{"id":111711,"date":"2024-10-18T16:15:25","date_gmt":"2024-10-18T16:15:25","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/ieee-1613-2009\/"},"modified":"2024-10-24T22:02:26","modified_gmt":"2024-10-24T22:02:26","slug":"ieee-1613-2009","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/ieee\/ieee-1613-2009\/","title":{"rendered":"IEEE 1613 2009"},"content":{"rendered":"
Revision Standard – Active. Service conditions, electrical ratings, thermal ratings, and environmental testing requirements are defined for communications networking devices to be installed in electric power substations. This standard establishes a common reproducible basis for designing and evaluating communications networking devices and the communications ports of protective relays for use in this harsh environment.<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
1<\/td>\n | IEEE Stds 1613-2009 Front Cover \n <\/td>\n<\/tr>\n | ||||||
2<\/td>\n | Title Page <\/td>\n<\/tr>\n | ||||||
3<\/td>\n | Abstract\/Keywords <\/td>\n<\/tr>\n | ||||||
5<\/td>\n | Introduction <\/td>\n<\/tr>\n | ||||||
6<\/td>\n | Notice to users Laws and regulations Copyrights Updating of IEEE documents Errata Interpretations Patents Participants <\/td>\n<\/tr>\n | ||||||
9<\/td>\n | Contents <\/td>\n<\/tr>\n | ||||||
11<\/td>\n | Important Notice 1. Overview 1.1 Scope 1.2 Purpose <\/td>\n<\/tr>\n | ||||||
12<\/td>\n | 2. Definitions and word usage 2.1 Definitions 2.2 Word usage <\/td>\n<\/tr>\n | ||||||
13<\/td>\n | 3. Service conditions (adapted from IEEE Std C37.90-2007 [B8]) 3.1 Usual service conditions <\/td>\n<\/tr>\n | ||||||
14<\/td>\n | 3.2 Other conditions 3.3 Altitude <\/td>\n<\/tr>\n | ||||||
15<\/td>\n | 4. Electrical ratings of control power inputs\u2014adapted from IEEE Std C37.90-2007 [B8] <\/td>\n<\/tr>\n | ||||||
16<\/td>\n | 4.1 DC rated control power inputs 4.2 Allowable ac component in dc control voltage supply 4.3 AC rated control power inputs 5. Insulation tests 5.1 General requirements <\/td>\n<\/tr>\n | ||||||
17<\/td>\n | 5.2 Dielectric power frequency test <\/td>\n<\/tr>\n | ||||||
18<\/td>\n | 5.3 Impulse voltage test <\/td>\n<\/tr>\n | ||||||
20<\/td>\n | 6. Surge withstand capability (SWC) tests 6.1 Scope 6.2 Purpose 6.3 Test waveforms <\/td>\n<\/tr>\n | ||||||
22<\/td>\n | 6.4 Test generator characteristics <\/td>\n<\/tr>\n | ||||||
23<\/td>\n | 6.5 Verification of test generator characteristics <\/td>\n<\/tr>\n | ||||||
24<\/td>\n | 6.6 Equipment to be tested 6.7 Test points 6.8 Application of test wave 6.9 Conditions of tests <\/td>\n<\/tr>\n | ||||||
25<\/td>\n | 6.10 Coupling to test generator <\/td>\n<\/tr>\n | ||||||
29<\/td>\n | 6.11 Test procedures <\/td>\n<\/tr>\n | ||||||
31<\/td>\n | 6.12 Device performance classes 6.13 Conditions to be met (acceptance criteria) <\/td>\n<\/tr>\n | ||||||
32<\/td>\n | 6.14 Test records <\/td>\n<\/tr>\n | ||||||
33<\/td>\n | 7. RF susceptibility tests 7.1 Scope 7.2 Purpose 7.3 Test severity level <\/td>\n<\/tr>\n | ||||||
34<\/td>\n | 7.4 Test equipment 7.5 Test setup <\/td>\n<\/tr>\n | ||||||
35<\/td>\n | 7.6 Test procedure <\/td>\n<\/tr>\n | ||||||
36<\/td>\n | 7.7 Device performance classes 7.8 Conditions to be met (acceptance criteria) <\/td>\n<\/tr>\n | ||||||
37<\/td>\n | 7.9 Test records <\/td>\n<\/tr>\n | ||||||
38<\/td>\n | 8. Electrostatic discharge tests <\/td>\n<\/tr>\n | ||||||
39<\/td>\n | 8.1 Electrostatic discharge disturbance tests 8.2 Test procedure <\/td>\n<\/tr>\n | ||||||
44<\/td>\n | 8.3 Device performance classes 8.4 Conditions to be met (acceptance criteria) <\/td>\n<\/tr>\n | ||||||
45<\/td>\n | 8.5 Test data records 9. Vibration and shock <\/td>\n<\/tr>\n | ||||||
46<\/td>\n | 10. Device cooling <\/td>\n<\/tr>\n | ||||||
47<\/td>\n | Annex A (normative) Verification of test generator characteristics <\/td>\n<\/tr>\n | ||||||
51<\/td>\n | Annex B (informative) Transceiver field strength <\/td>\n<\/tr>\n | ||||||
53<\/td>\n | Annex C (informative) Test waveform specification <\/td>\n<\/tr>\n | ||||||
54<\/td>\n | Annex D (informative) Field strength calibration, IEC 61000-4-3, 2002 [B5] <\/td>\n<\/tr>\n | ||||||
56<\/td>\n | Annex E (informative) Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" IEEE Standard Environmental and Testing Requirements for Communications Networking Devices Installed in Electric Power Substations<\/b><\/p>\n |