{"id":410715,"date":"2024-10-20T05:41:41","date_gmt":"2024-10-20T05:41:41","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bsi-22-30454110-dc\/"},"modified":"2024-10-26T10:29:30","modified_gmt":"2024-10-26T10:29:30","slug":"bsi-22-30454110-dc","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bsi-22-30454110-dc\/","title":{"rendered":"BSI 22\/30454110 DC"},"content":{"rendered":"
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
9<\/td>\n | Foreword <\/td>\n<\/tr>\n | ||||||
10<\/td>\n | Introduction <\/td>\n<\/tr>\n | ||||||
11<\/td>\n | 1 Scope 2 Normative references <\/td>\n<\/tr>\n | ||||||
12<\/td>\n | 3 Terms, definitions and abbreviated terms 3.1 Terms and definition 3.2 Abbreviated terms <\/td>\n<\/tr>\n | ||||||
14<\/td>\n | 4 Requirements and specifications clause for steel outfitting 4.1 General 4.2 Handrails <\/td>\n<\/tr>\n | ||||||
15<\/td>\n | 4.2.1 General requirements <\/td>\n<\/tr>\n | ||||||
16<\/td>\n | 4.2.2 End of handrails <\/td>\n<\/tr>\n | ||||||
17<\/td>\n | 4.2.3 Removable type handrails <\/td>\n<\/tr>\n | ||||||
20<\/td>\n | 4.2.4 Alternative dimension and thickness of handrail <\/td>\n<\/tr>\n | ||||||
21<\/td>\n | 4.2.5 Structural requirements 4.2.6 Tests of handrails 4.3 Safety gate <\/td>\n<\/tr>\n | ||||||
23<\/td>\n | 4.3.1 Structural requirements 4.3.2 Tests of handrails 4.4 Stairs <\/td>\n<\/tr>\n | ||||||
24<\/td>\n | 4.4.1 General requirements 4.4.2 Stair width and headroom clearances <\/td>\n<\/tr>\n | ||||||
26<\/td>\n | 4.4.3 Nosing 4.4.4 Treads and landings <\/td>\n<\/tr>\n | ||||||
28<\/td>\n | 4.4.5 Structural requirements 4.4.6 Tests of stairs 4.5 Spiral stairs <\/td>\n<\/tr>\n | ||||||
29<\/td>\n | 4.5.1 General requirements 4.5.2 Sizes of stairs <\/td>\n<\/tr>\n | ||||||
32<\/td>\n | 4.5.3 Nosing 4.5.4 Treads and landings <\/td>\n<\/tr>\n | ||||||
33<\/td>\n | 4.6 Vertical ladders <\/td>\n<\/tr>\n | ||||||
35<\/td>\n | 4.6.1 General requirements <\/td>\n<\/tr>\n | ||||||
38<\/td>\n | 4.6.2 Stiles (stringer) <\/td>\n<\/tr>\n | ||||||
39<\/td>\n | 4.6.3 Rungs 4.6.4 Spacing between the ladder and any permanent obstruction <\/td>\n<\/tr>\n | ||||||
40<\/td>\n | 4.6.5 Fall protection device <\/td>\n<\/tr>\n | ||||||
41<\/td>\n | 4.6.6 Structure requirements 4.6.7 Tests of vertical ladders 4.7 Grating <\/td>\n<\/tr>\n | ||||||
42<\/td>\n | 4.7.1 General requirements <\/td>\n<\/tr>\n | ||||||
43<\/td>\n | 4.7.2 Grating openings <\/td>\n<\/tr>\n | ||||||
44<\/td>\n | 4.7.3 Penetrations <\/td>\n<\/tr>\n | ||||||
45<\/td>\n | 4.7.4 Tests of gratings 4.8 Manhole <\/td>\n<\/tr>\n | ||||||
48<\/td>\n | 4.9 Connection method 4.9.1 Selection connection method for steel outfitting <\/td>\n<\/tr>\n | ||||||
49<\/td>\n | 4.9.2 Self-loosening prevention 4.9.3 Nuts fastening <\/td>\n<\/tr>\n | ||||||
50<\/td>\n | 4.9.4 Height of nut <\/td>\n<\/tr>\n | ||||||
51<\/td>\n | 4.9.5 Grating fastener 4.9.6 Bolt location and direction <\/td>\n<\/tr>\n | ||||||
52<\/td>\n | 4.9.7 Allowable capacity 5 Requirements and specifications clause for aluminium outfitting 5.1 General <\/td>\n<\/tr>\n | ||||||
53<\/td>\n | 5.2 Handrails <\/td>\n<\/tr>\n | ||||||
54<\/td>\n | 5.2.1 General requirements <\/td>\n<\/tr>\n | ||||||
