BS EN 60317-38:2014
$102.76
Specifications for particular types of winding wires – Polyester or polyesterimide overcoated with polyamide-imide, enamelled round copper wire, class 200, with a bonding layer
Published By | Publication Date | Number of Pages |
BSI | 2014 | 16 |
This part of IEC 60317 specifies the requirements of enamelled round copper winding wire of class 200 with a triple coating. The underlying coating is based on polyester or polyesterimide resin, which may be modified providing it retains the chemical identity of the original resin and meets all specified wire requirements. The secondary coating is based on polyamide-imide resin. The third coating is a bonding layer based on a thermoplastic or thermosetting resin.
NOTE A modified resin is a resin that has undergone a chemical change, or contains one or more additives to enhance certain performance or application characteristics.
The range of nominal conductor diameters covered by this part is:
-
Grade 1B: 0,050 mm up to and including 1,600 mm;
-
Grade 2B: 0,050 mm up to and including 1,600 mm.
The nominal conductor diameters are specified in Clause 4 of IEC 60317-0-1:2013.
PDF Catalog
PDF Pages | PDF Title |
---|---|
6 | English CONTENTS |
7 | INTRODUCTION |
8 | 1 Scope 2 Normative references 3 Terms, definitions, general notes and appearance 3.1 Terms and definitions 3.2 General notes 3.2.1 Methods of test 3.2.2 Winding wire |
9 | 3.3 Appearance 4 Dimensions 5 Electrical resistance 6 Elongation 7 Springiness 8 Flexibility and adherence 9 Heat shock 10 Cut-through 11 Resistance to abrasion (nominal conductor diameters from 0,250 mm up to and including 1,600 mm) |
10 | 12 Resistance to solvents 13 Breakdown voltage 14 Continuity of insulation 15 Temperature index 16 Resistance to refrigerants Table 1 – Resistance to abrasion |
11 | 17 Solderability 18 Heat or solvent bonding 18.1 Heat bonding 18.1.1 Heat bonding strength of a helical coil |
12 | 18.1.2 Bond strength on a twisted coil Table 2 – Loads |
13 | 18.2 Solvent bonding 19 Dielectric dissipation factor 20 Resistance to transformer oil 21 Loss of mass 23 Pin hole test 30 Packaging |
14 | Bibliography |