{"id":240844,"date":"2024-10-19T15:46:12","date_gmt":"2024-10-19T15:46:12","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-7870-8-52003\/"},"modified":"2024-10-25T10:31:44","modified_gmt":"2024-10-25T10:31:44","slug":"bs-7870-8-52003","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-7870-8-52003\/","title":{"rendered":"BS 7870-8.5:2003"},"content":{"rendered":"
This section of BS 7870 specifies requirements for the construction, dimensions and mechanical and physical properties of multicore cables with thermosetting insulation and non-halogenated sheaths, having reduced fire propagation performance, and low emission of smoke when affected by fire.<\/p>\n
It specifies requirements for:<\/p>\n
It specifies requirements for both Type 1 and Type 2 cables, which are defined as follows:<\/p>\n
The requirements specified in this section of BS 7870 are applicable to both Type 1 and Type 2 cables unless otherwise indicated.<\/p>\n
This section of BS 7870 is applicable to cables for use in and around power stations and other installations having similar cable densities.<\/p>\n
\nNOTE A \u201cguide to use\u201d is given in Annex A.<\/p>\n<\/blockquote>\n
PDF Catalog<\/h4>\n
\n
\n PDF Pages<\/th>\n PDF Title<\/th>\n<\/tr>\n \n 1<\/td>\n BRITISH STANDARD <\/td>\n<\/tr>\n \n 2<\/td>\n Committees responsible for this British Standard <\/td>\n<\/tr>\n \n 3<\/td>\n Contents <\/td>\n<\/tr>\n \n 5<\/td>\n 1 Scope
2 Normative references <\/td>\n<\/tr>\n\n 6<\/td>\n 3 Voltage designation
4 Conductors
5 Insulation
6 Identification of cores
7 Assembly of cores, fillers and binders
8 Bedding layer (optional for unarmoured cables) <\/td>\n<\/tr>\n\n 7<\/td>\n 9 Armouring
10 Oversheath
11 Marking
11.1 External marking
11.2 Identification of year of manufacture <\/td>\n<\/tr>\n\n 8<\/td>\n 11.3 Mark of an approval organization
11.4 Additional marking
12 Dimensions <\/td>\n<\/tr>\n\n 9<\/td>\n Table 1 – Construction of 1.5 mm
Table 2 – Construction of 2.5 mm
Table 3 – Construction of 4 mm <\/td>\n<\/tr>\n\n 10<\/td>\n Table 4 – Construction of 1.5 mm
Table 5 – Construction of 2.5 mm
Table 6 – Construction of 4 mm <\/td>\n<\/tr>\n\n 11<\/td>\n Table 7 – Construction of 2.5 mm
Table 8 – Construction of 2.5 mm <\/td>\n<\/tr>\n\n 12<\/td>\n 13 Tests
Table 9 – Schedule of tests <\/td>\n<\/tr>\n\n 13<\/td>\n 14 Routine tests
14.1 General
14.2 Conductor resistance
14.3 Insulation resistance (Type 2 only)
14.4 Voltage test
14.5 Spark test on oversheath
14.6 Cable markings
15 Sample tests
15.1 General
15.2 Conductor material and construction
15.3 Insulation
15.4 Core identification <\/td>\n<\/tr>\n\n 14<\/td>\n 15.5 Laid-up cores
15.6 Bedding layer
15.7 Armour wire
Table 10 – Diameter of armour wire
15.8 Oversheath
15.9 Tests under fire conditions <\/td>\n<\/tr>\n\n 15<\/td>\n 16 Type tests
16.1 General
16.2 Insulation <\/td>\n<\/tr>\n\n 16<\/td>\n Table 11 – Requirements for non-electrical tests for thermosetting insulation <\/td>\n<\/tr>\n \n 17<\/td>\n 16.3 Star capacitance
16.4 Bedding <\/td>\n<\/tr>\n\n 18<\/td>\n Table 12 – Requirements for non-electrical tests for non-halogenated bedding and oversheath <\/td>\n<\/tr>\n \n 21<\/td>\n 16.5 Mass of zinc coating of galvanized steel armour wires
Table 13 – Mass of zinc coating
16.6 Wrapping test for galvanized steel armour wires
16.7 Oversheath
16.8 Compatibility test (Type 1 only)
Table 14 – Requirements for compatibility of insulation and oversheath
16.9 Abrasion resistance <\/td>\n<\/tr>\n\n 22<\/td>\n 16.10 Special type tests (Type 2 only)
Table 15 – Special type test for Type 2 cables
16.11 Tests under fire conditions <\/td>\n<\/tr>\n\n 24<\/td>\n Annex A (informative)
Guide to use
A.1 General
A.2 Recommendations for selection
A.2.1 Permissible application
A.2.2 Maximum permissible voltage
A.3 Recommendations for storage, transport and disposal
A.3.1 Storage
A.3.2 Transport
A.3.3 Incineration of scrap cable
A.3.4 Cable end sealing
A.4 Recommendations for cable laying and installation
A.4.1 General
A.4.2 Environment conditions <\/td>\n<\/tr>\n\n 25<\/td>\n A.4.3 Pulling tensions
A.4.4 Bending radii
A.4.5 Cable installation <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for multicore and multipair cables for installation above and below ground – Single wire armoured and unarmoured multicore cables with copper conductors and non-halogenated sheath – Section 8.5 Single wire armoured and unarmoured multicore cables with copper conductors and non-halogenated sheath<\/b><\/p>\n
\n\n
\n Published By<\/td>\n Publication Date<\/td>\n Number of Pages<\/td>\n<\/tr>\n \n BSI<\/b><\/a><\/td>\n 2003<\/td>\n 28<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":240849,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[493,2641],"product_tag":[],"class_list":{"0":"post-240844","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-29-060-20","7":"product_cat-bsi","9":"first","10":"instock","11":"sold-individually","12":"shipping-taxable","13":"purchasable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/240844","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/240849"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=240844"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=240844"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=240844"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}