{"id":272506,"date":"2024-10-19T18:16:55","date_gmt":"2024-10-19T18:16:55","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-en-11171999\/"},"modified":"2024-10-25T14:36:47","modified_gmt":"2024-10-25T14:36:47","slug":"bs-en-11171999","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-en-11171999\/","title":{"rendered":"BS EN 1117:1999"},"content":{"rendered":"
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
1<\/td>\n | BRITISH STANDARD <\/td>\n<\/tr>\n | ||||||
2<\/td>\n | National foreword <\/td>\n<\/tr>\n | ||||||
5<\/td>\n | Introduction 1 Scope 1.1 This European Standard applies to series\ufffdproduced liquid\ufffdcooled refrigerant condensers which … 1.2 This standard deals with the following types of series\ufffdproduced liquid refrigerant condensers: 2 Normative references 3 Definitions 3.1 liquid-cooled refrigerant condenser 3.2 shell and tube type 3.3 co-axial type 3.4 plate type <\/td>\n<\/tr>\n | ||||||
6<\/td>\n | 3.5 Working fluids 3.6 Capacity 3.7 condensing pressure 3.8 Temperature <\/td>\n<\/tr>\n | ||||||
7<\/td>\n | 3.9 Liquid pressure 3.10 Temperature difference 3.11 high glide 3.12 fouling resistance 3.13 oil content <\/td>\n<\/tr>\n | ||||||
8<\/td>\n | 4 Symbols 4.1 Letters 4.2 Subscripts 4.3 Superscripts <\/td>\n<\/tr>\n | ||||||
9<\/td>\n | 5 Standard capacity 5.1 Basis for standard capacity data 5.2 Standard capacity conditions Table 1 Standard capacity conditions 6 Manufacturer\u2019s data <\/td>\n<\/tr>\n | ||||||
10<\/td>\n | 7 Measurements 7.1 Uncertainty of measurements 7.2 Measurement criteria <\/td>\n<\/tr>\n | ||||||
11<\/td>\n | 8 Testing methods and equipment 8.1 Testing methods <\/td>\n<\/tr>\n | ||||||
12<\/td>\n | 8.2 Testing equipment <\/td>\n<\/tr>\n | ||||||
13<\/td>\n | 9 Test procedures 9.1 Physical arrangement 9.2 Capacity measurements Table 3 Deviations from standard conditions <\/td>\n<\/tr>\n | ||||||
14<\/td>\n | 10 Capacity calculations 10.1 Primary method 10.2 Confirming method 10.3 Relative deviation 11 Conversion to standard conditions 11.1 Standard capacity <\/td>\n<\/tr>\n | ||||||
15<\/td>\n | 11.2 Liquid side pressure drop 12 Test report <\/td>\n<\/tr>\n | ||||||
16<\/td>\n | Annex B (informative) Oil content measurement procedure <\/td>\n<\/tr>\n | ||||||
17<\/td>\n | Annex C (informative) Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" Heat exchangers. Liquid-cooled refrigerant condensers. Test methods for establishing the performance<\/b><\/p>\n |