{"id":7998,"date":"2024-10-16T19:21:26","date_gmt":"2024-10-16T19:21:26","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/astm-e363-2009\/"},"modified":"2024-10-24T10:57:21","modified_gmt":"2024-10-24T10:57:21","slug":"astm-e363-2009","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/astm\/astm-e363-2009\/","title":{"rendered":"ASTM-E363 2009"},"content":{"rendered":"<\/p>\n

1.1 These test methods cover the chemical analysis of chromium and ferrochromium having chemical compositions within the following limits:<\/p>\n

1.2 The analytical procedures appear in the following order:<\/p>\n

1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.<\/p>\n

1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of whoever uses this standard to consult and establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific hazard statements are given in Section 6.<\/span><\/span><\/p>\n

10.1 This test method covers the determination of arsenic in chromium and ferrochromium in concentrations from 0.001 % to 0.005 %.<\/p>\n

21.1 This test method covers the determination of lead in chromium and ferrochromium in concentrations from 0.001 % to 0.05 %.<\/p>\n

32.1 This test method covers the determination of chromium in all carbon grades of ferrochromium in concentrations from 50 % to 75 %.<\/p>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
1<\/td>\nScope
Referenced Documents
Terminology
Significance and Use
Apparatus, Reagents, and Photometric Practice <\/td>\n<\/tr>\n
2<\/td>\nHazards
Sampling
Rounding Calculated Values
Interlaboratory Studies
Scope
Summary of Method
Concentration Range
Stability of Color
Interferences
Apparatus
FIG. 1 <\/td>\n<\/tr>\n
3<\/td>\nReagents
Preparation of Calibration Curve
Procedure <\/td>\n<\/tr>\n
4<\/td>\nCalculation
Precision and Bias
Scope
Summary of Test Method
Concentration Range
Stability of Color
Interferences
Apparatus
Reagents
TABLE 1 <\/td>\n<\/tr>\n
5<\/td>\nPreparation of Calibration Curve
Procedure
Calculation
Precision and Bias <\/td>\n<\/tr>\n
6<\/td>\nScope
Summary of Test Method
Interferences
Reagents
TABLE 2 <\/td>\n<\/tr>\n
7<\/td>\nProcedure
Calculation
Precision and Bias
Keywords
TABLE 3 <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

E363-09 Standard Test Methods for Chemical Analysis of Chromium and Ferrochromium<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
ASTM<\/b><\/a><\/td>\n2009<\/td>\n8<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":7999,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[1090,2637],"product_tag":[],"class_list":{"0":"post-7998","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-77-040-30","7":"product_cat-astm","9":"first","10":"instock","11":"sold-individually","12":"shipping-taxable","13":"purchasable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/7998","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/7999"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=7998"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=7998"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=7998"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}