{"id":6476,"date":"2024-10-16T18:32:24","date_gmt":"2024-10-16T18:32:24","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/astm-d6745-2006\/"},"modified":"2024-10-24T10:42:51","modified_gmt":"2024-10-24T10:42:51","slug":"astm-d6745-2006","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/astm\/astm-d6745-2006\/","title":{"rendered":"ASTM-D6745 2006"},"content":{"rendered":"
Scope<\/strong><\/p>\n 1.1 This test method covers the determination of the coefficient of linear thermal expansion (CTE) for carbon anodes and cathodes used in the aluminum industry, in baked form, by use of a vitreous silica dilatometer.<\/p>\n 1.2 The applicable temperature range for this test method for research purposes is ambient to 1000\u00b0C. The recommended maximum use temperature for product evaluation is 500\u00b0C.<\/p>\n 1.3 This test method and procedure is based on Test Method E 228, which is a generic all-encompassing method. Specifics dictated by the nature of electrode carbons and the purposes for which they are used are addressed by this procedure.<\/p>\n 1.4 Electrode carbons in the baked form will only exhibit primarily reversible dimensional changes when heated.<\/p>\n 1.5 The values stated in SI units are to be regarded as standard.<\/p>\n 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.<\/i><\/p>\n Keywords<\/strong><\/p>\n aluminum industry; anode; carbon; cathode; coefficient of thermal expansion (CTE); thermal expansion<\/p>\n ICS Code<\/strong><\/p>\n ICS Number Code 19.060 (Mechanical testing)<\/p>\n DOI:<\/strong> 10.1520\/D6745-06<\/p>\n<\/div>\n D6745-06 Standard Test Method for Linear Thermal Expansion of Electrode Carbons<\/b><\/p>\nPDF Catalog<\/h4>\n
\n
\n PDF Pages<\/th>\n PDF Title<\/th>\n<\/tr>\n \n 1<\/td>\n Scope
Referenced Documents
Terminology
Summary of Test Method
Significance and Use
Apparatus <\/td>\n<\/tr>\n\n 2<\/td>\n Test Specimen
Calibration <\/td>\n<\/tr>\n\n 3<\/td>\n Procedure
Calculation <\/td>\n<\/tr>\n\n 4<\/td>\n Report
Precision and Bias
Keywords
A1. STANDARD REFERENCE
A1.1 <\/td>\n<\/tr>\n\n 5<\/td>\n TABLE A1.1
TABLE A1.2
TABLE A1.3 <\/td>\n<\/tr>\n\n 6<\/td>\n X1. ERRORS IN DILATOMETRY
X1.1
X1.2
X1.3
TABLE A1.4 <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"\n\n
\n Published By<\/td>\n Publication Date<\/td>\n Number of Pages<\/td>\n<\/tr>\n \n ASTM<\/b><\/a><\/td>\n 2006<\/td>\n 6<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":6477,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[2637],"product_tag":[],"class_list":{"0":"post-6476","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-astm","8":"first","9":"instock","10":"sold-individually","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/6476","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/6477"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=6476"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=6476"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=6476"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}