Shopping Cart

No products in the cart.

AWWA C710 2009

$75.83

AWWA C710-09: Cold Water Meters-Displacement Type, Plastic Main Case

Published By Publication Date Number of Pages
AWWA 2009 40
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This standard describes the various types and classes of cold-water displacement meters with plastic main cases, in sizes 1/2 in. (13 mm) through 1 in. (25 mm), for water utility customer service, and the materials and workmanship employed in their fabrication. The displacement meters described, known as nutating-disc or oscillating-piston meters, are positive in action because the pistons and discs displace or carry over a fixed quantity of water for each nutation or oscillation when operated under positive pressure.

PDF Catalog

PDF Pages PDF Title
1 ANSI/AWWA C710-09
3 Committee Personnel
5 Contents
7 Foreword
I. Introduction.
9 II. Special Issues.
10 III. Use of This Standard.
11 IV. Major Revisions.
V. Comments.
13 AWWA Standard Cold-Water Meters-Displacement
Type, Plastic Main Case

SECTION 1: GENERAL
Sec. 1.1 Scope
Sec. 1.2 Purpose
Sec. 1.3 Application
14 SECTION 2: REFERENCES
Sec. 2.1 Standards
16 Sec. 2.2 ASTM Test Standards
SECTION 3: DEFINITIONS
17 SECTION 4: REQUIREMENTS
Sec. 4.1 Materials
21 Sec. 4.2 General Design
22 Table 1 Characteristics of displacement-type meters
23 Table 2 Dimensional design limits for meters and external connections
24 Sec. 4.3 Detailed Design
25 Table 3 Maximum indication on initial dial and minimum register capacity
26 SECTION 5: VERIFICATION
Sec. 5.1 Rejection
SECTION 6: DELIVERY
Sec. 6.1 Marking
Sec. 6.2 Packaging and Shipping
Sec. 6.3 Affidavit of Compliance
27 APPENDIX A
Bibliography
29 APPENDIX B
Supplemental Information
SECTION B.1: UNITS OF MEASURE
SECTION B.2: TESTS
Sec. B.2.1 Capacity and Pressure-Loss Tests
30 Sec. B.2.2 Pressure Tests
Sec. B.2.3 Accuracy Tests
SECTION B.3: TESTING EQUIPMENT
31 SECTION B.4: REGISTRATION ACCURACY
Sec. B.4.1 Excessive Wear
Sec. B.4.2 Temperature Extremes
32 Sec. B.4.3 Corrosion
Sec. B.4.4 Materials in Suspension
Sec. B.4.5 Entrained Air
33 Table B.1. Most frequently used intervals between meter tests
SECTION B.5: PERIODIC TESTS
Sec. B.5.1 Time Intervals
SECTION B.6: METER STORAGE
34 SECTION B.7: MATERIALS
SECTION B.8: INSTALLATION
Sec. B.8.1 Electrical Grounded Pipe Systems
35 Sec. B.8.2 Misaligned Pipes
Sec. B.8.3 Meter Installation Methods
36 Sec. B.8.4 Placing Meter in Service
AWWA C710 2009