55<\/td>\n | 5.2.2 Shape of rails and fasteners <\/td>\n<\/tr>\n | ||||||
56<\/td>\n | 5.2.3 End of handrails <\/td>\n<\/tr>\n | ||||||
58<\/td>\n | 5.2.4 Removable type handrails <\/td>\n<\/tr>\n | ||||||
59<\/td>\n | 5.2.5 Handrails on stairs <\/td>\n<\/tr>\n | ||||||
63<\/td>\n | 5.2.6 Structural requirements 5.2.7 Tests of handrails <\/td>\n<\/tr>\n | ||||||
64<\/td>\n | 5.3 Safety gate <\/td>\n<\/tr>\n | ||||||
65<\/td>\n | 5.3.1 Structural requirements 5.3.2 Tests of handrails 5.4 Stairs <\/td>\n<\/tr>\n | ||||||
67<\/td>\n | 5.4.1 General requirements 5.4.2 Stair width and headroom clearances 5.4.3 Nosing <\/td>\n<\/tr>\n | ||||||
68<\/td>\n | 5.4.4 Treads and landings <\/td>\n<\/tr>\n | ||||||
71<\/td>\n | 5.4.5 Structural requirements 5.4.6 Tests of stairs 5.5 Vertical ladders <\/td>\n<\/tr>\n | ||||||
73<\/td>\n | 5.5.1 General requirements <\/td>\n<\/tr>\n | ||||||
76<\/td>\n | 5.5.2 Stiles (stringer) <\/td>\n<\/tr>\n | ||||||
77<\/td>\n | 5.5.3 Rungs 5.5.4 Spacing between the ladder and any permanent obstruction <\/td>\n<\/tr>\n | ||||||
78<\/td>\n | 5.5.5 Fall protection device <\/td>\n<\/tr>\n | ||||||
79<\/td>\n | 5.5.6 Structure requirements 5.5.7 Tests of vertical ladders 5.6 Grating 5.6.1 General requirements <\/td>\n<\/tr>\n | ||||||
80<\/td>\n | 5.6.2 Grating openings 5.6.3 Penetrations <\/td>\n<\/tr>\n | ||||||
81<\/td>\n | 5.6.4 Tests of gratings <\/td>\n<\/tr>\n | ||||||
82<\/td>\n | 6 Material requirement for carbon steel tertiary outfitting structure 6.1 General 6.2 References 6.3 Material designation for tertiary structure <\/td>\n<\/tr>\n | ||||||
83<\/td>\n | 6.4 Manufacturing 6.5 Test and inspection 6.5.1 Chemical composition 6.5.2 Mechanical test <\/td>\n<\/tr>\n | ||||||
85<\/td>\n | 6.5.3 Specification of dimensional tolerance 6.5.4 Inspection and repair 6.6 Identification 6.7 Material table and MDS <\/td>\n<\/tr>\n | ||||||
86<\/td>\n | 6.8 Material certificate <\/td>\n<\/tr>\n | ||||||
87<\/td>\n | 7 Material requirement for aluminium tertiary outfitting structure 7.1 General 7.2 Material designation for tertiary structure 7.3 Manufacturing 7.4 Test and inspection 7.4.1 Chemical composition <\/td>\n<\/tr>\n | ||||||
88<\/td>\n | 7.4.2 Mechanical test <\/td>\n<\/tr>\n | ||||||
89<\/td>\n | 7.4.3 Specification of dimensional tolerance 7.4.4 Inspection and repair 7.5 Identification 7.6 Material table and MDS <\/td>\n<\/tr>\n | ||||||
90<\/td>\n | 7.7 Material certificate <\/td>\n<\/tr>\n | ||||||
91<\/td>\n | 8 Welding requirements 8.1 General 8.2 Welder qualification 8.3 Welding consumables \/ filler material 8.4 Welding procedures <\/td>\n<\/tr>\n | ||||||
92<\/td>\n | 8.5 Qualification of welding procedures 8.5.1 General requirements 8.5.2 Assembly of test pieces, examination and tests <\/td>\n<\/tr>\n | ||||||
94<\/td>\n | 8.5.3 Testing <\/td>\n<\/tr>\n | ||||||
96<\/td>\n | 8.5.4 Re-testing 8.5.5 Approval range <\/td>\n<\/tr>\n | ||||||
102<\/td>\n | 8.5.6 Welding procedure qualification record (WPQR) 9 Quality control and Inspection 9.1 Qualification requirement of inspector 9.1.1 Basis for qualification 9.1.2 Term of effectiveness 9.1.3 Associate inspector <\/td>\n<\/tr>\n | ||||||
