BS 7870-8.2:2003

$142.49

LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for multicore and multipair cables for installation above and below ground – Single wire armoured and PVC sheathed multipair cable with copper conductors – Section 8.2 Single wire armoured and PVC sheathed multipair cable with copper conductors

Published By Publication Date Number of Pages
BSI 2003 24
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This section of BS 7870 specifies requirements for the construction, dimensions and mechanical and physical properties of multipair polyethylene insulated, PVC sheathed cables. It specifies requirements for multipair cables (4 pairs to 61 pairs) having copper conductors with filled and unfilled interstices, normal and increased insulation and bedding thicknesses and either steel or aluminium wire armour.

This section of BS 7870 is applicable to cables for use underground in wet conditions and also for withstanding high levels of induced voltage.

NOTE A “guide to use” is given in Annex A.

PDF Catalog

PDF Pages PDF Title
1 BRITISH STANDARD
2 Committees responsible
3 Contents
4 Foreword
5 1 Scope
2 Normative references
3 Rated voltage
4 Conductors
5 Insulation
6 6 Identification of pairs
7 7 Assembly of pairs, fillers and binders
8 Bedding layer
9 Armouring
10 Oversheath
8 11 Marking
11.1 External marking
11.2 Identification of year of manufacture
11.3 Mark of an approval organization
9 11.4 Additional marking
12 Dimensions
10 Table 1
Table 2
11 Table 3
12 13 Tests
Table 4
14 Routine tests
14.1 General
14.2 Conductor resistance
13 14.3 Insulation resistance
Table 5
14.4 Voltage test
14.5 Spark test on oversheath
14.6 Voltage test on oversheath
14.7 Cable markings
15 Sample tests
15.1 General
15.2 Conductor material and construction
14 15.3 Insulation
15.4 Capacitance unbalance
15.5 Pair identification
15.6 Laid-up pairs
15.7 Bedding layer
15.8 Armour wire
15 Table 6
15.9 Oversheath
15.10 Insulation resistance
15.11 Water penetration test for filled cables
16 Type tests
16.1 General
16.2 Insulation
16 Table 7
16.3 Bedding
16.4 Mass of zinc coating of galvanized steel armour wires
Table 8
16.5 Wrapping test for galvanized steel armour wires
16.6 Tensile strength of aluminium wire
17 16.7 Oversheath
16.8 Mutual capacitance
Table 9
16.9 Inductance
16.10 Compatibility of materials test for filled cables
18 Annex A (informative) Guide to use
A.1 General
A.2 Recommendations for selection
A.3 Recommendations for storage, transport and disposal
A.4 Recommendations for cable laying and installation
19 A.5 Tests after installation (before jointing)
A.6 Tests after installation (after jointing)
20 Annex B (normative) Compatibility of filling materials
B.1 General
B.2 Samples
B.3 Procedure
21 Annex C (normative) Water penetration test
Figure C.1 Water penetration test arrangement
23 Bibliography