple-free d.c.;<\/p>\n<\/li>\n \u2013 constant voltage auto-transformers<\/b> covered by this part are used only in applications where no insulation<\/b> between circuits is required by the installation rules or by the end product standard.<\/p>\n<\/li>\n<\/ul>\n Where applicable to constant voltage separating transformers<\/b><\/p>\n \u2013 the no-load output voltage<\/b> or the rated output voltage<\/b> does not exceed 1 000 V a.c. or 1 415 V ripple-free d.c., and for independent constant voltage separating transformers,<\/b> the no-load output voltage<\/b> and the rated output voltage<\/b> exceed 50V a.c. or 120 V ripple-free d.c.;<\/p>\n<\/li>\n \u2013 constant voltage separating transformers<\/b> covered by this part are used only in applications where double<\/b> or reinforced insulation<\/b> between circuits is not required by the installation rules or by the end product standard.<\/p>\n<\/li>\n<\/ul>\n Where applicable to constant voltage isolating transformers<\/b><\/p>\n \u2013 the no-load output voltage<\/b> or the rated output voltage<\/b> does exceed 50 V a.c. or 120 V ripple-free d.c. and where applicable, does not exceed 500 V a.c. or 708 V ripple-free d.c. The no-load output voltage<\/b> and the rated output voltage<\/b> may be up to 1 000 V a.c. or 1 415 V ripple-free d.c. for special applications;<\/p>\n<\/li>\n \u2013 constant voltage isolating transformers<\/b> covered by this part are used only in applications where double<\/b> or reinforced insulation<\/b> between circuits is required by the installation rules or by the end product standard.<\/p>\n<\/li>\n<\/ul>\n Where applicable to constant voltage safety isolating transformers<\/b><\/p>\n \u2013 the no-load output voltage<\/b> or the rated output voltage<\/b> does not exceed 50 V a.c. or 120 V ripple-free d.c.;<\/p>\n<\/li>\n \u2013 constant voltage safety isolating transformers<\/b> covered by this part are used only in applications where double<\/b> or reinforced insulation<\/b> between circuits is required by the installation rules or by the end product standard.<\/p>\n<\/li>\n<\/ul>\n This part is not applicable to external circuits and their components intended to be connected to the input terminals and output terminals of the transformers<\/b>.<\/p>\n NOTE 3 Attention is drawn to the following:<\/p>\n<\/blockquote>\n \u2013 for transformers<\/b> intended to be used in vehicles, on board ships, and aircraft, additional requirements (from other applicable standards, national rules, etc.) may be necessary;<\/p>\n<\/li>\n \u2013 measures to protect the enclosure<\/b> and the components inside the enclosure<\/b> against external influences such as fungus, vermin, termites, solar-radiation, and icing should also be considered;<\/p>\n<\/li>\n \u2013 the different conditions for transportation, storage, and operation of the transformers<\/b> should also be considered;<\/p>\n<\/li>\n \u2013 additional requirements in accordance with other appropriate standards and national rules may be applicable to transformers<\/b> intended for use in special environments.<\/p>\n<\/li>\n<\/ul>\n NOTE 4 Future technological development of transformers<\/b> may necessitate a need to increase the upper limit of the frequencies, until then this part may be used as a guidance document.<\/p>\n<\/blockquote>\n Safety of transformers, reactors, power supply units and combinations thereof – Particular requirements and tests for constant voltage transformers and power supply units for constant voltage<\/b><\/p>\n\n
\n
\n
\n
\n
\n
\n
\n
\n
\n
\n
PDF Catalog<\/h4>\n
\n
\n PDF Pages<\/th>\n PDF Title<\/th>\n<\/tr>\n \n 5<\/td>\n English
\n
CONTENTS <\/td>\n<\/tr>\n\n 6<\/td>\n 1 Scope <\/td>\n<\/tr>\n \n 8<\/td>\n 2 Normative references
3 Terms and definitions
4 General requirements
5 General notes on tests
6 Ratings <\/td>\n<\/tr>\n\n 9<\/td>\n 7 Classification
8 Marking and other information <\/td>\n<\/tr>\n\n 10<\/td>\n 9 Protection against electric shock
10 Change of input voltage setting
11 Output voltage and output current under load <\/td>\n<\/tr>\n\n 11<\/td>\n 12 No-load output voltage <\/td>\n<\/tr>\n \n 12<\/td>\n 13 Short-circuit voltage
14 Heating
15 Short-circuit and overload protection <\/td>\n<\/tr>\n\n 13<\/td>\n 16 Mechanical strength
17 Protection against harmful ingress of dust, solid objects and moisture
18 Insulation resistance, dielectric strength and leakage current <\/td>\n<\/tr>\n\n 14<\/td>\n 19 Construction
Table 101 \u2013 Dielectric strength test voltages for constant voltage auto-transformers <\/td>\n<\/tr>\n\n 18<\/td>\n 20 Components
21 Internal wiring
22 Supply connection and other external flexible cables or cords
23 Terminals for external conductors
24 Provision for protective earthing
25 Screws and connections
26 Creepage distances, clearances and distances through insulation <\/td>\n<\/tr>\n\n 19<\/td>\n 27 Resistance to heat, fire and tracking
28 Resistance to rusting <\/td>\n<\/tr>\n\n 20<\/td>\n Annexes
Annex C
\n(normative) Creepage distances (cr), clearances (cl) and distances through insulation (dti) \u2013 Material group II (400 \u2264 CTI (600)
Annex\u00a0D (normative)
\nCreepage distances (cr), clearances (cl) and distances through insulation (dti) \u2013 Material group I (CTI \u2265 600)
Annex L (normative)
\nRoutine tests (production tests)
Annex R (normative)
\nExplanations of the application of 4.1.1.2.1 of IEC 60664-1 (see 26.2) <\/td>\n<\/tr>\n\n 21<\/td>\n Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" \n\n
\n Published By<\/td>\n Publication Date<\/td>\n Number of Pages<\/td>\n<\/tr>\n \n BSI<\/b><\/a><\/td>\n 2011<\/td>\n 24<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":254809,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[2641],"product_tag":[],"class_list":{"0":"post-254805","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-bsi","8":"first","9":"instock","10":"sold-individually","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/254805","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/254809"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=254805"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=254805"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=254805"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}