{"id":247499,"date":"2024-10-19T16:17:26","date_gmt":"2024-10-19T16:17:26","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bsi-pd-iec-tr-62627-022010\/"},"modified":"2024-10-25T11:24:35","modified_gmt":"2024-10-25T11:24:35","slug":"bsi-pd-iec-tr-62627-022010","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bsi-pd-iec-tr-62627-022010\/","title":{"rendered":"BSI PD IEC\/TR 62627-02:2010"},"content":{"rendered":"

This part of IEC 62627 reports the measurement results of two round robin test programs each carried out on SC\/PC and SC\/APC plug style fixed attenuators. The work was initiated at Cenelec TC 86BXA in June 2003 in order to get a clear understanding on the accuracy and repeatability of the spectral attenuation loss measurements on fixed attenuators.<\/p>\n

Out of these results recommendations are made for attenuation tolerance values that can be used in the performance standards.<\/p>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
4<\/td>\nCONTENTS <\/td>\n<\/tr>\n
6<\/td>\nFOREWORD <\/td>\n<\/tr>\n
8<\/td>\n1 Scope
2 Normative references
3 Background <\/td>\n<\/tr>\n
9<\/td>\n4 Conclusions <\/td>\n<\/tr>\n
10<\/td>\n5 Test results
5.1 Round robin test results of SC\/PC plug style attenuator <\/td>\n<\/tr>\n
11<\/td>\nFigures
Figure 1 \u2013 15\u00a0dB attenuators \u2013 All lab. results \u2013 Common reference <\/td>\n<\/tr>\n
13<\/td>\nFigure 2 \u2013 5\u00a0dB attenuators \u2013 All lab. results <\/td>\n<\/tr>\n
15<\/td>\nFigure 3 \u2013 1\u00a0dB attenuators \u2013 All lab. results <\/td>\n<\/tr>\n
17<\/td>\nTables
Table 1 \u2013 Pass\/fail result <\/td>\n<\/tr>\n
18<\/td>\nTable 2 \u2013 Pass\/fail result with relaxed performance critera <\/td>\n<\/tr>\n
19<\/td>\nFigure 4 \u2013 Spectral scan of attenuators <\/td>\n<\/tr>\n
20<\/td>\n5.2 Measurement results for SC\/APC plug style attenuators
Figure 5 \u2013 Overview of PDL measurements results for SC\/PC plug style attenuators <\/td>\n<\/tr>\n
22<\/td>\nFigure 6 \u2013 1\u00a0dB attenuators \u2013 All lab. results \u2013 Common reference <\/td>\n<\/tr>\n
24<\/td>\nFigure 7 \u2013 5\u00a0dB attenuators \u2013 All lab. results \u2013 Common reference <\/td>\n<\/tr>\n
26<\/td>\nFigure 8 \u2013 15\u00a0dB attenuators \u2013 All lab. results <\/td>\n<\/tr>\n
28<\/td>\nTable 3 \u2013 Pass\/fail result of original specification <\/td>\n<\/tr>\n
29<\/td>\nTable 4 \u2013 Pass\/fail result with relaxed optical performance critera
Table 5 \u2013 Pass\/fail result of original specification <\/td>\n<\/tr>\n
30<\/td>\nTable 6 \u2013 Pass\/fail result with relaxed optical performance critera <\/td>\n<\/tr>\n
31<\/td>\nTable 7 \u2013 LED measurements results at 1 310 nm (green colour = pass)
Table 8 \u2013 LED measurements results at 1 550 nm (green colour = pass) <\/td>\n<\/tr>\n
32<\/td>\nFigure 9 \u2013 Overview of PDL measurements results for SC\/APC style attenuators <\/td>\n<\/tr>\n
33<\/td>\n6 Mechanical interface issues with SC plug style attenuators
Figure 10 \u2013 SC plug style attenuator dimensions
Figure 11 \u2013 Possible configurations for plug style attenuator <\/td>\n<\/tr>\n
34<\/td>\nTable 9 \u2013 SC plug style attenuator behaviour analysis for different working configurations <\/td>\n<\/tr>\n
35<\/td>\nAnnex A (informative) Individual test laboratory results of SC\/PC attenuators <\/td>\n<\/tr>\n
36<\/td>\nFigure A.1 \u2013 Laboratory A results with 2 nm resolution (LED light source) <\/td>\n<\/tr>\n
