{"id":422343,"date":"2024-10-20T06:40:47","date_gmt":"2024-10-20T06:40:47","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/astm-e2126-14\/"},"modified":"2024-10-26T12:30:30","modified_gmt":"2024-10-26T12:30:30","slug":"astm-e2126-14","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/astm\/astm-e2126-14\/","title":{"rendered":"ASTM-E2126"},"content":{"rendered":"<\/p>\n

1.1 These test methods cover the evaluation of the shear stiffness, shear strength, and ductility of the vertical elements of lateral force resisting systems, including applicable shear connections and hold-down connections, under quasi-static cyclic (reversed) load conditions.<\/p>\n

1.2 These test methods are intended for specimens constructed from wood or metal framing braced with solid sheathing or other methods or structural insulated panels.<\/p>\n

1.3 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.<\/p>\n

1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.<\/span><\/p>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
1<\/td>\nScope
Referenced Documents
Terminology <\/td>\n<\/tr>\n
2<\/td>\nFIG. 1
FIG. 1 <\/td>\n<\/tr>\n
3<\/td>\nSummary of Test Method
FIG. 1 <\/td>\n<\/tr>\n
4<\/td>\nSignificance and Use
Specimen
FIG. 2 <\/td>\n<\/tr>\n
5<\/td>\nTest Setup
FIG. 2 <\/td>\n<\/tr>\n
6<\/td>\nProcedure
FIG. 3 <\/td>\n<\/tr>\n
7<\/td>\nFIG. 4 <\/td>\n<\/tr>\n
8<\/td>\nFIG. 5
FIG. 6 <\/td>\n<\/tr>\n
9<\/td>\nFIG. 7
FIG. 8 <\/td>\n<\/tr>\n
10<\/td>\nCalculation
TABLE 1
TABLE 2
TABLE 3 <\/td>\n<\/tr>\n
11<\/td>\nReport <\/td>\n<\/tr>\n
12<\/td>\nPrecision and Bias
Keywords
X1. DETERMINATION OF FIRST MAJOR EVENT
X1.1
X2. SELECTION OF CYCLING METHOD
X2.1 Test Method A Versus Test Method B <\/td>\n<\/tr>\n
13<\/td>\nX2.2 Test Method C
X3. TEST SETUP
X3.1
REFERENCES <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

E2126-08 Standard Test Methods for Cyclic (Reversed) Load Test for Shear Resistance of Vertical Elements of the Lateral Force Resisting Systems for Buildings<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
ASTM<\/b><\/a><\/td>\n2008<\/td>\n14<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":422354,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[1236,2637],"product_tag":[],"class_list":{"0":"post-422343","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-91-060-10","7":"product_cat-astm","9":"first","10":"instock","11":"sold-individually","12":"shipping-taxable","13":"purchasable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/422343","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/422354"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=422343"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=422343"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=422343"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}