103<\/td>\n | 9.1.4 Eye examination 9.1.5 Verification authority 9.2 Inspector responsibility 9.3 Items to be furnished to the inspector 9.4 Qualification of NDT inspector 9.5 Execution methods for the extent of inspection 9.6 Extent of inspection per method <\/td>\n<\/tr>\n | ||||||
104<\/td>\n | 9.7 Acceptance limitation 9.7.1 VT and MT acceptance criteria for structural steel welds <\/td>\n<\/tr>\n | ||||||
106<\/td>\n | 9.7.2 UT acceptance criteria for structural steel welds <\/td>\n<\/tr>\n | ||||||
107<\/td>\n | 9.8 Welding inspection report 9.9 Visual inspection in procurement 9.9.1 General <\/td>\n<\/tr>\n | ||||||
108<\/td>\n | 9.9.2 Checklist 9.9.3 Inspection volumes 9.10 Visual inspection after installation 9.10.1 General 9.10.2 Checklist <\/td>\n<\/tr>\n | ||||||
109<\/td>\n | 9.10.3 Inspection point <\/td>\n<\/tr>\n | ||||||
111<\/td>\n | 10 Test procedure 10.1 General 10.2 Handrails 10.2.1 General requirement 10.2.2 Test preparation <\/td>\n<\/tr>\n | ||||||
112<\/td>\n | 10.2.3 Test condition <\/td>\n<\/tr>\n | ||||||
113<\/td>\n | 10.2.4 Test sequence <\/td>\n<\/tr>\n | ||||||
114<\/td>\n | 10.2.5 Failure criteria 10.3 Stairs 10.3.1 General requirement 10.3.2 Test preparation <\/td>\n<\/tr>\n | ||||||
115<\/td>\n | 10.3.3 Test condition <\/td>\n<\/tr>\n | ||||||
116<\/td>\n | 10.3.4 Test sequence 10.3.5 Failure criteria 10.4 Vertical ladder 10.4.1 General requirement 10.4.2 Test preparation <\/td>\n<\/tr>\n | ||||||
117<\/td>\n | 10.4.3 Test condition <\/td>\n<\/tr>\n | ||||||
119<\/td>\n | 10.4.4 Test sequence 10.4.5 Failure criteria <\/td>\n<\/tr>\n | ||||||
120<\/td>\n | 10.5 Grating 10.5.1 General requirement 10.5.2 Test preparation <\/td>\n<\/tr>\n | ||||||
121<\/td>\n | 10.5.3 Test condition <\/td>\n<\/tr>\n | ||||||
122<\/td>\n | 10.5.4 Test sequence <\/td>\n<\/tr>\n | ||||||
123<\/td>\n | 10.5.5 Failure criteria <\/td>\n<\/tr>\n | ||||||
124<\/td>\n | Annex\u20acA (informative) Quality Control Plan (QCP) for steel outfitting of tertiary item <\/td>\n<\/tr>\n | ||||||
133<\/td>\n | Annex\u20acB (informative) Practical drawings of steel outfitting items for fabrication <\/td>\n<\/tr>\n | ||||||
134<\/td>\n | Annex\u20acC (informative) Manhole code components design details <\/td>\n<\/tr>\n | ||||||
137<\/td>\n | Annex\u20acD (informative) Practical drawings of manhole for fabrication <\/td>\n<\/tr>\n | ||||||
143<\/td>\n | Annex\u20acE (informative) Practical drawings of aluminium outfitting items for fabrication <\/td>\n<\/tr>\n | ||||||
144<\/td>\n | Annex\u20acF (normative) MDS for structural steel \/ tertiary outfitting structural <\/td>\n<\/tr>\n | ||||||
151<\/td>\n | Annex\u20acG (normative) MDS for structural Aluminium \/ tertiary outfitting structural <\/td>\n<\/tr>\n | ||||||
154<\/td>\n | Annex\u20acH (informative) Recommended welding procedure specification (WPS) <\/td>\n<\/tr>\n | ||||||
156<\/td>\n | Annex\u20acI (informative) Test report <\/td>\n<\/tr>\n | ||||||
161<\/td>\n | Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" BS EN ISO 24201. Petroleum, petrochemical and natural gas industries. Bulk material for offshore projects. Tertiary outfitting structures<\/b><\/p>\n |