37<\/td>\nFigure A.2 \u2013 Laboratory A results with 2 nm resolution (LASER light source)
Table A.1 \u2013 PDL measurements from Laboratory A <\/td>\n<\/tr>\n
38<\/td>\nFigure A.3 \u2013 Laboratory B results with 2 nm resolution <\/td>\n<\/tr>\n
39<\/td>\nTable A.2 \u2013 PDL measurements from Laboratory B <\/td>\n<\/tr>\n
40<\/td>\nFigure A.4 \u2013 Laboratory C results with 2 nm resolution <\/td>\n<\/tr>\n
41<\/td>\nFigure A.5 \u2013 Laboratory D results with 2 nm resolution
Table A.3 \u2013 PDL measurements from laboratory E <\/td>\n<\/tr>\n
42<\/td>\nFigure A.6 \u2013 Laboratory E results with 2 nm resolution <\/td>\n<\/tr>\n
43<\/td>\nFigure A.7 \u2013 Laboratory E results with 10 nm resolution
Table A.4 \u2013 PDL measurements from laboratory E <\/td>\n<\/tr>\n
44<\/td>\nFigure A.8 \u2013 Laboratory F results with 2 nm resolution <\/td>\n<\/tr>\n
45<\/td>\nFigure A.9 \u2013 Laboratory F results with 10 nm resolution
Table A.5 \u2013 PDL measurements from Laboratory F <\/td>\n<\/tr>\n
46<\/td>\nFigure A.10 \u2013 Laboratory G results with 2 nm resolution <\/td>\n<\/tr>\n
47<\/td>\nFigure A.11 \u2013 Laboratory G results with 10 nm resolution
Table A.6 \u2013 PDL measurements from laboratory G <\/td>\n<\/tr>\n
48<\/td>\nAnnex B (informative) Individual test laboratory results of SC\/APC plug style attenuators <\/td>\n<\/tr>\n
49<\/td>\nFigure B.1 \u2013 Laboratory A results \u2013 Spectral measurements <\/td>\n<\/tr>\n
50<\/td>\nFigure B.2 \u2013 Laboratory A results \u2013 LED measurements
Table B.1 \u2013 PDL measurements from Laboratory A <\/td>\n<\/tr>\n
51<\/td>\nFigure B.3 \u2013 Laboratory B results \u2013 Spectral measurements <\/td>\n<\/tr>\n
52<\/td>\nFigure B.4 \u2013 Laboratory B results \u2013 LED measurements
Table B.2 \u2013 PDL measurements from Laboratory B <\/td>\n<\/tr>\n
53<\/td>\nFigure B.5 \u2013 Laboratory C results \u2013 Spectral measurements <\/td>\n<\/tr>\n
54<\/td>\nFigure B.6 \u2013 Laboratory C results \u2013 LED measurements
Table B.3 \u2013 PDL measurements from Laboratory C <\/td>\n<\/tr>\n
55<\/td>\nFigure B.7 \u2013 Laboratory D results \u2013 Spectral measurements <\/td>\n<\/tr>\n
56<\/td>\nFigure B.8 \u2013 Laboratory D results \u2013 LED measurements
Table B.4 \u2013 PDL measurements from Laboratory D <\/td>\n<\/tr>\n
57<\/td>\nFigure B.9 \u2013 Laboratory E results \u2013 Spectral measurements <\/td>\n<\/tr>\n
58<\/td>\nFigure B.10 \u2013 Laboratory E results \u2013 LED measurements
Table B.5 \u2013 PDL measurements from Laboratory E <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

Fibre optic interconnecting devices and passive components – Report of round robin test results on SC plug style fixed attenuators<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
BSI<\/b><\/a><\/td>\n2010<\/td>\n60<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":247503,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[649,2641],"product_tag":[],"class_list":{"0":"post-247499","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-33-180-10","7":"product_cat-bsi","9":"first","10":"instock","11":"sold-individually","12":"shipping-taxable","13":"purchasable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/247499","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/247503"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=247499"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=247499"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=247499"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}