{"id":247499,"date":"2024-10-19T16:17:26","date_gmt":"2024-10-19T16:17:26","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bsi-pd-iec-tr-62627-022010\/"},"modified":"2024-10-25T11:24:35","modified_gmt":"2024-10-25T11:24:35","slug":"bsi-pd-iec-tr-62627-022010","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bsi-pd-iec-tr-62627-022010\/","title":{"rendered":"BSI PD IEC\/TR 62627-02:2010"},"content":{"rendered":"
This part of IEC 62627 reports the measurement results of two round robin test programs each carried out on SC\/PC and SC\/APC plug style fixed attenuators. The work was initiated at Cenelec TC 86BXA in June 2003 in order to get a clear understanding on the accuracy and repeatability of the spectral attenuation loss measurements on fixed attenuators.<\/p>\n
Out of these results recommendations are made for attenuation tolerance values that can be used in the performance standards.<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
4<\/td>\n | CONTENTS <\/td>\n<\/tr>\n | ||||||
6<\/td>\n | FOREWORD <\/td>\n<\/tr>\n | ||||||
8<\/td>\n | 1 Scope 2 Normative references 3 Background <\/td>\n<\/tr>\n | ||||||
9<\/td>\n | 4 Conclusions <\/td>\n<\/tr>\n | ||||||
10<\/td>\n | 5 Test results 5.1 Round robin test results of SC\/PC plug style attenuator <\/td>\n<\/tr>\n | ||||||
11<\/td>\n | Figures Figure 1 \u2013 15\u00a0dB attenuators \u2013 All lab. results \u2013 Common reference <\/td>\n<\/tr>\n | ||||||
13<\/td>\n | Figure 2 \u2013 5\u00a0dB attenuators \u2013 All lab. results <\/td>\n<\/tr>\n | ||||||
15<\/td>\n | Figure 3 \u2013 1\u00a0dB attenuators \u2013 All lab. results <\/td>\n<\/tr>\n | ||||||
17<\/td>\n | Tables Table 1 \u2013 Pass\/fail result <\/td>\n<\/tr>\n | ||||||
18<\/td>\n | Table 2 \u2013 Pass\/fail result with relaxed performance critera <\/td>\n<\/tr>\n | ||||||
19<\/td>\n | Figure 4 \u2013 Spectral scan of attenuators <\/td>\n<\/tr>\n | ||||||
20<\/td>\n | 5.2 Measurement results for SC\/APC plug style attenuators Figure 5 \u2013 Overview of PDL measurements results for SC\/PC plug style attenuators <\/td>\n<\/tr>\n | ||||||
22<\/td>\n | Figure 6 \u2013 1\u00a0dB attenuators \u2013 All lab. results \u2013 Common reference <\/td>\n<\/tr>\n | ||||||
24<\/td>\n | Figure 7 \u2013 5\u00a0dB attenuators \u2013 All lab. results \u2013 Common reference <\/td>\n<\/tr>\n | ||||||
26<\/td>\n | Figure 8 \u2013 15\u00a0dB attenuators \u2013 All lab. results <\/td>\n<\/tr>\n | ||||||
28<\/td>\n | Table 3 \u2013 Pass\/fail result of original specification <\/td>\n<\/tr>\n | ||||||
29<\/td>\n | Table 4 \u2013 Pass\/fail result with relaxed optical performance critera Table 5 \u2013 Pass\/fail result of original specification <\/td>\n<\/tr>\n | ||||||
30<\/td>\n | Table 6 \u2013 Pass\/fail result with relaxed optical performance critera <\/td>\n<\/tr>\n | ||||||
31<\/td>\n | Table 7 \u2013 LED measurements results at 1 310 nm (green colour = pass) Table 8 \u2013 LED measurements results at 1 550 nm (green colour = pass) <\/td>\n<\/tr>\n | ||||||
32<\/td>\n | Figure 9 \u2013 Overview of PDL measurements results for SC\/APC style attenuators <\/td>\n<\/tr>\n | ||||||
33<\/td>\n | 6 Mechanical interface issues with SC plug style attenuators Figure 10 \u2013 SC plug style attenuator dimensions Figure 11 \u2013 Possible configurations for plug style attenuator <\/td>\n<\/tr>\n | ||||||
