{"id":445467,"date":"2024-10-20T08:41:57","date_gmt":"2024-10-20T08:41:57","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-en-iso-52016-32023\/"},"modified":"2024-10-26T16:11:14","modified_gmt":"2024-10-26T16:11:14","slug":"bs-en-iso-52016-32023","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-en-iso-52016-32023\/","title":{"rendered":"BS EN ISO 52016-3:2023"},"content":{"rendered":"
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
2<\/td>\n | undefined <\/td>\n<\/tr>\n | ||||||
14<\/td>\n | 4.1 Symbols <\/td>\n<\/tr>\n | ||||||
15<\/td>\n | 4.2 Subscripts <\/td>\n<\/tr>\n | ||||||
17<\/td>\n | 4.3 Abbreviated terms 5.1 Output of the method 5.2 General description of the method <\/td>\n<\/tr>\n | ||||||
19<\/td>\n | 6.1 Output data <\/td>\n<\/tr>\n | ||||||
20<\/td>\n | 6.2 Calculation time intervals 6.3 Input data 6.3.1 General <\/td>\n<\/tr>\n | ||||||
21<\/td>\n | 6.3.2 Input data of a simplified adaptive building envelope element 6.3.3 Input data of a detailed adaptive building envelope element <\/td>\n<\/tr>\n | ||||||
23<\/td>\n | 6.3.4 Control related input data <\/td>\n<\/tr>\n | ||||||
25<\/td>\n | 6.3.5 Climatic input data 6.3.6 Constants and physical data 6.3.7 Input data from Annex A and Annex B 6.4 Properties of the adaptive building envelope element 6.4.1 General <\/td>\n<\/tr>\n | ||||||
26<\/td>\n | 6.4.2 Simplified or detailed adaptive building envelope element <\/td>\n<\/tr>\n | ||||||
27<\/td>\n | 6.4.3 Properties of a simplified adaptive building envelope element <\/td>\n<\/tr>\n | ||||||
34<\/td>\n | 6.4.4 Model and properties of a detailed adaptive building envelope element <\/td>\n<\/tr>\n | ||||||
35<\/td>\n | 6.5 Connection of the model of the adaptive building envelope element to the model of the thermal zone of ISO 52016-1 6.5.1 Simplified adaptive building envelope element 6.5.2 Detailed adaptive building envelope element 6.6 Selection of control type <\/td>\n<\/tr>\n | ||||||
36<\/td>\n | 6.7 Modelling of the control of the environmentally activated adaptive building envelope element <\/td>\n<\/tr>\n | ||||||
37<\/td>\n | 6.8 Modelling of the control scenario for the actively controlled adaptive building envelope element 6.8.1 General 6.8.2 Selection of conditions and events <\/td>\n<\/tr>\n | ||||||
39<\/td>\n | 6.8.3 Selection of sensors 6.8.4 Selection of methods to identify the conditions or events <\/td>\n<\/tr>\n | ||||||
46<\/td>\n | 6.8.5 Basic rules for the reference control scenario <\/td>\n<\/tr>\n | ||||||
48<\/td>\n | 6.8.6 Modelling of the user behaviour <\/td>\n<\/tr>\n | ||||||
49<\/td>\n | 6.8.7 Reference control scenarios <\/td>\n<\/tr>\n | ||||||
52<\/td>\n | 6.9 Hourly calculation procedures 6.10 Post-processing: performance characteristics <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" Energy performance of buildings. Energy needs for heating and cooling, internal temperatures and sensible and latent heat loads – Calculation procedures regarding adaptive building envelope elements<\/b><\/p>\n |