{"id":445358,"date":"2024-10-20T08:41:23","date_gmt":"2024-10-20T08:41:23","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-en-60269-62011a12023\/"},"modified":"2024-10-26T16:10:01","modified_gmt":"2024-10-26T16:10:01","slug":"bs-en-60269-62011a12023","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-en-60269-62011a12023\/","title":{"rendered":"BS EN 60269-6:2011+A1:2023"},"content":{"rendered":"
The contents of the corrigendum of November 2021 have been included in this copy.<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
2<\/td>\n | undefined <\/td>\n<\/tr>\n | ||||||
7<\/td>\n | CONTENTS <\/td>\n<\/tr>\n | ||||||
9<\/td>\n | FOREWORD <\/td>\n<\/tr>\n | ||||||
11<\/td>\n | 1 General 1.1 Scope and object 1.2 Normative references <\/td>\n<\/tr>\n | ||||||
12<\/td>\n | 2 Terms and definitions 2.2 General terms <\/td>\n<\/tr>\n | ||||||
14<\/td>\n | 3 Conditions for operation in service 3.4 Voltage 3.4.1 Rated voltage 3.5 Current 3.5.1 Rated Current 3.6 Frequency, power factor and time constant 3.6.1 Frequency 3.6.2 Power factor <\/td>\n<\/tr>\n | ||||||
15<\/td>\n | 3.6.3 Time constant 3.10 Temperature inside an enclosure 4 Classification 5 Characteristics of fuses 5.1 Summary of characteristics 5.1.2 Fuse-links 5.2 Rated voltage 5.5 Rated power dissipation of the fuse-link 5.6 Limits of time-current characteristics 5.6.1 Time-current characteristics, time-current zones <\/td>\n<\/tr>\n | ||||||
16<\/td>\n | 5.6.2 Conventional times and currents 5.6.3 Gates 5.7 Breaking range and breaking capacity 5.7.1 Breaking range and utilization category 5.7.2 Rated breaking capacity 6 Markings 6.2 Markings on fuse-links Tables Table 101 \u2013 Conventional times and currents for “gPV” fuse-links <\/td>\n<\/tr>\n | ||||||
17<\/td>\n | 7 Standard conditions for construction 7.5 Breaking capacity 8 Tests 8.1 General 8.1.4 Arrangement of the fuse and dimensions 8.1.5 Testing of fuse-links Table 102 \u2013 Survey of complete tests on fuse-links and numberof fuse-links to be tested <\/td>\n<\/tr>\n | ||||||
18<\/td>\n | 8.3 Verification of temperature rise limits and power dissipation 8.3.1 Arrangement of the fuse-link 8.3.3 Measurement of power dissipation of the fuse-link Table 103 \u2013 Survey of tests on fuse-links of the smallest rated current of a homogeneous series and number of fuse-links to be tested <\/td>\n<\/tr>\n | ||||||
19<\/td>\n | 8.3.5 Acceptability of test results 8.4 Verification of operation 8.4.1 Arrangement of fuse-link 8.4.3 Test method and acceptability of test results <\/td>\n<\/tr>\n | ||||||
20<\/td>\n | 8.5 Verification of the breaking capacity 8.5.1 Arrangement of the fuse 8.5.5 Test method 8.5.8 Acceptability of test results <\/td>\n<\/tr>\n | ||||||
21<\/td>\n | 8.11 Mechanical and miscellaneous tests Table 104 \u2013 Values for breaking-capacity tests on \u201cgPV\u201d fuse-links <\/td>\n<\/tr>\n | ||||||
22<\/td>\n | Figures Figure 101 \u2013 Current of test cycling <\/td>\n<\/tr>\n | ||||||
23<\/td>\n | Annex AA (normative) Examples of standardized fuse-links for the protection of solar photovoltaic energy systems <\/td>\n<\/tr>\n | ||||||
24<\/td>\n | Figure AA.1 \u2013 Fuse-links with cylindrical contact caps, type A <\/td>\n<\/tr>\n | ||||||
25<\/td>\n | Figure AA.2 \u2013 Fuse-links with cylindrical contact caps type A with striker \u2013 Additional dimensions for sizes 14 \u00d7 51, 20 \u00d7 127 and 22 \u00d7 127 only <\/td>\n<\/tr>\n | ||||||
26<\/td>\n | Figure AA.3 \u2013 Cylindrical fuse-links with blade contacts \u2013 Sizes 61-600 A <\/td>\n<\/tr>\n | ||||||
28<\/td>\n | Figure AA.4 \u2013 Fuse-links with blade contacts, type C, C referring IEC 60269-2 \u201cFuse system A (NH fuse system)\u201d <\/td>\n<\/tr>\n | ||||||
30<\/td>\n | Figure AA.5 \u2013 Long fuse-links with blade contacts, type D (specific for PV application) <\/td>\n<\/tr>\n | ||||||
31<\/td>\n | Figure AA.6 \u2013 Replacement handle for long fuse-links with blade contacts <\/td>\n<\/tr>\n | ||||||
32<\/td>\n | Figure AA.7 \u2013 Fuse-bases for long fuse-links with blade contacts <\/td>\n<\/tr>\n | ||||||
33<\/td>\n | Figure AA.8 \u2013 Fuse-links with bolted blade contacts, type E (specific for PV application) <\/td>\n<\/tr>\n | ||||||
34<\/td>\n | Annex BB (informative) Guidance for the protection of photovoltaic strings and arrays with fuse-links designed for PV applications <\/td>\n<\/tr>\n | ||||||
35<\/td>\n | Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" Low-voltage fuses – Supplementary requirements for fuse-links for the protection of solar photovoltaic energy systems<\/b><\/p>\n |