34<\/td>\n | Table 9 \u2013 SC plug style attenuator behaviour analysis for different working configurations <\/td>\n<\/tr>\n | ||||||
35<\/td>\n | Annex A (informative) Individual test laboratory results of SC\/PC attenuators <\/td>\n<\/tr>\n | ||||||
36<\/td>\n | Figure A.1 \u2013 Laboratory A results with 2 nm resolution (LED light source) <\/td>\n<\/tr>\n | ||||||
37<\/td>\n | Figure A.2 \u2013 Laboratory A results with 2 nm resolution (LASER light source) Table A.1 \u2013 PDL measurements from Laboratory A <\/td>\n<\/tr>\n | ||||||
38<\/td>\n | Figure A.3 \u2013 Laboratory B results with 2 nm resolution <\/td>\n<\/tr>\n | ||||||
39<\/td>\n | Table A.2 \u2013 PDL measurements from Laboratory B <\/td>\n<\/tr>\n | ||||||
40<\/td>\n | Figure A.4 \u2013 Laboratory C results with 2 nm resolution <\/td>\n<\/tr>\n | ||||||
41<\/td>\n | Figure A.5 \u2013 Laboratory D results with 2 nm resolution Table A.3 \u2013 PDL measurements from laboratory E <\/td>\n<\/tr>\n | ||||||
42<\/td>\n | Figure A.6 \u2013 Laboratory E results with 2 nm resolution <\/td>\n<\/tr>\n | ||||||
43<\/td>\n | Figure A.7 \u2013 Laboratory E results with 10 nm resolution Table A.4 \u2013 PDL measurements from laboratory E <\/td>\n<\/tr>\n | ||||||
44<\/td>\n | Figure A.8 \u2013 Laboratory F results with 2 nm resolution <\/td>\n<\/tr>\n | ||||||
45<\/td>\n | Figure A.9 \u2013 Laboratory F results with 10 nm resolution Table A.5 \u2013 PDL measurements from Laboratory F <\/td>\n<\/tr>\n | ||||||
46<\/td>\n | Figure A.10 \u2013 Laboratory G results with 2 nm resolution <\/td>\n<\/tr>\n | ||||||
47<\/td>\n | Figure A.11 \u2013 Laboratory G results with 10 nm resolution Table A.6 \u2013 PDL measurements from laboratory G <\/td>\n<\/tr>\n | ||||||
48<\/td>\n | Annex B (informative) Individual test laboratory results of SC\/APC plug style attenuators <\/td>\n<\/tr>\n | ||||||
49<\/td>\n | Figure B.1 \u2013 Laboratory A results \u2013 Spectral measurements <\/td>\n<\/tr>\n | ||||||
50<\/td>\n | Figure B.2 \u2013 Laboratory A results \u2013 LED measurements Table B.1 \u2013 PDL measurements from Laboratory A <\/td>\n<\/tr>\n | ||||||
51<\/td>\n | Figure B.3 \u2013 Laboratory B results \u2013 Spectral measurements <\/td>\n<\/tr>\n | ||||||
52<\/td>\n | Figure B.4 \u2013 Laboratory B results \u2013 LED measurements Table B.2 \u2013 PDL measurements from Laboratory B <\/td>\n<\/tr>\n | ||||||
53<\/td>\n | Figure B.5 \u2013 Laboratory C results \u2013 Spectral measurements <\/td>\n<\/tr>\n | ||||||
54<\/td>\n | Figure B.6 \u2013 Laboratory C results \u2013 LED measurements Table B.3 \u2013 PDL measurements from Laboratory C <\/td>\n<\/tr>\n | ||||||
55<\/td>\n | Figure B.7 \u2013 Laboratory D results \u2013 Spectral measurements <\/td>\n<\/tr>\n | ||||||
56<\/td>\n | Figure B.8 \u2013 Laboratory D results \u2013 LED measurements Table B.4 \u2013 PDL measurements from Laboratory D <\/td>\n<\/tr>\n | ||||||
57<\/td>\n | Figure B.9 \u2013 Laboratory E results \u2013 Spectral measurements <\/td>\n<\/tr>\n | ||||||
58<\/td>\n | Figure B.10 \u2013 Laboratory E results \u2013 LED measurements Table B.5 \u2013 PDL measurements from Laboratory E <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" Fibre optic interconnecting devices and passive components – Report of round robin test results on SC plug style fixed attenuators<\/b><\/p>\n |