This specification covers calcium silicate block and pipe thermal insulation for use on surfaces. Thermal insulation shall be of the following types: Type I; Type IA; and Type II. Calcium silicate thermal insulation shall consist principally of hydrous calcium silicate usually with the incorporation of fibrous reinforcement. The insulation shall conform to the physical requirements specified. Following test methods shall be performed: block insulation; pipe insulation; apparent thermal conductivity; linear shrinkage after heat soaking; flexural strength; compressive strength; mass loss by tumbling; hot surface performance; surface burning characteristics; stress corrosion performance; and moisture content by dry weight.

This abstract is a brief summary of the referenced standard. It is informational only and not an official part of the standard; the full text of the standard itself must be referred to for its use and application. ASTM does not give any warranty express or implied or make any representation that the contents of this abstract are accurate, complete or up to date.

1. Scope

1.1 This specification covers calcium silicate block and pipe thermal insulation for use on surfaces with temperatures between 80 and 1700 Ā° F (27 to 927 Ā° C), unless otherwise agreed upon between the manufacturer and the purchaser.

1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.

1.3 The following safety hazards caveat pertains only to the test method (Section 12) described in this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

2. Referenced Documents (purchase separately) The documents listed below are referenced within the subject standard but are not provided as part of the standard.

ASTM Standards

C165 Test Method for Measuring Compressive Properties of Thermal Insulations C168 Terminology Relating to Thermal Insulation C177 Test Method for Steady-State Heat Flux Measurements and Thermal Transmission Properties by Means of the Guarded-Hot-Plate Apparatus C203 Test Methods for Breaking Load and Flexural Properties of Block-Type Thermal Insulation C302 Test Method for Density and Dimensions of Preformed Pipe-Covering-Type Thermal Insulation C303 Test Method for Dimensions and Density of Preformed Block and Board-Type Thermal Insulation C335 Test Method for Steady-State Heat Transfer Properties of Pipe Insulation C356 Test Method for Linear Shrinkage of Preformed High-Temperature Thermal Insulation Subjected to Soaking Heat C390 Practice for Sampling and Acceptance of Thermal Insulation Lots C411 Test Method for Hot-Surface Performance of High-Temperature Thermal Insulation C421 Test Method for Tumbling Friability of Preformed Block-Type and Preformed Pipe-Covering-Type Thermal Insulation C446 Test Method for Breaking Load and Calculated Modulus of Rupture of Preformed Insulation for Pipes C518 Test Method for Steady-State Thermal Transmission Properties by Means of the Heat Flow Meter Apparatus C585 Practice for Inner and Outer Diameters of Thermal Insulation for Nominal Sizes of Pipe and Tubing C795 Specification for Thermal Insulation for Use in Contact with Austenitic Stainless Steel C870 Practice for Conditioning of Thermal Insulating Materials C1045 Practice for Calculating Thermal Transmission Properties Under Steady-State Conditions C1058 Practice for Selecting Temperatures for Evaluating and Reporting Thermal Properties of Thermal Insulation C1114 Test Method for Steady-State Thermal Transmission Properties by Means of the Thin-Heater Apparatus C1616 Test Method for Determining the Moisture Content of Organic and Inorganic Insulation Materials by Weight C1617 Practice for Quantitative Accelerated Laboratory Evaluation of Extraction Solutions Containing Ions Leached from Thermal Insulation on Aqueous Corrosion of Metals E84 Test Method for Surface Burning Characteristics of Building Materials E136 Test Method for Behavior of Materials in a Vertical Tube Furnace at 750C

Keywords

block and pipe thermal insulation; calcium silicate; thermal conductivity; thermal insulation; Block and pipe thermal insulation–specifications; Calcium silicate thermal insulation; Pipe thermal insulati