{"id":241596,"date":"2024-10-19T15:49:27","date_gmt":"2024-10-19T15:49:27","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-en-61000-4-222011\/"},"modified":"2024-10-25T10:39:19","modified_gmt":"2024-10-25T10:39:19","slug":"bs-en-61000-4-222011","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-en-61000-4-222011\/","title":{"rendered":"BS EN 61000-4-22:2011"},"content":{"rendered":"

IEC 61000-4-22:2010 considers immunity tests and emission measurements for electric and\/or electronic equipment. Only radiated phenomena are considered. It establishes the required test procedures for using fully anechoic rooms for performing radiated immunity testing and radiated emission measurements. IEC 61000-4-22:2010 establishes a common validation procedure, equipment under test (EUT) set-up requirements, and measurement methods for fully anechoic rooms (FARs) when both radiated electromagnetic emission measurements and radiated electromagnetic immunity tests will be performed in the same FAR. As a basic measurement standard, this part of IEC 61000 does not intend to specify the test levels or emission limits to be applied to particular apparatus or system(s). Its main goal is to provide general measurement procedures to all concerned product committees of IEC or CISPR. Specific product requirements and test conditions are defined by the responsible product committees. The methods described in this standard are appropriate for radiated emission measurements and immunity tests in the frequency range of 30 MHz to 18 GHz. IEC 61000-4-22:2010 has the status of a basic EMC publication in accordance with IEC Guide 107, Electromagnetic compatibility – Guide to the drafting of electromagnetic compatibility publications.<\/p>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
6<\/td>\nEnglish
CONTENTS <\/td>\n<\/tr>\n
8<\/td>\nINTRODUCTION <\/td>\n<\/tr>\n
10<\/td>\n1 Scope
2 Normative references <\/td>\n<\/tr>\n
11<\/td>\n3 Terms and definitions <\/td>\n<\/tr>\n
12<\/td>\n4 FAR applications
4.1 Measurand for radiated immunity testing <\/td>\n<\/tr>\n
13<\/td>\n4.2 Measurand for radiated emission measurements
5 FAR validation\/calibration procedure
5.1 General
5.2 Validation set-ups <\/td>\n<\/tr>\n
14<\/td>\nFigures
Figure 1 \u2013 Type 1 validation block diagramme
Figure 2 \u2013 Type 2 validation block diagramme <\/td>\n<\/tr>\n
15<\/td>\nFigure 3 \u2013 Type 3 validation block diagramme
Figure 4 \u2013 Type 4 validation block diagramme <\/td>\n<\/tr>\n
17<\/td>\n5.3 Test facility description
Tables
Table 1 \u2013 Components required for the different validation set-up types <\/td>\n<\/tr>\n
18<\/td>\n5.4 Definition of quantities to be determined by the FAR validation procedure <\/td>\n<\/tr>\n
19<\/td>\n5.5 Required sampling positions for FAR validation <\/td>\n<\/tr>\n
20<\/td>\n5.6 FAR validation procedure
Figure 5 \u2013 Locations of the sampling points for FAR validation <\/td>\n<\/tr>\n
22<\/td>\n5.7 Validation requirement <\/td>\n<\/tr>\n
23<\/td>\n6 Test set-up
Table 2 \u2013 Validation criteria <\/td>\n<\/tr>\n
25<\/td>\nFigure 6 \u2013 Example test set-up for table-top equipment <\/td>\n<\/tr>\n
26<\/td>\nFigure 7 \u2013 Example test set-up for table-top equipment, top view
Figure 8 \u2013 Example test set-up for floor-standing equipment <\/td>\n<\/tr>\n
27<\/td>\nFigure 9 \u2013 Example test set-up for floor-standing equipment, top view <\/td>\n<\/tr>\n
28<\/td>\nAnnex A (normative) Radiated immunity tests <\/td>\n<\/tr>\n
30<\/td>\nFigure A.1 \u2013 Definition of dmeasurement for immunity tests <\/td>\n<\/tr>\n
33<\/td>\nAnnex B (normative) Radiated emission measurements <\/td>\n<\/tr>\n
34<\/td>\nFigure B.1 \u2013 Definition of dmeasurement for emission measurements <\/td>\n<\/tr>\n
36<\/td>\nAnnex C (informative) Background on the system transducer factor and simultaneous emissions\/immunity validation method <\/td>\n<\/tr>\n
39<\/td>\nAnnex D (informative) Measurement uncertainties
Figure\u00a0D.1 \u2013 Example of influence factors for emission measurements <\/td>\n<\/tr>\n
40<\/td>\nTable D.1 \u2013 Measurement instrumentation uncertainty in a FAR for radiated emission measurements in the frequency range 30\u00a0MHz to 1 000\u00a0MHz <\/td>\n<\/tr>\n
41<\/td>\nTable D.2 \u2013 Measurement instrumentation uncertainty in a FAR for radiated emission measurements in the frequency range 1\u00a0GHz to 18\u00a0GHz <\/td>\n<\/tr>\n
46<\/td>\nFigure D.2 \u2013 Example of influences upon the immunity test method <\/td>\n<\/tr>\n
47<\/td>\nTable D.3 \u2013 Measurement instrumentation uncertainty in a FAR for level setting for immunity testing in the frequency range 30\u00a0MHz to 1 000\u00a0MHz <\/td>\n<\/tr>\n
48<\/td>\nTable D.4 \u2013 Measurement instrumentation uncertainty in a FAR for level setting for immunity testing in the frequency range 1\u00a0GHz to 18\u00a0GHz <\/td>\n<\/tr>\n
52<\/td>\nBibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

Electromagnetic compatibility (EMC) – Testing and measurement techniques. Radiated emission and immunity measurements in fully anechoic rooms (FARs)<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
BSI<\/b><\/a><\/td>\n2011<\/td>\n54<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":241603,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[626,2641],"product_tag":[],"class_list":{"0":"post-241596","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-33-100-20","7":"product_cat-bsi","9":"first","10":"instock","11":"sold-individually","12":"shipping-taxable","13":"purchasable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/241596","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/241603"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=241596"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=241596"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=241596"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}